12. FCC Test Report DFS rev 1

FCC ID: TE7T2UNANO

Test Report

Download: PDF
FCCID_4113700

                     FCC Radio Test Report
                          FCC ID: TE7T2UNANO
  This report concerns (check one):      Original Grant    Class I Change    Class II Change


           Project No.        :   1808C130
           Equipment          :   AC600 Nano Wireless USB Adapter
           Test Model         :   Archer T2U Nano
           Series Model       :   N/A
           Applicant          :   TP-Link Technologies Co., Ltd.
           Address            :   Building 24 (floors 1,3,4,5) and 28 (floors1-4)
                                  Central Science and Technology Park, Shennan Rd,
                                  Nanshan, Shenzhen, China



           Date of Receipt    :   Aug. 13, 2018
           Date of Test       :   Aug. 29, 2018 ~ Oct. 22, 2018
           Issued Date        :   Dec. 21, 2018
           Tested by          :   BTL Inc.




           Testing Engineer               :
                                                          (Welly Zhou)


           Technical Manager              :
                                                          (Shawn Xiao)


           Authorized Signatory           :
                                                           (Steven Lu)




                  BTL                            INC.
       No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                          Guangdong, China.
          TEL: +86-769-8318-3000     FAX: +86-769-8319-6000




Report No.: BTL-FCCP-3-1808C130                                                    Page 1 of 26
                                                                                Report Version: R02


  Declaration
  BTL represents to the client that testing is done in accordance with standard procedures as applicable and
  that test instruments used has been calibrated with standards traceable to international standard(s) and/or
  national standard(s).
  BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to
  ensure that additional production units of this model are manufactured with the identical electrical and
  mechanical components. BTL shall have no liability for any declarations, inferences or generalizations
  drawn by the client or others from BTL issued reports.
  The report must not be used by the client to claim product certification, approval, or endorsement by A2LA,
  NIST, or any agency of the U.S. Government.
  This report is the confidential property of the client. As a mutual protection to the clients, the public and
  ourselves, the test report shall not be reproduced, except in full, without our written approval.
  BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements,
  and accredited by the conformity assessment authorities listed in this test report.
  BTL is not responsible for the sampling stage, so the results only apply to the sample as received.
  The information, data and test plan are provided by manufacturer, so it is manufacturer’s responsibility to
  ensure that the apparatus meets the essential requirements in all the possible configurations as
  representative of its intended use.
  Limitation
  For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
  test report is (are) included in the conformity assessment authorities acceptance respective.




Report No.: BTL-FCCP-3-1808C130                                                                    Page 2 of 26
                                                                                                Report Version: R02


                           Table of Contents                      Page


   1 . CERTIFICATION                                                 5
   2 . EUT INFORMATION                                               6
      2.1 EUT SPECIFICATION TABLE                                    6
      2.2 CONDUCTED OUTPUT POWER AND EIRP                            7
      2.3 TRANSMIT POWER CONTROL (TPC)                               8
   3 . U-NII DFS RULE REQUIREMENTS                                   9
      3.1 WORKING MODES AND REQUIRED TEST ITEMS                      9
      3.2 TEST FACILITY                                              9
      3.3 TEST LIMITS AND RADAR SIGNAL PARAMETERS                   10
   4 . TEST INSTRUMENTS                                             13
   5 . EMC EMISSION TEST                                            14
      5.1 DFS MEASUREMENT SYSTEM:                                   14
      5.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL:             17
      5.3 DEVIATION FROM TEST STANDARD                              17
   6 . TEST RESULTS                                                 18
      6.1 SUMMARY OF TEST RESULT                                    18
      6.2 TEST MODE: DEVICE OPERATING IN MASTER MODE.               18
      6.3 DFS DETECTION THRESHOLD                                   19
      6.4 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME WLAN TRAFFIC
                                                                    20
      6.5 NON- OCCUPANCY PERIOD                                     24
   7 . EUT TEST PHOTOS                                              26




Report No.: BTL-FCCP-3-1808C130                                  Page 3 of 26
                                                              Report Version: R02


                                   REPORT ISSUED HISTORY

    Report Version                          Description                        Issued Date
         R00         Original Issue.                                           Nov. 09, 2018
         R01         Updated the output power.                                 Nov. 26, 2018
                     Added the Radar detection data and the measurement data
         R02                                                                   Dec. 21, 2018
                     of 5290 MHz@80 MHz BW.




Report No.: BTL-FCCP-3-1808C130                                                    Page 4 of 26
                                                                                Report Version: R02


 1. CERTIFICATION

     Equipment       : AC600 Nano Wireless USB Adapter
     Brand Name      : tp-link
     Test Model      : Archer T2U Nano
      Series Model     N/A
     Applicant       : TP-Link Technologies Co., Ltd.
     Manufacturer    : TP-Link Technologies Co., Ltd.
     Address         : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and
                       Technology Park, Shennan Rd, Nanshan, Shenzhen, China
     Date of Test    : Aug. 29, 2018 ~ Oct. 22, 2018
     Test Sample     : Engineering Sample No.: D180807269
     Standard(s)     : FCC Part 15, Subpart E (Section 15.407) / FCC 06-96
                       FCC KDB 789033 D02 General U-NII Test Procedures New Rules v02r01
                       FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02
                       FCC KDB 905462 D03 UNII Clients Without Radar Detection New Rules
                       v01r02

  The above equipment has been tested and found compliance with the requirement of the relative
  standards by BTL Inc.
  The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
  BTL-FCCP-3-1808C130) were obtained utilizing the test procedures, test instruments, test sites
  that has been accredited by the Authority of A2LA according to the ISO-17025 quality assessment
  standard and technical standard(s).

  Test results included in this report is only for the DFS part.




Report No.: BTL-FCCP-3-1808C130                                                         Page 5 of 26
                                                                                     Report Version: R02


 2. EUT INFORMATION

  2.1 EUT SPECIFICATION TABLE

                                     Table 1: Specification of EUT

    Equipment                            AC600 Nano Wireless USB Adapter
    Brand Name                           tp-link
    Test Model                           Archer T2U Nano
    Series Model                         N/A
    Model Difference(s)                  N/A
    Software Version                     win xp/7/8/8.1/10 : 07/18/2018,1030.29.1102.2017
    Hardware Version                     1.0
    Operational Mode                     Slave

    Operating Frequency Range            5250MHz~5350MHz&5470MHz~5725MHz

    Modulation                           OFDM

  Note: This device was functioned as a

    Master      Slave Without Radar Detection        slave with rada detection

  Note:
  1. For a more detailed features description, please refer to the manufacturer’s specifications or the
     user's manual.
  2. Table for Filed Antenna:


        Ant.        Brand          Model Name        Antenna Type      Connector       Gain (dBi)

         1                              N/A             Internal          N/A             3.38




Report No.: BTL-FCCP-3-1808C130                                                            Page 6 of 26
                                                                                        Report Version: R02


  2.2 CONDUCTED OUTPUT POWER AND EIRP

                   Table 2: The Conducted Output Power and EIRP List

                               Mode: TX (11 ac 20MHz)
      Frequency      Max Couducted Output      Antenna       Max EIRP   Max EIRP
      Band (MHz)         Power (dBm)             Gain          (dBm)       (mW)

      5250~5350              17.83               3.38          21.21     132.130

      5470~5725              17.95               3.38          21.33     135.831


                               Mode: TX (11ac 40MHz)
      Frequency      Max Couducted Output      Antenna       Max EIRP   Max EIRP
      Band (MHz)         Power (dBm)             Gain          (dBm)       (mW)

      5250~5350              17.73               3.38          21.11     129.122

      5470~5725              17.62               3.38          21.00     125.893


                               Mode: TX (11ac 80MHz)
      Frequency      Max Couducted Output      Antenna       Max EIRP   Max EIRP
      Band (MHz)         Power (dBm)             Gain          (dBm)       (mW)

      5250~5350              16.54               3.38          19.92      98.175

      5470~5725              17.72               3.38          21.10     128.825




Report No.: BTL-FCCP-3-1808C130                                            Page 7 of 26
                                                                        Report Version: R02


  2.3TRANSMIT POWER CONTROL (TPC)
  Transmit power control (TPC). U-NII devices operating in the 5.25-5.35 GHz band and the
  5.47-5.725 GHz band shall employ a TPC mechanism. The U-NII device is required to have the
  capability to operate at least 6 dB below the mean EIRP value of 30 dBm. A TPC mechanism is not
  required for systems with an e.i.r.p. of less than 500 mW.

                                Test Mode: UNII-2A/TX AC20 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
     CH52         5260                  20.99                              14.99
     CH60         5300                  20.97                              14.97
     CH64         5320                  20.92                              14.92

                                Test Mode: UNII-2A/TX AC40 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
     CH54         5270                  21.11                              15.11
     CH62         5310                  18.53                              12.53

                                Test Mode: UNII-2A/TX AC80 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
     CH58         5290                  15.52                               9.52

                                Test Mode: UNII-2C/TX AC20 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
    CH100         5500                  20.67                              14.67
    CH116         5580                  20.79                              14.79
    CH140         5700                  20.73                              14.73

                                Test Mode: UNII-2C/TX AC40 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
    CH102         5510                  20.84                              14.84
    CH110         5550                  20.91                              14.91
    CH134         5670                  21.00                              15.00

                                Test Mode: UNII-2C/TX AC80 Mode
               Frequency       Output Power (TPC High)            Output Power (TPC Low)
   Channel
                 (MHz)                  (dBm)                              (dBm)
    CH106         5530                  17.51                              11.51
    CH122         5610                  21.10                              15.10




Report No.: BTL-FCCP-3-1808C130                                                       Page 8 of 26
                                                                                   Report Version: R02


 3. U-NII DFS RULE REQUIREMENTS

  3.1 WORKING MODES AND REQUIRED TEST ITEMS
  The manufacturer shall state whether the EUT is capable of operating as a Master and/or a Client.
  If the EUT is capable of operating in more than one operating mode then each operating mode
  shall be tested separately. See tables 3 and 4 for the applicability of DFS requirements for each of
  the operational modes.

                   Table 3: Applicability of DFS requirements prior to use a channel


                                                             Operational Mode
              Requirement
                                                               Client without     Client with radar
                                               Master
                                                              radar detection         detection
         Non-Occupancy Period                                   Not required
        DFS Detection Threshold                                 Not required
    Channel Availability Check Time                             Not required         Not required
           Uniform Spreading                                    Not required         Not required
       U-NII Detection Bandwidth                                Not required

                  Table 4: Applicability of DFS requirements during normal operation.


                                                             Operational Mode
              Requirement
                                                               Client without     Client with radar
                                               Master
                                                              radar detection         detection
        DFS Detection Threshold                                 Not required
     Channel Closing Transmission
                   Time
          Channel Move Time
       U-NII Detection Bandwidth                                Not required

  3.2TEST FACILITY
  The test facilities used to collect the test data in this report is at the location of No.3,Jinshagang
  1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China.
  BTL's test firm number for FCC: 854385
  BTL's designation number for FCC: CN5020




Report No.: BTL-FCCP-3-1808C130                                                               Page 9 of 26
                                                                                           Report Version: R02


  3.3 TEST LIMITS AND RADAR SIGNAL PARAMETERS

  DETECTION THRESHOLD VALUES

           Table 5: DFS Detection Thresholds for Master Devices and Client Devices With
                                        Radar Detection.

                                                                         Value
            Maximum Transmit Power
                                                                 (See Notes 1 and 2)
                EIRP≥ 200 milliwatt                                    -64 dBm
              EIRP < 200 milliwatt and
                                                                       -62 dBm
       Power pectral density < 10 dBm/MHz
     EIRP < 200 milliwatt that do not meet the
                                                                       -64 dBm
        power spectral density requirement

  Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.

  Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of
  the test transmission waveforms to account for variations in measurement equipment. This will
  ensure that the test signal is at or above the detection threshold level to trigger a DFS response.

  Note3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication
  662911 D01.




Report No.: BTL-FCCP-3-1808C130                                                          Page 10 of 26
                                                                                       Report Version: R02


                            Table 6: DFS Response Requirement Values


                    Parameter                                          Value

   Non-occupancy period                            Minimum 30 minutes
   Channel Availability Check Time                 60 seconds
   Channel Move Time                               10 seconds See Note 1.
                                                   200 milliseconds + an aggregate of 60
   Channel Closing Transmission Time               milliseconds over remaining 10 second
                                                   period. See Notes 1 and 2.
                                                   Minimum 100% of the UNII
   U-NII Detection Bandwidth                       99% transmission power bandwidth. See
                                                   Note 3.

  Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed
  with Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.

  Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at
  the beginning of the Channel Move Time plus any additional intermittent control signals required
  to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10
  second period. The aggregate duration of control signals will not count quiet periods in between
  transmissions.

  Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For
  each frequency step the minimum percentage of detection is 90 percent. Measurements are
  performed with no data traffic.




Report No.: BTL-FCCP-3-1808C130                                                        Page 11 of 26
                                                                                     Report Version: R02


  PARAMETERS OF DFS TEST SIGNALS

  Step intervals of 0.1 microsecond for Pulse Width, 1 microsecond for PRI, 1 MHz for chirp width
  and 1 for the number of pulses will be utilized for the random determination of specific test
  waveforms.

                           Table 7: Short Pulse Radar Test Waveforms.




  A minimum of 30 unique waveforms are required for each of the Short Pulse Radar Types 2
  through 4. If more than 30 waveforms are used for Short Pulse Radar Types 2 through 4, then
  each additional waveform must also be unique and not repeated from the previous waveforms. If
  more than 30 waveforms are used for Short Pulse Radar Type 1, then each additional waveform
  is generated with Test B and must also be unique and not repeated from the previous waveforms
  in Tests A or B.




Report No.: BTL-FCCP-3-1808C130                                                      Page 12 of 26
                                                                                   Report Version: R02


                              Table 8: Long Pulse Radar Test Waveform

                                                                           Minimum
            Pulse     Chirp                  Number                       Percentage     Minimum
   Radar                           PRI                    Number
            Width     Width                  of Pulses                        of          Number
   Type                           (µsec)                  of Bursts
            (µsec)    (MHz)                  per Burst                    Successful      of Trials
                                                                          Detection
       5      50-100      5-20     1000-2000       1-3         8-20          80%           30
  The parameters for this waveform are randomly chosen(The center frequency for each of the 30
  trials of the Bin 5 radar shall be randomly selected within 80% of the Occupied Bandwidth.) Thirty
  unique waveforms are required for the Long Pulse Radar Type waveforms. If more than 30
  waveforms are used for the Long Pulse Radar Type waveforms, then each additional waveform
  must also be unique and not repeated from the previous waveforms.

                         Table 9: Frequency Hopping Radar Test Waveform

                                                                          Minimum
            Pulse     Chirp                 Number                                       Minimum
   Radar                          PRI                    Number         Percentage of
            Width     Width                of Pulses                                      Number
   Type                          (µsec)                  of Bursts       Successful
            (µsec)    (MHz)                per Burst                                      of Trials
                                                                          Detection
     6         1        333         9        0.333          300              70%             30


 4. TEST INSTRUMENTS

                                   Table 10: Test instruments list.

                                                                                       Calibration
   DESCRIPTION MANUFACTURER                  MODEL NO.                Serial No
                                                                                          Until
   EXA Spectrum
                            Agilent               N9010A           MY50520044         Mar. 11, 2019
      Analyzer
        Signal
                            Agilent               E4438C           MY49071316         Mar. 11, 2019
     Generator
      POWER
                         Mini-Circuits       ZFRSC-123-S+          331000910-1        Mar. 11, 2019
     SPLITTER
      POWER
                         Mini-Circuits       ZN4PD1-63-S+        SF9335D1045-1        Mar. 11, 2019
     SPLITTER
     Attenuator            WOKEN                 6SM3502           VAS1214NL          Feb. 14, 2019
   Master Device         GPON ONU               G-240W-B               N/A                 N/A
  Note:
        (1) Calibration interval of instruments listed above is one year.
        (2) Master device’s FCC ID: 2ADZRG240WB




Report No.: BTL-FCCP-3-1808C130                                                            Page 13 of 26
                                                                                         Report Version: R02


 5. EMC EMISSION TEST

  5.1DFS MEASUREMENT SYSTEM:
  Test Precedure
  1. Master device and client device are set up by conduction method as the following
     configuration.
  2. The client device is connected to notebook and to access a IP address on wireless
     connection with the master device.
  3. Then the master device is connected to another notebook to access a IP address.
  4. Finally, let the two IP addresses run traffic with each other through the Run flow software “Lan
      test” to reach 17% channel loading as below
  Setup




Report No.: BTL-FCCP-3-1808C130                                                          Page 14 of 26
                                                                                       Report Version: R02


  Channel Loading


                                  11ac 80MHz Mode




                                                                 Dutycycle   Limit
   Channel     Marker Delta   Number      On Time   Total Time
                                                                   (%)        (%)
     5530           2.561         7        17.927     101.3       17.70      17.00




Report No.: BTL-FCCP-3-1808C130                                         Page 15 of 26
                                                                      Report Version: R02


  The hopping type 6 pulse parameters are fixed while the hopping sequence is based on the
  August 2005 NTIA Hopping Frequency List. The initial starting point randomized at run-time and
  each subsequent starting point is incremented by 475. Each frequency in the 100-length segment
  is compared to the boundaries of the EUT Detection Bandwidth and the software creates a
  hopping burst pattern in accordance with Section 7.4.1.3 Method #2 Simulated Freqeuncy
  Hopping Radar Waveform Generating Subsystem of FCC 06-96. The frequency of the signal
  generator is incremented in 1 MHz steps from FL to FH for each successive trial. This incremental
  sequence is repeated as required to generate a minimum of 30 total trials and to maintain a
  uniform frequency distribution over the entire Detection Bandwidth.

  The signal monitoring equipment consists of a spectrum analyzer set to display 8001 bins on the
  horizontal axis. The time-domain resolution is 2 msec / bin with a 16 second sweep time, meeting
  the 10 second short pulse reporting criteria. The aggregate ON time is calculated by multiplying
  the number of bins above a threshold during a particular observation period by the dwell time per
  bin, with the analyzer set to peak detection and max hold.

  Should multiple RF ports be utilized for the Master and/or Slave devices (for example, for diversity
  or MIMO implementations), additional combiner/dividers are inserted between the Master
  Combiner/Divider and the pad connected to the Master Device (and/or between the Slave
  Combiner/Divider and the pad connected to the Slave Device). Additional pads are utilized such
  that there is one pad at each RF port on each EUT.




Report No.: BTL-FCCP-3-1808C130                                                          Page 16 of 26
                                                                                       Report Version: R02


  5.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL:
  A 50 ohm load is connected in place of the spectrum analyzer, and the spectrum analyzer is
  connected in place of the master device and the signal generator is set to CW mode. The
  amplitude of the signal generator is adjusted to yield a level of –62 dBm as measured on the
  spectrum analyzer.

  Without changing any of the instrument settings, the spectrum analyer is reconnected to the
  Common port of the Spectrum Analyzer Combiner/Divider. Measure the amplitude and calculate
  the difference from –62 dBm. Adjust the Reference Level Offset of the spectrum analyzer to this
  difference.
  The spectrum analyzer displays the level of the signal generator as received at the antenna ports
  of the Master Device. The interference detection threshold may be varied from the calibrated
  value of –62 dBm and the spectrum analyzer will still indicate the level as received by the Master
  Device.
  Set the signal generator to produce a radar waveform, trigger a burst manually and measure the
  level on the spectrum analyzer. Readjust the amplitude of the signal generator as required so that
  the peak level of the waveform is at a displayed level equal to the required or desired interference
  detection threshold. Separate signal generator amplitude settings are determined as required for
  each radar type.




  5.3 DEVIATION FROM TEST STANDARD
  No deviation.




Report No.: BTL-FCCP-3-1808C130                                                          Page 17 of 26
                                                                                       Report Version: R02


 6. TEST RESULTS

  6.1 SUMMARY OF TEST RESULT


                                               Test Mode and
   Clause          Test Parameter                                       Remarks          Pass/Fail
                                                  Channel

    15.407    DFS Detection Threshold                 -               No Applicable          N/A

              Channel Availability Check
    15.407                                            -               Not Applicable         N/A
                         Time
                                           11ac 80MHz 5290 MHz
    15.407       Channel Move Time                                      Applicable           Pass
                                           11ac 80MHz 5530 MHz

                   Channel Closing         11ac 80MHz 5290 MHz
    15.407                                                              Applicable           Pass
                  Transmission Time        11ac 80MHz 5530 MHz
                                           11ac 80MHz 5290 MHz
    15.407     Non- Occupancy Period                                    Applicable           Pass
                                           11ac 80MHz 5530 MHz
    15.407        Uniform Spreading                   -               Not Applicable         N/A

    15.407    U-NII Detection Bandwidth               -               Not Applicable         N/A


  6.2 TEST MODE: DEVICE OPERATING IN MASTER MODE.
  The EUT is slave equipment, it need a master device when testing.
  Master with injection at the Master. (Radar Test Waveforms are injected into the Master)




Report No.: BTL-FCCP-3-1808C130                                                          Page 18 of 26
                                                                                       Report Version: R02


  6.3 DFS DETECTION THRESHOLD

  Calibration:

  The EUT is slave equipment and it with a max gain is 3.38 dBi.
  For a detection threshold level of -62dBm and the master antenna gain is 2.90 dBi, required
  detection threshold is -58.62 dBm (= -62+2.90).

  Note: Maximum Transmit Power is less than 200 milliwatt in this report, so detection threshold
  level is -62dBm.




                                         Radar Signal 0




Report No.: BTL-FCCP-3-1808C130                                                         Page 19 of 26
                                                                                      Report Version: R02


  6.4 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME WLAN TRAFFIC

  TX (11ac 80MHz Mode)

  Radar signal 0




  Note:   T0 denotes the start of Channel Move Time upon the end of the last Radar burst.
          T1 denotes the data transmission time of 200ms from T1.
          T2 denotes the end of Channel Move Time.
          T3 denotes the 10 second from T0 to observe the aggregate duration of transmissions.




  Note: An expanded plot for the device vacates the channel in the required 500ms


Report No.: BTL-FCCP-3-1808C130                                                       Page 20 of 26
                                                                                    Report Version: R02


                                  11ac 80MHz Mode
               Item           Measured Value(s)                 Limit(s)
        Channel Move Time         0.2344941                        10
                                                  200 milliseconds + an aggregate of
        Channel Close Time           0.0            60 milliseconds over remaining 10
                                                             second period




Report No.: BTL-FCCP-3-1808C130                                                Page 21 of 26
                                                                             Report Version: R02


  TX (11ac 80MHz Mode)

  Radar signal 0




  Note:   T0 denotes the start of Channel Move Time upon the end of the last Radar burst.
          T1 denotes the data transmission time of 200ms from T1.
          T2 denotes the end of Channel Move Time.
          T3 denotes the 10 second from T0 to observe the aggregate duration of transmissions.




  Note: An expanded plot for the device vacates the channel in the required 500ms



Report No.: BTL-FCCP-3-1808C130                                                       Page 22 of 26
                                                                                    Report Version: R02


                                  11ac 80MHz Mode
               Item           Measured Value(s)                 Limit(s)
        Channel Move Time         0.2754931                        10
                                                  200 milliseconds + an aggregate of
        Channel Close Time           0.0            60 milliseconds over remaining 10
                                                             second period




Report No.: BTL-FCCP-3-1808C130                                                Page 23 of 26
                                                                             Report Version: R02


  6.5 NON- OCCUPANCY PERIOD


  During the 30 minutes observation time, UUT did not make any transmissions on a channel after a
  radar signal was detected on that channel by either the Channel Availability Check or the
  In-Service Monitoring.

                                       TX (11ac 80MHz Mode)
                                   5290 Non-Occupancy perrod




Report No.: BTL-FCCP-3-1808C130                                                         Page 24 of 26
                                                                                      Report Version: R02


                                  TX (11ac 80MHz Mode)
                            5530 Non-Occupancy perrod




Report No.: BTL-FCCP-3-1808C130                            Page 25 of 26
                                                         Report Version: R02


 7. EUT TEST PHOTOS

                              DFS Measurement Photos




                                    End of Test Report

Report No.: BTL-FCCP-3-1808C130                            Page 26 of 26