3UL                                                             Report No.: BTL—FCCP—2—1908C101




           FCC RF EXPOSURE REPORT

                        FCC ID: TEZKP4O0O0V2
 Project No.           19080101
 Equipment             Smart Outdoor Plug
 Brand Name            top—link
 Test Model            KP400
 Series Model          N/A
 Applicant             TP—Link Technologies Co., Ltd.
 Address               Building 24(floors1,3,4,5) and 28(floors1—4) Central Science and
                       Technology Park, Shennan Rd, Nanshan, Shenzhen, China
 Manufacturer          TP—Link Technologies Co., Ltd.
 Address               Building 24(floors1,3,4,5) and 28(floors1—4) Central Science and
                       Technology Park, Shennan Rd, Nanshan, Shenzhen, China
 Date of Receipt       Aug. 16, 2019
 Date of Test          Aug. 19, 2019 ~ Sep. 03, 2019
 Issued Date           Sep. 16, 2019
 Report Version        ROO
 Test Sample           Engineering Sample No.:
 Standard(s)           FCC Guidelines for Human Exposure IEEE C95.1 & FCC Part
                       2.1091
                       FCC Title 47 Part 2.1091, OET Bulletin 65 Supplement C


  The above equipment has been tested and found compliance with the requirement of
  the relative standards by BTL Inc.




   Rose. . W
    Prepared by : Rose Liu                     6 \:::, /..

       W                                      1Bz—MlMH
      j                                        "4@~\::
                                                 ho  x
                                                       [ACCREDITED)
   Approved by : Ethan Ma                            wdavhs*

                                                       Certificate #5123.02


 Add: No.3, Jinshagang 1st Road, Shixia, Dalang Town,Dongguan, Guangdong, China.
 Tel: +86—769—8318—3000
 Web: www.newbtl.com




                                       Page 1 of 3


                                             Report No.: BTL-FCCP-2-1908C101



                 REPORT ISSUED HISTORY

Report Version                Description                   Issued Date
     R00                    Original Issue                 Sep. 16, 2019




                      Page 2 of 3


3UL                                                                           Report No.: BTL—FCCP—2—1908C101



 1. MPE CALCULATION METHOD

            Calculation Method of RF Safety Distance:

            $   . o_m
                  in    4P

          where:
           S = power density
           P = power input to the antenna
           G = power gain of the antenna in the direction of interest relative to an isotropic radiator
           R = distance to the center of radiation of the antenna

Table for Filed Antenna


   Ant.                Brand          Model Name       Antenna Type         Connector          Gain (dBi)
    1           TP—LINK:                 N/A                PCB                   N/A             1.87


 2. TEST RESULTS

     Antenna              Antenna      Max. Peak     Max. Peak        Power         Limit of Power         Test
       Gain                 Gain      Output Power| Output Power|   Density (S)       Density (S)         Result
          (dBi)          (numeric)       (dBm)           (mW)         (mW/icm?)         (mW/cm?)
          1.87               1.5382      26.78         476.4310         0.14586            1             Complies

Note: The calculated distance is 20 cm.