13. MPE

FCC ID: TE7KP400

RF Exposure Info

Download: PDF
FCCID_4064199

               FCC RF EXPOSURE REPORT
                            FCC ID: TE7KP400

      Project No.   : 1807C080
      Equipment     : Smart Outdoor Plug
      Model         : KP400
      Applicant     : TP-Link Technologies Co., Ltd.
      Address       : Building 24(floors1,3,4,5) and 28(floors1-4)
                      Central Science and Technology Park,
                      Shennan Rd, Nanshan, Shenzhen, China

      According: : FCC Guidelines for Human Exposure IEEE
                   C95.1 & FCC Part 2.1091




                    BTL                  INC.
         No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                            Guangdong, China.
            TEL: +86-769-8318-3000     FAX: +86-769-8319-6000




Report No.: BTL-FCCP-2-1807C080                                      Page 1 of 3


  1. CERTIFICATION

      Equipment     :   Smart Outdoor Plug
      Brand Name :      tp-link
      Test Model :      KP400
      Series Model :    N/A
      Applicant    :    TP-Link Technologies Co., Ltd.
      Manufacturer :    TP-Link Technologies Co., Ltd.
      Address      :    Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and Technology
                        Park, Shennan Rd, Nanshan, Shenzhen, China
      Factory       :   TP-Link Technologies Co., Ltd.
      Address       :   Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and Technology
                        Park, Shennan Rd, Nanshan, Shenzhen, China
      Date of Test :    Jul. 17, 2018~Jul. 30, 2018
      Test Sample :     Engineering Sample No.: D180705809

   The above equipment has been tested and found compliance with the requirement of the relative
   standards by BTL Inc.
   The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
   BTL-FCCP-2-1807C080) were obtained utilizing the test procedures, test instruments, test sites
   that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment
   standard and technical standard(s).




Report No.: BTL-FCCP-2-1807C080                                                          Page 2 of 3


  2. MPE CALCULATION METHOD

            Calculation Method of RF Safety Distance:




         where:
         S = power density
         P = power input to the antenna
         G = power gain of the antenna in the direction of interest relative to an isotropic radiator
         R = distance to the center of radiation of the antenna


 Table for Filed Antenna

         Ant.            Brand             Model Name       Antenna Type     Connector Gain(dBi)

            1               N/A               N/A               PIFA             N/A         2.5



  3. TEST RESULTS

    Antenna                Average      Average      Power     Limit of Power
            Antenna Gain                                                                        Test
     Gain                Output Power Output Power Density (S)   Density (S)
             (numeric)                                      2                                  Result
     (dBi)                  (dBm)        (mW)      (mW/cm )      (mW/cm2)
      2.5          1.7783          22.91         195.4339        0.06918            1         Complies


 Note: the calculated distance is 20 cm.




Report No.: BTL-FCCP-2-1807C080                                                              Page 3 of 3



Document Created: 2019-05-04 02:42:06
Document Modified: 2019-05-04 02:42:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC