13. FCC MPE

FCC ID: TE7KP200

RF Exposure Info

Download: PDF
FCCID_4070632

               FCC RF EXPOSURE REPORT
                             FCC ID: TE7KP200


      Project No.     :   1808C015
      Equipment       :   Smart Wi-Fi Power Outlet
      Test Model      :   KP200
      Series Model    :   N/A
      Applicant       :   TP-Link Technologies Co., Ltd.
      Address         :   Building 24(floors1,3,4,5) and 28(floors1-4)
                          Central Science and Technology Park, Shennan
                          Rd, Nanshan, Shenzhen, China

      According:      : FCC Guidelines for Human Exposure IEEE C95.1
                        & FCC Part 2.1091




                   BTL                   INC.
         No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                            Guangdong, China.
            TEL: +86-769-8318-3000     FAX: +86-769-8319-6000



Report No.: BTL-FCCP-2-1808C015                                   Page 1 of 3
                                                              Report Version: R01


  1. CERTIFICATION

      Equipment :      Smart Wi-Fi Power Outlet
      Brand Name :     tp-link
      Test Model :     KP200
      Series Model :   N/A
      Applicant    :   TP-Link Technologies Co., Ltd.
      Manufacturer :   TP-Link Technologies Co., Ltd.
      Address      :   Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and Technology
                       Park, Shennan Rd, Nanshan, Shenzhen, China
      Factory      :   TP-Link Technologies Co., Ltd.
      Address      :   Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and Technology
                       Park, Shennan Rd, Nanshan, Shenzhen, China
      Date of Test :   Aug. 03, 2018 ~ Aug. 24, 2018
      Test Sample :    Engineering Sample No.: D180806505

   The above equipment has been tested and found compliance with the requirement of the relative
   standards by BTL Inc.
   The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
   BTL-FCCP-2-1808C015) were obtained utilizing the test procedures, test instruments, test sites
   that has been accredited by the Authority of A2LA according to the ISO-17025 quality assessment
   standard and technical standard(s).




Report No.: BTL-FCCP-2-1808C015                                                        Page 2 of 3
                                                                                   Report Version: R01


  2. MPE CALCULATION METHOD

            Calculation Method of RF Safety Distance:




           where:
           S = power density
           P = power input to the antenna
           G = power gain of the antenna in the direction of interest relative to an isotropic radiator
           R = distance to the center of radiation of the antenna


 Table for Filed Antenna:

    Ant.          Brand            Model Name           Antenna Type          Connector       Gain (dBi)
     1                                  N/A                   PCB               I-PEX            2.71



  3. TEST RESULTS

    Antenna                                                        Power     Limit of Power
            Antenna Gain         AVG Output AVG Output                                            Test
     Gain                                                        Density (S)   Density (S)
             (numeric)           Power (dBm) Power (mW)                                          Result
     (dBi)                                                       (mW/cm2)      (mW/cm2)
      2.71          1.8664           20.87         122.1800      0.04538897           1         Complies

   Note: the calculated distance is 20 cm.




                                              End of Test Report

Report No.: BTL-FCCP-2-1808C015                                                               Page 3 of 3
                                                                                          Report Version: R01



Document Created: 2019-04-06 11:11:49
Document Modified: 2019-04-06 11:11:49

© 2024 FCC.report