1612066R-FCC-RF Exposure-Wi-Fi Smart Light Switch-HS200-V1.1 20160425

FCC ID: TE7HS200

RF Exposure Info

Download: PDF
FCCID_2971531

          RF Exposure Evaluation Declaration


                      Product Name : Smart Wi-Fi Light Switch
                      Model No.              : HS200
                      FCC ID                 : TE7HS200




       Applicant : TP-LINK TECHNOLOGIES CO., LTD.
       Address         : Building 24(floors1,3,4,5) and 28(floors1-4) Central
                           Science and Technology Park, Shennan Rd,
                           Nanshan, Shenzhen, China




                    Date of Receipt : Jan. 30, 2016
                    Issued Date              : Apr. 22, 2016
                    Report No.               : 1612066R-RF-US-P20V01
                    Report Version : V1.1




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.


                                                         Report No: 1612066R-RF-US-P20V01



               Tes t R e p o r t C e r t i f i c a t i o n
                                                    Issued Date : Apr. 22, 2016
                                                    Report No. : 1612066R-RF-US-P20V01




Product Name          :       Smart Wi-Fi Light Switch
Applicant             :       TP-LINK TECHNOLOGIES CO., LTD.
Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                              Science and Technology Park, Shennan Rd, Nanshan,
                              Shenzhen, China
Manufacturer          :       TP-LINK TECHNOLOGIES CO., LTD.
Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                              Science and Technology Park, Shennan Rd, Nanshan,
                              Shenzhen, China
Model No.             :       HS200
FCC ID                :       TE7HS200
EUT Voltage           :       AC 100-240V, 50/60Hz
Brand Name            :       TP-LINK
Applicable Standard   :       KDB 447498D01V06
                              FCC Part1.1310(b)
                              FCC Part2 (Section 2.1091)
                              KDB 447498 D03
                              IEEE C95.1
Test Result           :       Complied
Performed Location    :       Quietek Corporation - Suzhou EMC Laboratory
                              No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                              215006, Jiangsu, China
                              TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                              FCC Registration Number: 800392


Documented By             :

                                      (Senior Adm. Specialist: Alice Ni )

Reviewed By               :

                                       (Senior Engineer: Jack Zhang )

Approved By               :

                                    (Engineering Manager : Harry Zhao )


                                     Page: 2 of 7


                                                                  Report No: 1612066R-RF-US-P20V01



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 USA                    :   FCC
 Japan                  :   VCCI
 China                  :   CNAS


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site : http://www.quietek.com/english/about/certificates.aspx?bval=5
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/index_en.aspx
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 7


                                                   Report No: 1612066R-RF-US-P20V01


History of This Test Report
      REPORT NO.         VERSION               DESCRIPTION           ISSUED DATE


 1612066R-RF-US-P20V01   V1.0        Initial Issued Report           Mar. 09, 2016


 1612066R-RF-US-P20V01   V1.1        Modified the EIRP to            Apr. 22, 2016


                                     conducted power.




                                Page: 4 of 7


                                                             Report No: 1612066R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
         Frequency            Field              Field
                                                                   Density           Time
         Range (MHz)          Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
         (A) Limits for Occupational/ Control Exposures
         300-1500             --                 --                F/300             6
         1500-100,000         --                 --                5                 6
         (B) Limits for General Population/ Uncontrolled Exposures
         300-1500             --                 --                F/1500            6
         1500-100,000         --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 5 of 7


                                                                Report No: 1612066R-RF-US-P20V01


1.2. Test Procedure

    Software provided by client enabled the EUT to transmit and receive data at lowest, middle
    and highest channel individually.
    The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

    Product            :   Smart Wi-Fi Light Switch
    Test Item          :   RF Exposure Evaluation
    Test Site          :   AC-6


    z   Antenna information:
    Model No.              N/A
    Antenna                TP-LINK
    manufacturer
    Antenna Delivery              1*TX+1*RX                  2*TX+2*RX           3*TX+3*RX
    Antenna technology            SISO
                                                    Basic
                                  MIMO              CDD
                                                    Beam-forming
    Antenna Type                  External          Dipole
                                                    PIFA
                                                    PCB
                                  Internal
                                                    Ceramic Chip Antenna
                                                    Metal plate type F antenna
    Antenna Gain           3.28dBi




                                             Page: 6 of 7


                                                                       Report No: 1612066R-RF-US-P20V01


     z    Output Power into Antenna & RF Exposure Evaluation Distance:


2.4GHz:
                                             Maximum Output                              Power Density at
                   Frequency Band                                      Antenna Gain
   Test Mode                                     Power to                                   R = 20 cm
                         (MHz)                                             (dBi)
                                              Antenna (dBm)                                 (mW/cm2)
    802.11b            2412 - 2462                16.52                    3.28             0.018999
    802.11g            2412 - 2462                20.85                    3.28             0.051491
802.11n(20MHz)         2412 - 2462                21.22                    3.28             0.056070
802.11n(40MHz)       2422 - 2452             16.35                3.28            0.018270
                                                           2
So according to transmission formula: Pd = (Pout*G)/(4*pi*r ) and the power density limit
according to KDB 447498D01V06 and FCC Part1.1310(b), the limit is 1mW/cm2
     Safety Distance Calculation Formula:
     The power flux:
                          P*G (θ ,φ )
                    S=
                          4*π *r 2
     So safety distance as following:
                            P *G
                    r=
                           4*π *S
     P = input power of the antenna
     G = antenna gain relative to an isotropic antenna
     θ, Ф = elevation and azimuth angles.
     r = distance from the antenna to the point of investigation


                                                            Maximum
                                                        Output Power Limit of Power
                                  Frequency Range                                           Safety Distance
          Test Mode                                             to             Density
                                          (MHz)                                                  r(cm)
                                                              Antenna        S(mW/cm2)
                                                               (dBm)
      802.11n(20MHz)                    2412 - 2462            21.22               1             3.25
     Note: The safety distance is 3.25cm for the router without any other radio equipment.