FCC MPE Report_Rev 1

FCC ID: TE7HS107

RF Exposure Info

Download: PDF
FCCID_3745794

                       Test Report No.: FS180105N021


                                    RF EXPOSURE REPORT
   Applicant                        TP—Link Technologies Co., Ltd.

   Address                          Building 24(floors1,3,4,5) and 28(floors1—4) Central Science and Technology Park,
                                    Shennan Rd, Nanshan, Shenzhen, China


   Manufacturer or                  TP—Link Technologies Co., Ltd.
   Supplier

   Address                          Building 24(floors1,3,4,5) and 28(f|oor§1 —4) Central Science and Technology Park,
                                    Shennan Rd, Nanshan, Shenzhen, China

   Product                          Smart Wi—Fi Plug, 2—Outlet

   Brand Name                       to—link

   Model                            HS107

   Additional Model &               N/A
   Model Difference

   Date of tests                    Jan. 05, 2018 ~ Jan. 11, 2018

   [<] FCC Part 2 (Section 2.1091)
   [X 447498 D01 General RF Exposure Guidance v06
   [X IEEE C95.1


   CONCLUSION: The submitted sample was found to COMPLY with the test requirement


                           Tested by Harry Li                                                                Approved by Glyn He
                  Project Engineer/ EMC Department                                                       Supervisor / EMC Department




                                                                                                                Date: Jan. 29, 2018
   This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
   only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
   report are not indicative or representative of the quality or characteristics of the lot ffom which a test sample was taken or any similar or identical product
   unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
   provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
   however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
   mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non—compliance to the specification



                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                     Email: customerservice.dg@cn.bureauveritas.com

                                                                           Page 1 of 6                                                               Report Version 1


                  Test Report No.: FS180105N021

                                    TABLE OF CONTENTS
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION.............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 2 of 6                                                    Report Version 1


        Test Report No.: FS180105N021


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FS180105N021             Original release                                                         Jan. 29, 2018




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


        Test Report No.: FS180105N021


   1. CERTIFICATION


                        FCC ID:     TE7HS107

                   PRODUCT:         Smart Wi-Fi Plug, 2-Outlet

              BRAND NAME:           tp-link

                 MODEL NO.:         HS107

         ADDITIONAL NO.:            N/A

             TEST SAMPLE:           Engineering Sample

                 APPLICANT:         TP-Link Technologies Co., Ltd.

               STANDARDS:           FCC Part 2 (Section 2.1091)

                                    KDB 447498 D01

                                    IEEE C95.1




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 4 of 6                                                    Report Version 1


        Test Report No.: FS180105N021


   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
                                                                          2
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm )                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


B U R E A U
               Test Report No.: FS180105N021


        5. ANTENNA GAIN

               The antennas provided to the EUT, please refer to the following table:
                    Transmitter                                                      Antenna
                                              Peak         Gai   Bi
                        Circuit                 eak Gain (dBi)                         Type
                        Chain 0                        3                            PCB antenna




        6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

          FREQUENCY          may powrr           ANTENNA                PIiSIANCE           POWER                    Eimt
            BAND                (mw)               GAIN                    (cm)             DENSITY                (mW/cm?)
               (MHz)                                 (dBi)                                  (mW/cm*)
              2412—2462           172.187              3                       20             0.0683                    1.0




          ——— END ———




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
    Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                            Fax: +86 769 8593 1080
    Dongguan Branch
                                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                                 Page 6 of 6                                                Report Version 1



Document Created: 2018-02-07 09:17:33
Document Modified: 2018-02-07 09:17:33

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC