1712082R-FCC-RF Exposure-Smart Open-Closed Sensor-CS100-V2.0

FCC ID: TE7CS100

RF Exposure Info

Download: PDF
FCCID_3450329

          RF Exposure Evaluation Declaration


        Product Name : Smart Open-Closed Sensor
        Model No.               : CS100
        FCC ID                  : TE7CS100




       Applicant : TP-Link Technologies Co., Ltd.
       Address         : Building 24(floors1,3,4,5) and 28(floors1-4) Central
                           Science and Technology Park, Shennan Rd,
                           Nanshan, Shenzhen, China




               Date of Receipt : Jan. 17, 2017
               Test Date                   Jan. 17, 2017~ Feb. 20, 2017
               Issued Date             : Mar. 09, 2017
               Report No.              : 1712082R-RF-US-P20V01
               Report Version : V2.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF, CNAS or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing and Certification
(Suzhou) Co., Ltd. Corporation.


Report No: 1712082R-RF-US-P20V01



                    Tes t R e p o r t C e r t i f i c a t i o n
                                                          Issued Date : Mar. 09, 2017
                                                          Report No. : 1712082R-RF-US-P20V01



     Product Name          :       Smart Open-Closed Sensor
     Applicant             :       TP-Link Technologies Co., Ltd.
     Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                                   Science and Technology Park, Shennan Rd, Nanshan,
                                   Shenzhen, China
     Manufacturer          :       TP-Link Technologies Co., Ltd.
     Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                                   Science and Technology Park, Shennan Rd, Nanshan,
                                   Shenzhen, China
     Model No.             :       CS100
     FCC ID                :       TE7CS100
     EUT Voltage           :       DC 1.5V
     Applicable Standard   :       KDB 447498D01V06
                                   FCC Part1.1310
     Test Result           :       Complied
     Performed Location    :       DEKRA Testing and Certification (Suzhou) Co., Ltd.
                                   Corporation - Suzhou EMC Laboratory
                                   No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                                   215006, Jiangsu, China
                                   TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                                   FCC Registration Number: 800392


      Documented By            :

                                               (Adm. Specialist: Kitty Li )

      Reviewed By              :

                                              (Senior Engineer: Frank He )

      Approved By              :

                                          (Engineering Manager : Harry Zhao )



                                           Page: 2 of 5


Report No: 1712082R-RF-US-P20V01



 History of This Test Report

        REPORT NO.             VERSION              DESCRIPTION   ISSUED DATE


 1712082R-RF-US-P20V01        V1.0        Initial Issued Report   Mar. 02, 2017


 1712082R-RF-US-P06V01        V2.0        Modified Product Name   Mar. 09, 2017




                                     Page: 3 of 5


Report No: 1712082R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
          Frequency           Field              Field
                                                                   Density           Time
          Range (MHz)         Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
          (A) Limits for Occupational/ Control Exposures
          300-1500            --                 --                F/300             6
          1500-100,000        --                 --                5                 6
          (B) Limits for General Population/ Uncontrolled Exposures
          300-1500            --                 --                F/1500            6
          1500-100,000        --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd is the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 4 of 5


Report No: 1712082R-RF-US-P20V01


1.2. Test Procedure
     Software provided by client enabled the EUT to transmit and receive data at lowest, middle
     and highest channel individually.
     The temperature and related humidity: 18℃and 78% RH.
1.3. Test Result of RF Exposure Evaluation

Product                 :   Smart Open-Closed Sensor
Test Item               :   RF Exposure Evaluation
Test Site               :   AC-6


           Antenna Information
  Model No.                 CS100
  Antenna manufacturer      TP-LINK
  Antenna Delivery                 1*TX+1*RX                  2*TX+2*RX            3*TX+3*RX
  Antenna technology               SISO
                                                     Basic
                                   MIMO              CDD
                                                     Beam-forming
  Antenna Type                     External          Dipole
                                                     PIFA
                                                     PCB
                                   Internal
                                                     Ceramic Chip Antenna
                                                     Metal plate type F antenna
  Antenna Gain              1.84dBi


           Output Power into Antenna & RF Exposure Evaluation Distance:
     Standlone modes
                                              Maximum                         Power         Power
                                                              Directional
                       Frequency Band Output Power                          Density at R Density Limit
      Test Mode                                                  Gain
                           (MHz)           to                                 = 20 cm    at R = 20 cm
                                                                 (dBi)
                                          Antenna (dBm)                     (mW/cm2)      (mW/cm2)
   Zigbee             2405 ~ 2480 MHz           5.53             1.84         0.0011          1.0


Note: The simultaneous transmission power density is 0.0011mW/cm2 for without Smart
Open-Closed Sensor any other radio equipment.