13. MPE Rev2

FCC ID: TE7CPE605

RF Exposure Info

Download: PDF
FCCID_4326588

                 FCC RF EXPOSURE REPORT

                                  FCC ID: TE7CPE605


       Project No.      : 1812C197
       Equipment        : 5GHz 150Mbps 23dBi Outdoor CPE
       Model            : CPE605
       Applicant        : TP-Link Technologies Co., Ltd.
       Address          : Building 24 (floors 1,3,4,5) and 28 (floors1-4),
                          Central Science and Technology Park, Nanshan
                          Shenzhen, 518057 China

       According        : FCC Guidelines for Human Exposure IEEE
                          C95.1 & FCC Part 2.1091




                     BTL                     INC.
          No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                             Guangdong, China.
             TEL: +86-769-8318-3000     FAX: +86-769-8319-6000




Report No.: BTL-FCCP-2-1812C197                                            Page 1 of 4
                                                                    Report Version: R01


   1. GENERAL SUMMARY

       Equipment     :   5GHz 150Mbps 23dBi Outdoor CPE
       Brand Name :      tp-link
       Test Model :      CPE605
       Series Model :    N/A
       Applicant    :    TP-Link Technologies Co., Ltd.
       Manufacturer :    TP-Link Technologies Co., Ltd.
       Address      :    Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology
                         Park, Nanshan Shenzhen, 518057 China
       Factory       :   TP-Link Technologies Co., Ltd.
       Address       :   Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology
                         Park, Nanshan Shenzhen, 518057 China
       Date of Test :    Dec. 27, 2018 ~ Mar. 09, 2019
       Test Sample :     Engineering Sample No.: D181110844
       Standards    :    FCC Title 47 Part 2.1091, OET Bulletin 65 Supplement C

    The above equipment has been tested and found compliance with the requirement of the relative
    standards by BTL Inc.
    The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
    BTL-FCCP-2-1812C197) were obtained utilizing the test procedures, test instruments, test sites
    that has been accredited by the Authority of A2LA according to the ISO/IEC 17025 quality
    assessment standard and technical standard(s).




Report No.: BTL-FCCP-2-1812C197                                                              Page 2 of 4
                                                                                      Report Version: R01


3UL                                                                                                    py

   2. MPE CALCULATION METHOD

             Calculation Method of RF Safety Distance:

             ,. 16_IBP
             " in 4n
            where:
            S = power density
            P = power input to the antenna
            G = power gain of the antenna in the direction of interest relative to an isotropic radiator
            R = distance to the center of radiation of the antenna

    Antenna Specification:

     Ant.           Brand            Mode!l Name      Antenna Type       Connector       Gain (dBi)

       1                                  N/A               PCB             N/A            18.32
    Note:
    The antenna were fixed point to point,so the power and PSD limit not need to be reduced.




Report No.: BTL—FCCP—2—18120C197                                                                   Page 3 of 4
                                                                                          Report Version: RO1


   3. TEST RESULTS

    For 5GHz UNII-1:
      Antenna     Antenna      Max. Output     Max. Output     Power     Limit of Power
                                                                                            Test
        Gain        Gain         Power           Power       Density (S)   Density (S)
                                                                                           Result
        (dBi)    (numeric)       (dBm)           (mW)        (mW/cm2)      (mW/cm2)
        18.32       67.9204       12.86          19.3197         0.26119       1          Complies


    For 5GHz UNII-3:
      Antenna     Antenna      Max. Output     Max. Output     Power     Limit of Power
                                                                                            Test
        Gain        Gain         Power           Power       Density (S)   Density (S)
                                                                                           Result
        (dBi)    (numeric)       (dBm)           (mW)        (mW/cm2)      (mW/cm2)
        18.32       67.9204       17.39          54.8277         0.74123       1          Complies

  Note: The calculated distance is 20 cm.




                                            End of Test Report

Report No.: BTL-FCCP-2-1812C197                                                           Page 4 of 4
                                                                                   Report Version: R01



Document Created: 2019-07-01 15:43:49
Document Modified: 2019-07-01 15:43:49

© 2024 FCC.report