16A2003R-FCC-RF Exposure-CPE210-2.4GHz 300Mbps 9dBi Outdoor CPE-V1.0

FCC ID: TE7CPE210V2

RF Exposure Info

Download: PDF
FCCID_3212156

          RF Exposure Evaluation Declaration


           Product Name :             2.4GHz 300Mbps 9dBi Outdoor CPE
           Model No.             :    CPE210
           FCC ID                :    TE7CPE210V2




      Applicant : TP-Link Technologies Co.,Ltd.
      Address         : Building 24(floors1,3,4,5) and 28(floors1-4) Central
                          Science and Technology Park, Shennan Rd, Nanshan,
                          Shenzhen, China



                 Date of Receipt : Oct. 09, 2016
                 Test Date               : Oct. 09, 2016~ Oct. 31, 2016
                 Issued Date             : Nov. 04, 2016
                 Report No.              : 16A2003R-RF- US-P20V01
                 Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF, CNAS or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.


                                                         Report No: 16A2003R-RF-US-P20V01



               Tes t R e p o r t C e r t i f i c a t i o n
                                                    Issued Date : Nov. 04, 2016
                                                    Report No. : 16A2003R-RF-US-P20V01




Product Name          :       2.4GHz 300Mbps 9dBi Outdoor CPE
Applicant             :       TP-Link Technologies Co.,Ltd.
Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                              Science and Technology Park, Shennan Rd, Nanshan,
                              Shenzhen, China
Manufacturer          :       TP-Link Technologies Co.,Ltd.
Address               :       Building 24(floors1,3,4,5) and 28(floors1-4) Central
                              Science and Technology Park, Shennan Rd, Nanshan,
                              Shenzhen, China
Model No.             :       CPE210
FCC ID                :       TE7CPE210V2
EUT Voltage           :       POE(24V)
Applicable Standard   :       KDB 447498D01V06
                              FCC Part1.1310(b)
Test Result           :       Complied
Performed Location    :       Quietek Corporation - Suzhou EMC Laboratory
                              No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                              215006, Jiangsu, China
                              TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                              FCC Registration Number: 800392



Documented By             :

                                         (Adm. Specialist: Kathy Feng )

Reviewed By               :

                                         (Senior Engineer: Frank He )

Approved By               :

                                    (Engineering Manager: Harry Zhao )




                                     Page: 2 of 7


                                                                  Report No: 16A2003R-RF-US-P20V01



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 USA                    :   FCC
 Japan                  :   VCCI
 China                  :   CNAS


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site : http://www.quietek.com/english/about/certificates.aspx?bval=5
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/index_en.aspx
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 7


                                                   Report No: 16A2003R-RF-US-P20V01


History of This Test Report
      REPORT NO.         VERSION               DESCRIPTION           ISSUED DATE


 16A2003R-RF-US-P20V01   V1.0        Initial Issued Report           Nov. 04, 2016




                                Page: 4 of 7


                                                             Report No: 16A2003R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
         Frequency            Field              Field
                                                                   Density           Time
         Range (MHz)          Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
         (A) Limits for Occupational/ Control Exposures
         300-1500             --                 --                F/300             6
         1500-100,000         --                 --                5                 6
         (B) Limits for General Population/ Uncontrolled Exposures
         300-1500             --                 --                F/1500            6
         1500-100,000         --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 5 of 7


                                                                  Report No: 16A2003R-RF-US-P20V01


1.2. Test Procedure

     Software provided by client enabled the EUT to transmit and receive data at lowest, middle
     and highest channel individually.
     The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

     Product           :   2.4GHz 300Mbps 9dBi Outdoor CPE
     Test Item         :   RF Exposure Evaluation
     Test Site         :   AC-6


        Antenna Gain:
Antenna manufacturer       TP-Link
Antenna Delivery                  1*TX+1*RX                  2*TX+2*RX           3*TX+3*RX
Antenna technology                SISO
                                                    Basic
                                                    Sectorized antenna systems
                                                    Cross-polarized antennas
                                  MIMO              Unequal antenna gains, with equal transmit powers
                                                    Spatial Multiplexing
                                                    CDD
                                                    Beam-forming
Antenna Type                      External          Dipole
                                                    PIFA
                                                    PCB
                                  Internal          Ceramic Chip Antenna
                                                    Metal plate type F antenna
                                                    Cross-polarize Antenna
Antenna Gain #0            9dBi
Antenna Gain #1            9dBi
                                                             Directional Gain
   Antenna Technology                                             (dBi)
                                             For Power                           For PSD
   Cross-polarize
                                                9                                    9
   Antenna


                                             Page: 6 of 7


                                                             Report No: 16A2003R-RF-US-P20V01


        Output Power into Antenna & RF Exposure Evaluation Distance:


                                       Maximum                           Power
                                                        Directional                    Limit of Power
                       Frequency      Output Power                    Density at R =
    Test Mode                                              Gain                           Density
                      Band (MHz)           to                            22 cm
                                                           (dBi)                        S(mW/cm2)
                                     Antenna (dBm)                     (mW/cm2)
802.11b/g/n(20MHz)    2412 ~ 2462         28.81             9             0.993             1.0
802.11n(40MHz)        2422 ~ 2422         24.65             9             0.381             1.0


Note: The power density is 0.993mW/cm2 for 2.4GHz 300Mbps 9dBi Outdoor CPE without any
other radio equipment. And the safety distance is 22cm without any other radio equipment.



                                            The End