Test report

FCC ID: TBQT12-LR2W

Test Report

Download: PDF
FCCID_3933570

                         Shenzhen ZhongjianNanfang Testing Co., Ltd.
                                                                                        Report No:CCISE180512301

         1      Cover Page

                              FCC REPORT
    Applicant:                          PORTMAN ELECTRONICS (DONGGUAN) CO., LTD.
                                        NO#10, Luyi 2 Road, Keyuancheng, Tangxia Town,
    Address of Applicant:               DONGGUAN CITY, GUANGDONG PROVINCE CHINA
                                        523718
    Equipment Under Test (EUT)

     Product Name:                      CAR ALARM

     Model No.:                         18TWLOR, 18TWPRLOR

    FCC ID:                             TBQT12-LR2W

    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.247

    Date of sample receipt:             31 May., 2018

    Date of Test:                       31 May., to 15 Jun., 2018

    Date of report issued:              15 Jun., 2018

    Test Result:                        PASS *

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




Bruce Zhang
   Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                Report No: CCISE180512301

2      Version

      Version No.                        Date                                   Description
            00                     15 Jun., 2018                                  Original




    Tested by:                                                          Date:          15 Jun., 2018

                                        Test Engineer


    Reviewed by:                                                        Date:          15 Jun., 2018

                                      Project Engineer




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                         Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 2 of 40


                                                                                                                       Report No: CCISE180512301

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND MODE ............................................................................................................................ 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS ANDMEASUREMENT DATA ................................................................................................. 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED OUTPUT POWER .............................................................................................................................. 9
    6.3     OCCUPY BANDWIDTH .......................................................................................................................................... 10
    6.4     POWER SPECTRAL DENSITY ............................................................................................................................... 12
    6.5     BAND EDGE ......................................................................................................................................................... 14
       6.5.1 Conducted Emission Method...................................................................................................................... 14
       6.5.2 Radiated Emission Method ......................................................................................................................... 16
    6.6     SPURIOUS EMISSION ........................................................................................................................................... 22
       6.6.1 Conducted Emission Method...................................................................................................................... 22
       6.6.2 Radiated Emission Method ......................................................................................................................... 24
7       TEST SETUP PHOTO ........................................................................................................................................ 29
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 30




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                                                        Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                               Page 3 of 40


                                                                                   Report No: CCISE180512301

 4      Test Summary
                      Test Item                                Section in CFR 47                  Result
                Antenna requirement                             15.203/15.247 (c)                  Pass
        AC Power Line Conducted Emission                                15.207                      N/A
          Conducted Peak Output Power                              15.247 (b)(3)                   Pass
              6dB Emission Bandwidth                               15.247 (a)(2)                   Pass
               Power Spectral Density                               15.247 (e)                     Pass
                      Band Edge                                     15.247(d)                      Pass
                 Spurious Emission                                15.205/15.209                    Pass
   Pass: The EUT complies with the essential requirements in the standard.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                            Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                 Page 4 of 40


                                                                           Report No: CCISE180512301

5      General Information
5.1 Client Information
     Applicant:                   PORTMAN ELECTRONICS (DONGGUAN) CO., LTD.
     Address:                     NO#10, Luyi 2 Road, Keyuancheng, Tangxia Town, DONGGUAN CITY,
                                  GUANGDONG PROVINCE CHINA 523718
     Manufacturer/ Factory:       PORTMAN ELECTRONICS (DONGGUAN) CO., LTD.
     Address:                     NO#10, Luyi 2 Road, Keyuancheng, Tangxia Town, DONGGUAN CITY,
                                  GUANGDONG PROVINCE CHINA 523718

5.2 General Description of E.U.T.
      Product Name:               CAR ALARM
      Model No.:                  18TWLOR, 18TWPRLOR
      Operation Frequency:        916.3 MHz
      Channel numbers:            1
      Modulation technology:      Lora
      Antenna Type:               Helix Antenna
      Antenna gain:               -1.25dBi
      Power supply:               DC 3V(CR2450 Battery)
      Remark:                     Item No.: 18TWLOR, 18TWPRLOR were identical inside, the electrical circuit
                                  design, layout, components used and internal wiring, with only difference
                                  being model name and for different areas.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 5 of 40


                                                                           Report No: CCISE180512301

5.3 Test environment and mode
 Operating Environment:
    Temperature:                     24.0 C
    Humidity:                        54 % RH
    Atmospheric Pressure:            1010 mbar
 Test mode:
    Operation mode                   Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m(below 1GHz)/1.5m(above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
        N/A

5.5 Measurement Uncertainty
                    Parameters                                          Expanded Uncertainty
         Radiated Emission (9kHz ~ 30MHz)                                  ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                 ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                   ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                  ±2.88 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 6 of 40


                                                                                 Report No: CCISE180512301

5.8 Test Instruments list
Radiated Emission:
                                                                              Inventory      Cal. Date      Cal. Due date
Item    Test Equipment          Manufacturer               Model No.
                                                                                 No.        (mm-dd-yy)      (mm-dd-yy)
 1          3m SAC                 SAEMC                9(L)*6(W)* 6(H)      CCIS0001       08-23-2014      08-22-2020
 2     BiConiLog Antenna      SCHWARZBECK                 VULB9163           CCIS0005       02-25-2018      02-24-2019
 3       Horn Antenna         SCHWARZBECK                BBHA9120D           CCIS0006       02-25-2018      02-24-2019
         Pre-amplifier
 4                                   HP                     8447D            CCIS0003       02-25-2018      02-24-2019
        (10kHz-1.3GHz)
         Pre-amplifier      Compliance Direction
 5                                                        PAP-1G18           CCIS0011       02-25-2018      02-24-2019
        (1GHz-18GHz)            Systems Inc.
         Pre-amplifier                                   AFS33-18002
 6                            Rohde & Schwarz                                 GTS218        02-25-2018      02-24-2019
          (18-26GHz)                                     650-30-8P-44
 7       Horn Antenna         ETS-LINDGREN                   3160             GTS217        02-25-2018      02-24-2019
       Spectrum analyzer
 8                            Rohde & Schwarz               FSP30            CCIS0023       02-25-2018      02-24-2019
           9k-30GHz
 9     EMI Test Receiver      Rohde & Schwarz               ESRP7            CCIS0167       02-25-2018      02-24-2019
10       Loop antenna        Laplace instrument             RF300            EMC0701        02-25-2018      02-24-2019
11     EMI Test Software           AUDIX                      E3                N/A            N/A              N/A


Conducted Emission:
                                                                                              Cal.Date      Cal.Due date
Item    Test Equipment          Manufacturer              Model No.         Inventory No.
                                                                                            (mm-dd-yy)      (mm-dd-yy)
 1      Shielding Room      ZhongShuo Electron     11.0(L)x4.0(W)x3.0(H)     CCIS0061       07-22-2017      07-21-2020
 2     EMI Test Receiver     Rohde & Schwarz               ESCI              CCIS0002       02-25-2018      02-24-2019
 3           LISN                 CHASE                  MN2050D             CCIS0074       02-25-2018      02-24-2019
 4           LISN            Rohde & Schwarz              ESH3-Z5           8438621/010     02-25-2018      02-24-2019
 5       Coaxial Cable              CCIS                    N/A              CCIS0086       02-25-2018      02-24-2019
 6     EMI Test Software          AUDIX                    E3                    N/A            N/A             N/A
 7      Power Sensor              D.A.R.E               RPR3006W           17I00015SNO27    11-10-2017      11-09- 2018
 8       Power Sensor             D.A.R.E               RPR3006W           17I00015SNO28    11-10-2017      11-09- 2018




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                               Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                    Page 7 of 40


                                                                           Report No: CCISE180512301

6      Test results andMeasurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part15 C Section 15.203 /247(c)
      15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
       E.U.T Antenna:
       The antenna is an coil antenna which cannot replace by end-user, the best case gain of the antenna is -
       1.25 dBi.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 8 of 40


                                                                             Report No: CCISE180512301

6.2 Conducted Output Power
        Test Requirement:               FCC Part15 C Section 15.247 (b)(3)
        Test Method:                    ANSI C63.10:2013 and KDB 558074(latest version)
        Limit:                          30dBm
        Test setup:




        Test procedure:                 1.  Use a fast power sensor suitable for 2,4 GHz and capable of 1 MS/s.
                                        2.  Connect the power sensor to the transmit port, sample the transmit
                                            signal and store the raw data, every channel 25 bursts. Use these
                                            stored samples in all following steps.
                                        3. Find the start and stop times of each burst in the stored
                                            measurement samples.
                                        4. Between the start and stop times of each individual burst calculate
                                            the RMS power over the burst. Save these Pburst values, as well as
                                            the start and stop times for each burst.
                                        5. The highest of all Pburst values (value "A" in dBm) will be used for
                                            maximum e.i.r.p. calculations.
                                        Add the (stated) antenna assembly gain "G" in dBi of the individual
                                              antenna. The RF Output Power (P) shall be calculated using the
                                              formula below: P = A + G
        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed


Measurement Data:
                                 Maximum Conducted Output Power
     Test Frequency                                                          Limit(dBm)                Result
                                                 (dBm)
        916.3 MHz                                 17.53                         30.00                  Pass




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                        Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 9 of 40


                                                                               Report No: CCISE180512301

6.3 Occupy Bandwidth
        Test Requirement:               FCC Part15 C Section 15.247 (a)(2)
        Test Method:                    ANSI C63.10:2013 and KDB 558074(latest version)
        Limit:                          >500kHz
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Measurement Data:

                                     6dB Emission Bandwidth
        Test Frequency                                                     Limit(kHz)                 Result
                                                (MHz)
          916.3 MHz                             0.764                        >500                     Pass

                                      99% Occupy Bandwidth
        Test Frequency                                                     Limit(kHz)                 Result
                                               (MHz)
          916.3 MHz                             0.796                         N/A                         N/A




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                             Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                 Page 10 of 40


CCIS                                                                                  Report No: CCISE180512301

Test plot as follows:

                                                                        oersa i (ri o
                                                                                    is as
                         ree 26.5 den        care                          761.000000000 kuz
                                                                        markadi omm




                         Center #16.3 nne                                          span 2 nuz




                    Date: 7.JUN.2018    17:42:34




                                                                        marker i (rid
                                                                                     17.a0 aan
                         ree 26.5 den        care                            #16.056000000 imz
                                                                        Gewree[ cosscobes
                                                                                    s| is
                                                                               eeso00bee
                                                                                   rel >
                                                                               ses000he0




                         Center #16.3 nne                                          span 2 nuz




                    Date: 7.JUN.2018    17:44:09




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                      Project No.:CCISE1805123
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 11 of 40


                                                                           Report No: CCISE180512301

6.4 Power Spectral Density
        Test Requirement:               FCC Part15 C Section 15.247 (e)
        Test Method:                    ANSI C63.10:2013 and KDB 558074(latest version)
        Limit:                          8dBm
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Measurement Data:

         Test Frequency                Power Spectral Density (dBm)        Limit(dBm)                Result

           916.3 MHz                                -55.96                    8.00                   Pass




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                      Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 12 of 40


CCIS                                                                                    Report No: CCISE180512301

Test plots as follow:

                    @                                        «hew 2 kie    marker i iri a
                                                             «vaw 10 kiz             —ss.96 can
                         ree 26.5 den        «ats   2o ae     sur 225 ne      #16.332000000 mmz




                         Center #16—3 nne               200 kn=,                     span 2 nuz




                    Date: 7.JUN.2018    17:36:15




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                       Project No.:CCISE1805123
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 13 of 40


                                                                              Report No: CCISE180512301

6.5 Band Edge
6.5.1 Conducted Emission Method
        Test Requirement:               FCC Part15 C Section 15.247 (d)
        Test Method:                    ANSI C63.10:2013 and KDB 558074(latest version)
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the
                                        spreadspectrum intentional radiator is operating, the radio frequency
                                        power that is produced by the intentional radiator shall be at least 20 dB
                                        below that in the 100 kHz bandwidth within the band that contains the
                                        highest level of the desired power, based on either an RF conducted or a
                                        radiated measurement.
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                          Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 14 of 40


CCIS                                                                                        Report No: CCISE180512301

Test plots as follow:

                    @                                           «haw 100 knz   marker 2 (ri o
                                                                «vaw 200 kn              —i2.10 can
                         ree 26.5 den        «ats   2o ae        sur s me         e28.060000000 imz
                                                                               marke][1 im




                         ere
                         cenver sre.2 nu—                   < miey                      span «o nuz




                    Date: 7.JUN.2018    17:46:36




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                           Project No.:CCISE1805123
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 15 of 40


                                                                                Report No: CCISE180512301

6.5.2     Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209 and 15.205
      Test Method:                     ANSI C63.10: 2013 and KDB 558074(latest version)
      Test Frequency Range:            960MHz to 1.240GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                     Frequency             Detector        RBW        VBW           Remark
                                        960MHz-1GHz           Quasi-peak      120kHz     300kHz Quasi-peak Value
                                                                 Peak          1MHz       3MHz         Peak Value
                                            Above 1GHz
                                                                 RMS           1MHz       3MHz       Average Value
      Limit:                                      Frequency              Limit (dBuV/m @3m)             Remark
                                                960MHz-1GHz                      54.00             Quasi-peak Value
                                                                                 54.00              Average Value
                                                 Above 1GHz
                                                                                 74.00                Peak Value
      Test Procedure:                  1.    The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the groundat a 3 meter chamber.The table
                                             was rotated 360 degrees todetermine the position of the highest
                                             radiation.
                                       2.    The EUT was set 3 meters away from the interference-receiving
                                             antenna, whichwas mounted on the top of a variable-height antenna
                                             tower.
                                       3.    The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make the
                                             measurement.
                                       4.    For each suspected emission, the EUT was arranged to its worst case
                                             and thenthe antenna was tuned to heights from 1 meter to 4 meters and
                                             the rotatablewas turned from 0 degrees to 360 degrees to find the
                                             maximum reading.
                                       5.    The test-receiver system was set to Peak Detect Function and
                                             SpecifiedBandwidth with Maximum Hold Mode.
                                       6.    If the emission level of the EUT in peak mode was 10dB lower than the
                                             limitspecified, then testing could be stopped and the peak values of the
                                             EUT wouldbe reported. Otherwise the emissions that did not have 10dB
                                             margin would bere-tested one by one using peak, quasi-peak or
                                             average method as specified andthen reported in a data sheet.
      Test setup:                      Below 1GHz




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                            Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                 Page 16 of 40


                                                                          Report No: CCISE180512301

                                       Above 1GHz




      Test Instruments:                Refer to section 5.8 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Passed




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                   Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                       Page 17 of 40


                                                                        Report No: CCISE180512301



Below 1GHz
Horizontal:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 18 of 40


                                                                        Report No: CCISE180512301



Test channel: Lowest
Vertical:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 19 of 40


                                                                        Report No: CCISE180512301



Above 1GHz
Horizontal:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 20 of 40


                                                                        Report No: CCISE180512301



Test channel: Highest
Vertical:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 21 of 40


                                                                              Report No: CCISE180512301

6.6     Spurious Emission
6.6.1     Conducted Emission Method
        Test Requirement:               FCC Part15 C Section 15.247 (d)
        Test Method:                    ANSI C63.10:2013 and KDB 558074(latest version)
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the
                                        spreadspectrum intentional radiator is operating, the radio frequency
                                        power that is produced by the intentional radiator shall be at least 20 dB
                                        below that in the 100 kHz bandwidth within the band that contains the
                                        highest level of the desired power, based on either an RF conducted or a
                                        radiated measurement.
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                          Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 22 of 40


CCIS                                                                                         Report No: CCISE180512301

Test plot as follows:

                    @                                            «maw 100 knz   mavker i) (ri o
                                                                 «vam 200 kn               ~40.30 dam
                         ree 26.5 den        «ats   2o ae         sur ie             s.818800000. onz




                          —
                         seare 20 mz                        e07 muz,                     stop 10 on—




                    Date: 7.JUN.2018    17:50:35


                                                       30MHz~10GHz




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                             Project No.:CCISE1805123
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 23 of 40


                                                                                  Report No: CCISE180512301

 6.6.2 Radiated Emission Method
        Test Requirement:               FCC Part15 C Section 15.209 and 15.205
        Test Method:                    ANSI C63.10:2013
        Test Frequency Range:           9KHz to 25GHz
        Test site:                      Measurement Distance: 3m
        Receiver setup:                    Frequency          Detector        RBW        VBW           Remark
                                          30MHz-1GHz         Quasi-peak      120KHz     300KHz     Quasi-peak Value
                                                               Peak           1MHz       3MHz        Peak Value
                                             Above 1GHz
                                                               RMS            1MHz       3MHz       Average Value
        Limit:                            Frequency                       Limit (dBuV/m @3m)      Remark
                                          30MHz-88MHz                     40.0                    Quasi-peak Value
                                          88MHz-216MHz                    43.5                    Quasi-peak Value
                                          216MHz-960MHz                   46.0                    Quasi-peak Value
                                          960MHz-1GHz                     54.0                    Quasi-peak Value
                                                                          54.0                    Average Value
                                          Above 1GHz
                                                                          74.0                    Peak Value
        Test Procedure:                 1.     The EUT was placed on the top of a rotating table 0.8m(below
                                               1GHz)/1.5m(above 1GHz) above the groundat a 3 meter
                                               chamber.The table was rotated 360 degrees todetermine the
                                               position of the highest radiation.
                                        2.     The EUT was set 3 meters away from the interference-receiving
                                               antenna, whichwas mounted on the top of a variable-height antenna
                                               tower.
                                        3.     The antenna height is varied from one meter to four meters above
                                               the ground to determine the maximum value of the field strength.
                                               Both horizontal and vertical polarizations of the antenna are set to
                                               make the measurement.
                                        4.     For each suspected emission, the EUT was arranged to its worst
                                               case and thenthe antenna was tuned to heights from 1 meter to 4
                                               meters and the rotatablewas turned from 0 degrees to 360 degrees
                                               to find the maximum reading.
                                        5.     The test-receiver system was set to Peak Detect Function and
                                               SpecifiedBandwidth with Maximum Hold Mode.
                                        6.     If the emission level of the EUT in peak mode was 10dB lower than
                                               the limitspecified, then testing could be stopped and the peak values
                                               of the EUT wouldbe reported. Otherwise the emissions that did not
                                               have 10dB margin would bere-tested one by one using peak, quasi-
                                               peak or average method as specified andthen reported in a data
                                               sheet.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                              Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                  Page 24 of 40


                                                                           Report No: CCISE180512301

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                           found the Y-axis is the worst case.
                                        2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                           in this report.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                      Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                           Page 25 of 40


                                                                        Report No: CCISE180512301


Below 1GHz
Horizontal:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 26 of 40


                                                                        Report No: CCISE180512301


Vertical:




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                     Page 27 of 40


                                                                                    Report No: CCISE180512301

Above 1GHz
                                                           Peak value
                                                   Aux
                 Read      Antenna     Cable     Factor(d      Preamp       Level                    Over
 Frequency                                                                            Limit Line
                 Level      Factor     Loss         B)          Factor     (dBuV/                    Limit      Polarization
   (MHz)                                                                              (dBuV/m)
                (dBuV)      (dB/m)      (dB)                     (dB)        m)                      (dB)

  1832.60       45.93       26.07       4.17        2.42        41.31      37.28        74.00       -36.72        Vertical
  2748.90       46.24       28.12       5.08        2.88        41.72      40.60        74.00       -33.40        Vertical
  3665.20       46.55       29.38       5.96        2.97        41.63      43.23        74.00       -30.77        Vertical
  4581.50       46.51       31.23       6.87        3.57        42.12      46.06        74.00       -27.94        Vertical
  5497.80       45.64       32.31       7.13        3.92        41.86      47.14        74.00       -26.86        Vertical
  1832.60       47.14       26.07       4.17        2.42        41.31      38.49        74.00       -35.51      Horizontal
  2748.90       45.98       28.12       5.08        2.88        41.72      40.34        74.00       -33.66      Horizontal
  3665.20       46.13       29.38       5.96        2.97        41.63      42.81        74.00       -31.19      Horizontal
  4581.50       46.92       31.23       6.87        3.57        42.12      46.47        74.00       -27.53      Horizontal
  5497.80       45.90       32.31       7.13        3.92        41.86      47.40        74.00       -26.60      Horizontal
                                                       Average value
                                                   Aux
                 Read      Antenna     Cable     Factor(d      Preamp       Level                    Over
 Frequency                                                                            Limit Line
                 Level      Factor     Loss         B)          Factor     (dBuV/                    Limit      Polarization
   (MHz)                                                                              (dBuV/m)
                (dBuV)      (dB/m)      (dB)                     (dB)        m)                      (dB)

  1832.60       36.23       26.07       4.17        2.42        41.31      27.64        54.00       -26.36        Vertical
  2748.90       37.45       28.12       5.08        2.88        41.72      31.79        54.00       -22.21        Vertical
  3665.20       37.89       29.38       5.96        2.97        41.63      34.62        54.00       -19.38        Vertical
  4581.50       37.78       31.23       6.87        3.57        42.12      37.37        54.00       -16.63        Vertical
  5497.80       36.26       32.31       7.13        3.92        41.86      37.77        54.00       -16.23        Vertical
  1832.60       37.86       26.07       4.17        2.42        41.31      29.31        54.00       -24.69      Horizontal
  2748.90       36.24       28.12       5.08        2.88        41.72      30.58        54.00       -23.42      Horizontal
  3665.20       36.95       29.38       5.96        2.97        41.63      33.68        54.00       -20.32      Horizontal
  4581.50       37.54       31.23       6.87        3.57        42.12      37.13        54.00       -16.87      Horizontal
  5497.80       36.57       32.31       7.13        3.92        41.86      38.08        54.00       -15.92      Horizontal

Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                 Project No.:CCISE1805123
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 28 of 40



Document Created: 2018-07-12 14:30:11
Document Modified: 2018-07-12 14:30:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC