Cal cert Mixer FS-Z90

FCC ID: TA8AKRD901059-1

Test Report

Download: PDF
FCCID_4075233

                                            Farran Technology Ltd.,
                                            Unit 1 Airport East Technology Park,
                                            Farmers Cross, Co. Cork,
                                            Ireland.

                                Certificate of Calibration
                         Certificate No : FCC 10312

Model#: FS-Z90              S/N: 757569/011         Cal Freq: 60-90GHz
Calibration Date : 23-08-2018
As Shipped Condition : On completion of testing, measurement points within
                         specification
Comments: Unit calibrated to spec, results on file.
Measurement Uncertainty: +/-1.5dB
Customer : RISE Research Institute of Sweden AB
            Brinellgatan 4
            504 62 Boras
            Schweden

Location of Calibration: Farran Technology


Certified By:   Michael Crowley       Date 23/08/2018



 Signature


This calibration certificate documents, that the named item is tested and measured
against defined specifications.
Measurement results are located usually in the corresponding interval with a
probability of approx 95% (coverage factor k=2).
Calibration is performed with test equipment and standards directly or indirectly
traceable by means of approved calibration techniques to the PTB/DKD or other
national / international standards, which realize the physical units of measurement
according to the International System of Units (SI).
Principals and methods of calibration correspond and are conformant with EN
ISO/IEC 17025 and ANSI/NCSL Z540-1-1994. The applied quality system is certified
to EN ISO 9001.
This calibration certificate may not be reproduced other than in full. Calibration
certificates without signatures are not valid.
The user is obliged to have the object recalibrated at appropriate intervals.




                              Page 1 of 3                      FTL FORM/189/A


Calibration Procedure No: STP 27
Calibration Equipment used:
Description:        Model No:      S/N:         Certificate No.   Cal Due
Agilent Spectrum    8563E          3846A09627   1-9030600322-14   July 2019
Analyzer
Agilent Power       E4418A         GB38273183   1-9030600322-4    July 2019
Meter
Agilent Power       8481A          3318A94748   1-9030600322-25   July 2019
Sensor
Agilent Power       V8486A         MY44420202   1-9306855147-1    Nov 2019
Sensor
Agilent Power       W8486A         3318A00477   1-9306855147-2    Nov 2019
Sensor
Agilent             E8247B         MY43320714   1-9030600322-24   July 2019
Synthesized
Generator
Agilent             83712B         US37100716   1-9030600322-10   July 2019
Synthesized
Generator




                            Page 2 of 3                   FTL FORM/189/A


Conversion Loss Data for Harmonic Mixer FS-Z90 (60 ..
                      90 GHz)
                      (Order No. 8800000960/53JW/L6)
                                     Revision 1.30




Ser. No.                                             757569/011


Conversion loss data valid for following operating conditions:

IF                                           741,4 MHz (valid for 404,4 MHz and 729,9 MHz too)
Order of
Harmonic                                                       6
                                                        10.12 to
LO frequency range                                    15.12GHz
                                                      +15.5dBm
LO level                                                nominal
Bias                                                       0 mA


                     Conversion Loss /                             Conversion Loss /
Frequency / GHz             dB               Frequency / GHz              dB
     60.00                -23.35                  75.31                 -28.55
     60.61                -22.46                  75.92                 -28.91
     61.22                -22.12                  76.53                 -29.07
     61.84                -22.37                  77.14                 -29.43
     62.45                -22.55                  77.76                 -30.37
     63.06                -22.60                  78.37                 -31.81
     63.67                -23.08                  78.98                 -33.06
     64.29                -24.05                  79.59                 -34.16
     64.90                -25.32                  80.20                 -34.92
     65.51                -25.92                  80.82                 -36.62
     66.12                -26.22                  81.43                 -36.34
     66.74                -27.74                  82.04                 -35.60
     67.35                -27.70                  82.65                 -35.13
     67.96                -26.20                  83.27                 -35.00
     68.57                -25.67                  83.88                 -34.92
     69.18                -25.23                  84.49                 -35.30
     69.80                -24.52                  85.10                 -34.89
     70.41                -24.49                  85.71                 -34.16
     71.02                -24.90                  86.33                 -33.66
     71.63                -25.41                  86.94                 -33.45
     72.25                -26.09                  87.55                 -32.75
     72.86                -26.47                  88.16                 -32.20
     73.47                -27.26                  88.78                 -31.49
     74.08                -27.90                  89.39                 -30.73
     74.69                -28.66                  90.00                 -30.24




                                   Page 3 of 3                            FTL FORM/189/A



Document Created: 2018-08-23 10:58:08
Document Modified: 2018-08-23 10:58:08