Test report WCDMA+GSM

FCC ID: TA8AKRC161636

Test Report

Download: PDF
FCCID_3614969

REPORT
issued by an Accredited Testing Laboratory

Contact person RISE                            Date                     Reference                                      Page

Tomas Lennhager                                 2017-10-23              7P06127-WG                                     1 (27)              Testing
Electronics
+46 10 516 54 09
tomas.lennhager@ri.se
                                                                        Ericsson AB
                                                                        Anders Karlsson
                                                                        BURA DURA RP QRM
                                                                        Torshamnsgatan 21
                                                                        164 80 Stockholm

Radio measurements on Radio 4415 B2 B25 equipment
with FCC ID TA8AKRC161636 and IC: 287AB-AS161636

Product name: Radio 4415 B2 B25
Product number: KRC 161 636/1


RISE Research Institutes of Sweden AB
Electronics - EMC
Performed by                                                        Examined by




 Signature 1                                                         Signature 2


Tomas Lennhager                                                     Monika Fuller




RISE Research Institutes of Sweden AB
Postal address         Office location       Phone / Fax / E-mail         This report may not be reproduced other than in full, except
Box 857                Brinellgatan 4        +46 10 516 50 00             with the prior written approval of the issuing laboratory.
SE-501 15 BORÅS        SE-504 62 BORÅS       +46 33 13 55 02
Sweden                                       info@ri.se                                                                                  Accred. No. 1002
                                                                                                                                             Testing
                                                                                                                                          ISO/IEC 17025


REPORT                                                Date                     Reference                                          Page
                                                      2017-10-23               7P06127-WG                                         2 (27)




Summary ..................................................................................................................................... 3
Description of the test object ...................................................................................................... 4
Purpose of test ............................................................................................................................. 5
Operation modes during measurements ...................................................................................... 5
Conducted measurements ........................................................................................................... 5
Radiated measurements............................................................................................................... 5
References ................................................................................................................................... 5
Measurement equipment ............................................................................................................. 6
Uncertainties ............................................................................................................................... 6
Reservation ................................................................................................................................. 6
Delivery of test object ................................................................................................................. 6
Manufacturer’s representative..................................................................................................... 6
Test engineers ............................................................................................................................. 6
Test participant(-s) ...................................................................................................................... 6
Test frequencies used for radiated and conducted measurements............................................... 7
Test setup: conducted measurements .......................................................................................... 8
Test setup: radiated measurements.............................................................................................. 9
RF power output measurements according to CFR 47 §24.232 / IC RSS-133 6.4, conducted 11
   Test set-up and procedure ..................................................................................................... 11
   Results ................................................................................................................................... 11
   Remark .................................................................................................................................. 11
   Limits .................................................................................................................................... 12
Conducted spurious emission measurements according to CFR 47 §24.238 / IC RSS-133 6.2
................................................................................................................................................... 13
   Test set-up and procedure ..................................................................................................... 13
   Results ................................................................................................................................... 13
   Remark .................................................................................................................................. 13
   Limits .................................................................................................................................... 13
Field strength of spurious radiation measurements according to CFR 47 §2.1053 / IC RSS-133
6.5.............................................................................................................................................. 20
   Measurement equipment ....................................................................................................... 22
   Results ................................................................................................................................... 22
   Limits .................................................................................................................................... 22
Photos of test object .................................................................................................................. 25




RISE Research Institutes of Sweden AB


REPORT                           Date            Reference                Page
                                 2017-10-23      7P06127-WG               3 (27)




Summary
Standard Listed part of                                       Compliant
FCC CFR 47 part 24/ RSS 133, RSS-Gen

2.1046/ 6.4 RF power output, conducted                           Yes
2.1051/ 6.2 Spurious emission at antenna terminals               Yes
2.1053/ 6.5 Field strength of spurious radiation                 Yes




RISE Research Institutes of Sweden AB


REPORT                            Date           Reference                     Page
                                  2017-10-23     7P06127-WG                    4 (27)




Description of the test object
Equipment:                 Radio equipment Radio 4415 B2 B25
                           Product number KRC 161 636/1
                           FCC ID: TA8AKRC161636
                           IC: 287AB-AS161636

HVIN:                      AS161636

Hardware revision state:   R1B

Tested configuration:      Multi RAT WCDMA + GSM

Frequency range:           TX: 1930 – 1990 MHz
                           RX: 1850 – 1910 MHz

IBW:                       40 MHz

Output power:              Max 40 W/ antenna port

Antenna ports:             4 TX / 4 RX ports

Antenna:                   No dedicated antenna, handled during licensing

RF configurations:         WCDMA: 1-5 carriers/ port (max 11 carriers/ unit)
                           GSM: 1-4 carriers/ port (max 10 carriers/ unit)
                           Max 6 carriers/ port

                           WCDMA: TX Diversity, 2x(2x2) MIMO
                           GSM: Single antenna, dual TX

                           Contiguous Spectrum (CS), Non-Contiguous Spectrum (NCS)

Channel bandwidths:        WCDMA: 4.2 MHz and 5 MHz
                           GSM: 200 kHz

Modulations:               WCDMA: QPSK, 16QAM and 64QAM
                           GSM: GMSK, AQPSK and 8PSK

RF power Tolerance:        +0.6/ -2.5 dB

CPRI Speed                 Up to 10.1 Gbit/s

Nominal supply voltage: -48VDC


The information above is supplied by the manufacturer.




RISE Research Institutes of Sweden AB


REPORT                             Date            Reference                        Page
                                   2017-10-23      7P06127-WG                       5 (27)




Purpose of test
The purpose of the tests is to verify compliance to the performance characteristics specified in
applicable items of FCC CFR 47 Industry Canada RSS-133 and RSS-Gen.

Operation modes during measurements
WCDMA measurements were performed with the test object transmitting the Test model 1
which are defined in 3GPP TS 25.141. Test model 1 (TM1) represent QPSK modulation. Test
model 5 (TM5) includes the 16QAM modulation and Test model 6 (TM6) includes the
64QAM modulation.

GSM measurements were performed with the test object transmitting following modulations:
GMSK, AQPSK, 8-PSK.
Unless otherwise stated, all measurements were performed with the test object transmitting
pseudorandom data in all timeslots and settings for maximum transmitter output power
applicable for each configuration.

The measured configurations covers worst case settings.

Conducted measurements
The test object was supplied with -48 VDC by an external power supply. Additional
connections are documented in the set-up drawings for conducted measurements.

Radiated measurements
The test object was powered with -48 VDC by an external power supply. Additional
connections are documented in the set-up drawings for radiated measurements.

References
Measurements were done according to relevant parts of the following standards:
ANSI C63.4-2014
CFR 47 part 2, April 2017
CFR 47 part 24, April 2017
ANSI C63.26-2015
KDB 662911 D01 Multiple Transmitter Output v02r02
KDB 971168 D01 Power Meas License Digital Systems v02r02
KDB 971168 D03 IM Emission Repeater Amp v01
3GPP TS 25 141 version 13.6.0
3GPP TS 37.141, version 13.5.0
RSS-Gen Issue 4
RSS-133 Issue 6




RISE Research Institutes of Sweden AB


REPORT                               Date             Reference                         Page
                                     2017-10-23       7P06127-WG                        6 (27)




Measurement equipment
                                                          Calibration Due     RISE number
Test site Tesla                                               2019-12           503 881
R&S ESU 40                                                    2018-07           901 385
R&S FSQ 40                                                    2018-07           504 143
R&S FSW 43                                                    2018-08           902 073
Control computer with                                              -            BX62351
R&S software EMC32 version 10.20.01
High pass filter 3-26.5 GHz                                       2017-12        BX40074
High pass filter 3-26.5 GHz                                       2018-06        901 502
RF attenuator Weinschel WA73-20-11                                2018-05        900 691
Coaxial cable Sucoflex 102EA                                      2018-05        BX50191
Coaxial cable Sucoflex 102EA                                      2018-05        BX50236
ETS Lindgren BiConiLog Antenna 3142E                              2019-03        BX61914
EMCO Horn Antenna 3115                                            2019-12        502 175
µComp Nordic, Low Noise Amplifier                                 2017-12        901 545
Temperature and humidity meter, Testo 635                         2018-06        504 203
Temperature and humidity meter, Testo 625                         2018-06        504 188

Uncertainties
Measurement and test instrument uncertainties are described in the quality assurance
documentation ”SP-QD 10885”. The uncertainties are calculated with a coverage factor k=2
(95% level of confidence).
Compliance evaluation is based on a shared risk principle with respect to the measurement
uncertainty.

Reservation
The test results in this report apply only to the particular test object as declared in the report.

Delivery of test object
The test object was delivered: 2017-09-07.

Manufacturer’s representative
Mikael Jansson, Ericsson AB.

Test engineers
Tomas Isbring for radiated tests, RISE
Tomas Lennhager and Andreas Johnson for conducted tests, RISE.

Test participant(-s)
None.




RISE Research Institutes of Sweden AB


REPORT                           Date           Reference                  Page
                                 2017-10-23     7P06127-WG                 7 (27)




Test frequencies used for radiated and conducted measurements
TX test frequencies, conducted measurements:

Symbolic name: 2G1W
            Frequency     Bandwidth     Test model
              [MHz]        [MHz]
  GSM         1930.4         0.2          GMSK
  GSM         1931.0         0.2          GMSK
 WCDMA        1967.4         5.0           TM5

Symbolic name: 3G3W-L
            Frequency Bandwidth         Test model
              [MHz]    [MHz]
  GSM         1930.4     0.2              GMSK
 WCDMA        1932.8     5.0               TM5
  GSM         1947.8     0.2              GMSK
 WCDMA        1950.2     5.0               TM5
  GSM         1965.0     0.2              GMSK
 WCDMA        1967.4     5.0               TM5

Symbolic name: 3G3W-H
            Frequency Bandwidth         Test model
              [MHz]    [MHz]
  GSM         1950.6     0.2              GMSK
 WCDMA        1953.0     5.0               TM5
  GSM         1968.0     0.2              GMSK
 WCDMA        1970.4     5.0               TM5
  GSM         1985.2     0.2              GMSK
 WCDMA        1987.6     5.0               TM5

TX test frequencies, radiated measurements:

Symbolic name: 1W2G:
              Frequency Bandwidth       Test model
                [MHz]    [MHz]
 WCDMA          1972.4      5              TM5
  GSM           1989.4     0.2            GMSK
  GSM           1989.6     0.2            GMSK
According to FCC KDB 971168 D03

All RX frequencies were configured 80 MHz below the corresponding TX frequency
according the applicable duplex offset for the operating band.




RISE Research Institutes of Sweden AB


REPORT                          Date           Reference                      Page
                                2017-10-23     7P06127-WG                     8 (27)




Test setup: conducted measurements




Test object:
1. Radio 4415 B2 B25, KRC 161 636/1, rev. R1B, s/n: D16W963153
     With Radio Software: CXP 901 7316/7, rev. R67HA. FCC ID: TA8AKRC161636 and
     IC: 287AB-AS161636

Associated equipment:
2. Testing Equipment:
     CT10, LPC 102 467/1, rev. R1C, s/n: T01F375047, BAMS – 1001466801
     with software CXA 104 446/1, rev. R8AA

Functional test equipment:
 3. Computer, HP EliteBook 8560w, BAMS - 1001236851
 4. RF Attenuator: RISE number: 900 691
 5. Terminator, 50 ohm
 6. RISE Test Instrumentation according to measurement equipment list for each test.
    The signal analyzer was connected to the RISE 10 MHz reference standard during all
    measurements.




RISE Research Institutes of Sweden AB


REPORT                        Date          Reference                    Page
                              2017-10-23    7P06127-WG                   9 (27)




Test setup: radiated measurements




 1.   Radio 4415 B2 B25, KRC 161 636/1, rev. R1B, s/n: D16W963156
      With Radio Software: CXP 901 7316/7, rev. R67HA. FCC ID: TA8AKRC161636 and
      IC: 287AB-AS161636

Associated equipment:
2. Testing Equipment:
     CT10, LPC 102 467/1, rev. R1C, s/n: T01F375046, BAMS – 1001466800
     with software CXA 104 446/1, rev. R8AA

Functional test equipment:
 3. Computer, HP EliteBook 8560w, BAMS - 1001236854
 4. Attenuator
 5. R&S ESIB 26, RISE no: 503 292, for supervision purpose only
 6. ALD Control, Andrew, model: ATM200-A20, s/n: DESA101412073




RISE Research Institutes of Sweden AB


REPORT                             Date             Reference    Page
                                   2017-10-23       7P06127-WG   10 (27)




Interfaces:
 Power input configuration DC: -48 VDC                             Power
 RF A, 4.3-10 connector, combined TX/RX                            Antenna
 RF B, 4.3-10 connector, combined TX/RX                            Antenna
 RF C, 4.3-10 connector, combined TX/RX                            Antenna
 RF D, 4.3-10 connector, combined TX/RX                            Antenna
 1, Optical Interface Link, single mode opto fibre                 Signal
 2, Optical Interface Link, not used in this configuration         Signal
 EXT Alarm, shielded multi-wire                                    Signal
 ALD, shielded multi-wire                                          Signal
 Ground wire                                                       Ground




RISE Research Institutes of Sweden AB


REPORT                             Date             Reference                        Page
                                   2017-10-23       7P06127-WG                       11 (27)




RF power output measurements according to CFR 47 §24.232 /
IC RSS-133 6.4, conducted
Date                            Temperature                     Humidity
        2017-10-15                    23 °C ± 3 °C                     36 % ± 5 %

Test set-up and procedure

The test object was connected to a signal analyser measuring peak and RMS output power in
CDF mode. A resolution bandwidth of 80 MHz was used.

Measurement equipment                                           RISE number
R&S FSW 43                                                      902 073
RF attenuator                                                   900 691
Testo 635, temperature and humidity meter                       504 203

Measurement uncertainty: 1.1 dB

Results

Rated output power at RF connector 46 dBm/ port.
                                 Output power CCDF [RMS dBm/ PAR dB]
Symbolic name     Port RF A        Port RF B     Port RF C        Port RF D    Total power1)
     2G1W         44.80/ 6.60      44.96/ 6.58   44.93/ 6.58     44.92/ 6.58      50.92
   3G3W-L        45.52/ 7.54 45.64/ 7.54 45.50/ 7.54 45.49/ 7.56        51.56
1)
 : summed output power according to FCC KDB662911 Multiple transmitter output.
Note: The PAR value is the 0.1 % Peak to Average Ratio.

Remark

ERP/EIRP compliance is addressed at the time of licensing, as required by the responsible
FCC/IC Bureau(s). Licensee’s are required to take into account maximum antenna gain used in
combination with above power settings to prevent the radiated output power to exceed the
limits.




RISE Research Institutes of Sweden AB


REPORT                             Date            Reference                       Page
                                   2017-10-23      7P06127-WG                      12 (27)




Limits

§24.232     The maximum output power may not exceed 3280 W/MHz (EIRP).
            The Peak to Average Ratio (PAR) may not exceed 13 dB.

RSS-133 Base station transmitters operating in the band 1930-1990 MHz shall not have
        output power exceeding 100 watts. When the transmitter power is measured in
        terms of average value, the peak-to-average ratio(PAR) of the power shall not
        exceed 13 dB

            There is no EIRP limit specified for base station equipment in the RSS-133.

            EIRP compliance is addressed at the time of licensing, as required by the
            responsible IC Bureau. Licensee’s are required to take into account the antenna
            gain to get the maximum usable power settings to prevent the radiated output
            power to exceed the EIRP limits specified in SRSP-510


Complies?                                    Yes




RISE Research Institutes of Sweden AB


REPORT                             Date             Reference                        Page
                                   2017-10-23       7P06127-WG                       13 (27)




Conducted spurious emission measurements according to
CFR 47 §24.238 / IC RSS-133 6.2
Date                           Temperature                      Humidity
         2017-10-15                  23 °C ± 3 °C                      36 % ± 5 %

Test set-up and procedure

The measurements were made per definition in §24.238. The output was connected to a
spectrum analyzer with a RBW setting of 1 MHz and RMS detector activated. The spectrum
analyzer was connected to an external 10 MHz reference standard during the measurements.

Before comparing the results to the limit, 6 dB [10 log (4)] to cover 2x(2x2) MIMO, should
be added according to method c “measure and add 10 log(NANT)” of FCC KDB662911 D01
Multiple Transmitter Output.

Measurement equipment                                           RISE number
R&S FSW 43                                                      902 073
RF attenuator                                                   900 691
HP filter                                                       BX40074
Testo 635, temperature and humidity meter                       504 203

Measurement uncertainty: 3.7 dB

Results

    Diagram            Symbolic name          Tested Port
     1 a-b-c                2G1W                 RF B
     2 a-b-c               3G3W-L                RF B
     3 a-b-c               3G3W-H                RF B
Note: Measurements were mainly limited to port RF B due to electrical identical ports
as declared by the client.

Remark

The emission at 9 kHz on the plots was not generated by the test object. A complementary
measurement with a smaller RBW showed that it was related to the LO feed-through.

The highest fundamental frequency is 1990 MHz. The measurements were made up to 20 GHz
(10x1990 MHz = 19900 MHz).


Limits

CFR 47 §24.238 and RSS-133 6.5

Outside a licensee's frequency band(s) of operation the power of any emission shall be
attenuated below the transmitter power (P) by at least 43 + 10 log (P) dB, resulting in a limit of
-13 dBm per 1 MHz RBW.

Complies?                                    Yes


RISE Research Institutes of Sweden AB


REPORT                           Date            Reference                     Page
                                 2017-10-23      7P06127-WG                    14 (27)




Diagram 1a:




Diagram 1b:




Note:   Due to the use of reduced measurement bandwidth the limit should be adjusted by 10
        dB to -23 dBm.




RISE Research Institutes of Sweden AB


REPORT                        Date         Reference    Page
                              2017-10-23   7P06127-WG   15 (27)




Diagram 1 c:




RISE Research Institutes of Sweden AB


REPORT                           Date            Reference                     Page
                                 2017-10-23      7P06127-WG                    16 (27)




Diagram 2a:




Diagram 2b:




Note:   Due to the use of reduced measurement bandwidth the limit should be adjusted by 10
        dB to -23 dBm.




RISE Research Institutes of Sweden AB


REPORT                        Date         Reference    Page
                              2017-10-23   7P06127-WG   17 (27)




Diagram 2 c:




RISE Research Institutes of Sweden AB


REPORT                           Date            Reference                     Page
                                 2017-10-23      7P06127-WG                    18 (27)




Diagram 3a:




Diagram 3b:




Note:   Due to the use of reduced measurement bandwidth the limit should be adjusted by 10
        dB to -23 dBm.




RISE Research Institutes of Sweden AB


REPORT                        Date         Reference    Page
                              2017-10-23   7P06127-WG   19 (27)




Diagram 3 c:




RISE Research Institutes of Sweden AB


REPORT                             Date            Reference                        Page
                                   2017-10-23      7P06127-WG                       20 (27)




Field strength of spurious radiation measurements according to
CFR 47 §2.1053 / IC RSS-133 6.5
Date                          Temperature                      Humidity
        2017-09-14                  22 °C ± 3 °C                      45 % ± 5 %
        2017-10-04                  23 °C ± 3 °C                      38 % ± 5 %
        2017-10-05                  22 °C ± 3 °C                      34 % ± 5 %

The test site conform to the site validation criterion specified in ANSI C63.4 2014. The test
site complies with RSS-Gen, Industry Canada file no. 3482A-1.

The measurements were performed with both horizontal and vertical polarization of the
antenna. The antenna distance was 3 m in the frequency range 30 MHz – 18 GHz and 1 m
in the frequency range 18 GHz – 20 GHz.

RF absorbers were covering a floor area in the frequency range 1 GHz – 18 GHz to comply
with site validation requirements according to ANSI C63.4-2014.

The EUT was placed 0.8 m above reference ground plane in frequency range 30 MHz – 1
GHz and 1.5 m above reference ground plane in frequency range 1 GHz – 20 GHz.

The measurement was performed with a RBW of 1 MHz.

A propagation loss in free space was calculated. The used formula was
            4 D  , is the propagation loss and is the antenna distance.
  20 log                                       D
             
The measurement procedure was as the following:
1. A pre-measurement is performed with peak detector. For measurement < 1 GHz the
    test object was measured in eight directions with the antenna at three heights, 1.0 m,
    1.5 m and 2.0 m. For measurements > 1 GHz the test object was measured in seventeen
    directions with the antenna height 1.0 m, 1.5 m and 2m.
2. Spurious radiation on frequencies closer than 20 dB to the limit in the pre-measurement
    is scanned 0-360 degrees and the antenna is scanned 1- 4 m for maximum response.
    The emission is then measured with the RMS detector and the RMS value is reported.
    Frequencies closer than 10 dB to the limit when measured with the RMS detector were
    measured with the substitution method according to ANSI 63.26.




RISE Research Institutes of Sweden AB


REPORT                            Date            Reference                       Page
                                  2017-10-23      7P06127-WG                      21 (27)




The test set-up during the spurious radiation measurements is shown in the picture below:
30-1000 MHz




1-18GHz




RISE Research Institutes of Sweden AB


REPORT                             Date              Reference                       Page
                                   2017-10-23        7P06127-WG                      22 (27)




Measurement equipment

Measurement equipment                                            RISE number
Semi anechoic chamber Tesla                                      503 881
R&S ESU 40                                                       901 385
EMC 32 ver. 10.20.01                                             BX62351
ETS Lindgren BiConiLog 3142E                                     BX61914
ETS Lindgren Horn Antenna 3115                                   502 175
Flann STD Gain Horn Antenna 20240-20                             503 674
µComp Nordic, Low Noise Amplifier                                901 545
Miteq, Low Noise Amplifier                                       503 278
HP Filter 3-26.5 GHz                                             901 502
Temperature and humidity meter, Testo 625                        504 188

Results

Tested configurations: 1W2G

representing worst case: Symbolic name 1W2G, Diagram 1 a-d


                                      Spurious emission level (dBm)

 Frequency                   Vertical                                  Horizontal
   (MHz)

  30-20000      All emission > 20 dB below limit         All emission > 20 dB below limit


Measurement uncertainty: 3.1 dB

Limits

CFR 47 §24.238 and IC RSS-133 6.5

(g) Outside a licensee's frequency band(s) of operation the power of any emission shall be
attenuated below the transmitter power (P) by at least 43 + 10 log (P) dB, resulting in a limit of
-13 dBm.


Complies?                                      Yes




RISE Research Institutes of Sweden AB


REPORT                                        Date             Reference                      Page
                                              2017-10-23       7P06127-WG                     23 (27)




Diagram 1a:

                      0


                     -10                                                                      FCC P2


                     -20


                     -30
      Level in dBm




                     -40


                     -50


                     -60


                     -70



                      30M    50   60      80    100M               200     300   400    500   800     1G
                                                        Frequency in Hz




Diagram 1b:

                      0


                     -10                                                                      FCC P2


                     -20


                     -30
      Level in dBm




                     -40


                     -50


                     -60


                     -70



                      1000             1500                 2000                 2500                3000
                                                       Frequency in MHz


Note: The emission between 1970 - 1990 MHz are the carrier frequencies and shall be ignored
      in the context.




RISE Research Institutes of Sweden AB


REPORT                                     Date                Reference                          Page
                                           2017-10-23          7P06127-WG                         24 (27)




Diagram 1c:

                      0


                     -10                                                                          FCC P2


                     -20


                     -30
      Level in dBm




                     -40


                     -50


                     -60


                     -70



                       3G                 5G      6       7        8       9   10G                       18G
                                                      Frequency in Hz




Diagram 1d:

                      0


                     -10                                                                              FCC P2


                     -20


                     -30
      Level in dBm




                     -40


                     -50


                     -60


                     -70



                       18   18,2   18,4   18,6    18,8        19       19,2      19,4   19,6   19,8       20
                                                      Frequency in GHz




RISE Research Institutes of Sweden AB


REPORT                        Date           Reference    Page
                              2017-10-23     7P06127-WG   25 (27)




Photos of test object
Front side                              Rear side




Left side                               Right side




RISE Research Institutes of Sweden AB


REPORT                        Date         Reference    Page
                              2017-10-23   7P06127-WG   26 (27)




Bottom side




Top side




RISE Research Institutes of Sweden AB


REPORT                        Date         Reference    Page
                              2017-10-23   7P06127-WG   27 (27)




Labels:

Radiated measurements:

Radio label:




SFP module:




Conducted measurements:

Radio label:




SFP module:




RISE Research Institutes of Sweden AB



Document Created: 2017-10-23 13:59:06
Document Modified: 2017-10-23 13:59:06

© 2024 FCC.report