MPE report

FCC ID: TA8AKRC161489-1

RF Exposure Info

Download: PDF
FCCID_3034814

                 REPORT
                 issued by an FCC listed Laboratory Reg. no. 93866.
                 The test site complies with RSS-Gen, file no: IC 3482A

                 Contact person                                           Date                   Reference                          Page
                 Tomas Lennhager                                          2016-06-10 6P03968-MPE                                    1 (2)
                 Electronics
                 +46 10 516 54 09
                 Tomas.Lennhager@sp.se

                                                                          Ericsson AB
                                                                          Anders Karlsson
                                                                          PDU HW
                                                                          Torshamnsgatan 21
                                                                          164 83 Stockholm

MPE test on Ericsson Radio 2203 B2 B25
(4 appendices)

Test object

Product name: Radio 2203 B2 B25
Product number: KRC 161 489/1

See appendix 1 for the tested hardware configuration and general information.
See appendix 4 for photos.

Summary

Standard                                                                                         Compliant Appendix Remarks
CFR 47 part 2.1091 Radiofrequency radiation                                                                                   2                   -
                                                                                                       Yes
exposure evaluation: mobile devices
RSS-102 Radio Frequency Exposure compliance of
                                                                                                       Yes                    2                   -
Radio communication Apparatus
OET Bulletin 65/ KDB 447498                                                                            Yes                    2                   -




SP Technical Research Institute of Sweden
Electronics - EMC
Performed by                                                                     Examined by




__Signature_1                                                                    __Signature_2

Tomas Isbring                                                                    Anders Nordlöf




SP Technical Research Institute of Sweden
Postal address             Office location              Phone / Fax / E-mail          This document may not be reproduced other than in full, except with the
SP                         Västeråsen                   +46 10 516 50 00              prior written approval of SP.
Box 857                    Brinellgatan 4               +46 33 13 55 02
SE-501 15 BORÅS            SE-504 62 BORÅS              info@sp.se
Sweden


                                            Date      Reference                Page
            REPORT
                                            2016-06-10 6P03968-MPE             2 (2)




Table of contents

Purpose of test                                                   Appendix 1

Description of the test object                                    Appendix 1

Tested configuration                                              Appendix 1

Operational test mode                                             Appendix 1

Measurement equipment                                             Appendix 1

Test facility                                                     Appendix 1

Uncertainties                                                     Appendix 1

Reservation                                                       Appendix 1

Delivery of test object                                           Appendix 1

Test engineers                                                    Appendix 1

Test participant                                                  Appendix 1

RF exposure evaluation                                            Appendix 2

Hardware list                                                     Appendix 3

Photos of test object                                             Appendix 4




SP Technical Research Institute of Sweden


                                            Date         Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE               1 (5)


                                                         Appendix 1



Purpose of test

The tests were performed to verify that the radiofrequency exposure of the Radio meets the
requirements of CFR 47 part 2.1091 and RSS-102.

References

Measurements were done according to relevant parts of the following standards:

CFR 47 part 2, 2015
RSS-102 Issue 5
3GPP TS 25.141, version 13.0.0
3GPP TS 36.141, version 11.11.0
KDB 447498 D01 General RF Exposure Guidance v06
OET Bulletin 65 1997

Description of the test object

The test object is a Remote Radio Unit (Radio 2203 B2 B25) for a LTE and WCDMA base
station and designed to provide mobile users with a connection to a mobile network.




SP Technical Research Institute of Sweden


                                             Date           Reference             Page
            REPORT
                                             2016-06-10 6P03968-MPE               2 (5)


                                                            Appendix 1



Tested configuration

RF configuration:
Antenna port A:        1x 37.0 dBm (5 W)
Antenna port B:        1x 37.0 dBm (5 W)
SFP module:            See appendix 4 for details
OIL:                   Opto fibre, single mode, 10 Gbit/s
Power configuration:   -48 VDC

Operational test mode

LTE:
The test object was activated for maximum transmit power. E-TM1.1 as defined in ETSI TS
136 141/ 3GPP TS 36.141 was used in all cells.

The test object was configured with both RF paths allocated to the following frequency:

Frequency                             Comment
  [MHz]
  1930.7    TX bottom frequency in 1.4 MHz BW configuration
  1931.5    TX bottom frequency in 3 MHz BW configuration
  1932.5    TX bottom frequency in 5 MHz BW configuration
  1935.0    TX bottom frequency in 10 MHz BW configuration
  1937.5    TX bottom frequency in 15 MHz BW configuration
  1940.0    TX bottom frequency in 20 MHz BW configuration
  1962.5    TX mid frequency in 1.4 MHz - 20 MHz BW configurations
  1985.0    TX top frequency in 20 MHz BW configuration
  1987.5    TX top frequency in 15 MHz BW configuration
  1990.0    TX top frequency in 10 MHz BW configuration
  1992.5    TX top frequency in 5 MHz BW configuration
  1993.5    TX top frequency in 3 MHz BW configuration
  1994.3    TX top frequency in 1.4 MHz BW configuration

WCDMA:
The test object was activated for maximum transmit power. TM 1 (SF=128) as defined in
ETSI TS 125 141/ 3GPP TS 25.141 was used in all cells. The channel type “3GPP Reference
channel 12.2 ksps slotformat 10” was used in all cells.

The test object was configured with both RF paths allocated to the following frequency:

Frequency                 Comment
  [MHz]
  1932.4 TX bottom frequency
  1962.6 TX mid frequency
  1992.6 TX top frequency

All RX frequencies were configured 80 MHz below the corresponding TX frequency
according to the applicable duplex offset for the operating band.




SP Technical Research Institute of Sweden


                                               Date      Reference            Page
            REPORT
                                               2016-06-10 6P03968-MPE         3 (5)


                                                         Appendix 1



Test setup:




Test object:
1. Radio 2203 B2 B25 with antenna, see appendix 3 for details

Associated equipment:
2. Testing Equipment:
     CT10, LPC 102 487/1, rev. R1C, s/n: T01F375047, BAMS – 1001466801
     with software CXA 104 446/1, rev. R8M01/7

Functional test equipment:
 3. HP EliteBook 8560w, BAMS – 1001236851

 Interface:                                                             Type of port:
 Power: 120 VAC, 60 Hz                                                  AC Power
 1, optical interface                                                   Signal
 2, optical interface, not used in this configuration                   Signal
 Ext Alarm                                                              Signal
 Ground wire                                                            Ground




SP Technical Research Institute of Sweden


                                              Date            Reference                 Page
           REPORT
                                              2016-06-10 6P03968-MPE                    4 (5)


                                                              Appendix 1



Measurement equipment

                                                       Calibration Due          SP number
Test site Tesla                                            2017-01                 503 881
Measurement software: Antennkalibrering V1.24                   -                     -
Calculation software: EMF V1.5                                  -                     -
Laser probe AR FL7018                                      2017-03                 902 280
Testo 625 Temperature and humidity meter                   2017-06                 504 188

Test facility

The used test site (503 881) is compliant with the requirements of section 2.948 of the FCC rules
and listed, registration number 93866, as a facility accepted for certification under parts 15 and
18. The site complies with RSS-Gen, Issue 4 and is accepted by Industry Canada for the
performance of radiated measurements, file no: IC 3482A-1.

Uncertainties

Measurement and test instrument uncertainties are described in the quality assurance
documentation ”SP-QD 10885”. The measurement uncertainties can be found in the table
below. The uncertainties are calculated with a coverage factor k=2 (95% level of confidence).

Standard                 Method                                           Uncertainty
RSS-102                  RF exposure evaluation                           10 %, Note

Note: Stated uncertainty refers to the calculated distance.

Compliancy evaluation is based on a shared risk principle with respect to the measurement
uncertainty.




SP Technical Research Institute of Sweden


                                                Date          Reference                 Page
            REPORT
                                                2016-06-10 6P03968-MPE                  5 (5)


                                                              Appendix 1



Reservation

The test results in this report apply only to the particular test object as declared in the report.

Delivery of test object

The test object was delivered: 2016-05-06.

Test engineers

Tomas Isbring and Rolf Kühn, SP.

Test participant

None.




SP Technical Research Institute of Sweden


                                              Date           Reference                Page
            REPORT
                                              2016-06-10 6P03968-MPE                  1 (16)


                                                             Appendix 2



RF exposure evaluation: 2.1091 Mobile devices / RSS-102 4.2

Date                           Temperature                     Humidity
         2016-05-12                  23 °C ± 3 °C                     21 % ± 5 %
         2016-05-13                  23 °C ± 3 °C                     31 % ± 5 %
         2016-05-16                  23 °C ± 3 °C                     25 % ± 5 %
         2016-05-17                  23 °C ± 3 °C                     34 % ± 5 %

Procedure

Systems operating under the provisions of this section shall be operated in a manner that ensures
that the public is not exposed to radio frequency energy levels in excess limit for maximum
permissible exposure. In accordance with RSS-102 this device has been defined as a mobile
device whereby a distance of at least 20 cm normally can be maintained between the user and
the device.

Test setup and procedure

The test object is measured in twelve directions (in 30° steps) with the field probe continuously
scanning from 0.1 – 2 m in height.

Measuring distance was 20 cm from the surface of the test object, step 1 is repeated with a
distance increment of 20 cm until the measured field strength is compliant.

The measurements were scaled according to:
 1. Highest possible output power with respect to the declared tolerance.

  2.   Field probe characteristics with respect to the modulated signal at different levels of the
       field strength.

The nominal power for each antenna port stated by the manufacturer is 5 W (total power: 10 W),
with a tolerance of +0.6 dB/ -2.0 dB. The measured output power was as follows for the worst
case configurations:
LTE 1.4 MHz, TX top frequency:          4.9 W (36.9 dBm)
LTE 3 MHz, TX mid frequency:            4.8 W (36.8 dBm)
LTE 20 MHz, TX mid frequency:           4.9 W (36.9 dBm)
WCDMA, TX bottom frequency:             4.9 W (36.9 dBm)
WCDMA, TX mid frequency:                4.8 W (36.8 dBm)

The measurements were therefore adjusted by the following corrections to cover the highest
possible output power:
LTE 1.4 MHz, TX top frequency:        0.7 dBm
LTE 3 MHz, TX mid frequency:          0.8 dBm
LTE 20 MHz, TX mid frequency:         0.7 dBm
WCDMA, TX bottom frequency:           0.7 dBm
WCDMA, TX mid frequency:              0.8 dBm

The measurement were made with an Integrated antenna and with Semi-integrated omni
antennas.
The distance for compliance for Adult is derived from spatial average over the full scan height.
The distance for compliance for Child is derived from spatial average over ± 45 cm from the
height where the highest level was detected.

SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   2 (16)


                                                      Appendix 2



Test setup, Integrated antenna KRE 101 2249/1:




Test setup, Semi-integrated omni antenna KRE 101 2233/1:




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   3 (16)


                                                      Appendix 2



Test setup, Semi-integrated omni antenna KRE 101 2245/1:




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                4 (16)


                                                          Appendix 2



Results

Integrated antenna KRE 101 2249/1, worst case: LTE BW 20 MHz, TX mid frequency.
Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         67.2                  107.3
        30°         46.6                   82.9
        60°         20.0                   21.3
        90°         20.0                   20.0
      120°          20.0                   20.0
      150°          20.0                   20.0
      180°          20.0                   20.0
      210°          20.0                   20.0
      240°          20.0                   20.0
      270°          20.0                   20.0
      300°          20.0                   20.0
      330°          46.5                   83.1

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 0.46606 mW/cm2 for LTE BW 20 MHz,
      TX mid frequency.



SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                5 (16)


                                                          Appendix 2




Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         33.4                  62.0
        30°         27.5                  43.0
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  20.0
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  20.0
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          21.9                  43.0

Note: The distance for compliance of every direction in the table above is calculated from the
chassis of the test object. The limit level was 1.0 mW/cm2 for LTE BW 20 MHz, TX mid
frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                6 (16)


                                                          Appendix 2



Integrated antenna KRE 101 2249/1, worst case: WCDMA, TX bottom frequency

Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         72.5                  115.5
        30°         50.6                   88.6
        60°         20.0                   21.1
        90°         20.0                   20.0
      120°          20.0                   20.0
      150°          20.0                   20.0
      180°          20.0                   20.0
      210°          20.0                   20.0
      240°          20.0                   20.0
      270°          20.0                   20.0
      300°          20.0                   23.5
      330°          51.3                   88.4

Note: The distance for compliance of every direction in the table above is calculated from the
chassis of the test object. The limit level was 0.461163 mW/cm2 for WCDMA, TX bottom
frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                7 (16)


                                                          Appendix 2



Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         33.5                  65.6
        30°         20.0                  45.7
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  20.0
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  20.0
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          22.6                  48.3

Note: The distance for compliance of every direction in the table above is calculated from the
chassis of the test object. The limit level was 1.0 mW/cm2 for WCDMA, TX bottom frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                8 (16)


                                                          Appendix 2




Semi-integrated omni antenna KRE 101 2233/1, worst case: LTE 3 MHz, TX mid frequency.

Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  28.3
        30°         20.0                  30.0
        60°         20.0                  34.5
        90°         20.0                  28.2
      120°          26.2                  39.3
      150°          20.0                  35.2
      180°          20.0                  33.5
      210°          20.0                  36.1
      240°          26.0                  40.4
      270°          20.0                  27.7
      300°          20.0                  36.0
      330°          20.0                  29.6

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 0.46606 mW/cm2 for LTE BW 3 MHz, TX
      mid frequency.


SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                9 (16)


                                                          Appendix 2



Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  20.0
        30°         20.0                  20.0
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  24.3
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  23.9
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          20.0                  20.0

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 1.0 mW/cm2 for LTE BW 3 MHz, TX mid
      frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                10 (16)


                                                          Appendix 2



Semi-integrated omni antenna KRE 101 2233/1, worst case: WCDMA, TX bottom frequency

Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  27.5
        30°         20.0                  30.5
        60°         20.0                  35.1
        90°         20.0                  27.6
      120°          26.2                  39.1
      150°          20.2                  34.8
      180°          20.0                  34.3
      210°          20.2                  35.3
      240°          26.0                  39.2
      270°          20.0                  28.2
      300°          20.0                  35.4
      330°          20.0                  30.0

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 0.461163 mW/cm2 for WCDMA, TX
      bottom frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                11 (16)


                                                          Appendix 2



Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  20.0
        30°         20.0                  20.0
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  24.2
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  23.6
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          20.0                  20.0

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 1.0 mW/cm2 for WCDMA, TX bottom
      frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                12 (16)


                                                          Appendix 2



Semi-integrated omni antenna KRE 101 2245/1, worst case: LTE 1.4 MHz, TX top frequency.

Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  30.1
        30°         20.0                  30.7
        60°         20.0                  36.8
        90°         20.0                  30.3
      120°          26.6                  40.6
      150°          21.3                  37.6
      180°          20.0                  35.5
      210°          21.1                  39.7
      240°          25.8                  40.9
      270°          20.0                  29.5
      300°          20.5                  36.7
      330°          20.0                  30.8

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 0.471208 mW/cm2 for LTE BW 1.4 MHz,
      TX top frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                13 (16)


                                                          Appendix 2



Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  20.0
        30°         20.0                  20.0
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  25.4
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  24.2
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          20.0                  20.0

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 1.0 mW/cm2 for LTE BW 1.4 MHz, TX
      top frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                14 (16)


                                                          Appendix 2



Semi-integrated omni antenna KRE 101 2245/1, worst case: WCDMA, TX mid frequency

Distance for compliance according to RSS-102:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  29.2
        30°         20.0                  32.2
        60°         20.0                  37.7
        90°         20.0                  30.2
      120°          27.4                  42.2
      150°          21.4                  37.3
      180°          20.0                  32.6
      210°          20.7                  37.4
      240°          26.2                  41.1
      270°          20.0                  29.9
      300°          21.5                  37.7
      330°          20.0                  32.9

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 0.466076 mW/cm2 for WCDMA, TX mid
      frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
           REPORT
                                            2016-06-10 6P03968-MPE                15 (16)


                                                          Appendix 2



Distance for compliance according to 47 CFR 1.1310:




Note: The test object was placed with the front side facing 0° as shown in the test setup photo.

                    Distance for compliance (cm).
  Direction         Adult                 Child
         0°         20.0                  20.0
        30°         20.0                  20.0
        60°         20.0                  20.0
        90°         20.0                  20.0
      120°          20.0                  26.2
      150°          20.0                  20.0
      180°          20.0                  20.0
      210°          20.0                  20.0
      240°          20.0                  24.5
      270°          20.0                  20.0
      300°          20.0                  20.0
      330°          20.0                  20.0

Note: The distance for compliance of every direction in the table above is calculated from the
      chassis of the test object. The limit level was 1.0 mW/cm2 for WCDMA, TX mid
      frequency.




SP Technical Research Institute of Sweden


                                            Date          Reference               Page
            REPORT
                                            2016-06-10 6P03968-MPE                16 (16)


                                                          Appendix 2



Limits

According to 47 CFR 1.1310.

((B) Limits for General Population/Uncontrolled Exposure
 Frequency range      Electric field   Magnetic field    Power density         Averaging time
      (MHz)              strength          strength      [S] (mW/cm2)           |E|2. |H|2 or S
                        [E] (V/m)        [H] (A/m)                                (minutes)
   1500-100000               -                 -               1                   (Note 1)

According to RSS-102 Table 4

RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment)
 Frequency range     Electric field    Magnetic field     Power density      Averaging time
     (MHz)              strength           strength         [S] (W/m2)        |E|2. |H|2 or S
                       [E] (V/m)         [H] (A/m)                              (minutes)
    300-6000                -                  -           0.02619f0.6834        (Note 1)

f = frequency in MHz.

Note 1: The test was executed with the test object configured for continuous transmission with
        maximum output power setting to represent worst case. Therefore no averaging time
        measurement was made.


Complies?                                   Yes




SP Technical Research Institute of Sweden


                                             Date           Reference            Page
            REPORT
                                             2016-06-10 6P03968-MPE              1 (1)


                                                            Appendix 3



Hardware list

         Product name              Product number         R-state        Serial number
       Radio 2203 B2 B25            KRC 161 489/1          R1D            C82A522331
          PSU AC 10                 BML 901 350/1          R1B           BW9A400553
          FAN UNIT                  BKV 106 176/2          R2B           CE51000UEM

Antennas:
             Product name                           Product number R-state Serial number
             Antenna 6503                           KRE 101 2249/1 R1C      D775310040
 VPol Omni 790-960/ 1710-2700 (rightside)           KRE 101 2233/1    -     DEI4027800
 VPol Omni 790-960/ 1710-2700 (leftside)            KRE 101 2233/1    -     DEI4027744
 VPol Omni 694-894/ 1710-2700 (rightside)           KRE 101 2245/1    -     DEI4432219
 VPol Omni 694-894/ 1710-2700 (leftside)            KRE 101 2245/1    -     DEI4432235

SFP modules:
                                                          Product number
Product name Product number Manufacturer                                  Serial number
                                                          of Manufacturer
      SFP         RDH 102 65/3          Finisar         FTLX1471D3BTL-E7    AM9041L

Radio software:
         Product number                     Revision
          CXP 901 7316/2                    R62EU




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   1 (5)


                                                      Appendix 4



Photos of test object

Front side of Radio 2203 B2 B25




PSU AC 10 and FAN UNIT:




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   2 (5)


                                                      Appendix 4



Front side with integrated antenna KRE 101 2249/1




Front side with omni antenna KRE 101 2233/1




Front side with omni antenna KRE 101 2245/1




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   3 (5)


                                                      Appendix 4



Radio label:




PSU AC 10 label:




FAN UNIT label:




SFP module:




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   4 (5)


                                                      Appendix 4



Integrated antenna KRE 101 2249/1 label:




Semi-integrated omni antenna KRE 101 2233/1 labels:
Rightside antenna:




Leftside antenna:




SP Technical Research Institute of Sweden


                                            Date      Reference      Page
           REPORT
                                            2016-06-10 6P03968-MPE   5 (5)


                                                      Appendix 4



Semi-integrated omni antenna KRE 101 2245/1 labels:
Rightside antenna:




Leftside antenna:




SP Technical Research Institute of Sweden



Document Created: 2016-06-10 15:28:41
Document Modified: 2016-06-10 15:28:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC