03 FCC Test Report_DCD

FCC ID: T8VCL6

Test Report

Download: PDF
FCCID_3522953

                                                                                  Test report No.    : 11766072H-A-R1
                                                                                  Page               : 1 of 17
                                                                                  Issued date        : August 22, 2017
                                                                                  FCC ID             : T8VCL6




                            RADIO TEST REPORT
                             Test Report No. : 11766072H-A-R1
        Applicant                         :    ASAHI DENSO CO., LTD.

        Type of Equipment                 :    Steering Lock

        Model No.                         :    CL6

        FCC ID                            :    T8VCL6

        Test regulation                   :    FCC Part 15 Subpart C: 2017

        Test Result                       :    Complied

           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or endorsement
                by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues such as Manual
                or non-Radio test related Requirements. (if applicable)
           7.   This report is a revised version of 11766072H-A.

                        Date of test:                         June 27, 2017

                        Representative test
                        engineer:
                                                             Yuta Moriya
                                                               Engineer
                                                      Consumer Technology Division


                        Approved by:
                                                            Motoya Imura
                                                               Engineer
                                                      Consumer Technology Division

                                                       This laboratory is accredited by the NVLAP LAB CODE
                                                       200572-0, U.S.A. The tests reported herein have been
                                                       performed in accordance with its terms of accreditation.
                                                       *As for the range of Accreditation in NVLAP, you may
                                                       refer to the WEB address,
                                                       http://japan.ul.com/resources/emc_accredited/

      NVLAP LAB CODE: 200572-0



UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124                                                                  13-EM-F0429


                                                                        Test report No.   : 11766072H-A-R1
                                                                        Page              : 2 of 17
                                                                        Issued date       : August 22, 2017
                                                                        FCC ID            : T8VCL6




                                  REVISION HISTORY
                               Original Test Report No.: 11766072H-A

Revision     Test report No.          Date            Page      Contents
                                                      revised
-            11766072H-A              July 25, 2017   -         -
(Original)
1            11766072H-A-R1           August 22,      P.9       Addition of the following sentence;
                                      2017                      “Also, it was confirmed that there were no
                                                                differences in the noise levels and bandwidth
                                                                of EUT regardless of with or without
                                                                transponder.”
1            11766072H-A-R1           August 22,      P.11      typo of RBW value in SECTION 6
                                      2017




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                        Test report No.        : 11766072H-A-R1
                                                                                                        Page                   : 3 of 17
                                                                                                        Issued date            : August 22, 2017
                                                                                                        FCC ID                 : T8VCL6


CONTENTS                                                                                                                                  PAGE

SECTION 1: Customer information ..................................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ........................................................................................ 4
SECTION 3: Test specification, procedures & results ........................................................................ 5
SECTION 4: Operation of E.U.T. during testing ................................................................................. 8
SECTION 5: Radiated emission (Fundamental and Spurious Emission) .......................................... 9
SECTION 6: -26dB Bandwidth ............................................................................................................ 11
SECTION 7: 99% Occupied Bandwidth ............................................................................................. 11
APPENDIX 1: Test data ....................................................................................................................... 12
  Radiated Emission below 30 MHz (Fundamental and Spurious Emission) ................................ 12
  Radiated Emission above 30 MHz (Spurious Emission) ................................................................ 13
  -26 dB Bandwidth and 99 % Occupied Bandwidth ....................................................................... 14
APPENDIX 2: Test instruments .......................................................................................................... 15
APPENDIX 3: Photographs of test setup ............................................................................................ 16
  Radiated Emission ............................................................................................................................. 16
  Worst Case Position .......................................................................................................................... 17




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.   : 11766072H-A-R1
                                                                                  Page              : 4 of 17
                                                                                  Issued date       : August 22, 2017
                                                                                  FCC ID            : T8VCL6


SECTION 1: Customer information
Company Name                            :     ASAHI DENSO CO., LTD.
Address                                 :     6-2-1 Somejidai, Hamakita-ku, Hamamatsu, Shizuoka 434-0046, Japan
Telephone Number                        :     +81-53-586-7383
Facsimile Number                        :     +81-53-584-1589
Contact Person                          :     Tomohiro Yaguchi



SECTION 2: Equipment under test (E.U.T.)

2.1      Identification of E.U.T.

Type of Equipment                       :     Steering Lock
Model No.                               :     CL6
Serial No.                              :     Refer to Clause 4.2
Rating                                  :     DC 12.0 V
Receipt Date of Sample                  :     May 23, 2017
Country of Mass-production              :     Japan
Condition of EUT                        :     Production prototype
                                              (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                     :     No Modification by the test lab


2.2      Product Description

Model: CL6 (referred to as the EUT in this report) is a Steering Lock.

General Specification
Clock frequency(ies) in the system      :     4 MHz (LF transmitter part), 20 MHz (microcomputer operating),
                                              21.948717 MHz (RF receiving circuit part)

Radio Specification
[Transmitter part]
 Radio Type                             :     Transceiver
 Frequency of Operation                 :     134.2 kHz
 Modulation                             :     ASK
 Power Supply (inner)                   :     DC 8 V (LF transmitter part), DC 5 V (other parts)
 Antenna type                           :     Coil Antenna
 Operating Temperature                  :     -20 deg. C to +80 deg. C

[Receiver part]*
 Radio Type                             :     Receiver
 Frequency of Operation                 :     433.92 MHz

*1) The test of receiver part was performed separately from this test report, and the conformability is confirmed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                             Test report No.         : 11766072H-A-R1
                                                                                             Page                    : 5 of 17
                                                                                             Issued date             : August 22, 2017
                                                                                             FCC ID                  : T8VCL6


 SECTION 3: Test specification, procedures & results

 3.1      Test Specification

 Test Specification                      :    FCC Part 15 Subpart C
                                              FCC Part 15 final revised on June 14, 2017 and effective July 14, 2017

 Title                                   :    FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                              Section 15.207 Conducted Emission
                                              Section 15.209 Radiated emission limits, general requirements

 * The revision on June 14, 2017, does not affect the test specification applied to the EUT.

 * Also the EUT complies with FCC Part 15 Subpart B.


 3.2        Procedures and results

No.              Item                Test Procedure           Specification        Remarks     Deviation         Worst margin            Results
                                 <FCC>
                                                            <FCC>
                                 ANSI C63.10:2013
                                 6 Standard test methods    Section 15.207
 1     Conducted Emission                                                      -             N/A *1)           N/A                  N/A
                                 <IC>                       <IC>
                                 RSS-Gen 8.8                RSS-Gen 8.8

                                  <FCC>                     <FCC>                                           10.7 dB
                                  ANSI C63.10:2013          Section 15.209                                  0.139 MHz
       Electric Field Strength of 6 Standard test methods
 2                                                          <IC>                 Radiated     N/A           0 deg.                 Complied
       Fundamental Emission       <IC>                      RSS-210 4.4                                     PK with Duty
                                  RSS-Gen 6.4, 6.12         RSS-Gen 8.9                                     Factor
                                  <FCC>                     <FCC>
                                  ANSI C63.10:2013          Section 15.209                                  0.8 dB
     Electric Field Strength of 6 Standard test methods
 3                                                          <IC>                 Radiated     N/A           114.030 MHz            Complied
     Spurious Emission            <IC>                      RSS-210 4.4                                     Vertical, QP
                                  RSS-Gen 6.4, 6.13         RSS-Gen 8.9
                                  <FCC>                     <FCC>
                                  ANSI C63.10:2013
 4 -26dB Bandwidth                6 Standard test methods Reference data         Radiated     N/A           N/A                    N/A
                                  <IC>                      <IC>
                                  -                         -
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line.

 FCC Part 15.31 (e)
 The EUT provides stable voltage (DC 8 V) constantly to the wireless transmitter regardless of input voltage.
 Instead of a new battery, DC power supply was used for the test.
 That does not affect the test result, therefore the EUT complies with the requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone        : +81 596 24 8999
 Facsimile        : +81 596 24 8124


                                                                                              Test report No.   : 11766072H-A-R1
                                                                                              Page              : 6 of 17
                                                                                              Issued date       : August 22, 2017
                                                                                              FCC ID            : T8VCL6



3.3       Addition to standard

No. Item                     Test Procedure Specification          Remarks Deviation Worst margin                            Results
1   99 % Occupied            RSS-Gen 6.6         -                 Radiated N/A          N/A                                 N/A
    Band Width
 Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4       Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.


                                     Radiated emission
        Test distance                      (+/-)

                                       9 kHz - 30 MHz
  3m                                       3.8 dB
  10 m                                     3.7 dB
*Measurement distance

                                                         Radiated emission (Below 1 GHz)
                                              (3 m*)(+/-)                              (10 m*)(+/-)
            Polarity
                                     30 MHz -           200 MHz -                                  200 MHz -
                                                                         30 MHz - 200 MHz
                                     200 MHz             1000 MHz                                   1000 MHz
           Horizontal                 5.0 dB               5.3 dB               5.0 dB                5.0 dB
            Vertical                  4.7 dB               5.9 dB               5.0 dB                5.1 dB

Radiated emission test(3 m)
[Electric Field Strength of Fundamental Emission]
The data listed in this test report has enough margin, more than the site margin.

[Electric Field Strength of Spurious Emission]
The data listed in this report meets the limits unless the uncertainty is taken into consideration.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                        Test report No.     : 11766072H-A-R1
                                                                                        Page                : 7 of 17
                                                                                        Issued date         : August 22, 2017
                                                                                        FCC ID              : T8VCL6



3.5      Test Location

UL Japan, Inc. Ise EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999           Facsimile : +81 596 24 8124
                        IC Registration    Width x Depth x       Size of                          Other
                        Number             Height (m)            reference ground plane (m) /     rooms
                                                                 horizontal conducting plane
 No.1 semi-anechoic     2973C-1            19.2 x 11.2 x 7.7m    7.0 x 6.0m                       No.1 Power
 chamber                                                                                          source room
 No.2 semi-anechoic     2973C-2            7.5 x 5.8 x 5.2m      4.0 x 4.0m                       -
 chamber
 No.3 semi-anechoic     2973C-3            12.0 x 8.5 x 5.9m     6.8 x 5.75m                      No.3
 chamber                                                                                          Preparation
                                                                                                  room
 No.3 shielded room     -                   4.0 x 6.0 x 2.7m      N/A                             -
 No.4 semi-anechoic     2973C-4             12.0 x 8.5 x 5.9m     6.8 x 5.75m                     No.4
 chamber                                                                                          Preparation
                                                                                                  room
 No.4 shielded room     -                   4.0 x 6.0 x 2.7m      N/A                             -
 No.5 semi-anechoic     -                   6.0 x 6.0 x 3.9m      6.0 x 6.0m                      -
 chamber
 No.6 shielded          -                   4.0 x 4.5 x 2.7m      4.0 x 4.5 m                     -
 room
 No.6 measurement       -                   4.75 x 5.4 x 3.0m     4.75 x 4.15 m                   -
 room
 No.7 shielded room     -                   4.7 x 7.5 x 2.7m      4.7 x 7.5m                      -
 No.8 measurement         -                  3.1 x 5.0 x 2.7m        N/A                            -
 room
 No.9 measurement         -                  8.0 x 4.6 x 2.8m        2.4 x 2.4m                     -
 room
 No.11 measurement        -                  6.2 x 4.7 x 3.0m        4.8 x 4.6m                     -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and No.4 semi-anechoic
chambers and No.3 and No.4 shielded rooms.



3.6    Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                    Test report No.   : 11766072H-A-R1
                                                                                    Page              : 8 of 17
                                                                                    Issued date       : August 22, 2017
                                                                                    FCC ID            : T8VCL6


SECTION 4: Operation of E.U.T. during testing

4.1      Operating Modes

Test mode                                                         Remarks
Transmitting mode                                                 134.2 kHz

Justification    :        The system was configured in typical fashion (as a user would normally use it) for testing.


4.2 Configuration and peripherals




                                                              A




                                                                  2

                                                   1                  B




                                               DC 12 V



* Cabling and setup were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
 No. Item                   Model number               Serial number       Manufacturer                    Remark
 A      Steering Lock           CL6                    No.1                ASAHI DENSO CO., LTD.           EUT
 B      LF Antenna              CZ162                  7510                ASAHI DENSO CO., LTD.           EUT

List of cables used
 No.            Name                  Length (m)                           Shield                         Remark
                                                                Cable               Connector
 1      DC Cable                2.0                           Unshielded            Unshielded        -
 2      Signal Cable            0.6                           Unshielded            Unshielded        -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.    : 11766072H-A-R1
                                                                                  Page               : 9 of 17
                                                                                  Issued date        : August 22, 2017
                                                                                  FCC ID             : T8VCL6


SECTION 5: Radiated emission (Fundamental and Spurious Emission)
Test Procedure

EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

  Frequency : From 9 kHz to 30 MHz
    The EUT was rotated a full revolution in order to obtain the maximum value of the electric field intensity.
    The measurements were performed for vertical polarization (antenna angle: 0 deg., 45 deg., 90 deg., and 135 deg.)
    and horizontal polarization.
    *Refer to Figure 1 about Direction of the Loop Antenna.

  Frequency: From 30 MHz to 1 GHz
    The measuring antenna height varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain
    the maximum value of the electric field intensity.
    The measurements were performed for both vertical and horizontal antenna polarization.

The test was made with the detector (RBW / VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
Frequency             Below 30 MHz                           30 MHz to 200 MHz              200 MHz to 1 GHz
Antenna Type          Loop                                   Biconical                      Logperiodic

Frequency             From 9 kHz to         From 90 kHz to        From 150 kHz        From 490 kHz        From 30 MHz
                         90 kHz                110 kHz             to 490 kHz           to 30 MHz           to 1 GHz
                           and
                     From 110 kHz to
                         150 kHz
Instrument used                                                   Test Receiver
Detector                  PK / AV                  QP               PK / AV                QP                  QP
IF Bandwidth               200 Hz                200 Hz               9 kHz               9 kHz              120 kHz
Test Distance             3 m *1)                3 m *1)             3 m *1)             3 m *2)               3m
*1) Distance Factor: 40 x log (3 m / 300 m) = -80 dB
*2) Distance Factor: 40 x log (3 m / 30 m) = -40 dB

Although these tests were performed other than open field test site, adequate comparison measurements were confirmed
against 30 m open field test site. Therefore sufficient tests were made to demonstrate that the alternative site produces
results that correlate with the ones of tests made in an open field based on KDB 414788.

These tests were performed in semi anechoic chamber. Therefore the measured level of emissions may be higher than if
measurements were made without a ground plane.
However test results were confirmed to pass against standard limit.

- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of
maximum noise, and the test was made at the position that has the maximum noise.
Also, it was confirmed that there were no differences in the noise levels and bandwidth of EUT regardless of with or without
transponder.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range                      : 9 kHz - 1 GHz
Test data                              : APPENDIX 1
Test result                            : Pass

Date: June 27, 2017                              Test engineer: Yuta Moriya
UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                        Test report No.   : 11766072H-A-R1
                                                                        Page              : 10 of 17
                                                                        Issued date       : August 22, 2017
                                                                        FCC ID            : T8VCL6



Figure 1: Direction of the Loop Antenna


  Side View (Vertical)


        EUT




  Top View (Horizontal)




        EUT




                                           Antenna was not rotated.


 Top View (Vertical)


                                            135deg

       EUT                                 90deg

                                             45deg
                                                      0deg


                                         Front side: 0 deg.
                                         Forward direction: clockwise




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                               Test report No.    : 11766072H-A-R1
                                                                                               Page               : 11 of 17
                                                                                               Issued date        : August 22, 2017
                                                                                               FCC ID             : T8VCL6


SECTION 6: -26dB Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test                      Span              RBW            VBW           Sweep              Detector      Trace        Instrument used
-26 dB Bandwidth          50 kHz            510 Hz         1.5 kHz       Auto               Peak          Max Hold     Spectrum Analyzer

Test data                                 : APPENDIX 1
Test result                               : Pass



SECTION 7: 99% Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test               Span                     RBW            VBW           Sweep              Detector      Trace        Instrument used
99 % Occupied     Enough width to display 1 to 5 %        Three times Auto                   Peak *1)     Max Hold     Spectrum Analyzer
Bandwidth         emission skirts           of OBW        of RBW                                          *1)
*1) The measurement was performed with Peak detector, Max Hold since the duty cycle was not 100 %.
Peak hold was applied as Worst-case measurement.


Test data                                 : APPENDIX 1
Test result                               : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                          Test report No.           : 11766072H-A-R1
                                                                                                          Page                      : 12 of 17
                                                                                                          Issued date               : August 22, 2017
                                                                                                          FCC ID                    : T8VCL6


APPENDIX 1: Test data

                 Radiated Emission below 30 MHz (Fundamental and Spurious Emission)

                            Test place                         Ise EMC Lab. No.2 Semi Anechoic Chamber
                            Order No.                          11766072H
                            Date                               June/27/2017
                            Temperature/ Humidity              23 deg. C / 42 % RH
                            Engineer                           Yuta Moriya
                            Mode                               Tx 134.2 kHz

PK or QP
  Ant Deg [deg] Frequency Detector Reading          Ant        Loss      Gain       Duty         Result    Limit            Margin                Remark
         or          消すな                           Factor                          Factor
Polarity [Hori/Vert] [MHz]               [dBuV] [dB/m]         [dB]      [dB]       [dB]       [dBuV/m] [dBuV/m]             [dB]
                 0    0.13900 PK           100.4      19.7      -73.9      32.2           -           14.0   44.7                    30.7 Fundamental
                 0    0.15116 PK            80.1      19.6      -73.9      32.2           -           -6.4   44.0                    50.4
                 0    0.27800 PK            61.6      19.6      -73.9      32.2           -          -24.9   38.7                    63.6
                 0    0.41700 PK            55.1      19.6      -73.9      32.1           -          -31.3   35.2                    66.5
                 0    0.55600 QP            36.8      19.5      -33.8      32.1           -           -9.6   32.7                    42.3
                 0    0.69500 QP            41.0      19.5      -33.8      32.2           -           -5.5   30.7                    36.2
                 0    0.83400 QP            32.2      19.5      -33.8      32.2           -          -14.3   29.2                    43.5
                 0    0.97300 QP            33.3      19.5      -33.8      32.2           -          -13.2   27.8                    41.0
                 0    1.11200 QP            31.1      19.5      -33.8      32.2           -          -15.4   26.6                    42.0
                 0    1.25100 QP            30.9      19.5      -33.7      32.2           -          -15.5   25.6                    41.1
                 0    1.39000 QP            30.8      19.5      -33.7      32.2           -          -15.6   24.7                    40.3
Result = Reading + Ant Factor + Loss (Cable + Attenuator + Filter + D.Factor) - Gain(Amprifier)

PK with Duty factor
 Ant Deg [deg] Frequency Detector Reading              Ant       Loss      Gain        Duty         Result     Limit        Margin                Remark
    Ant Deg         消すな                              Factor                           Factor
    Ant Deg          [MHz]               [dBuV] [dB/m]           [dB]      [dB]        [dB]       [dBuV/m] [dBuV/m]          [dB]
               0        0.139 PK           100.4        19.7      -73.9      32.2          0.0            14.0   24.7                10.7
               0        0.151 PK             80.1       19.6      -73.9      32.2          0.0            -6.4   24.0                30.4
               0        0.278 PK             61.6       19.6      -73.9      32.2          0.0           -24.9   18.7                43.6
               0        0.417 PK             55.1       19.6      -73.9      32.1          0.0           -31.3   15.2                46.5
Result = Reading + Ant Factor + Loss (Cable + Attenuator + Filter + D.Factor) - Gain(Amprifier) + Duty factor *
                  * Since the peak emission result satisfied the average limit, duty factor was omitted.




      Result of the fundamental emission at 3m without Distance factor
PK or QP
 Ant Deg [deg]     Frequency Detector Reading       Ant       Loss     Gain       Duty         Result        Limit          Margin                 Remark
                    消すな                           Factor                         Factor
                     [MHz]               [dBuV] [dB/m]        [dB]     [dB]       [dB]       [dBuV/m] [dBuV/m]               [dB]
               0      0.13900 PK           100.4     19.7         6.1    32.2           -          94.0      -                              - Fundamental
Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)
     消すな


      * All spurious emissions lower than this result.


            *The test result is rounded off to one or two decimal places, so some differences might be observed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                                         Test report No.               : 11766072H-A-R1
                                                                                                                         Page                          : 13 of 17
                                                                                                                         Issued date                   : August 22, 2017
                                                                                                                         FCC ID                        : T8VCL6




                             Radiated Emission above 30 MHz (Spurious Emission)



                                          DATA OF RADIATED EMISSION TEST
                                                                                        UL Japan, Inc. Ise EMC Lab. No.2 Semi Anechoic Chamber
                                                                                                                           Date
                                                                                                                           Date :: 2017/06/27
                                                                                                                                   2017/06/28
                 Company              : 朝日電装株式会社                                          Report No.            :    11766072H
                 Kind of EUT          :                                                   Power                 :    DC 12V
                 Model No.            : HF UNIT                                           Temp./Humi.           :    23deg. C / 42% RH
                 Serial No.           :                                                   Engineer              :    Yuta Moriya
                 Mode / Remarks : Tx 134.2KHz Worst-axis(Hori:Ant_X/ECU_X Vert:Ant_X/ECU_X)

                 LIMIT : FCC15.209 3m, below 1GHz:QP, above 1GHz:PK
                         All other spurious emissions were less than 20dB for the limit.                                                        Horizontal
                                                                                                                                                Vertical
                                                                                                                                                Horizontal
                     [dBuV/m]           << QP DATA >>                                                                                           Vertical
               100

                90

                80

                70

                60

                50

                40

                30

                20

                10

                 0
                  30M                 50M           70M          100M                      200M              300M                  500M       700M        1G
                                                                                                                                              Frequency[Hz]



                                                      Antenna     Loss&
                      Frequency     Reading                                  Level       Angle    Height                Limit      Margin
                                              DET      Factor      Gain                                     Polar.                           Comment
                        [MHz]       [dBuV]             [dB/m]      [dB]     [dBuV/m ]    [Deg]     [cm]                [dBuV/m]     [dB]
                           56.938      26.0   QP           8.5      -21.1        13.4       210       300   Hori.           40.0      26.6
                           56.938      41.2   QP           8.5      -21.1        28.6         0       100   Vert.           40.0      11.4
                           58.333      25.7   QP           8.0      -21.0        12.7       212       286   Hori.           40.0      27.3
                           58.333      41.6   QP           8.0      -21.0        28.6         3       100   Vert.           40.0      11.4
                           79.674      43.5   QP           6.6      -20.7        29.4       210       100   Vert.           40.0      10.6
                           79.674      28.9   QP           6.6      -20.7        14.8       349       230   Hori.           40.0      25.2
                          112.344      42.2   QP          11.8      -20.4        33.6       197       283   Hori.           43.5       9.9
                          112.344      51.1   QP          11.8      -20.4        42.5       284       100   Vert.           43.5       1.0
                          114.030      41.7   QP          12.1      -20.4        33.4       203       284   Hori.           43.5      10.1
                          114.030      51.0   QP          12.1      -20.4        42.7       285       100   Vert.           43.5       0.8
                          238.440      31.4   QP          11.6      -18.8        24.2       147       146   Hori.           46.0      21.8
                          238.440      29.8   QP          11.6      -18.8        22.6       114       100   Vert.           46.0      23.4




                 CHART: WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-200MHz:BICONICAL, 200MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN
                 CALCULATION : RESULT = READING + ANT FACTOR + LOSS & GAIN(CABLE + ATTEN - GAIN(AMP))




         *The test result is rounded off to one or two decimal places, so some differences might be observed.


UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                              Test report No.   : 11766072H-A-R1
                                                                              Page              : 14 of 17
                                                                              Issued date       : August 22, 2017
                                                                              FCC ID            : T8VCL6



                           -26 dB Bandwidth and 99 % Occupied Bandwidth

                     Test place                Ise EMC Lab. No.2 Semi Anechoic Chamber
                     Order No.                 11766072H
                     Date                      June/27/2017
                     Temperature/ Humidity     23 deg. C / 42 % RH
                     Engineer                  Yuta Moriya
                     Mode                      Tx 134.2 kHz


                            -26 dB Bandwidth                     99 % Occupied Bandwidth
                                  [kHz]                                   [kHz]
                                  18.303                                  16.8160




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                     Test report No.      : 11766072H-A-R1
                                                                                     Page                 : 15 of 17
                                                                                     Issued date          : August 22, 2017
                                                                                     FCC ID               : T8VCL6


APPENDIX 2: Test instruments
EMI test equipment
  Control No.         Instrument         Manufacturer          Model No       Serial No       Test Item   Calibration Date *
                                                                                                           Interval(month)
   MAEC-02      Semi Anechoic         TDK               Semi Anechoic     DA-06902          RE            2016/08/02 * 12
                Chamber(NSA)                            Chamber 3m
   MOS-22       Thermo-Hygrometer     Custom            CTH-201           0003              RE            2016/12/13 * 12
   MJM-14       Measure               KOMELON           KMC-36            -                 RE            -
 COTS-MEMI      EMI measurement       TSJ               TEPTO-DV          -                 RE            -
                program
   MSA-16       Spectrum Analyzer     Agilent           E4440A            MY46186390        RE            2017/02/21 * 12
   MTR-03       Test Receiver         Rohde & Schwarz   ESCI              100300            RE            2016/10/21 * 12
   MLPA-01      Loop Antenna          Rohde & Schwarz   HFH2-Z2           100017            RE            2016/10/14 * 12
   MCC-13       Coaxial Cable         Fujikura          3D-2W(12m)/       -                 RE            2017/02/24 * 12
                                                        5D-2W(5m)/
                                                        5D-2W(0.8m)/
                                                        5D-2W(1m)
   MCC-143      Coaxial Cable         UL Japan          -                 -                 RE            2017/06/12 * 12
   MPA-14       Pre Amplifier         SONOMA            310               260833            RE            2017/03/27 * 12
                                      INSTRUMENT
   MAT-07       Attenuator(6dB)       Weinschel Corp    2                 BK7970            RE            2016/11/28 * 12
   MMM-01       Digital Tester        Fluke             FLUKE 26-3        78030611          RE            2016/08/23 * 12
   MBA-08       Biconical Antenna     Schwarzbeck       VHA9103B          08031             RE            2016/09/29 * 12
   MLA-21       Logperiodic          Schwarzbeck        VUSLP9111B        911B-190          RE            2017/01/05 * 12
                Antenna(200-1000MHz)
   MCC-12       Coaxial Cable        Fujikura/Agilent   -                 -                 RE            2017/02/24 * 12
   MPA-09       Pre Amplifier         Agilent           8447D             2944A10845        RE            2016/09/13 * 12



The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test Item:
        RE: Spurious emission




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124



Document Created: 2017-08-23 10:06:22
Document Modified: 2017-08-23 10:06:22

© 2024 FCC.report