power base

FCC ID: T8D-I7770BAS

Test Report

Download: PDF
FCCID_707447

PEAK OUTPUT POWER OF THE BASE

Standard: FCC Part 15

Test procedure: paragraph 15.247

Test equipment:

               TYPE                                BRAND                     EMITECH
                                                                             NUMBER
Spectrum analyzer FSP 40               Rohde & Schwarz                         4088
Antenna RGA60                          Electrometrics                          1204
Open site                              EMITECH                                 1274
Radio frequency generator SME06        Rohde & Schwarz                         1669
High pass filter HPM11630              Micro-tronics                           1673
Low-noise amplifier 1 to 18 GHz        ALC                                     2648
Variac R213                            Dereix                                  1419
Power meter 8541B                      Gigatronics                             3479
Power sensor 80401A                    Gigatronics                             3182

Test set up:

The system is tested in an open area test site (OATS).
The test unit is placed on a rotating table, 0.8 m from a ground plane. Zero degree azimuth
corresponds to the front of the equipment under test.
We use for this measure outdoor test site,. The measuring distance between the equipment and
the test antenna is 3 m. The antenna have been oriented in the two polarizations, we have
recorded only highest level.

Measurement of the electro-magnetic field is realized, with a resolution bandwidth and video
bandwidth adjusted at 1 MHz with a peak detector.

Distance of antenna: 3 meters

Antenna height: 1 to 4 meters

Antenna polarization: vertical and horizontal

Equipment under test operating condition:

The equipment is blocked in continuous transmission mode, modulated by internal data
signal.


Results:

Ambient temperature (°C):      19
Relative humidity (%):         36

Polarization of test antenna: horizontal (height: 239 cm)
Position of equipment:        use position (azimuth: 249 degrees)



Sample n° 1     Channel 1 (Low channel)

                                         Level     Cable loss   Antenna Electro-magnetic       P*
                                         dBµV         dB         factor       field           (W)
                                                                   dB      (dBµV/m):
  Normal test   Nominal power source
                                         74.25        4.41          27.77    106.43        7.99 x 10-3
  conditions    (V): 115


Sample n° 1     Channel 40 (middle channel)

                                         Level     Cable loss   Antenna Electro-magnetic        P*
                                         dBµV         dB         factor       field            (W)
                                                                   dB      (dBµV/m):
  Normal test   Nominal power source
                                         75.26        4.41          27.77    107.44        10.08 x 10-3
  conditions    (V): 115


Sample n° 1     Channel 79 (high channel)

                                         Level     Cable loss   Antenna Electro-magnetic        P*
                                         dBµV         dB         factor       field            (W)
                                                                   dB      (dBµV/m):
  Normal test Nominal power source
                                          75.49       4.41          27.77    107.67        10.63 x 10-3
   conditions     (V): 115
* P = (E x d)² / 30.Gp, with d=3 and Gp = 1.65

Test conclusion:

RESPECTED STANDARD



Document Created: 2006-09-21 12:35:15
Document Modified: 2006-09-21 12:35:15

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC