Test Report

FCC ID: T8C001

Test Report

Download: PDF
FCCID_724980

                                                                                         FCC—ID: T8C0o01

            EMCC TM                                                                           Page 1 of 19
            DR. RASEK


                       TEST REPORT # EMCC—950432.1AA, 2006—MAY—26


 EQUIPMENT UNDER TEST:
     Name:                                  4—command transmitter AM 315 MHz
      Model:                                TX03—315—4
     Serial No:                             100072
      Equipment Category:                   Transmitter
     Manufacturer:                          SOMMER Antriebs— und Funktechnik GmbH
     Address:                               Hans—Boeckler—Strasse 21—27
                                            73230 Kirchheim / Teck
                                            Germany

     Phone:                                 ++49—7021—8001—0
     Fax:                                   ++49—7021—8001—403


 RELEVANT STANDARD:                         47 CFR Part 15C — Intentional Radiators


 MEASUREMENT PROCEDURE USED:

     [X anist C63.4—2003             [] FCC/OoET MP—4 (1987)             [_] Other


 TEST REPORT PREPARED BY:
     Reinhard Sauerschell
     EMCC DR. RASEK
     Moggast, Boelwiese 8
     91320 Ebermannstadt
     Germany
     Phone: +49 9194 9016
     Fax: +49 9194 8125
     E—mail: r.sauerschell@emcc.de


 TEST PERSONNEL:                                      HEAD OF LABORATORY:




        ;              V(                                        4.   feal‘>—
      Reinhard Sauerschell                                  Winfried Hoffmann




EMCC DR. RASEK                              EMC AND RADIO                       Telephone:       +49—9194—9016
Moggast, Boelwiese 8                      TEST LABORATORIES                     Telefax:         +49—9194—8125
91320 Ebermannstadt                                Akkreditierungs              Mail:        emc.cons@emcc.de
Germany                                                  (m—eq                  Web:         http://www.emcc.de

FCC Registration # 90566                      DAT—P—204/95
Report_AA.doc


                                                                                                                                                                   FCC-ID: T8C001
                                                                                                                                   Test Report #EMCC-950432.1AA
        EMCC ™                                                                                                                                        Page 2 of 19
       DR. RAŠEK
                                                                                                                                         Issue Date: 2006-MAY-26
                          TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                            TO 47 CFR PART 15C - INTENTIONAL RADIATORS



CONTENTS                                                                                                                                                                                        Page


1    GENERAL INFORMATION ...................................................................................................................................................................3
     1.1   Purpose..................................................................................................................................................................................3
     1.2   Limits and Reservations ......................................................................................................................................................3
     1.3   Test Location.........................................................................................................................................................................3
     1.4   Manufacturer .........................................................................................................................................................................3
     1.5   Dates ......................................................................................................................................................................................3
2    Product Description.............................................................................................................................................................................4
     2.1     Equipment Under Test (EUT)...............................................................................................................................................4
     2.2     EUT Peripherals ....................................................................................................................................................................4
     2.3     Mode of Operation During Testing .....................................................................................................................................4
     2.4     Modifications Required for Compliance ............................................................................................................................4
3    Test Results Summary ........................................................................................................................................................................5
4    Antenna Requirement..........................................................................................................................................................................6
     4.1     Regulation .............................................................................................................................................................................6
     4.2     Result .....................................................................................................................................................................................6
5    Radiated Emissions TEST...................................................................................................................................................................7
     5.1      Regulation .............................................................................................................................................................................7
     5.2      Test Equipment .....................................................................................................................................................................8
     5.3      Test Procedures....................................................................................................................................................................8
     5.4      Calculation of Field Strength Limits ...................................................................................................................................9
     5.5      Calculation of Average Correction Factor .........................................................................................................................9
     5.6      Field Strength Calculation ...................................................................................................................................................9
     5.7      Test Results.........................................................................................................................................................................11
         5.7.1     Magnetic Field (f = 1.7 MHz to 30 MHz) .....................................................................................................................11
         5.7.2     Electric Field (f = 30 MHz to 3.2 GHz)........................................................................................................................12
6    Conducted Emissions Tests.............................................................................................................................................................14
     6.1    Regulation ...........................................................................................................................................................................14
     6.2    Test Equipment ...................................................................................................................................................................14
     6.3    Test Procedures..................................................................................................................................................................14
     6.4    Test Results.........................................................................................................................................................................14
7    Periodic Operation Characteristics..................................................................................................................................................15
     7.1       Periodic Operation..............................................................................................................................................................15
          7.1.1    Regulation....................................................................................................................................................................15
          7.1.2    Result ...........................................................................................................................................................................15
     7.2       Manually Operated Transmitter Deactivation ..................................................................................................................15
          7.2.1    Regulation....................................................................................................................................................................15
          7.2.2    Result ...........................................................................................................................................................................15
     7.3       Automatically Operated Transmitter Deactivation ..........................................................................................................16
          7.3.1    Regulation....................................................................................................................................................................16
          7.3.2    Result ...........................................................................................................................................................................16
     7.4       Prohibition of Periodic Transmission...............................................................................................................................16
          7.4.1    Regulation....................................................................................................................................................................16
          7.4.2    Result ...........................................................................................................................................................................16
     7.5       Continuous Transmission During an Alarm Condition ..................................................................................................16
          7.5.1    Regulation....................................................................................................................................................................16
          7.5.2    Result ...........................................................................................................................................................................16
8    Bandwidth...........................................................................................................................................................................................17
     8.1    Regulation ...........................................................................................................................................................................17
     8.2    Calculation of 20 dB Bandwidth Limit..............................................................................................................................17
     8.3    Test Equipment ...................................................................................................................................................................17
     8.4    Test Procedure....................................................................................................................................................................17
     8.5    Test Result...........................................................................................................................................................................18
9    Miscellaneous Comments and Notes ..............................................................................................................................................19
10          List of ANNEXES ........................................................................................................................................................................19




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 3 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




1 GENERAL INFORMATION

1.1 Purpose
The purpose of this report is to show compliance to the FCC regulations for unlicensed devices
operating under section 15.231 of the Code of Federal Regulations title 47.


1.2 Limits and Reservations
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report. This test report shall not be reproduced except in full without the written permission of EMCC DR.
RAŠEK.


1.3 Test Location
Company Name:                          EMCC DR. RAŠEK
Street:                                Moggast 72-74
City:                                  91320 Ebermannstadt
Country:                               Germany
Laboratory:                            Test Laboratory of EMCC DR. RAŠEK
                                       FCC Registration Number: 90566
                                       This site has been fully described in a report submitted to the FCC,
                                       and accepted in the letter dated December 15, 2005 Registration
                                       Number 90566.
Phone:                                 +49-9194-9016
Fax:                                   +49-9194-8125
E-Mail:                                emc.cons@emcc.de
Web:                                   www.emcc.de


1.4 Manufacturer
Company Name:                          SOMMER Antriebs- und Funktechnik GmbH
Street:                                Hans-Boeckler-Strasse 21-27
City:                                  73230 Kirchheim / Teck
Country:                               Germany

Name for contact purposes:             Mr Dominik Schwarz
Phone:                                 ++49-7021-8001-411
Fax:                                   ++49-7021-8001-403
E-mail:                                D.Schwarz@sommer-torantriebe.de


1.5 Dates
Date of receipt of EUT:                CW 19/2006
Test date:                             CW 19/2006




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 4 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




2 PRODUCT DESCRIPTION

2.1 Equipment Under Test (EUT)

Device:                  Remote Control (RF) Transmitter
Name:                    4-command transmitter AM 315 MHz
Model:                   TX03-315-4
Serial Number:           100072
Application:             wireless telecommand
Power:                   3 V battery, CR2032 type
Transmit Frequency:      315 MHz, one RF channel
Modulation:              ASK
Emission designator:     A1D
Antenna:                 internal, integral
Interface ports:         none
Variants:                none
Lowest frequency in EUT: 9.84375 MHz

FCC-ID:                      T8C001


2.2 EUT Peripherals
The EUT was tested as stand-alone device.


2.3 Mode of Operation During Testing
The transmitter was tested in a typical fashion. During preliminary and final emission tests all transmitter
channels (buttons) were activated to investigate a worst case emission mode. Also the movable clip-
housing was set into different positions during TX-mode. The emission levels were found to be within 1
dB for all arrangements. Worst case values are documented.

2.4 Modifications Required for Compliance
None.




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                               Test Report #EMCC-950432.1AA
     EMCC ™                                                                                       Page 5 of 19
    DR. RAŠEK
                                                                                     Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




3 TEST RESULTS SUMMARY

Summary of Test Results
Transmitter, type TX03-315-4

Requirement                                    CFR Section                 Report Section         Test Result
Antenna Requirement                            15.203                      4                      Pass

Radiated Spurious Emissions                    15.209, 15.205(b)           5                      Pass

Conducted Emissions                            15.207                      6                      *

Periodic Operation Characteristics             15.231(a)                   7                      Pass

Field Strength Limits (Fundamental)            15.231(b)                   5                      Pass

20 dB Bandwidth                                15.231(c)                   8                      Pass

* Not required, the EUT is battery powered.

The client has made the determination that EUT Condition, Characterization, and Mode of Operation are
representative of production units, and meet the requirements of the specifications referenced herein.

Consistent with Industry practice, measurement and test equipment not directly involved in obtaining
measurement results but having an impact on measurements (such as cable loss, antenna factors, etc.)
are factored into the "Correction Factor" documented in certain test results. Instrumentation employed
for testing meets tolerances consistent with known Industry Standards and Regulations.

The measurements contained in this report were made in accordance with the procedure ANSI C63.4 -
2003 and all applicable Public Notices received prior to the date of testing. All emissions from the device
were found to be within the limits outlined in this report.
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report.

Test Personnel: Reinhard Sauerschell
Issuance Date: 2006-05-26




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 6 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




4 ANTENNA REQUIREMENT
Test Requirement: FCC CFR47, Part 15C

4.1 Regulation
15.203 An intentional radiator shall be designed to ensure that no antenna other than that furnished by
the responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
with the provisions of Part 15C. The manufacturer may design the unit so that the user can replace a
broken antenna, but the use of a standard antenna jack or electrical connector is prohibited. This
requirement does not apply to carrier current devices or to devices operated under the provisions of
Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
intentional radiators that must be professionally installed, such as perimeter protection systems and
some field disturbance sensors, or to other intentional radiators which, in accordance with Section
15.31(d), must be measured at the installation site. However, the installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.



4.2 Result
Device: Remote Control (RF) Transmitter

Transmitter Type: TX03-315-4

Antenna is a trace on the PCB.
The EUT meets the requirements of this section.




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 7 of 19
     DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




5 RADIATED EMISSIONS TEST
Test Requirement: FCC CFR47, Part 15C
Test Procedure: ANSI C63.4:2003

5.1 Regulation
15.231(b) In addition to the provisions of Section 15.205, the field strength of emissions from intentional
radiators operated under this Section shall not exceed the following:
Fundamental Frequency              Field Strength of Fundamental          Field Strength of Spurious Emissions
(MHz)                              (microvolts/meter)                     (microvolts/meter)
40.66 - 40.70                      2,250                                  225
70 - 130                           1,250                                  125
130 - 174                          1,250 to 3,750 **                      125 to 375 **
174 - 260                          3,750                                  375
260 - 470                          3,750 to 12,500 **                     375 to 1,250 **
Above 470                          12,500                                 1,250
** Linear interpolations
[Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental field
strengths are as follows: for the band 130-174 MHz, µV/m at 3 meters = 56.81818(F) - 6136.3636; for
the band 260-470 MHz, µV/m at 3 meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted
emission level is 20 dB below the maximum permitted fundamental level.]
(1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the
band edges.
(2) Intentional radiators operating under the provisions of this Section shall demonstrate compliance with
the limits on the field strength of emissions, as shown in the above table, based on the average value of
the measured emissions. As an alternative, compliance with the limits in the above table may be based
on the use of measurement instrumentation with a CISPR quasi-peak detector. The specific method of
measurement employed shall be specified in the application for equipment authorization. If average
emission measurements are employed, the provisions in Section 15.35 for averaging pulsed emissions
and for limiting peak emissions apply. Further, compliance with the provisions of Section 15.205 shall be
demonstrated using the measurement instrumentation specified in that section.
(3) The limits on the field strength of the spurious emissions in the above table are based on the
fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average
(or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in Section
15.209, whichever limit permits a higher field strength.
Section 15.33 Frequency range of radiated measurements:
(a) Unless otherwise noted in the specific rule section under which the equipment operates for an
intentional radiator the spectrum shall be investigated from the lowest radio frequency signal generated
in the device, without going below 9 kHz, up to at least the frequency shown in this paragraph:
(1) If the intentional radiator operates below 10 GHz: to the tenth harmonic of the highest fundamental
frequency or to 40 GHz, whichever is lower.



REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 8 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




5.2 Test Equipment

Type                      Manufacturer/ Model        Serial No.              Last Calibration      Next Calibration
                          No.
Receiver                  Rohde & Schwarz            832808/004              Oct 2005              April 2007
(1.7 MHz - 1 GHz)         ESS
Loop Antenna              R&S, HFH 2-Z2              892665/004              July 2004             July 2006
Antenna                   EMCO 3143                  9604-1269               Oct 2005              Oct 2007
(30 MHz - 1 GHz)
Receiver                  Rohde & Schwarz            100126                  Nov 2005              Nov 2007
(1 GHz – 3.2 GHz)         ESIB 40
Antenna                   Schwarzbeck                137                     March 2006            March 2008
(1 GHz – 3.2 GHz)         BBHA 9120 D



5.3 Test Procedures
For tabletop equipment, the EUT is placed on a 1 meter by 1.5 meters wide and 0.8 meter high
nonconductive table that sits on a flush mounted metal turntable. Floor standing equipment is placed
directly on the flush mounted metal turntable [Remark: Not applicable]. The EUT is connected to its
associated peripherals with any excess I/O cabling bundled to approximately 1 meter [Remark: Not
applicable].
Preview tests are performed to determine the "worst case" mode of operation. With the EUT operating
in "worst case" mode, emissions from the unit are maximized by adjusting the polarization and height of
the receive antenna and rotating the EUT on the turntable. Manipulating the system cables also
maximizes EUT emissions [Remark: Not applicable]. All tests performed with the EUT placed in two
polarizations on the nonconductive table: horizontal and vertical.
Where the PEAK results kept below the AV limits, no further AV tests were performed.
New batteries were installed at the beginning of the tests.


Radiated Emissions Test Characteristics
Frequency range                                             1.7 MHz – 3,200 MHz
Test distance                                               3 m*
Test instrumentation resolution bandwidth                   10 kHz (1.7 MHz - 30 MHz)
                                                            120 kHz (30 MHz - 1,000 MHz)
                                                            1 MHz (1,000 MHz – 3,200 MHz)
Receive antenna scan height                                 1 m (H-field, f < 30 MHz)
                                                            1 m - 4 m (E-field, f > 30 MHz)
Receive antenna polarization                                Horizontal (H-field, f < 30 MHz)
                                                            Vertical/Horizontal (E-field, f > 30 MHz)




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                      Page 9 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS


* According to Section 15.31 (f)(1): At frequencies at or above 30 MHz, measurements may be
performed at a distance other than what is specified provided: measurements are not made in the near
field except where it can be shown that near field measurements are appropriate due to the
characteristics of the device; and it can be demonstrated that the signal levels needed to be measured at
the distance employed can be detected by the measurement equipment. (...) When performing
measurements at a distance other than that specified, the results shall be extrapolated to the specified
distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for field strength
measurements; inverse-linear-distance-squared for power density measurements).
According to Section 15.31 (f)(2) At frequencies below 30 MHz, measurements may be performed at a
distance closer than that specified in the regulations; however, an attempt should be made to avoid
making measurements in the near field. Pending the development of an appropriate measurement
procedure for measurements performed below 30 MHz, when performing measurements at a closer
distance than specified, the results shall be extrapolated to the specified distance by either making
measurements at a minimum of two distances on at least one radial to determine the proper
extrapolation factor or by using the square of an inverse linear distance extrapolation factor (40
dB/decade).



5.4 Calculation of Field Strength Limits
Fundamental field strength limits for the band 260 – 470 MHz:
µV/m at 3 meters = 41.6667(F[MHz]) – 7083.3333 = 41.6667* 315 – 7083.3333 = 6,041.7
6,041.7 µV/m corresponds with 75.6 dBµV/m.
The maximum permitted unwanted emission level is 20 dB below the maximum permitted fundamental
level, i.e. 55.6 dBµV/m.

5.5 Calculation of Average Correction Factor
The average correction factor is computed by analyzing the "worst case" on time in any 100 mSec time
period and using the formula:
Correction Factor (dB) = 20∗log (worst case on time/100 mSec)
Procedure during test:
Following emission measurements below 1 GHz were performed using the test receiver’s average and
peak detectors; i.e. the average and peak values measured directly without the necessity of additional
correction factor.
Emission measurements above 1 GHz were performed using the spectrum analyzer's peak detector
together with video bandwidth setting of 10 Hz (is equal 100 mSec average detector) and the max. hold
facility; i.e. the average and peak values measured directly without the necessity of additional correction
factor.

5.6 Field Strength Calculation
The field strength is calculated by adding the Antenna Factor and Cable Factor. The basic equation with
a sample calculation is as follows:

FS = RA + AF + CF
where
    FS = Field Strength in dB(µV/m)
    RA = Receiver Amplitude in dB(µV)

REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                    Page 10 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS


    AF = Antenna Factor in dB(1/m)
    CF = Cable Attenuation Factor in dB

Assume a receiver reading of 23.5 dB(µV) is obtained. The Antenna Factor of 7.4 dB(1/m) and a Cable
Factor of 1.1 dB are added, giving a field strength of 32 dB(µV/m). The 32 dB(µV/m) value can be
mathematically converted to its corresponding level in µV/m.

FS = 23.5 dB(µV) + 7.4 dB(1/m) + 1.1 dB = 32 dB(µV/m)

Level in µV/m = Common Antilogarithm (32/20) = 39.8


For test distance other than what is specified, but fulfilling the requirements of Section 15.31 (f)(1) the
field strength is calculated by adding additionally an extrapolation factor of 20 dB/decade (inverse linear-
distance for field strength measurements). The basic equation with a sample calculation is as follows:

FS = RA + AF + CF + DF
where
    FS = Field Strength in dB(µV/m)
    RA = Receiver Amplitude in dB(µV)
    AF = Antenna Factor in dB(1/m)
    CF = Cable Attenuation Factor in dB
    DF = Distance Extrapolation Factor in dB,
      where DF = 20 log (Dtest/Dspec) where Dtest = Test Distance and Dspec = Specified Distance

Assume the tests performed at a reduced Test Distance of 1,5 m instead of the Specified Distance
of 3 m giving a Distance Extrapolation Factor of DF = 20 log(1,5m/3m) = -6 dB.
Assuming a receiver reading of 23.5 dB(µV) is obtained. The Antenna Factor of 7.4 dB(1/m), the Cable
Factor of 1.1 dB and the Distance Factor of -6 dB are added, giving a field strength of 26 dB(µV/m). The
26 dB(µV/m) value can be mathematically converted to its corresponding level in µV/m.

FS = 23.5 dB(µV) + 7.4 dB(1/m) + 1.1 dB - 6 dB = 26 dB(µV/m)

Level in µV/m = Common Antilogarithm (26/20) = 20




REPORT_AA.DOC


                                                                                                                               FCC-ID: T8C001
                                                                                                                  Test Report #EMCC-950432.1AA
     EMCC ™                                                                                                                        Page 11 of 19
    DR. RAŠEK
                                                                                                                        Issue Date: 2006-MAY-26
                       TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                         TO 47 CFR PART 15C - INTENTIONAL RADIATORS




5.7 Test Results


5.7.1 Magnetic Field (f = 1.7 MHz to 30 MHz)
The magnetic field test was performed in a distance of 2 m. Therefore a distance correction factor of 47
dB is applicable (= correction from 30 m to 2 m).
The plot below shows the worst case emissions of the EUT in TX and standby mode. No emissions were
detected. The noise is < 31 dBµV/m (worst case), which means a corrected result of < - 16 dBµV/m at 30
m. The limit to §15.209 (a) is 30 µV/m (= 29.5 dBµV/m) at 30 m.


       EMCC DR.RASEK                                                                           11. May 06 15:40

       MAGNETIC FIELD TEST
       EUT:                      TX03-315-4
       Manuf:                    Sommer
       Op Cond:                  TX mode
       Operator:                 Sauerschell
       Test Spec:                FCC 15.209
       Comment:                  all directions and positions, max hold
                                 d=2m

       Scan Settings (1 Range)
       |--------- Frequencies -----------||----------- Receiver Settings ------------|
         Start      Stop     Step       IF BW Detector M-Time Atten Preamp OpRge
          1.7M       30M       5k         10k      PK      2ms AUTO LN ON          60dB

       Final Measurement: x QP
                  Meas Time:   1s
                  Subranges: 25
                  Acc Margin: 10dB




        dBuV/m
       80




       70




       60




       50




       40




       30




       20




       10




        0
             1.7                                                                          10                         30
                                                                                                                     MHz
                                                                              PAGE 1




Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT meets the H-field requirements of this section (margin >> 40 dB).

Test Personnel: Reinhard Sauerschell
Test Date:      2006-05-11


REPORT_AA.DOC


                                                                                                              FCC-ID: T8C001
                                                                                                 Test Report #EMCC-950432.1AA
         EMCC ™                                                                                                   Page 12 of 19
        DR. RAŠEK
                                                                                                       Issue Date: 2006-MAY-26
                      TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                        TO 47 CFR PART 15C - INTENTIONAL RADIATORS




5.7.2 Electric Field (f = 30 MHz to 3.2 GHz)

Representative plot from pre-test (f < 1 GHz)
                      Marker 4 [T1]           RBW       100 kHz       RF Att      0 dB
       Ref Lvl                20.69 dBÌ V/m   VBW       100 kHz
        70 dB*            106.28115687 MHz    SWT       3001 ms       Unit       dBÌ V/m
  70
                            100 MHz                         4 [T1]              1 ÌGHz
                                                                          20.69 dB  V/m
                                                                                            A
                                                                      106.28115687 MHz
                                                            1 [T1]        78.70 dBÌ V/m
  60
                                                                      315.86009457 MHz
                                                            2 [T1]        40.29 dBÌ V/m
                                                                      633.32848438 MHz
  50
                                                            3 [T1]        33.31 dBÌ V/m
                                                                      945.33363482 MHz IN1
       1VIEW                                                                2          1MA
  40 FCC_3m

                                                                                     3

  30                                                                                       P20

                                                                                           TDF
                                4
  20




  10




   0




 -10
       Start 30 MHz                                                          Stop 1 GHz

Title:     TX03-315-4
Comment A: prescan 3m, TX mode
Date:      11.MAY.2006 09:35:46



Representative plot from pre-test (f > 1 GHz)
                      Marker 1 [T1]           RBW         1 MHz       RF Att      0 dB
       Ref Lvl                52.79 dBÌ V/m   VBW        10 MHz
        70 dB*              2.52304609 GHz    SWT       6.5 ms        Unit       dBÌ V/m
  70
                                                            1 [T1]        52.79 dBÌ V/m
                                                                                            A
                                                                        2.52304609 GHz
  65
                                                            2 [T1]        52.21 dBÌ V/m
                                                                        2.20741483 GHz
  60                                                        3 [T1]        50.27 dBÌ V/m
                                                                        1.89178357 GHz
                                                            4 [T1]        45.92 dBÌ V/m
  55
        D1 54
           5 dB*                                    1                   2.83867735 GHz IN1
       1VIEW                              2                                                1MA
                                3
  50

                                                                  4
  45                                                                                       P20

                                                                                           TDF
  40



  35



  30



  25



  20
       Start 1 GHz                     250 MHz/                           Stop 3.5 GHz

Title:     TX03-315-4
Comment A: d=3m, EUT hor, Ant hor
Date:      11.MAY.2006 13:38:42




REPORT_AA.DOC


                                                                                                             FCC-ID: T8C001
                                                                                    Test Report #EMCC-950432.1AA
     EMCC ™                                                                                          Page 13 of 19
     DR. RAŠEK
                                                                                          Issue Date: 2006-MAY-26
                 TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                   TO 47 CFR PART 15C - INTENTIONAL RADIATORS



Final results, test distance = 3 m = constant

                         FINAL RESULTS: PRODUCT EMISSIONS AVERAGE DATA
No   Emission    Receiver    Receiver   Correction   Result =     Spec         Polarization         Margin     Notes
     Frequency   Mode and    Reading    Factor       Corrected    Limit
                 Bandwidth                           Reading      AV
                             RA         AF+CF        FS
     [MHz]       [kHz]       [dB(µV)]   [dB(1/m)]    [dB(µV/m)]   [dB(µV/m)]   Antenna        EUT   [dB]
1    315.0115    120, AV     49         17.4         66.4         75.6         h              h     9.2
2    630         120, AV     14         23.9         37.9         55.6         v              v     17.7
3    945         120, AV     12         27.6         39.6         55.6         v              v     16
4    1260        1000, PK    20.8       26.2         47           55.6         h              h     8.6
5    1575        1000, PK    21.8       26.2         48           54           h              h     6
6    1890        1000, AV    13.3       26.7         40           55.6         v              v     15.6
7    2205        1000, AV    11         29           40           54           v              v     14
8    2520        1000, AV    10.5       29           39.5         55.6         v              v     16.1
9    2835        1000, AV    9.5        29.5         39           54           v              v     15
10   3150        1000, PK    19.2       29.8         49           55.6         v              v     6.6



                             FINAL RESULTS: PRODUCT EMISSIONS PEAK DATA
No   Emission    Receiver    Receiver   Correction   Result =     Spec         Polarization         Margin     Notes
     Frequency   Mode and    Reading    Factor       Corrected    Limit
                 Bandwidth                           Reading      AV
                             RA         AF+CF        FS
     [MHz]       [kHz]       [dB(µV)]   [dB(1/m)]    [dB(µV/m)]   [dB(µV/m)]   Antenna        EUT   [dB]
1    315.0115    120, PK     72         17.4         89.4         95.6         h              h     6.2
2    630         120, PK     30         23.9         53.9         75.6         v              v     21.7
3    945         120, PK     26         27.6         53.6         75.6         v              v     22
4    1260        1000, PK    20.8       26.2         47           75.6         h              h     28.6
5    1575        1000, PK    21.8       26.2         48           74           h              h     26
6    1890        1000, PK    29.3       26.7         56           75.6         v              v     19.6
7    2205        1000, PK    28         29           57           74           h              h     17
8    2520        1000, PK    26         29           55           75.6         h              h     20.6
9    2835        1000, PK    21.5       29.5         51           74           v              v     23
10   3150        1000, PK    19.2       29.8         49           75.6         v              v     26.6


Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT meets the E-field requirements of this section.

Test Personnel: Reinhard Sauerschell
Test Date:      2006-05-11




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                    Page 14 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




6 CONDUCTED EMISSIONS TESTS
Test Requirement: FCC CFR47, Part 15C
Test Procedure: ANSI C63.4:2003

6.1 Regulation
Section 15.207 (a) For an intentional radiator which is designed to be connected to the public utility (AC)
power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency
or frequencies within the band 450 kHz to 30 MHz shall not exceed 250 microvolts. Compliance with this
provision shall be based on the measurement of the radio frequency voltage between each power line
and ground at the power terminals.

Section 15.207 (d) Measurements to demonstrate compliance with the conducted limits are not required
for devices which only employ battery power for operation and which do not operate from the AC power
lines or contain provisions for operation while connected to the AC power lines. Devices that include, or
make provision for, the use of battery chargers which permit operating while charging, AC adaptors or
battery eliminators or that connect to the AC power lines indirectly, obtaining their power through another
device which is connected to the AC power lines, shall be tested to demonstrate compliance with the
conducted limits.

6.2 Test Equipment
Not applicable.

6.3 Test Procedures
Not applicable.

6.4 Test Results
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT is battery powered only. Therefore - according to Section 15.207 (d) - conducted emissions
measurements to demonstrate compliance with the conducted limits are not required.




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                    Page 15 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




7 PERIODIC OPERATION CHARACTERISTICS
Test Requirement: FCC CFR47, Part 15C

7.1 Periodic Operation

7.1.1 Regulation
15.231(a) The provisions of this Section are restricted to periodic operation within the band 40.66 -
40.70 MHz and above 70 MHz. Except as shown in paragraph (e) of this Section, the intentional radiator
is restricted to the transmission of a control signal such as those used with alarm systems, door openers,
remote switches, etc. Radio control of toys is not permitted. Continuous transmissions, such as voice or
video, and data transmissions are not permitted. The prohibition against data transmissions does not
preclude the use of recognition codes. Those codes are used to identify the sensor that is activated or
to identify the particular component as being part of the system.

7.1.2 Result
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT meets the requirements of this section.



7.2 Manually Operated Transmitter Deactivation

7.2.1 Regulation
15.231(a1) A manually operated transmitter shall employ a switch that will automatically deactivate the
transmitter within not more than 5 seconds of being released.

7.2.2 Result
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

Transmitter ceases immediately after being released. The EUT meets the requirements of this section.




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                    Page 16 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




7.3 Automatically Operated Transmitter Deactivation

7.3.1 Regulation
15.231(a2) A transmitter activated automatically shall cease transmission within 5 seconds after
activation.

7.3.2 Result
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT does not have automatic transmission.



7.4 Prohibition of Periodic Transmission

7.4.1 Regulation
15.231(a3) Periodic transmissions at regular predetermined intervals are not permitted. However,
polling or supervision transmissions to determine system integrity of transmitters used in security or
safety applications are allowed if the periodic rate of transmission does not exceed one transmission of
not more than one second duration per hour for each transmitter.

7.4.2 Result
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

The EUT does not employ periodic transmission.



7.5 Continuous Transmission During an Alarm Condition

7.5.1 Regulation
15.231(a4) Intentional radiators which are employed for radio control purposes during emergencies
involving fire, security, and safety of life, when activated to signal an alarm, may operate during the
pendency of the alarm condition.

7.5.2 Result
Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

This section is not applicable to the EUT.



REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
        EMCC ™                                                                                 Page 17 of 19
        DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




8 BANDWIDTH
Test Requirement: FCC CFR47, Part 15C
Test Procedure: ANSI C63.4:2003 Section 13.1.7

8.1 Regulation
15.231(c) The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20
dB down from the modulated carrier.

8.2 Calculation of 20 dB Bandwidth Limit
The 20 dB bandwidth limit = 0.0025 * 315 MHz = 0.7875 MHz = 787.5 kHz

8.3 Test Equipment
 Type                 Manufacturer/            Serial No.              Last Calibration         Next Calibration
                      Model No.
 Receiver             Rohde & Schwarz          100126                  Nov 2005                 Nov 2007
 (20 Hz – 40 GHz)     ESIB 40
 Test fixture         EMCC                     SRD TF1                 n.a.                     n.a.

8.4 Test Procedure
ANSI C63.4-2003 Section 13.1.7 Occupied Bandwidth Measurements.
(...) The bandwidth is measured at an amplitude level reduced from the reference level by a specified
ratio. The reference level is the level of the highest amplitude signal observed from the transmitter at
either the fundamental frequency or first-order modulation products in all typical modes of operation,
including the unmodulated carrier, even if atypical. Once the reference level is established, the
equipment is conditioned with typical modulating signals to produce worst-case (i.e., the widest)
bandwidth. (...) In order to measure the modulated signal properly, a resolution bandwidth that is small
compared to the bandwidth required by the procuring or regulatory agency shall be used on the
measuring instrument. However, the 6 dB resolution bandwidth of the measuring instrument shall be set
to a value greater than 5% of the bandwidth requirements. When no bandwidth requirements are
specified, the minimum resolution bandwidth of the measuring instrument is given in the following table:

Fundamental frequency              Minimum resolution bandwidth
9 kHz to 30 MHz                    1 kHz
30 to 1000 MHz                     10 kHz
1000 MHz to 40 GHz                 100 kHz

(...)




REPORT_AA.DOC


                                                                                                                 FCC-ID: T8C001
                                                                                                    Test Report #EMCC-950432.1AA
        EMCC ™                                                                                                       Page 18 of 19
        DR. RAŠEK
                                                                                                          Issue Date: 2006-MAY-26
                   TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                     TO 47 CFR PART 15C - INTENTIONAL RADIATORS




8.5 Test Result

Device: Remote Control (RF) Transmitter
Transmitter Type: TX03-315-4

Bandwidth setting of the analyzer: ...............10 kHz [6 dB]
Spectrum analyzer plot:

                        Marker 1 [T1 ndB]            RBW    10 kHz      RF Att       0 dB
       Ref Lvl          ndB         20.00 dB         VBW     1 MHz
       75 dBÌ V         BW    110.22044088 kHz       SWT    25 ms       Unit          dBÌ V
  75
                                                              1 [T1]           63.16 dBÌ V
                                                                                               A
                                                                       315.01102204 MHz
  70
                                                             ndB                 20.00 dB
                                                             BW        110.22044088 kHz
  65                                                          T1 [T1]          42.68 dBÌ V
                                                 1
                                                                       314.98496994 MHz
                                                              T2 [T1]        43.24 dBÌ V
  60
                                                                       315.09519038 MHz IN1
       1VIEW                                                                                  1MA

  55



  50                                                                                          P0



  45                                                   T2
                                            T1


  40



  35



  30



  25
       Center 315 MHz                     100 kHz/                             Span 1 MHz

Title:     TX03-315-4
Comment A: BW test
Date:      11.MAY.2006        15:01:34




The measured 20 dB bandwidth is: ............110.22 kHz


The EUT meets the requirements of this section.
Test Personnel: Reinhard Sauerschell
Test Date:      2006-05-11




REPORT_AA.DOC


                                                                                                 FCC-ID: T8C001
                                                                              Test Report #EMCC-950432.1AA
     EMCC ™                                                                                    Page 19 of 19
    DR. RAŠEK
                                                                                    Issue Date: 2006-MAY-26
                TEST OF S O M M E R AN T R I E B S - U N D F U N K T E C H N I K G M B H MODEL TX03-315-4
                                  TO 47 CFR PART 15C - INTENTIONAL RADIATORS




9 MISCELLANEOUS COMMENTS AND NOTES
None.




10 LIST OF ANNEXES


Following annexes are separated parts to this test report.


Description                                                                                 Pages
Annex 1: Photographs of test setups                                                         7
Annex 2: Photographs of test sample                                                         5




REPORT_AA.DOC



Document Created: 2006-10-31 13:12:22
Document Modified: 2006-10-31 13:12:22