                       COMPLIANCE WORLDWIDE INC.
                          TEST REPORT 197-11A
                         In Accordance with the Requirements of

                              MPE Calculation for
                           FCC Part 15.247, Subpart C,
                             FCC Part 15 Subpart D
                              IC RSS-210, Issue 8,
                              IC RSS-213, Issue 2
                                             Issued to
                                     Revolabs, Inc.
                               144 North Road, Suite 3250
                                   Sudbury, MA 01776

                                              For the
                                 flx Base Station
                         Model Number: 10-FLXBASE-POTS

                                       FCC ID: T5V10FLX
                                        IC: 6455A-10FLX

                              Report Issued on August 3, 2011

                                            Tested by




This test report shall not be reproduced, except in full, without written permission from Compliance
Worldwide, Inc.


                   Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
                                     (603) 887 3903 Fax 887 6445
                               http://www.complianceworldwide.com


Test Number: 197-11A                                                               Issue Date: 08/3/2011

RF Exposure Requirements:                1.1307(b)(1) and 1.1.307(b)(2): Systems operating
                                         under the provision of this section shall be operated in a
                                         manner that ensures that the public is not exposed to
                                         radio frequency energy levels in excess of the
                                         Commission’s guidelines.

RF Radiation Exposure Limit: 1.1310: As specified in this section, the Maximum
                             Permissible Exposure (MPE) limit shall be used to
                             evaluate the environmental impact of human exposure
                             to radio frequency (RF) radiation as specified in Section
                             1.1307(b), except in the case of portable devices which
                             shall be evaluated according to the provisions of Sec
                             2.1093 of this chapter.

Test Results:                            Compliant. A summation of the power densities of each
                                         of the individual radios shows that the combination of
                                         the two radios are in compliance with the limit.



              MPE          DUT Output         DUT              Power          Power
                                                                                           Limit
Channel     Distance         Power           Antenna          Density        Density                 Result
                                                                                         (mW/cm2)
              (cm)           (dBm)          Gain (dBi)       (mW/cm2)        (W/m2)
                (1)            (2)              (3)              (4)            (4)         (5)
Bluetooth       20            3.512            2.00          0.0007111      0.0071110      1.00     Compliant
 DECT           20            16.24            2.50             0.015          0.149       1.00     Compliant
  SUM           20             N/A             N/A           0.0157111      0.1581110      1.00     Compliant




                                                 Page 2 of 5
                      Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
                                         (603) 887 3903 Fax 887 6445
                                            http://www.cw-inc.com


Test Number: 197-11A                                                                   Issue Date: 08/3/2011
6. Measurement Data (continued) from Test Report #179-11R3
  6.13. Public Exposure to Radio Frequency Energy Levels (15.247(i) (1.1307 (b)(1)) RSS-
        GEN 5.5, RSS 102

                                  DUT        DUT
                  MPE                                        Power Density
                                 Output     Antenna                                      Limit
        Channel Distance         Power       Gain                                      (mW/cm2)
                  (cm)                                                                             Result
       Frequency                 (dBm)       (dBi)
                                                         (mW/cm2)          (W/m2)
                        (1)        (2)         (3)                   (4)                 (5)
           2402        20.0       3.512        2.0       0.0007111         0.0071110      1       Compliant
           2441        20.0       3.296        2.0       0.0006766         0.0067660      1       Compliant
           2480        20.0       3.257        2.0       0.0006705         0.0067055      1       Compliant


                                                      OP + AG
                                          PD =
                                                     (4 x π x d²)

                                    • PD = Power Density (mW/cm2)
                                    • OP = DUT Output Power (dBm)
                                    • AG = DUT Antenna Gain (dBi)
                                    • d   = MPE Distance (cm)

           Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a transmitting
      1.   device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters
           of the body of the user.
      2.   Section 6.6 of this test report.
           Antenna gain is calculated from the measured field strength and maximum peak conducted output
      3.
           power.
      4.   Power density is calculated from power measurement and antenna gain.
           Reference CFR 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section (B): Limits
      5.
           for General Population/Uncontrolled Exposure.




                                                 Page 3 of 5
                     Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
                                        (603) 887 3903 Fax 887 6445
                                           http://www.cw-inc.com


Test Number: 197-11A                                                                Issue Date: 08/3/2011
6. Measurement Data (continued)
    6.13. Public Exposure to Radio Frequency Energy Levels (15.247(i) (1.1307 (b)(1)) RSS-
          GEN 5.5, RSS 102



                                                                            Measured
                                          Channel          Measured
                                                                             Output
                           Channel       Frequency          Power
                                                                             Power
                                           (MHz)            (dBm)
                                                                              (mW)
                             Low             2402             3.51           2.2449
                            Middle           2441             3.30            2.1360
                             High            2480             3.26            2.1169




        RSS-102 Section 2.5, 2.5.1 & 2.5.2 Requirements:

        2.5 - All transmitters are exempt from routine SAR and RF exposure evaluations provided that
output power complies with the power levels of sections 2.5.1 or 2.5.2. If the equipment under test (EUT)
meets the requirements of sections 2.5.1 or 2.5.2, applicants are only required to submit a properly signed
declaration of compliance (see Annex C).

       2.5.1 - SAR evaluation is required if the separation distance between the user and the radiating
element of the device is less than or equal to 20 cm, except when the device operates as follows:
       • above 2.2 GHz and up to 3 GHz inclusively, and with output power (i.e. the higher of the
conducted or radiated (e.i.r.p.) source-based, time-averaged output power) that is less than or equal to 20
mW for general public use and 100 mW for controlled use

        2.5.2 - RF exposure evaluation is required if the separation distance between the user and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:
        • at or above 1.5 GHz and the maximum e.i.r.p. of the device is equal to or less than 5 W.




                                                    Page 4 of 5
                       Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
                                          (603) 887 3903 Fax 887 6445
                                             http://www.cw-inc.com


Test Number: 197-11A                                                                      Issue Date: 08/3/2011
6. Measurement Data (continued) from Test Report #197-11
    6.11. Public Exposure to Radio Frequency Energy Levels (1.1307 (b)(1))
          RSS-GEN 5.5, RSS 102
       6.11.1. MPE Power Density Table


                  MPE        DUT Output         DUT                   Power Density             Limit
 Channel        Distance       Power           Antenna                                                    Result
                                                                                              (mW/cm2)
                  (cm)         (dBm)          Gain (dBi)
                                                               (mW/cm2)          (W/m2)
                  (1)            (2)              (3)                      (4)                  (5)
   TX4            20            16.13            2.50            0.015           0.145           1       Compliant
   TX2            20            16.23            2.50            0.015           0.149           1       Compliant
   TX0            20            16.24            2.50            0.015           0.149           1       Compliant

                                                         OP + AG
                                             PD =
                                                        (4 x π x d²)
                                              PD = Power Density
                                              OP = DUT Output Power (dBm)
                                              AG = Antenna Gain (dBi)
                                               D = MPE Distance

           1.   Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a
                transmitting device designed to be used so that the radiating structure(s) of the device is/are
                within 20 centimeters of the body of the user.
           2.   Section 6.3 of this test report.
           3.   Data supplied by the client.
           4.   Power density is calculated from conducted power output measurement and antenna gain.
           5.   Reference CFR 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section
                (B): Limits for General Population/Uncontrolled Exposure.

         RSS-102 Section 2.5, 2.5.1 & 2.5.2 Requirements:

        2.5 - All transmitters are exempt from routine SAR and RF exposure evaluations provided that
output power complies with the power levels of sections 2.5.1 or 2.5.2. If the equipment under test (EUT)
meets the requirements of sections 2.5.1 or 2.5.2, applicants are only required to submit a properly signed
declaration of compliance (see Annex C).

        2.5.1 - SAR evaluation is required if the separation distance between the user and the radiating
element of the device is less than or equal to 20 cm, except when the device operates as follows:
        • above 2.2 GHz and up to 3 GHz inclusively, and with output power (i.e. the higher of the
conducted or radiated (e.i.r.p.) source-based, time-averaged output power) that is less than or equal to 20
mW for general public use and 100 mW for controlled use
        2.5.2 - RF exposure evaluation is required if the separation distance between the user and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:
        • at or above 1.5 GHz and the maximum e.i.r.p. of the device is equal to or less than 5 W.