Test Report for NII

FCC ID: T58WF2780R

Test Report

Download: PDF
FCCID_2434575

                      FCC Radio Test Report
                              FCC ID: T58WF2780R
           This report concerns (check one):        Original Grant    Class II Change

            Project No.        :   1409C014
            Equipment          :   AC1200 Wireless Dual Band Gigabit Router
            Model Name         :   WF2880
            Applicant          :   NETIS SYSTEMS CO., LTD
            Address            :   4F&5F R&D Building, Oriental Cyberport, High-Tech
                                   Industrial Park, Nanshan, Shenzhen, China.



            Date of Receipt    :   Sep. 01, 2014
            Date of Test       :   Sep. 01, 2014 ~ Oct. 08, 2014
            Issued Date        :   Oct. 17, 2014
            Tested by          :   BTL Inc.



            Testing Engineer                :
                                                            (David Mao)


            Technical Manager               :
                                                            (Leo Hung)


            Authorized Signatory            :
                                                            (Steven Lu)




                   BTL                            INC.
        No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                           Guangdong, China.
           TEL: +86-769-8318-3000     FAX: +86-769-8319-6000




Report No.: BTL-FCCP-2-1409C014                                                  Page 1 of 29


   Declaration
   BTL represents to the client that testing is done in accordance with standard procedures as applicable and
   that test instruments used has been calibrated with the standards traceable to National Measurement
   Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A.
   BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility
   to ensure that additional production units of this model are manufactured with the identical electrical and
   mechanical components. BTL shall have no liability for any declarations, inferences or generalizations
   drawn by the client or others from BTL issued reports.
   BTL’s reports must not be used by the client to claim product endorsement by the authorities or any
   agency of the Government.
   This report is the confidential property of the client. As a mutual protection to the clients, the public and
   BTL-self, extracts from the test report shall not be reproduced except in full with BTL’s authorized written
   approval.
   BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements,
   and accredited by the conformity assessment authorities listed in this test report.
   Limitation
   For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
   test report is (are) included in the conformity assessment authorities acceptance respective.




Report No.: BTL-FCCP-2-1409C014                                                                Page 2 of 29


                                  Table of Contents              Page


    1 . CERTIFICATION                                                   5
    2 . SUMMARY OF TEST RESULTS                                         6
       2.1 TEST FACILITY                                                7
       2.2 MEASUREMENT UNCERTAINTY                                      7
    3 . GENERAL INFORMATION                                             8
       3.1 GENERAL DESCRIPTION OF EUT                                   8
       3.2 DESCRIPTION OF TEST MODES                                 10
       3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING              11
       3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12
       3.5 DESCRIPTION OF SUPPORT UNITS                              12
    4 . EMC EMISSION TEST                                            13
       4.1     CONDUCTED EMISSION MEASUREMENT                        13
             4.1.1 POWER LINE CONDUCTED EMISSION                     13
             4.1.2 MEASUREMENT INSTRUMENTS LIST                      13
             4.1.3 TEST PROCEDURE                                    14
             4.1.4 DEVIATION FROM TEST STANDARD                      14
             4.1.5 TEST SETUP                                        14
             4.1.6 EUT OPERATING CONDITIONS                          14
             4.1.7 TEST RESULTS                                      15
       4.2 RADIATED EMISSION MEASUREMENT                             18
          4.2.1 RADIATED EMISSION LIMITS                             18
          4.2.2 MEASUREMENT INSTRUMENTS LIST                         19
          4.2.3 TEST PROCEDURE                                       19
          4.2.4 DEVIATION FROM TEST STANDARD                         20
          4.2.5 TEST SETUP                                           20
          4.2.6 EUT OPERATING CONDITIONS                             20
          4.2.7 TEST RESULTS-BETWEEN 30MHZ - 1000MHZ                 21
    5 . EUT TEST PHOTO                                               28




Report No.: BTL-FCCP-2-1409C014                                Page 3 of 29


                                  REPORT ISSUED HISTORY

          Issued No.                        Description                  Issued Date
    NEI-FCCP-2-1402C047      Original Report.                            Apr. 10, 2014
                             Compared with previous report
                             (NEI-FCCP-2-1402C047), added a USB port,
                             the adapter and model name are changed,
   BTL-FCCP-2-1409C014       the RF module is the same, Conducted        Oct. 17, 2014
                             Emission and Radiated Emission (Below
                             1GHz) have been re-evaluated and recorded
                             in the test report.




Report No.: BTL-FCCP-2-1409C014                                             Page 4 of 29


 1. CERTIFICATION

    Equipment :        AC1200 Wireless Dual Band Gigabit Router
    Brand Name :       netis
    Model Name :       WF2880
    Applicant    :     NETIS SYSTEMS CO., LTD
    Manufacturer :     Shenzhen Netcore Industrial Ltd.
    Address      :     4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan,
                       Shenzhen, China.
    Factory        :   Dongguan City Netcore Network Technology Co.,Ltd.
    Address        :   No. 10-1, Sankeng Road, Qinghutou, Tangxia Town, Dongguan City
    Date of Test   :   Sep. 01, 2014 ~ Oct. 08, 2014
    Test Item      :   ENGINEERING SAMPLE
    Standard(s)    :   FCC Part15, Subpart E(15.407) / ANSI C63.4 : 2009;
                       FCC KDB 789033 D01 General UNII Test Procedures v01r03 .

 The above equipment has been tested and found compliance with the requirement of the relative
 standards by BTL Inc..
 The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
 BTL-FCCP-2-1409C014) were obtained utilizing the test procedures, test instruments, test sites
 that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment
 standard and technical standard(s).

 Test result included in this report is only for the 5150MHz~5250MHz Mode part of the
 product.




Report No.: BTL-FCCP-2-1409C014                                                     Page 5 of 29


 2. SUMMARY OF TEST RESULTS

 Test procedures according to the technical standard(s):
                                       FCC Part15, Subpart E

         Standard(s)
                                            Test Item               Judgment       Remark
           Section

           15.207            AC Power Line Conducted Emissions       PASS

          15.407(a)                26dB Spectrum Bandwidth            N/A

          15.407(a)           Maximum Conducted Output Power          N/A

          15.407(a)                  Power Spectral Density           N/A

          15.407(a)                      Peak Excursion               N/A

          15.407(a)                   Radiated Emissions             PASS

          15.407(b)                  Band Edge Emissions              N/A

          15.407(g)                    Frequency Stability            N/A

           15.203                    Antenna Requirements             N/A


 NOTE:
    (1)” N/A” denotes test is not applicable in this test report.




Report No.: BTL-FCCP-2-1409C014                                                Page 6 of 29


 2.1 TEST FACILITY
    The test facilities used to collect the test data in this report is DG-C02/DG-CB03 at the location
   of No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China.523792
    BTL's test firm number for FCC: 319330
 2.2 MEASUREMENT UNCERTAINTY
   The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
   standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
   approximately 95%.

    A. Conducted Measurement :

       Test Site   Method      Measurement Frequency Range           U,(dB)           NOTE
       DG-C02      CISPR            150 KHz ~ 30MHz                   1.94


    B. Radiated Measurement :

                              Measurement Frequency          Ant.
       Test Site   Method                                            U,(dB)           NOTE
                                     Range                   H/V
                                  9KHz~30MHz                  V        3.79
                                  9KHz~30MHz                  H        3.57
                                30MHz ~ 200MHz                V        3.82
                                30MHz ~ 200MHz                H        3.60
                               200MHz ~ 1,000MHz              V        3.86
       DG-CB03     CISPR
                               200MHz ~ 1,000MHz              H        3.94
                                  1GHz~18GHz                  V        3.12
                                  1GHz~18GHz                  H        3.68
                                 18GHz~40GHz                  V        4.15
                                 18GHz~40GHz                  H        4.14




Report No.: BTL-FCCP-2-1409C014                                                        Page 7 of 29


 3. GENERAL INFORMATION

 3.1 GENERAL DESCRIPTION OF EUT


   Equipment                  AC1200 Wireless Dual Band Gigabit Router
   Brand Name                 netis
   Model Name                 WF2880
   Mode Different             N/A

                               Operation Frequency       Band 1:5150MHz~5250MHz
                               Modulation Type           OFDM
                               Bit Rate of Transmitter   300Mbps
                               Antenna Designation
                                                         Please see note 3.(Page 10)
                               Antenna Gain(Peak)
   Product Description                               802.11a: 13.72 dBm
                                                     802.11n (20M): 15.78 dBm
                                                     802.11n (40M): 15.63 dBm
                              Output Power (Max.)
                                                     802.11ac (20M): 15.84 dBm
                                                     802.11ac (40M): 15.63 dBm
                                                     802.11ac (80M): 15.64 dBm
                              More details of EUT technical specification, please refer to the
                              User's Manual.
                              DC Voltage Supplied from AC Adapter.
   Power Source
                              Brand/Model: GOSPELL / G0612U-120-150
   Power Rating               I/P: AC 100-240V~ 50/60Hz 0.5A MAX O/P: DC 12V 1.5A

 Note:
 1. For a more detailed features description, please refer to the manufacturer’s specifications or the
    User's Manual.




Report No.: BTL-FCCP-2-1409C014                                                        Page 8 of 29


    2. Channel List:
                802.11a / 802.11n          802.11n 40M/802.11ac
                                                                          802.11ac 80MHz
            20MHz/802.11ac 20MHz                  40MHz
                     Band 1                       Band 1                      Band 1
                          Frequency                   Frequency                  Frequency
             Channel                        Channel                   Channel
                            (MHz)                       (MHz)                       (MHz)
                36           5180             38         5190           42           5210
                40           5200             46         5230
                44           5220
                48           5240

    3. Antenna Specification:
                                                                                          Gain
               Ant.    Manufacturer     Model Name      Antenna Type      Connector
                                                                                          (dBi)
                 6                      RF21C00077A Dipole Antenna           N/A          5.88

                 7                      RF21C00073A Dipole Antenna           N/A          5.88
         Note:
         The EUT incorporates a MIMO function. Physically, the EUT provides two completed
         transmitters and two receivers (2T2R). all transmit signals are completely uncorrelated,
         then,Direction gain = GANT, that is Directional gain=5.88dBi

    4.
            Operating Mode                             1TX                         3TX


                          802.11a                    V (ANT 6)                      -


                      802.11n(20MHz)                     -                V (ANT 6 + ANT 7)

                      802.11n(40MHz)                     -                V (ANT 6 + ANT 7)

                      802.11ac(20MHz)                    -                V (ANT 6 + ANT 7)

                      802.11ac(40MHz)                    -                V (ANT 6 + ANT 7)

                      802.11ac(80MHz)                    -                V (ANT 6 + ANT 7)




Report No.: BTL-FCCP-2-1409C014                                                          Page 9 of 29


  3.2 DESCRIPTION OF TEST MODES

     To investigate the maximum EMI emission characteristics generates from EUT, the test system
     was pre-scanning tested base on the consideration of following EUT operation mode or test
     configuration mode which possible have effect on EMI emission level. Each of these EUT
     operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

       Pretest Test Mode                          Description
            Mode 1                  TX A Mode / CH36, CH40, CH48(Band 1)
            Mode 2                 TX N20 Mode / CH36, CH40, CH48(Band 1)
            Mode 3                    TX N40 Mode / CH38, CH46 (Band 1)
            Mode 4                TX AC N20 Mode / CH36, CH40, CH48(Band 1)
            Mode 5                  TX AC N40 Mode / CH38, CH46 (Band 1)
            Mode 6                     TX AC N80 Mode / CH42 (Band 1)
            Mode 7                                 TX Mode

     The EUT system operated these modes were found to be the worst case during the
     pre-scanning test as following:

                                    For Conducted Test
        Final Test Mode                           Description
            Mode 7                                 TX Mode

                                     For Radiated Test
        Final Test Mode                           Description
            Mode 1                  TX A Mode / CH36, CH40, CH48(Band 1)
            Mode 2                 TX N20 Mode / CH36, CH40, CH48(Band 1)
            Mode 3                    TX N40 Mode / CH38, CH46 (Band 1)
            Mode 4                TX AC N20 Mode / CH36, CH40, CH48(Band 1)
            Mode 5                  TX AC N40 Mode / CH38, CH46 (Band 1)
            Mode 6                  TX AC N80 Mode / CH42 (Band 1)
     Note: For Radiated Below 1G test, the 802.11a mode is found to be the worst case and
     recorded.




Report No.: BTL-FCCP-2-1409C014                                                   Page 10 of 29


 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING
       During testing channel & power controlling software provided by the customer was used to
       control the operating channel as well as the output power level. The RF output power
       selection is for the setting of RF output power expected by the customer and is going to be
       fixed on the firmware of the final end product


            Test software version                              Cart
                  Frequency             5180 MHz            5200MHz            5240 MHz
                   A Mode                   23                  22                 21
                  N20 Mode                  30                  29                 28
                 AC 20 Mode                 20                  19                 17

            Test software version                              Cart
                  Frequency             5190 MHz            5230MHz
                  N40 Mode                 30                  29
                 AC 40 Mode                27                  27

            Test software version                              Cart
                  Frequency             5210 MHz
                 AC 80 Mode                23




Report No.: BTL-FCCP-2-1409C014                                                      Page 11 of 29


 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED




                                                          EUT




 3.5 DESCRIPTION OF SUPPORT UNITS

 The EUT has been tested as an independent unit together with other necessary accessories or
 support units. The following support units or accessories were used to form a representative test
 configuration during the tests.

  Item       Equipment       Mfr/Brand      Model/Type No.      FCC ID/IC    Series No.        Note
   -             -               -                -                 -              -

   Item      Shielded Type   Ferrite Core        Length                     Note
       -             -               -                -                       -

   Note:
       (1)    The support equipment was authorized by Declaration of Confirmation.




Report No.: BTL-FCCP-2-1409C014                                                        Page 12 of 29


 4. EMC EMISSION TEST

 4.1 CONDUCTED EMISSION MEASUREMENT

  4.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)

                                     Class A (dBuV)                 Class B (dBuV)
    FREQUENCY (MHz)
                               Quasi-peak       Average        Quasi-peak        Average
            0.15 -0.5             79.00          66.00          66 - 56 *        56 - 46 *
            0.50 -5.0             73.00          60.00           56.00            46.00
            5.0 -30.0             73.00          60.00           60.00            50.00
          Note:
            (1) The tighter limit applies at the band edges.
            (2) The limit of " * " marked band means the limitation decreases linearly with the
                logarithm of the frequency in the range.

  4.1.2 MEASUREMENT INSTRUMENTS LIST

  Item Kind of Equipment       Manufacturer        Type No.         Serial No.        Calibrated until
   1            LISN              EMCO                3816/2        00052765          Mar. 29, 2015
   2            LISN               R&S             ENV216            101447           Mar. 29, 2015
   3        Test Cable              N/A               C_17               N/A          Mar. 14, 2015
            EMI TEST
   4                               R&S             ESCS30          833364/017         Mar. 29, 2015
            RECEIVER
   5      50Ω Terminator           SHX            TF2-3G-A          08122902          Mar. 29, 2015
           Measurement                             EZ-EMC
   6                               Fara                                  N/A                 N/A
             Software                          Ver.NB-03A1-01

       Remark: “N/A” denotes no model name, serial no. or calibration specified.
               All calibration period of equipment list is one year.




Report No.: BTL-FCCP-2-1409C014                                                           Page 13 of 29


  4.1.3 TEST PROCEDURE
   a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
      to the power mains through a line impedance stabilization network (LISN). All other support
      equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
      impedance for the measuring instrument.
   b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
      and forth in the center forming a bundle 30 to 40 cm long.
   c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
      cable may be terminated, if required, using the correct terminating impedance. The overall
      length shall not exceed 1 m.
   d. LISN at least 80 cm from nearest part of EUT chassis.
   e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
  4.1.4 DEVIATION FROM TEST STANDARD
  No deviation


  4.1.5 TEST SETUP




  4.1.6 EUT OPERATING CONDITIONS
  The EUT was configured for testing in a typical function (as a customer would normally use it).
  The EUT was programmed to be in continuously transmitting/TX Mode mode.




Report No.: BTL-FCCP-2-1409C014                                                        Page 14 of 29


  4.1.7 TEST RESULTS

 Remark:
     (1) All readings are QP Mode value unless otherwise stated AVG in column of『Note』
                                                                                     . If the QP
         Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
         shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
         but AVG Mode didn‘t perform.In this case, a “ * ” marked in AVG Mode column of
         Interference Voltage Measured.
     (2) Measuring frequency range from 150KHz to 30MHz.




Report No.: BTL-FCCP-2-1409C014                                                   Page 15 of 29


                   AC1200 Wireless Dual
 EUT:                                     Model Name:          WF2880
                   Band Gigabit Router
 Temperature:      24 ℃                   Relative Humidity:   55 %
 Test Power:       AC 120V/60Hz           Phase:               Line
 Test Mode :       TX Mode




Report No.: BTL-FCCP-2-1409C014                                         Page 16 of 29


                   AC1200 Wireless Dual
 EUT:                                     Model Name:          WF2880
                   Band Gigabit Router
 Temperature:      24 ℃                   Relative Humidity:   55 %
 Test Power:       AC 120V/60Hz           Phase:               Neutral
 Test Mode :       TX Mode




Report No.: BTL-FCCP-2-1409C014                                          Page 17 of 29


  4.2 RADIATED EMISSION MEASUREMENT

  4.2.1 RADIATED EMISSION LIMITS (Frequency Range 9kHz-1000MHz)

  20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall
  within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to
  be followed.
           Frequencies                  Field Strength          Measurement Distance
             (MHz)                   (micorvolts/meter)                 (meters)
          0.490~1.705                  24000/F(KHz)                        30
           1.705~30.0                        30                            30
             30~88                           100                            3
             88~216                          150                            3
            216~960                          200                            3
           Above 960                         500                            3


       Notes
          (1) The limit for radiated test was performed according to FCC PART 15C.
          (2) The tighter limit applies at the band edges.
    LIMITS OF UNWANTED EMISSION OUT OF THE RESTRICTED BANDS

             Frequencies                                          Equivalent Field Strength
                                        EIRP Limit (dBm)
                (MHz)                                                  at 3m (dBµV/m)
             5150~5250                         -27                           68.3
             5250~5350                         -27                           68.3
             5470~5725                         -27                           68.3
             5725~5825                         -27                           68.3
                                             -17                         78.3
    NOTE: The following formula is used to convert the equipment isotropic radiated power (eirp) to
    field strength:

                                             µV/m, where P is the eirp (Watts)




Report No.: BTL-FCCP-2-1409C014                                                         Page 18 of 29


  4.2.2 MEASUREMENT INSTRUMENTS LIST


  Item Kind of Equipment      Manufacturer         Type No.          Serial No.     Calibrated until
   1          Antenna          Schwarbeck         VULB9160          9160-3232        Mar. 29, 2015
   2          Amplifier            HP               8447D          2944A09673        Mar. 29, 2015
   3          Receiver          AGILENT             N9038A         MY52130039        Sep. 30, 2015
   4         Test Cable            N/A            C-01_CB03             N/A           Jul. 01, 2015
   5        Controller              CT              SC100               N/A               N/A
           Measurement                             EZ-EMC
   6                               Fara                                 N/A               N/A
            Software                           Ver.NB-03A1-01

       Remark: “N/A” denotes no model name, serial no. or calibration specified.
               All calibration period of equipment list is one year.

  4.2.3 TEST PROCEDURE
   a. The measuring distance of at 1.5m shall be used for measurements at frequency up to 1GHz.
       For frequencies above 1GHz, any suitable measuring distance may be used.
   b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
       semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the
       highest radiation.
   c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
       antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
       antenna are set to make the measurement.
   d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
       mode pre-scanning the measurement frequency range. Significant peaks are then marked and
       then Quasi Peak detector mode re-measured.
   e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
       EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
       performed.
    f. For the actual test configuration, please refer to the related Item –EUT Test Photos.




Report No.: BTL-FCCP-2-1409C014                                                         Page 19 of 29


  4.2.4 DEVIATION FROM TEST STANDARD
  No deviation


  4.2.5 TEST SETUP
                 Radiated Emission Test Set-Up Frequency30 - 1000MHz




                   Radiated Emission Test Set-Up Frequency Above 1 GHz




  4.2.6 EUT OPERATING CONDITIONS
  The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
  operating condition is specified in the follows during the testing.




Report No.: BTL-FCCP-2-1409C014                                                Page 20 of 29


  4.2.7 TEST RESULTS-BETWEEN 30MHZ - 1000MHZ

   Remark:
       (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
           Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
           =120KHz, Swp. Time = 0.3 sec./MHz.
       (2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
           that the Peak reading compliance with the QP Limits and then QP Mode measurement
           didn‘t perform.
       (3) Measuring frequency range from 30MHz to 1000MHz.
       (4) If the peak scan value lower limit more than 20dB, then this signal data does not show
           in table.




Report No.: BTL-FCCP-2-1409C014                                                    Page 21 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5180MHz
 Phase:            Vertical




Report No.: BTL-FCCP-2-1409C014                                             Page 22 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5180MHz
 Phase:            Horizontal




Report No.: BTL-FCCP-2-1409C014                                             Page 23 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5200MHz
 Phase:            Vertical




Report No.: BTL-FCCP-2-1409C014                                             Page 24 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5200MHz
 Phase:            Horizontal




Report No.: BTL-FCCP-2-1409C014                                             Page 25 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5240MHz
 Phase:            Vertical




Report No.: BTL-FCCP-2-1409C014                                             Page 26 of 29


                   AC1200 Wireless Dual Band
 EUT:                                          Model Name :     WF2880
                   Gigabit Router
 Temperature:      25℃                         Relative Humidity: 58 %
 Pressure:         1010 hPa                    Test Voltage :     AC 120V/60Hz
 Test Mode :       Band 1/TX A Mode 5240MHz
 Phase:            Horizontal




Report No.: BTL-FCCP-2-1409C014                                             Page 27 of 29


 5. EUT TEST PHOTO

                                  Conducted Measurement Photos




Report No.: BTL-FCCP-2-1409C014                                  Page 28 of 29


                              Radiated Measurement Photos

                                   30MHz to 1000MHz




Report No.: BTL-FCCP-2-1409C014                             Page 29 of 29



Document Created: 2014-10-31 10:47:51
Document Modified: 2014-10-31 10:47:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC