MPE-mobile device

FCC ID: T58W1R

RF Exposure Info

Download: PDF
FCCID_4106105

FCC ID: T58W1R

                                               RF Exposure Evaluation
LIMIT
The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio
frequency (RF) radiation as specified in 1.1307(b)
Limits for Maximum Permissible Exposure (MPE)
                             Electric field
 Frequency range                                       Magnetic field strength        Power density         Averaging time
                               strength                                                                 2
        (MHz)                                                   (A/m)                   (mW/cm )              (minutes)
                                (V/m)
                                           (A) Limits for Occupational/Controlled Exposures
      0.3–3.0                       614                         1.63                      *(100)                  6
                                                                                                    2
        3.0–30                  1842/f                          4.89/f                   *(900/f )                6
      30–300                        61.4                        0.163                         1.0                 6
     300–1500                        -                            -                       f/300                   6
   1500–100,000                      -                            -                           5                   6
                                    (B) Limits for General Population/Uncontrolled Exposure
     0.3–1.34                       614                         1.63                      *(100)                 30
                                                                                                    2
      1.34–30                    824/f                          2.19/f                   *(180/f )               30
      30–300                        27.5                        0.073                         0.2                30
     300–1500                        -                            -                       f/1500                 30
   1500–100,000                      -                            -                           1.0                30
Note: f = frequency in MHz


EVALUATION METHOD
                                                   2
Transmission formula: Pd = (Pout*G)/(4*pi*r )
Where
                                2
Pd = power density in mW/cm , Pout = output power to antenna in mW, G = gain of antenna in linear scale;
Pi = 3.1416, R = distance between observation point and center of the radiator in cm


TEST RESULT


    Passed                                  Not Applicable


FCC ID: T58W1R


                         Type                                   Maximum PK conducted output power(dBm)

                       802.11b                                               16.50 ~ 17.50

                       802.11g                                               15.50 ~ 16.50

                                                                Maximum PK conducted output power(dBm)
                                                                              ANT1+ANT2

                     802.11n(H20)                                            17.50 ~ 18.50

                     802.11n(H40)                                            16.50 ~ 17.50



                      Maximum conducted
         Type                                 Power Density (mW/cm2)      Limit (mW/cm2)           Result
                       output power(dBm)

        802.11b              17.50                    0.02232                 1.0000                Pass

        802.11g              16.50                    0.01773                 1.0000                Pass

  802.11n(H20)               18.50                    0.05607                 1.0000                Pass

  802.11n(H40)               17.50                    0.04454                 1.0000                Pass



Note:
 1) Antenna gain of ANT1 = Antenna gain of ANT2= 3dBi, Antenna gain of ANT1 + ANT2=3dBi + 10log(2) = 6dBi.
 2) The exposure safety distance is 20cm.



Document Created: 2018-12-03 14:37:36