Test Report

FCC ID: T2C-T41S

Test Report

Download: PDF
FCCID_3161277

                                    MRT Technology (Suzhou) Co., Ltd            Report No.: 1609ESU01201
                                    Phone: +86-512-66308358                     Report Version:        V01
                                    Fax: +86-512-66308368                       Issue Date:     10-08-2016
                                    Web: www.mrt-cert.com




                         MEASUREMENT REPORT
                                         FCC Part 15B

FCC ID:                        T2C-T41S

APPLICANT:                     YEALINK(XIAMEN) NETWORK TECHNOLOGY CO.,
                               LTD


Application Type:              Certification

Product:                       Ultra-elegant IP Phone

Model No.:                     SIP-T41S

Brand Name:                    YEALINK

FCC Classification: FCC Class B Digital Device (JBP)

FCC Rule Part(s):              FCC Part 15 Subpart B: 2016

Test Procedure(s):             ANSI C63.4: 2014

Test Date:                     September 01 ~ 18, 2016



Reviewed By                :
                                 ( Robin Wu )
Approved By                :
                                ( Marlin Chen )


The test results relate only to the samples tested.
This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures specified
in ANSI C63.4-2014. Test results reported herein relate only to the item(s) tested.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)
Co., Ltd.
 FCC ID: T2C-T41S                                                                         Page Number: 1 of 33


                                                     Report No.: 1609ESU01201


                             Revision History

   Report No.      Version     Description      Issue Date             Note

 1609ESU01201      Rev. 01     Initial report   10-08-2016             Valid




FCC ID: T2C-T41S                                             Page Number: 2 of 33


                                                                                                               Report No.: 1609ESU01201


                                                            CONTENTS
Description                                                                                                                                  Page
§2.1033 General Information ............................................................................................................ 4

1.     INTRODUCTION ........................................................................................................................ 5

      1.1.       Scope .............................................................................................................................. 5
      1.2.       MRT Test Location .......................................................................................................... 5

2.     PRODUCT INFORMATION ........................................................................................................ 6

      2.1.       Equipment Description .................................................................................................... 6
      2.2.       Test Configuration ........................................................................................................... 6
      2.3.       Test System Details ........................................................................................................ 8
      2.4.       Test Software .................................................................................................................. 8
      2.5.       EMI Suppression Device(s)/Modifications ....................................................................... 8
      2.6.       Labeling Requirements ................................................................................................... 8

3.     DESCRIPTION OF TEST ........................................................................................................... 9

      3.1.       Evaluation Procedure ...................................................................................................... 9
      3.2.       AC Line Conducted Emissions ........................................................................................ 9
      3.3.       Radiated Emissions....................................................................................................... 10

4.     TEST EQUIPMENT CALIBRATION DATE .............................................................................. 11

5.     MEASUREMENT UNCERTAINTY ........................................................................................... 12

6.     TEST RESULT ......................................................................................................................... 13

      6.1.       Summary ....................................................................................................................... 13
      6.2.       Conducted Emission Measurement .............................................................................. 14
      6.2.1.        Test Limit ................................................................................................................... 14
      6.2.2.        Test Setup ................................................................................................................. 14
      6.2.3.        Test Result of Conducted Emissions ......................................................................... 15
      6.3.       Radiated Emission Measurement ................................................................................. 19
      6.3.1.        Test Limit ................................................................................................................... 19
      6.3.2.        Test Setup ................................................................................................................. 19
      6.3.3.        Test Result ................................................................................................................. 21

7.     CONCLUSION.......................................................................................................................... 33




FCC ID: T2C-T41S                                                                                                       Page Number: 3 of 33


                                                                        Report No.: 1609ESU01201


§2.1033 General Information
Applicant:                    YEALINK(XIAMEN) NETWORK TECHNOLOGY CO., LTD
Applicant Address:            309, 3th Floor, No.16, Yun Ding North Road, Huli District, Xiamen
                              City, Fujian, P.R. China
Manufacturer:                 YEALINK(XIAMEN) NETWORK TECHNOLOGY CO., LTD
Manufacturer Address:         309, 3th Floor, No.16, Yun Ding North Road, Huli District, Xiamen
                              City, Fujian, P.R. China
Test Site:                    MRT Technology (Suzhou) Co., Ltd
Test Site Address:            D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong
                              Economic Development Zone, Suzhou, China
MRT FCC Registration No.: 809388
Model No.:                    SIP-T41S
FCC ID:                       T2C-T41S
Test Device Serial No.:       N/A              Production     Pre-Production       Engineering
FCC Classification:           FCC Class B Digital Device (JBP)


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Tian’edang Rd., Suzhou, China.
 MRT facility is a FCC registered (MRT Reg. No. 809388) test facility with the site description
  report on file and has met all the requirements specified in Section 2.948 of the FCC Rules.
 MRT facility is an IC registered (MRT Reg. No. 11384A-1) test laboratory with the site
  description on file at Industry Canada.
 MRT facility is a VCCI registered (R-4179, G-814,
  C-4664, T-2206) test laboratory with the site description
  on file at VCCI Council.
 MRT Lab is accredited to ISO 17025 by the American
  Association for Laboratory Accreditation (A2LA) under
  the American Association for Laboratory Accreditation
  Program (A2LACert. No.3628.01) in EMC,
  Telecommunications and Radio testingfor FCC,
  Industry Canada, EU and TELEC Rules.




FCC ID: T2C-T41S                                                               Page Number: 4 of 33


                                                                            Report No.: 1609ESU01201



1.    INTRODUCTION
1.1. Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices
including intentional and/or unintentional radiators for compliance with the technical rules and
regulations of the Federal Communications Commission and the Industry Canada Certification and
Engineering Bureau.



1.2. MRT Test Location
The map below shows the location of the MRT LABORATORY, its proximity to the Taihu Lake.
These measurement tests were conducted at the MRT Technology (Suzhou) Co., Ltd. Facility
located at D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong Economic
Development Zone, Suzhou, China. The detailed description of the measurement facility was found
to be in compliance with the requirements of § 2.948 according to ANSI C63.4-2009 on September
30, 2013.




FCC ID: T2C-T41S                                                                 Page Number: 5 of 33


                                                                       Report No.: 1609ESU01201



2.    PRODUCT INFORMATION
2.1. Equipment Description
Product Name                     Ultra-elegant IP Phone
Model No.                        SIP-T41S
Adapter #1                       M/N: YLPS051200B-US
                                 INPUT: 100-240V ~ 50/60Hz,250mA
                                 OUTPUT: 5Vdc, 1.2A
Adapter #2                       M/N: YLPS051200C-US
                                 INPUT: 100-240V ~ 50/60Hz, 250mA
                                 OUTPUT: 5Vdc, 1.2A



2.2. Test Configuration
The Ultra-elegant IP Phone FCC ID: T2C-T41S was tested per the guidance FCC Part 15 Subpart
B: 2016 and ANSI C63.4: 2014 was used to reference the appropriate EUT setup for radiated
spurious emissions testing and AC line conducted testing.

Connection Diagram(Mode 1 & 2)




FCC ID: T2C-T41S                                                           Page Number: 6 of 33


                                                        Report No.: 1609ESU01201


Connection Diagram(Mode 3)




Signal Cable Type            Signal Cable Description
A      Power Cable           Non-shielding, 1.8m
B      Telecom Cable         Non-shielding, 0.1m
C      LAN Cable             Non-shielding, > 10m
D      LAN Cable             Non-shielding, > 10m
E      LAN Cable             Non-shielding, 1m




FCC ID: T2C-T41S                                            Page Number: 7 of 33


                                                                            Report No.: 1609ESU01201



2.3. Test System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:

Product                Manufacturer     Model No.     Serial No.             Power Cord
1    Headset           Yealink          N/A           N/A                    N/A
2    USB Flash disk HP                  X750W         N/A                    N/A
3    EHS Box           Yealink          GN9330e       N/A                    N/A
     8-port 10/100
     Unmanaged
4                      D-Link           DES-1008P S0091F7000489              Non-Shielded, 2m
     Switch with 4
     PoE ports
5    IP Phone          Yealink          SIP-T41S      MAC 001565B38ED7 Non-shielding, 1.8m
6    Notebook          Lenovo           E430c         MP-4CFX213/10          Non-Shielded, 1.8m



2.4. Test Software
Not applicable.



2.5. EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and/or no modifications were made during testing.



2.6. Labeling Requirements
Per 2.1074 & 15.19; Docket 95-19
The label shall be permanently affixed at a conspicuous location on the device; instruction manual or
pamphlet supplied to the user and be readily visible to the purchaser at the time of purchase.
However, when the device is so small wherein placement of the label with specified statement is not
practical, only the FCC ID must be displayed on the device per Section 15.19(a)(5). Please see
attachment for FCC ID label and label location.




FCC ID: T2C-T41S                                                                 Page Number: 8 of 33


                                                                             Report No.: 1609ESU01201



3.    DESCRIPTION OF TEST
3.1. Evaluation Procedure
The measurement procedures described in the American National Standard for Methods of
Measurement of Radio-Noise Emission from Low-Voltage Electrical Equipment in the Range of 9kHz
to 18GHz (ANSI C63.4-2014) was used in the measurement of the Ultra-elegant IP Phone FCC ID:
T2C-T41S.
Deviation from measurement procedure…………………………….....................................None



3.2. AC Line Conducted Emissions
The line-conducted facility is located inside an 8'x4'x4' shielded enclosure. A 1m x 2m wooden table
80cm high is placed 40cm away from the vertical wall and 80cm away from the sidewall of the
shielded room. Two 10kHz-30MHz, 50Ω/50uH Line-Impedance Stabilization Networks (LISNs) are
bonded to the shielded room floor. Power to the LISNs is filtered by external high-current
high-insertion loss power line filters. These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.
The EUT is powered from one LISN and the support equipment is powered from the second LISN. If
the EUT is a DC-powered device, power will be derived from the source power supply it normally will
be powered from and this supply line(s) will be connected to the second LISN. All interconnecting
cables more than 1 meter were shortened to a 1 meter length by non-inductive bundling (serpentine
fashion) and draped over the back edge of the test table. All cables were at least 40cm above the
horizontal reference ground-plane. Power cables for support equipment were routed down to the
second LISN while ensuring that that cables were not draped over the second LISN.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to
warm up to their normal operating condition. The RF output of the LISN was connected to the
receiver and exploratory measurements were made to determine the frequencies producing the
maximum emission from the EUT. The receiver was scanned from 150 kHz to 30 MHz. The detector
function was set to peak mode for exploratory measurements while the bandwidth of the analyzer
was set to 9 kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission. Each emission was also maximized by varying: power lines,
the mode of operation or resolution, clock or data exchange speed, scrolling H pattern to the EUT
and/or support equipment whichever determined the worst-case emission. Once the worst case
emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions are used for final measurements on the same test site.
Line conducted emissions test results are shown in Section 6.2.




FCC ID: T2C-T41S                                                                  Page Number: 9 of 33


                                                                              Report No.: 1609ESU01201



3.3. Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final
measurements and exploratory measurements, when necessary. The measurement area is
contained within the semi-anechoic chamber which is shielded from any ambient interference. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the
antenna mast in such a way so as to maximize the reduction of reflections. For measurements below
1GHz, the absorbers are removed. An MF Model 210SS turntable is used for radiated measurement.
It is a continuously rotatable, remote controlled, metallic turntable and 2 meters (6.56 ft.) in diameter.
The turn table is flush with the raised floor of the chamber in order to maintain its function as a
ground plane. An 80cm high PVC support structure is placed on top of the turntable.
For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter
receive antenna height using a broadband antenna from 30 MHz up to the upper frequency shown in
15.33(b)(1) depending on the highest frequency generated or used in the device or on which the
device operates or tunes. For frequencies above 1GHz, linearly polarized double ridge horn
antennas were used. For frequencies below 30 MHz, a calibrated loop antenna was used. When
exploratory measurements were necessary, they were performed at 1 meter test distance inside the
semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers
to determine the frequencies and modes producing the maximum emissions. Sufficient time for the
EUT, support equipment, and test equipment was allowed in order for them to warm up to their
normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x 1.5 meter
table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the
EUT were maximized and investigated. The system configuration, mode of operation, if applicable,
turntable azimuth, and receive antenna height was noted for each frequency found.
Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized
broadband and horn antennas. The test setup was configured to the setup that produced the worst
case emissions. The spectrum analyzer was set to investigate all frequencies required for testing to
compare the highest radiated disturbances with respect to the specified limits. The turntable
containing the EUT was rotated through 360 degrees and the height of the receive antenna was
varied 1 to 4 meters and stopped at the azimuth and height producing the maximum emission. Each
emission was maximized by changing the orientation of the EUT through three orthogonal planes
and changing the polarity of the receive antenna, whichever produced the worst-case emissions.
According to 3dB beam-width of horn antenna, the horn antenna should be always directed to the
EUT when rising height.




FCC ID: T2C-T41S                                                                   Page Number: 10 of 33


                                                                              Report No.: 1609ESU01201



4.     TEST EQUIPMENT CALIBRATION DATE
Conducted Emissions - SR2

Instrument                  Manufacturer Type No.          Asset No.     Cali. Interval Cali. Due Date
EMI Test Receiver           R&S                ESR7        MRTSUE06001 1 year          2016/11/03
Two-Line V-Network          R&S                ENV216      MRTSUE06002 1 year          2016/11/03
Two-Line V-Network          R&S                ENV216      MRTSUE06003 1 year          2016/11/03
Temperature/Humidity Meter Yuhuaze             HTC-2       MRTSUE06182 1 year          2016/12/20
Shielding Anechoic Chamber Mikebang            Chamber-SR2 MRTSUE06215 1 year          2017/05/10

Radiated Emissions – AC2

Instrument                  Manufacturer Type No.          Asset No.     Cali. Interval Cali. Due Date
MXE EMI Receiver            Agilent            N9038A      MRTSUE06125 1 year          2017/08/03
Microwave System Amplifier Agilent             83017A      MRTSUE06076 1 year          2017/03/29
TRILOG Antenna              Schwarzbeck VULB9162           MRTSUE06022 1 year          2016/11/07
Broad-Band Horn Antenna     Schwarzbeck BBHA9120D          MRTSUE06023 1 year          2016/11/07
Digitial Thermometer &
                            MingGao            ETH529      MRTSUE06170 1 year          2016/11/30
Hygromete
Anechoic Chamber            RIKEN              Chamber-AC2 MRTSUE06213 1 year          2017/05/10


Software                              Version                          Function
e3                                    V8.3.5                           EMI Test Software




FCC ID: T2C-T41S                                                                   Page Number: 11 of 33


                                                                          Report No.: 1609ESU01201



5.    MEASUREMENT UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed
at approximately the 95% confidence level using a coverage factor of k = 2.


AC Conducted Emission Measurement – SR2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     150kHz~30MHz: 3.5dB
Radiated Emission Measurement – AC2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     Horizontal: 30MHz~1GHz: 4.07dB
                 1GHz~18GHz: 4.16 dB
     Vertical:   30MHz~1GHz: 4.18 dB
                 1GHz~18GHz: 4.76 dB




FCC ID: T2C-T41S                                                               Page Number: 12 of 33


                                                                  Report No.: 1609ESU01201



6.     TEST RESULT
6.1. Summary
Product Name:              Ultra-elegant IP Phone
FCC ID:                    T2C-T41S
FCC Classification:        FCC Class B Digital Device (JBP)
Test Mode:                 Mode 1: Power by adapter #1 and Communicate with another IP
                           Phone
                           Mode 2: Power by adapter #2 and Communicate with another IP
                           Phone
                           Mode 3: Power by POE and Communicate with another IP Phone


     FCC Part Section(s)               Test Description                 Test Result

           15.107                     Conducted Emissions                  Pass

           15.109                     Radiated Emissions                   Pass




FCC ID: T2C-T41S                                                      Page Number: 13 of 33


                                                                          Report No.: 1609ESU01201



6.2. Conducted Emission Measurement

  6.2.1.   Test Limit

                                       FCC Part 15.107 Limits

           Frequency                              QP                               AV
             (MHz)                              (dBμV)                           (dBμV)

           0.15 - 0.50                          66 - 56                          56 - 46

            0.50 - 5.0                             56                              46

             5.0 - 30                              60                              50

 Note 1: The lower limit shall apply at the transition frequencies.
 Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to
 0.5MHz.



  6.2.2.   Test Setup




FCC ID: T2C-T41S                                                               Page Number: 14 of 33


                                                                                  Report No.: 1609ESU01201



     6.2.3.    Test Result of Conducted Emissions
 Site: SR2                                             Time: 2016/09/01 - 20:17
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Dandy Li
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: Ultra-elegant IP Phone                           Power: AC 120V/60Hz
 Note: Mode 1




 No     Flag    Mark   Frequency   Measure   Reading     Over Limit     Limit       Factor     Type
                       (MHz)       Level     Level       (dB)           (dBuV)      (dB)
                                   (dBuV)    (dBuV)
 1                     0.162       45.936    35.839      -19.425        65.361      10.097     QP
 2                     0.162       24.997    14.900      -30.364        55.361      10.097     AV
 3                     0.238       35.193    25.239      -26.972        62.166      9.954      QP
 4                     0.238       17.899    7.944       -34.267        52.166      9.954      AV
 5                     0.382       41.314    31.243      -16.922        58.236      10.071     QP
 6              *      0.382       35.506    25.436      -12.729        48.236      10.071     AV
 7                     0.542       29.656    19.511      -26.344        56.000      10.145     QP
 8                     0.542       22.391    12.246      -23.609        46.000      10.145     AV
 9                     5.634       31.486    21.398      -28.514        60.000      10.087     QP
 10                    5.634       23.948    13.861      -26.052        50.000      10.087     AV
 11                    13.482      35.138    25.080      -24.862        60.000      10.058     QP
 12                    13.482      29.815    19.757      -20.185        50.000      10.058     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).



FCC ID: T2C-T41S                                                                      Page Number: 15 of 33


                                                                                  Report No.: 1609ESU01201




 Site: SR2                                             Time: 2016/09/01 - 20:21
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Dandy Li
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: Ultra-elegant IP Phone                           Power: AC 120V/60Hz
 Note: Mode 1




 No   Flag   Mark   Frequency    Measure     Reading     Over Limit    Limit        Factor     Type
                    (MHz)        Level       Level       (dB)          (dBuV)       (dB)
                                 (dBuV)      (dBuV)
 1                  0.158        46.627      36.337      -18.942       65.568       10.290     QP
 2                  0.158        24.101      13.811      -31.468       55.568       10.290     AV
 3                  0.226        40.482      30.499      -22.113       62.595       9.982      QP
 4                  0.226        19.377      9.394       -33.218       52.595       9.982      AV
 5                  0.382        43.242      33.144      -14.993       58.236       10.099     QP
 6           *      0.382        34.420      24.322      -13.815       48.236       10.099     AV
 7                  3.222        35.811      25.934      -20.189       56.000       9.877      QP
 8                  3.222        27.383      17.506      -18.617       46.000       9.877      AV
 9                  6.558        36.605      26.454      -23.395       60.000       10.152     QP
 10                 6.558        28.119      17.967      -21.881       50.000       10.152     AV
 11                 13.482       42.149      32.051      -17.851       60.000       10.099     QP
 12                 13.482       35.467      25.368      -14.533       50.000       10.099     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: T2C-T41S                                                                      Page Number: 16 of 33


                                                                                  Report No.: 1609ESU01201




 Site: SR2                                             Time: 2016/09/01 - 20:31
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Dandy Li
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: Ultra-elegant IP Phone                           Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency    Measure     Reading     Over Limit     Limit       Factor     Type
                    (MHz)        Level       Level       (dB)           (dBuV)      (dB)
                                 (dBuV)      (dBuV)
 1                  0.158        45.668      35.357      -19.900        65.568      10.311     QP
 2                  0.158        21.903      11.592      -33.665        55.568      10.311     AV
 3                  0.190        43.088      33.059      -20.948        64.037      10.029     QP
 4                  0.190        19.745      9.716       -34.292        54.037      10.029     AV
 5                  0.294        32.403      22.404      -28.008        60.411      9.999      QP
 6                  0.294        16.348      6.348       -34.063        50.411      9.999      AV
 7                  1.274        27.242      17.344      -28.758        56.000      9.899      QP
 8                  1.274        16.171      6.272       -29.829        46.000      9.899      AV
 9                  6.578        32.228      22.084      -27.772        60.000      10.143     QP
 10                 6.578        21.630      11.487      -28.370        50.000      10.143     AV
 11                 13.418       38.339      28.271      -21.661        60.000      10.068     QP
 12          *      13.418       33.457      23.389      -16.543        50.000      10.068     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: T2C-T41S                                                                      Page Number: 17 of 33


                                                                                  Report No.: 1609ESU01201




 Site: SR2                                             Time: 2016/09/01 - 20:26
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Dandy Li
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: Ultra-elegant IP Phone                           Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency    Measure     Reading     Over Limit    Limit        Factor     Type
                    (MHz)        Level       Level       (dB)          (dBuV)       (dB)
                                 (dBuV)      (dBuV)
 1                  0.194        41.868      31.851      -21.995       63.864       10.017     QP
 2                  0.194        27.536      17.519      -26.328       53.864       10.017     AV
 3                  0.322        38.093      28.071      -21.562       59.655       10.022     QP
 4           *      0.322        32.291      22.269      -17.364       49.655       10.022     AV
 5                  0.522        32.642      22.487      -23.358       56.000       10.155     QP
 6                  0.522        25.919      15.764      -20.081       46.000       10.155     AV
 7                  3.154        34.119      24.262      -21.881       56.000       9.856      QP
 8                  3.154        25.663      15.806      -20.337       46.000       9.856      AV
 9                  3.694        33.161      23.219      -22.839       56.000       9.941      QP
 10                 3.694        25.047      15.106      -20.953       46.000       9.941      AV
 11                 4.154        32.297      22.324      -23.703       56.000       9.974      QP
 12                 4.154        23.069      13.096      -22.931       46.000       9.974      AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: T2C-T41S                                                                      Page Number: 18 of 33


                                                                        Report No.: 1609ESU01201



6.3. Radiated Emission Measurement

  6.3.1.   Test Limit

                                        FCC Part 15.109 Limits

            Frequency                           Distance                       Level
              (MHz)                               (m)                        (dBμV/m)

              30 - 88                               3                           40

             88 - 216                               3                           43.5

            216 - 960                               3                           46

            Above 960                               3                           54

  Note 1: The lower limit shall apply at the transition frequency.
  Note 2: Distance refers to the distance in meters between the measuring instrument antenna and
  the closed point of any part of the device or system.
  Note 3: E field strength (dBμV/m) = 20 log E field strength (uV/m)



  6.3.2.   Test Setup

  30MHz ~ 1GHz Test Setup:




FCC ID: T2C-T41S                                                             Page Number: 19 of 33


              1~4 m             (Antenna Tower)
   Eus         l      Antenna




(Turntable)


                                                                                    Report No.: 1609ESU01201



     6.3.3.    Test Result
 Site: AC2                                               Time: 2016/09/17 - 18:03
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                             Power: AC 120V/60Hz
 Note: Mode 1




 No     Flag    Mark   Frequency   Measure    Reading    Over      Limit        Factor   Ant    Table   Type
                       (MHz)       Level      Level      Limit     (dBuV/m)     (dB)     Pos    Pos
                                   (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                     166.770     33.640     23.520     -9.860    43.500       10.120   100    235     QP
 2                     185.200     34.019     22.630     -9.481    43.500       11.389   100    328     QP
 3                     333.125     38.842     23.360     -7.158    46.000       15.482   100    147     QP
 4                     457.770     33.030     15.460     -12.970   46.000       17.571   100    52      QP
 5                     666.805     33.419     12.410     -12.581   46.000       21.009   100    320     QP
 6              *      833.160     40.055     16.680     -5.945    46.000       23.375   100    18      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                         Page Number: 21 of 33


                                                                                    Report No.: 1609ESU01201




 Site: AC2                                               Time: 2016/09/17 - 18:03
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                             Power: AC 120V/60Hz
 Note: Mode 1




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit      Factor    Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)   (dB)      Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                           (cm)   (deg)
 1                  31.940      32.063      19.680       -7.937    40.000     12.383    100    56      QP
 2           *      53.874      35.288      20.430       -4.712    40.000     14.858    100    169     QP
 3                  63.950      33.973      21.070       -6.027    40.000     12.903    100    223     QP
 4                  125.060     29.478      18.950       -14.022   43.500     10.529    100    302     QP
 5                  499.965     37.021      18.690       -8.979    46.000     18.331    100    268     QP
 6                  833.160     36.625      13.250       -9.375    46.000     23.375    100    45      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                        Page Number: 22 of 33


                                                                                    Report No.: 1609ESU01201




 Site: AC2                                               Time: 2016/09/17 - 18:04
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                             Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit        Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)     (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1                  63.950      21.483      8.580        -18.517   40.000       12.903   100    311     QP
 2                  173.560     33.065      22.620       -10.435   43.500       10.445   100    247     QP
 3                  333.125     35.162      19.680       -10.838   46.000       15.482   100    120     QP
 4                  354.465     38.444      22.520       -7.556    46.000       15.924   100    274     QP
 5                  666.805     33.059      12.050       -12.941   46.000       21.009   100    42      QP
 6           *      826.370     38.880      15.580       -7.120    46.000       23.300   100    19      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                         Page Number: 23 of 33


                                                                                    Report No.: 1609ESU01201




 Site: AC2                                               Time: 2016/09/17 - 18:04
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                             Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit      Factor    Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)   (dB)      Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                           (cm)   (deg)
 1                  30.485      28.100      15.950       -11.900   40.000     12.150    100    32      QP
 2                  53.765      33.438      18.580       -6.562    40.000     14.858    100    248     QP
 3           *      64.004      36.946      24.060       -3.054    40.000     12.886    100    332     QP
 4                  173.560     33.075      22.630       -10.425   43.500     10.445    100    74      QP
 5                  499.965     34.021      15.690       -11.979   46.000     18.331    100    184     QP
 6                  833.645     35.635      12.250       -10.365   46.000     23.385    100    29      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                        Page Number: 24 of 33


                                                                                    Report No.: 1609ESU01201




 Site: AC2                                               Time: 2016/09/17 - 18:00
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                             Power: By PoE
 Note: Mode 3




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit        Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)     (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1                  53.765      23.548      8.690        -16.452   40.000       14.858   100    224     QP
 2                  110.995     25.272      12.520       -18.228   43.500       12.752   100    174     QP
 3                  173.560     32.965      22.520       -10.535   43.500       10.445   100    54      QP
 4                  185.360     36.353      24.950       -7.147    43.500       11.403   100    63      QP
 5                  333.125     38.762      23.280       -7.238    46.000       15.482   100    331     QP
 6           *      833.160     39.965      16.590       -6.035    46.000       23.375   100    285     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                         Page Number: 25 of 33


                                                                                    Report No.: 1609ESU01201




 Site: AC2                                               Time: 2016/09/17 - 18:00
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Lewis Huang
 Probe: VULB9162_0.03-8GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                             Power: By PoE
 Note: Mode 3




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit      Factor    Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)   (dB)      Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                           (cm)   (deg)
 1           *      33.197      36.909      24.300       -3.091    40.000     12.609    100    322     QP
 2                  53.877      36.848      21.990       -3.152    40.000     14.858    100    228     QP
 3                  63.950      35.423      22.520       -4.577    40.000     12.903    100    41      QP
 4                  110.995     32.432      19.680       -11.068   43.500     12.752    100    175     QP
 5                  185.200     33.909      22.520       -9.591    43.500     11.389    100    98      QP
 6                  499.965     36.911      18.580       -9.089    46.000     18.331    100    227     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: T2C-T41S                                                                        Page Number: 26 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:09
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                            Power: AC 120V/60Hz
 Note: Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit        Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)     (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                             (cm)   (deg)
 1                  2003.000     38.069     42.554     -35.931    74.000       -4.485   100    74      PK
 2                  2003.000     25.545     30.030     -28.455    54.000       -4.485   100    186     AV
 3                  3329.000     40.565     42.751     -33.435    74.000       -2.186   100    229     PK
 4                  3329.000     27.874     30.060     -26.126    54.000       -2.186   100    305     AV
 5                  7366.500     44.721     34.044     -29.279    74.000       10.677   100    271     PK
 6           *      7366.500     32.267     21.590     -21.733    54.000       10.677   100    19      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                        Page Number: 27 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:10
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                            Power: AC 120V/60Hz
 Note: Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit      Factor    Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)   (dB)      Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                  2003.000     39.044     43.529     -34.956    74.000     -4.485    100    186     PK
 2                  2003.000     27.025     31.510     -26.975    54.000     -4.485    100    306     AV
 3                  3337.500     37.443     39.634     -36.557    74.000     -2.191    100    296     PK
 4                  3337.500     26.759     28.950     -27.241    54.000     -2.191    100    29      AV
 5                  7451.500     44.950     34.029     -29.050    74.000     10.921    100    186     PK
 6           *      7451.500     34.281     23.360     -19.719    54.000     10.921    100    74      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                       Page Number: 28 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:09
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                            Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit        Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)     (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                             (cm)   (deg)
 1                  2003.000     40.349     44.834     -33.651    74.000       -4.485   100    338     PK
 2                  2003.000     26.545     31.030     -27.455    54.000       -4.485   100    168     AV
 3                  3337.500     39.455     41.646     -34.545    74.000       -2.191   100    27      PK
 4                  3337.500     27.489     29.680     -26.511    54.000       -2.191   100    59      AV
 5                  7536.500     45.040     34.063     -28.960    74.000       10.977   100    227     PK
 6           *      7536.500     33.497     22.520     -20.503    54.000       10.977   100    10      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                        Page Number: 29 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:09
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                            Power: AC 120V/60Hz
 Note: Mode 2




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit      Factor    Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)   (dB)      Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                  1663.000     37.220     43.465     -36.780    74.000     -6.245    100    305     PK
 2                  1663.000     23.905     30.150     -30.095    54.000     -6.245    100    116     AV
 3                  2496.000     38.744     41.788     -35.256    74.000     -3.044    100    274     PK
 4                  2496.000     26.606     29.650     -27.394    54.000     -3.044    100    16      AV
 5                  7970.000     44.863     34.089     -29.137    74.000     10.773    100    95      PK
 6           *      7970.000     33.284     22.510     -20.716    54.000     10.773    100    174     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                       Page Number: 30 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:10
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Horizontal
 EUT: Ultra-elegant IP Phone                            Power: By PoE
 Note: Mode 3




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit        Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)     (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                             (cm)   (deg)
 1                  2003.000     37.808     42.293     -36.192    74.000       -4.485   100    28      PK
 2                  2003.000     27.135     31.620     -26.865    54.000       -4.485   100    77      AV
 3                  3329.000     40.236     42.422     -33.764    74.000       -2.186   100    344     PK
 4                  3329.000     27.494     29.680     -26.506    54.000       -2.186   100    286     AV
 5                  7638.500     45.222     34.726     -28.778    74.000       10.496   100    117     PK
 6           *      7638.500     33.746     23.250     -20.254    54.000       10.496   100    68      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                        Page Number: 31 of 33


                                                                                   Report No.: 1609ESU01201




 Site: AC2                                              Time: 2016/09/17 - 18:11
 Limit: FCC_Part15.109_RE(3m)_Class B                   Engineer: Lewis Huang
 Probe: BBHA9120D_1-18GHz                               Polarity: Vertical
 EUT: Ultra-elegant IP Phone                            Power: By PoE
 Note: Mode 3




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit      Factor    Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)   (dB)      Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                  2003.000     38.468     42.953     -35.532    74.000     -4.485    100    224     PK
 2                  2003.000     25.195     29.680     -28.805    54.000     -4.485    100    314     AV
 3                  2504.500     39.279     42.428     -34.721    74.000     -3.149    100    168     PK
 4                  2504.500     26.881     30.030     -27.119    54.000     -3.149    100    37      AV
 5                  7502.500     44.548     33.502     -29.452    74.000     11.046    100    174     PK
 6           *      7502.500     33.736     22.690     -20.264    54.000     11.046    100    187     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) - Pre_Amplifier Gain (dB).




FCC ID: T2C-T41S                                                                       Page Number: 32 of 33


                                                                        Report No.: 1609ESU01201



7.    CONCLUSION
The data collected relate only the item(s) tested and show that the Ultra-elegant IP Phone FCC ID:

T2C-T41S has been tested to comply with the requirements specified in §15.107 and §15.109 of the

FCC Rules.




                                            The End
FCC ID: T2C-T41S                                                             Page Number: 33 of 33



Document Created: 2017-12-16 00:05:50
Document Modified: 2017-12-16 00:05:50

© 2024 FCC.report