Test Report

FCC ID: T2C-T29G

Test Report

Download: PDF
FCCID_2406963

                                    FCC PART 15, CLASS B

                   MEASUREMENT AND TEST REPORT
                                                             For

        Yealink (Xiamen) Network Technology Co., Ltd.
     4th-5th Floor, South Building, NO.63 WangHai Road, 2nd Software Park, Xiamen, China


                                             FCC ID: T2C-T29G

               Report Type:                                      Product Type:

               Or iginal Repor t                                 IP P hone



                       Test Engineer:       Webb Liu


                    Report Number:          RSZ140826006-00


                         Report Date:       2014-09-19

                                            Dick Zhang
                        Reviewed By:        EMC Leader

                         Prepared By:       Bay Area Compliance Laboratories Corp. (Shenzhen)
                                            6/F, the 3rd Phase of WanLi Industrial Building
                                            ShiHua Road, FuTian Free Trade Zone
                                            Shenzhen, Guangdong, China
                                            Tel: +86-755-33320018
                                            Fax: +86-755-33320008
                                            www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ140826006-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION (FCC §15.27) ..................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC§15.109 - RADIATED EMISSIONS ..................................................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  MEASUREMENT UNCERTAINTY ..................................................................................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................19
  TEST RESULTS SUMMARY ..........................................................................................................................................19
  TEST DATA ................................................................................................................................................................19




FCC Part 15, Class B                                                                                                                                     Page 2 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ140826006-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Yealink (Xiamen) Network Technology Co., Ltd.’s product, model number: SIP-T29G (FCC ID: T2C-T29G)
or the "EUT" in this report is an IP Phone, which was measured approximately: 226.5 cm (L) x 20.0 cm (W) x
13.0 cm (H), rated with input voltage: DC 5.0V from adapter. The highest operation frequency is 200 MHz.

Adapter 1 Information:
Model: NSA15EU-050200
Input: AC 100-240V~50/60Hz, 0.5A
Output: DC 5.0V, 2.0A

Adapter 2 Information:
Model: OH-1015A0502000U2-UL
Input: AC 100-240V~50/60Hz, 350mA
Output: DC 5.0V, 2A

* All measurement and test data in this report was gathered from production sample serial number:1408200
 (Assigned by the BACL, Shenzhen). The EUT supplied by the applicant was received on 2014-08-26.


Objective
This report is prepared on behalf of Yealink (Xiamen) Network Technology Co., Ltd. in accordance with
Part 2-Subpart J, and Part 15-Subparts A and B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15, Class B.

Related Submittal(s)/Grant(s)

No related submittal(s).


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2009, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Shenzhen). The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




FCC Part 15, Class B                                                                        Page 3 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ140826006-00

Test Facility
The test site used by Bay Area Compliance Laboratories Corp.(Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on December 06, 2010. The
facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2009.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 15, Class B                                                                         Page 4 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ140826006-00

SYSTEM TEST CONFIGURATION (FCC §15.27)

Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software

No exercise software was used.


Special Accessories

No special accessory was used.


Equipment Modifications

No modification was made to the EUT tested.


Support Equipment List and Details


          Manufacturer         Description            Model                  Serial Number

             Sagem                Router               N/A                         N/A
             Yealink             IP phone           SIP-T29G                       N/A
              BULL                Scoket            GN-415K                  5503290068073
              DELL                 PC                DCSCSF                     LE513565
              DELL               Monitor             E178FPc                     070072
              DELL               Keyboard            SK-8115          CN-0DJ313-71616-0CE-0ATX
            A4TECH                Mouse               D-300                        N/A
             ECOM                Modem               56000bps                   21654684
             LISTED          Modem Adapter       TYP60-1207000Z                  326703
             Sagem                Router               N/A                         N/A




FCC Part 15, Class B                                                                           Page 5 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00

External I/O Cable

                  Cable Description                    Length (m)             From / Port                  To

     1     Un-shielding un-detachable AC cable              1.0                 Mains                     Scoket
     2     Un-shielding un-detachable DC cable              1.8                  EUT                     Adapter
     3     Un-shielding detachable RJ45 cable               1.6                  EUT                       PC
     4     Shielding Un-detachable USB cable                1.5                   PC                      Mouse
     5     Shielding Un-detachable USB cable                1.5                   PC                     Keyboard
     6     Shielding detachable VGA cable                   1.5                Monitor                     PC
     7     Un-shielding detachable RS232 cable              1.8                  PC                      Modem
                                                                               Modem
     8     Un-shielding un-detachable DC cable              1.7                                          Modem
                                                                               Adapter
     9     Un-shielding un-detachable AC cable              1.5                 Mains                    Monitor
     10    Un-shielding detachable RJ45 cable               3.0                  EUT                      Router
     11    Un-shielding un-detachable AC cable              1.5                 Mains               Modem Adapter
     12    Un-shielding detachable AC cable                 1.5                 Mains                      PC
     13    Un-shielding detachable RJ45 cable               1.5                IP phone                   Router


Block Diagram of Test Setup
                                                                                                    12
                                             11
                               10                                                                    9
                           8                 7                                   3              2               1
                                                                6

                 Modem          Modem             Monitor            PC                EUT          Adapter                     Mains
                 Adapter
Router
                                                                                                    Socket

13
                                                                                                                    1.0 meter




IP Phone                                                    5             4




                  Non-Conductive Table
                  80 cm above Ground Plane
                                              Keyboard              Mouse

                                                       1.5 meters




FCC Part 15, Class B                                                                                            Page 6 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                    Report No.: RSZ140826006-00

SUMMARY OF TEST RESULTS


          FCC Rules                         Description of Test               Results

            §15.107                    AC Line Conducted Emissions          Compliance

            §15.109                         Radiated Emissions              Compliance




FCC Part 15, Class B                                                                Page 7 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ140826006-00

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Applicable Standard

According to FCC§15.107


Measurement Uncertainty

Input quantities to be considered for conducted disturbance measurements maybe receiver reading,
attenuation of the connection between LISN and receiver, LISN voltage division factor, A LISN VDF
frequency interpolation and receiver related input quantities, etc.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of conducted disturbance test
at Bay Area Compliance Laboratories Corp. (Shenzhen) is shown as below. And the uncertainty will not be
taken into consideration for the test data recorded in the report.

                          Port                             Measurement uncertainty
                       AC Mains                      3.26 dB (k=2, 95% level of confidence)
                         CAT 3                       3.70 dB (k=2, 95% level of confidence)
                         CAT 5                       3.86 dB (k=2, 95% level of confidence)
                         CAT 6                       4.64 dB (k=2, 95% level of confidence)



EUT Setup




FCC Part 15, Class B                                                                          Page 8 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ140826006-00

The measurement procedure of EUT setup is according with ANSI C63.4-2009. The related limit was
specified in FCC Part 15.107 Class B.

The socket was connected to an AC 120V/60 Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                Frequency Range                          IF B/W
                                150 kHz – 30 MHz                           9 kHz


Test Procedure
During the conducted emission test, the socket was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All final data was recorded in the Quasi-peak and average detection mode.


Test Equipment List and Details

                                                                                   Calibration    Calibration
     Manufacturer           Description           Model        Serial Number
                                                                                      Date         Due Date
   Rohde & Schwarz       EMI Test Receiver      ESCS30            100176           2014-06-03     2015-06-03
   Rohde & Schwarz            LISN              ESH3-Z5           100113              NCR            NCR
                                                              3560.6650.12-10
   Rohde & Schwarz             LISN              ENV216                            2014-06-09     2015-06-09
                                                                 1613-Yb
   Rohde & Schwarz       Transient Limiter       ESH3Z2          DE25985           2014-05-14     2015-05-14
   Rohde & Schwarz       CE Test software        EMC 32            V8.53                -              -

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
  been performed in accordance to requirements that traceable to National Primary Standards and International
  System of Units (SI).




FCC Part 15, Class B                                                                                 Page 9 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                       Report No.: RSZ140826006-00

Corrected Factor & Margin Calculation

The Corrected factor is calculated by adding LISN/ISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
     Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

       Margin = Limit – Corrected Amplitude


Test Results Summary
According to the recorded data in following table, the worst margin reading as below:

                      11.8 dB at 0.569510 MHz in the Neutral conducted mode for adapter 2

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if

                                               Lm + U(Lm ) ≤ Llim + Ucispr

In BACL., U(Lm ) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

              Temperature:                   25℃
         Relative Humidity:                  53 %
             ATM Pressure:                101.0 kPa

     The testing was performed by Webb Liu on 2014-09-02




FCC Part 15, Class B                                                                                       Page 10 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00


    EUT operation mode: Talking & Ping data with PC (for adapter 1)

       AC 120V/60 Hz, Line

                                                           EMI Auto Test L


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          2.891010                     38.4          19.6              56.0          17.6               QP
          2.891010                     28.9          19.6              46.0          17.1               Ave.
          2.898350                     38.2          19.6              56.0          17.8               QP
          2.898350                     28.9          19.6              46.0          17.1               Ave.
          2.961570                     38.6          19.7              56.0          17.4               QP
          2.961570                     29.0          19.7              46.0          17.0               Ave.
          2.972850                     38.6          19.7              56.0          17.4               QP
          2.972850                     29.0          19.7              46.0          17.0               Ave.
          2.985270                     38.5          19.7              56.0          17.5               QP
          2.985270                     28.8          19.7              46.0          17.2               Ave.
         27.462310                     17.1          20.1              60.0          42.9               QP
         27.462310                     11.2          20.1              50.0          38.8               Ave.




FCC Part 15, Class B                                                                                            Page 11 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00


     AC 120V/60 Hz, Neutral

                                                           EMI Auto Test N


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          0.529990                     36.8          19.6              56.0          19.2               QP
          0.529990                     29.3          19.6              46.0          16.7               Ave.
          2.645090                     36.0          19.7              56.0          20.0               QP
          2.645090                     28.3          19.7              46.0          17.7               Ave.
          2.863130                     41.0          19.7              56.0          15.0               QP
          2.863130                     32.6          19.7              46.0          13.4               Ave.
          3.020850                     41.3          19.7              56.0          14.7               QP
          3.020850                     32.8          19.7              46.0          13.2               Ave.
          3.348110                     38.8          19.7              56.0          17.2               QP
          3.348110                     29.6          19.7              46.0          16.4               Ave.
          3.603130                     38.1          19.7              56.0          17.9               QP
          3.603130                     28.5          19.7              46.0          17.5               Ave.




FCC Part 15, Class B                                                                                            Page 12 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00


    EUT operation mode: Talking & Ping data with PC (for adapter 2)

       AC 120V/60 Hz, Line

                                                           EMI Auto Test L


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          0.166501                     42.6          19.6              65.1          22.6               QP
          0.166501                     27.9          19.6              55.1          27.2               Ave.
          0.541990                     36.7          19.6              56.0          19.3               QP
          0.541990                     29.2          19.6              46.0          16.8               Ave.
          0.561630                     38.9          19.6              56.0          17.1               QP
          0.561630                     30.8          19.6              46.0          15.2               Ave.
         17.696590                     38.1          19.9              60.0          21.9               QP
         17.696590                     32.6          19.9              50.0          17.4               Ave.
         18.242510                     39.9          19.9              60.0          20.1               QP
         18.242510                     34.7          19.9              50.0          15.3               Ave.
         18.244370                     39.8          19.9              60.0          20.2               QP
         18.244370                     34.5          19.9              50.0          15.5               Ave.




FCC Part 15, Class B                                                                                            Page 13 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00


     AC 120V/60 Hz, Neutral

                                                           EMI Auto Test N


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          0.150000                     44.5          19.6              66.0          21.5               QP
          0.150000                     30.3          19.6              56.0          25.7               Ave.
          0.419670                     36.0          19.6              57.5          21.4               QP
          0.419670                     30.2          19.6              47.5          17.2               Ave.
          0.439430                     35.9          19.6              57.1          21.1               QP
          0.439430                     30.2          19.6              47.1          16.9               Ave.
          0.537950                     37.9          19.6              56.0          18.1               QP
          0.537950                     32.7          19.6              46.0          13.3               Ave.
          0.569510                     40.7          19.6              56.0          15.3               QP
          0.569510                     34.2          19.6              46.0          11.8               Ave.
          1.046130                     33.4          19.5              56.0          22.6               QP
          1.046130                     27.7          19.5              46.0          18.3               Ave.




FCC Part 15, Class B                                                                                            Page 14 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00

    EUT operation mode: Talking & Ping data with PC (for PoE)

       AC 120V/60 Hz, Line

                                                           EMI Auto Test L


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
         12.225530                     37.9          19.7              60.0          22.1               QP
         12.225530                     30.5          19.7              50.0          19.5               Ave.
         12.371030                     38.1          19.7              60.0          21.9               QP
         12.371030                     32.2          19.7              50.0          17.8               Ave.
         12.506410                     38.7          19.7              60.0          21.3               QP
         12.506410                     32.3          19.7              50.0          17.7               Ave.
         12.647290                     39.3          19.7              60.0          20.7               QP
         12.647290                     33.4          19.7              50.0          16.6               Ave.
         13.631570                     35.7          19.8              60.0          24.3               QP
         13.631570                     30.4          19.8              50.0          19.6               Ave.
         13.765470                     38.5          19.8              60.0          21.5               QP
         13.765470                     33.3          19.8              50.0          16.7               Ave.




FCC Part 15, Class B                                                                                            Page 15 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ140826006-00


     AC 120V/60 Hz, Neutral

                                                           EMI Auto Test N


                          90

                          80

                          70

                                                                                                               QP
                          60
                                                                                                               AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M          2M     3M    4M 5M 6      8 10M      20M     30M
                                                             Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit         Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)          (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          0.282500                     35.7          19.5              60.7          25.0               QP
          0.282500                     28.3          19.5              50.7          22.4               Ave.
          4.820710                     34.5          19.7              56.0          21.5               QP
          4.820710                     33.9          19.7              46.0          12.1               Ave.
          4.887690                     33.8          19.7              56.0          22.2               QP
          4.887690                     32.4          19.7              46.0          13.6               Ave.
         12.713630                     39.1          19.8              60.0          20.9               QP
         12.713630                     32.8          19.8              50.0          17.2               Ave.
         12.783330                     38.4          19.8              60.0          21.6               QP
         12.783330                     32.7          19.8              50.0          17.3               Ave.
         14.250330                     38.5          19.9              60.0          21.5               QP
         14.250330                     32.6          19.9              50.0          17.4               Ave.

     Note:
     1) Corrected Amplitude = Reading + Correction Factor
     2) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     3) Margin = Limit – Corrected Amplitude




FCC Part 15, Class B                                                                                            Page 16 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ140826006-00

FCC§15.109 - RADIATED EMISSIONS
Applicable Standard
FCC §15.109


Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay
Area Compliance Laboratories Corp. (Shenzhen) is shown in below table. And the uncertainty will not be
taken into consideration for the test data recorded in the report

            Frequency                         Polarity               Expanded Measurement uncertainty

                                             Horizontal             4.62 dB (k=2, 95% level of confidence)
         30MHz~200MHz
                                               Vertical             4.54 dB (k=2, 95% level of confidence)
                                             Horizontal             4.84 dB (k=2, 95% level of confidence)
         200MHz~1GHz
                                               Vertical             5.91 dB (k=2, 95% level of confidence)
          1 GHz~6 GHz                    Horizontal/Vertical        4.68 dB (k=2, 95% level of confidence)
          Above 6 GHz                    Horizontal/Vertical        4.92 dB (k=2, 95% level of confidence)


EUT Setup




FCC Part 15, Class B                                                                          Page 17 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                      Report No.: RSZ140826006-00

The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2009. The related limit was specified in FCC Part 15.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.


EMI Test Receiver Setup
According to FCC 15.33 requirements, the EUT system was measured from 30 MHz to 2 GHz.

During the radiated emission test, the EMI test receiver Setup was set with the following configurations:

                 Frequency Range               RBW          Video B/W             IF B/W           Detector
                30 MHz – 1000 MHz             100 kHz          300 kHz           120 kHz             QP
                                               1 MHz            3 MHz               -               Peak
                   Above 1 GHz
                                               1 MHz            10 Hz               -              Average


Test Procedure

During the radiated emission test, the socket was connected to the AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

All final data was recorded in the Quasi-peak detection mode for below 1 GHz, and Peak and Average for above
1 GHz.

Test Equipment List and Details

                                                                          Serial       Calibration       Calibration
     Manufacturer             Description               Model
                                                                         Number           Date            Due Date
          TDK                  Chamber               Chamber A              2#             2012-10-15     2015-10-15
          TDK                  Chamber               Chamber B              1#             2012-11-12     2015-11-12
           HP                  Amplifier             HP8447E         1937A01046            2015-05-06     2015-05-06
    Rohde & Schwarz        EMI Test Receiver            ESCI              101120           2013-11-12     2014-11-12
     Sunol Sciences       Broadband Antenna              JB1             A040904-2         2011-11-28     2014-11-27
    Rohde & Schwarz         Signal Analyzer             FSIQ26       8386001028            2013-11-12     2014-11-12
          Mini               Pre-Amplifier         ZVA-183-S+        5969001149            2014-04-03     2015-04-03
       A.H.System            Horn Antenna          SAS-200/571              135            2012-02-11     2015-02-10
          R&S             Auto test Software            EMC32              V9.10               -                  -

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
  been performed in accordance to requirements, traceable to National Primary Standards and International System
  of Units (SI).




FCC Part 15, Class B                                                                                          Page 18 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ140826006-00

Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude

Test Results Summary

According to the data in the following table, the EUT complied with the FCC §15.109, the worst margin
reading as below:

   3.30 dB at 600.001750 MHz in the 30 MHz~1 GHz Talking& Ping data with PC mode at Vertical
                                       polarization for PoE


Test Data
     Environmental Conditions

             Temperature:               25℃
        Relative Humidity:              55 %
            ATM Pressure:             101.0kPa

    The testing was performed by Webb Liu on 2014-09-03.




FCC Part 15, Class B                                                                       Page 19 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                          Report No.: RSZ140826006-00


For adapter 1

EUT operation mode: Talking & Ping data with PC

 30 MHz ~ 1000 MHz

                                                                 Full Spectrum



                          80



                          70



                          60
                                                                                 FCC Part 15 Class B Electric Field Strength QP
        Level in dBμV/m




                          50



                          40



                          30



                          20



                          10



                           0
                           30M       50    60     80     100M                200           300      400    500           800      1G
                                                                   Frequency in Hz



                                 Corrected      Antenna                      Turntable           Correction
     Frequency                                                  Antenna                                            Limit           Margin
                                 Amplitude       height                       position            Factor
       (MHz)                                                    Polarity                                         (dBμV/m)           (dB)
                                 (dBμV/m)         (cm)                         (deg)              (dB/m)
     30.618875                     29.23         102.0             V             248.0              -6.4            40.00              10.77
     32.589500                     30.09         109.0             V             200.0              -8.1            40.00              9.91
     58.716750                     31.46         109.0             V              83.0             -19.9            40.00              8.54
     66.313500                     30.76         100.0             V             118.0             -19.6            40.00              9.24
     599.989250                    41.58         162.0             H             132.0              -8.4            46.00              4.42
     699.974000                    38.31         119.0             H             189.0              -5.5            46.00              7.69




FCC Part 15, Class B                                                                                                              Page 20 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ140826006-00


   1 GHz ~ 2 GHz

                                                                  Correction   Corrected
 Frequency   Reading     Detector   Turntable   Height    Polar                              Limit  Margin
                                                                   Factor      Amplitude
   (MHz)     (dBμV)    (PK/QP/Ave.)  Degree      (m)      (H/V)                            (dBμV/m)  (dB)
                                                                   (dB/m)      (dBμV/m)

  1158.31     37.32        PK          124          1.2    H        -0.58        36.74       74         37.26
  1158.31     29.39        Ave         124          1.2    H        -0.58        28.81       54         25.19
  1505.01     35.07        PK           79          1.0    H        0.74         35.81       74         38.19
  1505.01     25.56        Ave         79           1.0    H        0.74         26.30       54         27.70
  1697.39     35.46        PK          103          1.8    H        1.77         37.23       74         36.77
  1697.39     24.65        Ave         103          1.8    H        1.77         26.42       54         27.58
  1344.67     38.63        PK           37          1.0    V        0.19         38.82       74         35.18
  1344.67     27.83        Ave         37           1.0    V        0.19         28.02       54         25.98
  1498.99     38.97        PK           81          1.2    V        0.74         39.71       74         34.29
  1498.99     27.28        Ave         81           1.2    V        0.74         28.02       54         25.98
  1959.92     38.56        PK          251          1.5    V        3.07         41.63       74         32.37
  1959.92     31.43        Ave         251          1.5    V        3.07         34.50       54         19.50




FCC Part 15, Class B                                                                              Page 21 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                           Report No.: RSZ140826006-00


For adapter 2

EUT operation mode: Talking & Ping data with PC

 30 MHz ~ 1000 MHz

                                                                   Full Spectrum



                            80



                            70



                            60
                                                                                   FCC Part 15 Class B Electric Field Strength QP

                            50
          Level in dBuV/m




                            40



                            30



                            20



                            10



                             0
                             30M         50    60      80   100M                200          300      400     500           800     1G
                                                                       Frequency in Hz




     Frequency                     Corrected    Antenna       Antenna        Turntable        Correction          Limit             Margin
       (MHz)                       Amplitude     height       Polarity        position         Factor           (dBμV/m)             (dB)
                                   (dBμV/m)       (cm)                         (deg)           (dB/m)
     32.892500                       28.67       100.0             V           223.0             -8.4               40.00           11.33
     50.438750                       29.54          113.0          V            37.0               -19.7            40.00           10.46
     51.073750                       26.41          109.0          V           147.0               -19.9            40.00           13.59
     274.747500                      28.44          127.0          H           337.0               -12.8            46.00           17.56
     600.001750                      42.70          105.0          V           277.0               -8.4             46.00            3.30
     700.033625                      39.86          123.0          H           216.0               -5.5             46.00            6.14




FCC Part 15, Class B                                                                                                              Page 22 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ140826006-00


   1 GHz ~ 2 GHz

                                                                  Correction   Corrected
 Frequency   Reading     Detector   Turntable   Height    Polar                              Limit  Margin
                                                                   Factor      Amplitude
   (MHz)     (dBμV)    (PK/QP/Ave.)  Degree      (m)      (H/V)                            (dBμV/m)  (dB)
                                                                   (dB/m)      (dBμV/m)

  1164.33     39.87        PK          124          1.0    H        -0.58        39.29       74         30.71
  1164.33     29.28        Ave         124          1.0    H        -0.58        28.70       54         21.30
  1523.04     35.35        PK          309          1.5    H        1.15         36.50       74         33.50
  1523.04     26.35        Ave         309          1.5    H        1.15         27.50       54         22.50
  1754.43     35.73        PK          112          1.6    H        2.24         37.97       74         32.03
  1754.43     25.46        Ave         112          1.6    H        2.24         27.70       54         22.30
  1168.34     39.11        PK          122          1.0    V        -0.58        38.53       74         31.47
  1168.34     27.14        Ave         122          1.0    V        -0.58        26.56       54         23.44
  1332.67     41.26        PK           46          1.0    V        0.19         41.45       74         28.55
  1332.67     28.34        Ave         46           1.0    V        0.19         28.53       54         21.47
  1501.00     39.87        PK          298          1.2    V        0.74         40.61       74         29.39
  1501.00     25.92        Ave         298          1.2    V        0.74         26.66       54         23.34




FCC Part 15, Class B                                                                              Page 23 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                           Report No.: RSZ140826006-00

For PoE

EUT operation mode: Talking& Ping data with PC

 30 MHz ~ 1000 MHz

                                                                   Full Spectrum



                            80



                            70



                            60
                                                                                   FCC Part 15 Class B Electric Field Strength QP

                            50
          Level in dBuV/m




                            40



                            30



                            20



                            10



                             0
                             30M         50    60      80   100M                200          300      400     500           800     1G
                                                                       Frequency in Hz




     Frequency                     Corrected    Antenna       Antenna        Turntable        Correction          Limit             Margin
       (MHz)                       Amplitude     height       Polarity        position         Factor           (dBμV/m)             (dB)
                                   (dBμV/m)       (cm)                         (deg)           (dB/m)
     33.486500                       32.08        97.0             V           320.0             -8.9               40.00            7.92
     36.150000                       32.25          97.0           V           288.0               -10.9            40.00            7.75
     51.762750                       30.10          97.0           V           136.0               -20.1            40.00            9.90
     58.732625                       33.00          137.0          V               0.0             -19.9            40.00            7.00
     64.791000                       30.83          166.0          V           349.0               -19.8            40.00            9.17
     600.026500                      40.91          109.0          V            96.0               -8.4             46.00            5.09




FCC Part 15, Class B                                                                                                              Page 24 of 25


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ140826006-00


   1 GHz ~ 2 GHz

                                                                      Correction   Corrected
 Frequency    Reading     Detector   Turntable    Height    Polar                                Limit  Margin
                                                                       Factor      Amplitude
   (MHz)      (dBμV)    (PK/QP/Ave.)  Degree       (m)      (H/V)                              (dBμV/m)  (dB)
                                                                       (dB/m)      (dBμV/m)

  1166.33      41.26         PK          134        1.2      H          -0.58        40.68       74         33.32
  1166.33      38.08        Ave          134        1.2      H          -0.58        37.50       54         16.50
  1374.75      43.85        PK            83        1.5      H          0.19         44.04       74         29.96
  1374.75      33.03        Ave           83        1.5      H          0.19         33.22       54         20.78
  1951.90      45.52        PK           101        1.3      H          2.63         48.15       74         25.85
  1951.90      36.24        Ave          101        1.3      H          2.63         38.87       54         15.13
  1166.33      39.16         PK          156        1.1      V          -0.58        38.58       74         35.42
  1166.33      33.26        Ave           57        1.0      V          -0.58        32.68       54         21.32
  1374.75      39.60        PK            83        1.1      V          0.19         39.79       74         34.21
  1374.75      31.26        Ave          289        1.0      V          0.19         31.45       54         22.55
  1601.20      38.58        PK           247        1.1      V          1.70         40.28       74         33.72
  1601.20      30.06        Ave           97        1.1      V          1.70         31.76       54         22.24


Note:
1) Correction Factor = Antenna Factor + Cable Loss - Amplifier Gain
2) Corrected Amplitude = Meter Reading + Correction Factor
3) Margin = Limit – Corrected Amplitude




                                       ****END OF REPORT****




FCC Part 15, Class B                                                                                  Page 25 of 25



Document Created: 2014-09-29 17:36:37
Document Modified: 2014-09-29 17:36:37

© 2024 FCC.report