RF Exposure report

FCC ID: T2C-CP900

RF Exposure Info

Download: PDF
FCCID_4239210

                    Test Report No.: FM190201N013


                                   RF EXPOSURE REPORT
   Applicant                       YEALINK(XIAMEN) NETWORK TECHNOLOGY CO.,LTD.

                                   309, 3rd Floor, No.16, Yun Ding North Road, Huli District, Xiamen City, Fujian, P.R.
   Address
                                   China


   Manufacturer or
                                   YEALINK(XIAMEN) NETWORK TECHNOLOGY CO.,LTD.
   Supplier
                                   309, 3rd Floor, No.16, Yun Ding North Road, Huli District, Xiamen City, Fujian, P.R.
   Address
                                   China

   Product                         USB Speakerphone

   Brand Name                      YEALINK

   Model                           CP900

   Additional Model &
                                   N/A
   Model Difference

   Date of tests                   Feb. 01, 2019 ~ Mar. 01, 2019

        FCC Part 2 (Section 2.1091)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Tom Chen                                                            Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                           Date: Mar. 26, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 6                                                             Report Version 1


                Test Report No.: FM190201N013

                                    TABLE OF CONTENTS
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FM190201N013


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FM190201N013             Original release                                                         Mar. 26, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FM190201N013

   1. CERTIFICATION



                        FCC ID:     T2C-CP900

                   PRODUCT:         USB Speakerphone

              BRAND NAME:           YEALINK

                 MODEL NO.:         CP900

         ADDITIONAL NO.:            N/A

                                    YEALINK(XIAMEN) NETWORK TECHNOLOGY
                 APPLICANT:
                                    CO.,LTD.

               STANDARDS:           FCC Part 2 (Section 2.1091)

                                    KDB 447498 D01

                                    IEEE C95.1




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 6                                                    Report Version 1


                Test Report No.: FM190201N013

   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm2)                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


    B U R E A U
    V E R I TA S
                   Test Report No.: FM190201N013


   5. ANTENNA GAIN

         The antennas provided to the EUT, please refer to the following table:
                   Transmitter                                                            Antenna
                       .   I.                   Peak Gain (dBi)
                     Circuit                                                                  Type
                     Chain 0                                3                           PCB Antenna



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED AV POWER
   The tuned conducted Average Power (declared by client)

                                Frequenc             logs                Tolerance               e                     e
         Mode                     (|3|HZ) Y          Power                 (dBm)               Tolerance             Tolerance
                                                     (dBm)                                       (dBm})                (dBm})
        GFSK                2402—2480                   1                    +—1                     0                     2
       8DPSK                2402—2480                  —1                    +—1                     —2                    0


   The measured conducted Average Power

                                                       Frequency                                 Averaged Power
                   Mods                                     (MHz)                                         (dBm)
                   GFSK                                     2402                                          1.67
                   8DPSK                                    2402                                          —0.62



      FREQUENCY             |MAX AVERAGE|            ANTENNA                                          POWER
        BAND                   POWER                   GAIN                  DIS(-:;fnl;lCE          DENSITY               (mI;I:II\/’I;-rI;nz)
         (MHz)                  (dBm)                  (dBi)                                         (mW/cm*)

        2402—2480                      2                        3                  20                0.000629                     1.0




    ——— END ———




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie      Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                            Email: customerservice.dg@cn.bureauveritas.com

                                                                    Page 6 of 6                                                    Report Version 1



Document Created: 2019-04-15 09:04:45
Document Modified: 2019-04-15 09:04:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC