RF Exposure Info

FCC ID: SZGGPU999

RF Exposure Info

Download: PDF
FCCID_4372882

                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch

                                                                               Report No.: HR/2018/A001502
                                                                               Page:       1 of 7

                        Cover P   RF Exposure Evaluation Report
Application No.:                   HR/2018/A0015
Applicant:                         Weifang GoerTek Electronics Co., Ltd
Address of Applicant:              Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
Manufacturer:                      Weifang GoerTek Electronics Co., Ltd
Address of Manufacturer:           Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
Factory:                           Weifang GoerTek Electronics Co., Ltd
Address of Factory:                Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
EUT Description:                   Privacy Vision
Model No.:                         GP-U999GTEEA
Trade Mark:                        Smart Things
FCC ID:                            SZGGPU999
Standards:                         47 CFR Part 1.1307
                                   47 CFR Part 2.1093
                                   KDB447498D01 General RF Exposure Guidance v06
Date of Receipt:                   2018/11/10
Date of Test:                      2018/11/11to 2018/11/20
Date of Issue:                     2019/7/22
Test Result:                        PASS*
*   In the configuration tested, the EUT complied with the standards specified above.


               SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
               Branch
                                                            Report No.: HR/2018/A001502
                                                            Page:       2 of 7

1 Version
                                        Revision Record
      Version        Chapter         Date                  Modifier       Remark

          00                         2019/7/22                              Original




 Authorized for issue by:




                                                                      2019/7/22


                               Mike Hu /Project Engineer


                                                                      2019/7/22


                               David Chen /Reviewer


                         SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                         Branch
                                                                                                                Report No.: HR/2018/A001502
                                                                                                                Page:       3 of 7


                                                                            Contents
1       VERSION ................................................................................................................................................................. 2

2       GENERAL INFORMATION .................................................................................................................................. 4
    2.1          CLIENT INFORMATION ..................................................................................................................................... 4
    2.2          TEST LOCATION .............................................................................................................................................. 4
    2.3          TEST FACILITY ................................................................................................................................................. 4
    2.4          GENERAL DESCRIPTION OF EUT.................................................................................................................... 5
3       RF EXPOSURE EVALUATION ........................................................................................................................... 6
    3.1     RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................. 6
       3.1.1 Limits .......................................................................................................................................................... 6
       3.1.2 Test Procedure ......................................................................................................................................... 6
       3.1.3 EUT RF Exposure Evaluation ................................................................................................................ 7


                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch
                                                                  Report No.: HR/2018/A001502
                                                                  Page:       4 of 7


2      General Information
2.1 Client Information
Applicant:                 Weifang GoerTek Electronics Co., Ltd
Address of Applicant:      Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
Manufacturer:              Weifang GoerTek Electronics Co., Ltd
Address of Manufacturer:   Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
Factory:                   Weifang GoerTek Electronics Co., Ltd
Address of Factory:        Gaoxin 2 Road,Free Trade Zone, Weifang,Shandong,261205,P.R.China
2.2 Test Location
Company:                   SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
                           No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen,
Address:
                           Guangdong, China
Post code:                 518057
Telephone:                 +86 (0) 755 2601 2053
Fax:                       +86 (0) 755 2671 0594
E-mail:                    ee.shenzhen@sgs.com

2.3 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
• CNAS (No. CNAS L2929)
CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC Lab to
ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
(CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the
competence in the field of testing.
• A2LA (Certificate No. 3816.01)
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
• VCCI
The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded
Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted
Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in
accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188,
C-12383 and T-11153 respectively.
• FCC –Designation Number: CN1178
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an
accredited testing laboratory.
Designation Number: CN1178. Test Firm Registration Number: 406779.
• Industry Canada (IC)
Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards Technical
Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and Engineering
Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1, 4620C-2, 4620C-3.


                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch
                                                Report No.: HR/2018/A001502
                                                Page:       5 of 7




2.4 General Description of EUT
EUT Description::            Privacy Vision
Model No.:                   GP-U999GTEEA
Trade Mark:                  Smart Things
Hardware Version:            R4
Software Version:            V0.8
Antenna Gain:                WiFi:-2.5dBi;


                  SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                  Branch
                                                                   Report No.: HR/2018/A001502
                                                                   Page:       6 of 7



 3 RF Exposure Evaluation
3.1 RF Exposure Compliance Requirement
3.1.1 Limits
   Frequency range       Electric field strength Magnetic field strength Power density Averaging time
        (MHz)                     (V/m)                  (A/m)             (mW/cm2)      (minutes)
                           (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                   614                     1.63               *(100)             6
         3.0-30                  1842/f                   4.89/f             *(900/f2)           6
         30-300                   61.4                    0.163                 1.0              6
       300-1500                     /                       /                  f/300             6
     1500-100,000                   /                       /                    5               6
                       (B) Limits for General Population/Uncontrolled Exposure
        0.3-1.34                   614                     1.63               *(100)             30
        1.34-30                   824/f                   2.19/f             *(180/f2)           30
         30-300                   27.5                    0.073                 0.2              30
       300-1500                     /                       /                 f/1500             30
     1500-100,000                   /                       /                   1.0              30
F=frequency in MHz
*=Plane-wave equivalent power density
RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules. The
emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
150kHz:614V/m,1.63A/m).

Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.
3.1.2 Test Procedure
Software provided by client enabled the EUT to transmit data at lowest, middle and highest channel
individually.


                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch
                                                                                  Report No.: HR/2018/A001502
                                                                                  Page:       7 of 7




3.1.3 EUT RF Exposure Evaluation
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 / 2.0 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
                                      Max
                                              Output                              Power
                                   Conducted                         Output
                Frequenc Antenna              Power    EIRP(ERP)                  Density
    Operating                       Average                           Power                  Limit
                    y     Gain                  to        Limit                  at R = 20          conclusion
      Band                           Output                        to Antenna              (mW/cm2)
                  (MHz)   (dBi)              Antenna     (dBm)                      cm
                                     Power                            (mw)
                                              (dBm)                             (mW/cm2)
                                     (dBm)
    2.4G WiFi    2412     -2.50      17.00    14.50      20.97      50.1187      0.0056    1.0000      Pass




Remark: Refer to report No. ZR/2019/4003501 for EUT test Max Conducted Output Power value.



Document Created: 2019-07-24 14:39:24
Document Modified: 2019-07-24 14:39:24

© 2024 FCC.report