           CERPASS TECHNOLOGY CORP.                              Report No.: SEFD1605172




                            FCC TEST REPORT
                                            According to

                            47 CFR, Part 2, Part 15B, CISPR PUB. 22


                Applicant        : Weifang GoerTek Electronic Co.,LTD
                                   Gaoxin 2 Road,Free Trade Zone,Weifang,
                Address          :
                                   Shandong,261205,P.R.China
                                   Wireless Stereo Headset
                Equipment        :
                                   Wireless Adaptor
                                   CECHYA-0090;
                Model No.        :
                                   CECHYA-0091
                Brand name       : Sony Interactive Entertainment America LLC
                                     SZGCECHYA0090 (Headset)
                FCC ID           :
                                     SZGCECHYA0091 (Adaptor)

           I HEREBY CERTIFY THAT :
           The sample was received on Jul 12, 2016 and the testing was carried out on Jul
           21, 2016 at Cerpass Technology Corp. The test result refers exclusively to the test
           presented test model / sample. Without written approval of Cerpass Technology
           Corp., the test report shall not be reproduced except in full.

            Approved by:




            Ray Chou
            EMC/RF B.U. Assistant Manager




Cerpass Technology Corp.                                                     Issued Date : Aug 01, 2016
Report format Revision 01                                                    Page No.    : 1 of 30


           CERPASS TECHNOLOGY CORP.                                 Report No.: SEFD1605172




                            FCC TEST REPORT
                                                  Issued by:




                                        Cerpass Technology Co.,Ltd

         No.10, Lane 2, Lianfu Street, Luzhu Township, Taoyuan County 33848, Taiwan(R.O.C.)

                                             Tel: 886-3-322-6888

                                            Fax: 886-3-322-6881

   The test record, data evaluation & Equipment. Under Test configurations represented herein
   are true and accurate accounts of the measurements of the samples EMC characteristics
   under the conditions specified in this report.



            Laboratory Accreditation:

                   Cerpass Technology Corporation Test Laboratory

                        NVLAP LAB Code:            200954-0
                         TAF LAB Code:               1439




Cerpass Technology Corp.                                                       Issued Date : Aug 01, 2016
Report format Revision 01                                                      Page No.    : 2 of 30


              CERPASS TECHNOLOGY CORP.                                                                 Report No.: SEFD1605172



                                                                           Contents

   1. Summary of Test Procedure and Test Result........................................................................................... 5
          1.1.     Applicable Standards ....................................................................................................................... 5
   2. Test Configuration of Equipment under Test ........................................................................................... 6
          2.1.     Feature of Equipment under Test..................................................................................................... 6
          2.2.     Test Manner ..................................................................................................................................... 7
          2.3.     Description of Support Unit .............................................................................................................. 7
          2.4.     Connection Diagram of Test System................................................................................................ 8
          2.5.     General Information of Test............................................................................................................ 11
          2.6.     Measurement Uncertainty .............................................................................................................. 11
   3. Test of Conducted Emission.................................................................................................................... 12
          3.1.     Test Limit ........................................................................................................................................ 12
          3.2.     Test Procedures ............................................................................................................................. 12
          3.3.     Typical test Setup........................................................................................................................... 13
          3.4.     Measurement Equipment ............................................................................................................... 13
          3.5.     Test Result and Data...................................................................................................................... 14
   4. Test of Radiated Emission ....................................................................................................................... 15
          4.1.     Test Limit ........................................................................................................................................ 15
          4.2.     Test Procedures ............................................................................................................................. 16
          4.3.     Typical test Setup........................................................................................................................... 17
          4.4.     Measurement Equipment ............................................................................................................... 18
          4.5.     Test Result and Data (30MHz~1GHz)............................................................................................ 19
          4.6.     Test Result and Data (1GHz ~ 18GHz).......................................................................................... 25




Cerpass Technology Corp.                                                                                                      Issued Date : Aug 01, 2016
Report format Revision 01                                                                                                     Page No.            : 3 of 30


           CERPASS TECHNOLOGY CORP.                              Report No.: SEFD1605172

                                        History of this test report

            ORIGINAL.
            Additional attachment as following record:
           Report No          Version      Date           Description

           SEFD1605172        Rev 01       Aug 01, 2016   Initial Issue




Cerpass Technology Corp.                                                    Issued Date : Aug 01, 2016
Report format Revision 01                                                   Page No.    : 4 of 30


           CERPASS TECHNOLOGY CORP.                            Report No.: SEFD1605172

   1. Summary of Test Procedure and Test Result
     1.1. Applicable Standards
      The measurements shown in this test report were made in accordance with the procedures given in
      ANSI C63.4 – 2014 and the energy emitted by this equipment was passed Part 2, Part 15, CISPR
      PUB. 22.
      The energy emitted by this equipment was passed both Radiated and Conducted Emissions
      Class B limits.


                 Test Item          Normative References        Test Result              Remarks
                                       ANSI C63.4-2014
          Conducted Emission                                       N/A                     N/A
                                    FCC Part 15 Subpart B
                                                                                  Meets Class B Limit
                                       ANSI C63.4-2014                             Minimum passing
           Radiated Emission                                      PASS
                                    FCC Part 15 Subpart B                     margin(Peak) is-12.63dB at
                                                                                    947.6200MHz




Cerpass Technology Corp.                                                      Issued Date : Aug 01, 2016
Report format Revision 01                                                     Page No.     : 5 of 30


           CERPASS TECHNOLOGY CORP.                               Report No.: SEFD1605172


2. Test Configuration of Equipment under Test
   2.1. Feature of Equipment under Test
          Wireless Stereo Headset                          CECHYA-0090;
                                       Model No.:
          Wireless Adaptor                                 CECHYA-0091
          U+Dongle                     Model No.:          PVT1-1.0-219
          Audio Cable                  Non-Shielded,1.2m
          USB Cable                    Shielded, 0.7m, with one ferrites core bonded
         Note: Please refer to user manual.


         Model Discrepancy:
                                                           Discrepancy

          Equipment            Wireless Stereo Headset              Wireless Adaptor

          Model No.            CECHYA-0090                          CECHYA-0091




Cerpass Technology Corp.                                                        Issued Date : Aug 01, 2016
Report format Revision 01                                                       Page No.    : 6 of 30


           CERPASS TECHNOLOGY CORP.                                  Report No.: SEFD1605172


   2.2. Test Manner
         a.     During testing, the interface cables and equipment positions were varied according to ANSI
                C63.4.
         b.     The complete test system included Notebook PC and EUT for EMI test.
         c.     During the test, setup up the EUT and all system, turn on the power of all Equipments.
         d.     Make the EUT at the test mode and it is normal operation, and then test.
          The pre-test modes :
               Mode 1:   Charging Mode(From Computer)
               Mode 2:   Normal Communication Mode(By Audio cable)
               Mode 3:   Wierless Communication Mode(By U+Dongle)
          The final modes :
               Mode 1:   Charging Mode(From Computer)
               Mode 2:   Normal Communication Mode(By Audio cable)
               Mode 3:   Wierless Communication Mode(By U+Dongle)




   2.3. Description of Support Unit
           No.     Device            Manufacturer    Model No.              Description
           1       Notebook PC       DELL            Vostro 3560            R31199




Cerpass Technology Corp.                                                           Issued Date : Aug 01, 2016
Report format Revision 01                                                          Page No.    : 7 of 30


            CERPASS TECHNOLOGY CORP.                     Report No.: SEFD1605172

  2.4. Connection Diagram of Test System

   Mode 1




        No.      Cable         Quantity    Description
        A        USB Cable        1        Shielded, 0.7m with one ferrites core bonded




Cerpass Technology Corp.                                             Issued Date : Aug 01, 2016
Report format Revision 01                                            Page No.    : 8 of 30


            CERPASS TECHNOLOGY CORP.                    Report No.: SEFD1605172

   Mode 2




        No.      Cable         Quantity   Description
        A        Audio Cable      1       Non-Shielded, 1.2m




Cerpass Technology Corp.                                           Issued Date : Aug 01, 2016
Report format Revision 01                                          Page No.    : 9 of 30


            CERPASS TECHNOLOGY CORP.                   Report No.: SEFD1605172

   Mode 3




        No.      Cable        Quantity   Description
        N/A      N/A            N/A      N/A




Cerpass Technology Corp.                                          Issued Date : Aug 01, 2016
Report format Revision 01                                         Page No.    : 10 of 30


           CERPASS TECHNOLOGY CORP.                                Report No.: SEFD1605172


 2.5. General Information of Test

           Test Site :                      Cerpass Technology Corporation Test Laboratory
                                            Address: No.10, Ln. 2, Lianfu St., Luzhu Dist., Taoyuan City
                                            33848, Taiwan (R.O.C.)
                                            Tel:+886-3-3226-888
                                            Fax:+886-3-3226-881
                                            Address: No.68-1, Shihbachongsi, Shihding Township,
                                            New Taipei City 223, Taiwan, R.O.C.
                                            Tel: +886-2-2663-8582
           FCC Registration Number :        TW1079, TW1061,390316, 228391, 641184

           IC Registration Number :         4934B-1, 4934E-1, 4934E-2

                                            T-2205 for Telecommunication Test
                                            C-4663 for Conducted emission test
           VCCI
                                            R-3428, R-4218 for Radiated emission test
                                            G-812, G-813 for radiated disturbance above 1GHz
           Frequency Range                  Conducted Emission Test: from 150 kHz to 30 MHz
           Investigated :                   Radiated Emission Test: from 30 MHz to 18,000 MHz
                                            The test distance of radiated emission below 1GHz from
                                            antenna to EUT is 3 M.
           Test Distance :
                                            The test distance of radiated emission above 1GHz from
                                            antenna to EUT is 3 M.




 2.6. Measurement Uncertainty

           Measurement Item           Measurement Frequency      Polarization            Uncertainty
           Conducted Emission         9 kHz ~ 30 MHz             LINE / NEUTRAL          3.25 dB
                                      30 MHz ~ 1,000 MHz         Vertical / Horizontal   3.93 dB
           Radiated Emission
                                      1,000 MHz ~ 18,000 MHz     Vertical / Horizontal   5.18 dB
        The measurement uncertainty will be considered, when test result margin to the limit.




Cerpass Technology Corp.                                                          Issued Date : Aug 01, 2016
Report format Revision 01                                                         Page No.      : 11 of 30


           CERPASS TECHNOLOGY CORP.                                   Report No.: SEFD1605172


3. Test of Conducted Emission

   3.1. Test Limit
         Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz
         on the 120 VAC power and return leads of the EUT according to the methods defined in
         ANSI C63.4-2009 Section 3.1. The EUT was placed on a nonmetallic stand in a shielded
         room 0.8 meters above the ground plane as shown in section 2.2. The interface cables
         and equipment positioning were varied within limits of reasonable applications to determine
         the position produced maximum conducted emissions.

         Conducted Emission Limits:
                  Frequency               Quasi Peak                  Average
                    (MHz)                  (dB µ V)                   (dB µ V)
                  0.15 – 0.5                66-56*                     56-46*
                   0.5 – 5.0                  56                         46
                  5.0 – 30.0                  60                         50


   3.2. Test Procedures
         a. The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept at
             least 80 centimeters from any other grounded conducting surface.
         b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
         c. All the support units are connecting to the other LISN.
         d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
         e. The FCC states that a 50 ohm, 50 micro-Henry LISN should be used.
         f. Both sides of AC line were checked for maximum conducted interference.
         g. The frequency range from 150 kHz to 30 MHz was searched.
         h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum
             Hold Mode.




Cerpass Technology Corp.                                                         Issued Date : Aug 01, 2016
Report format Revision 01                                                        Page No.    : 12 of 30


           CERPASS TECHNOLOGY CORP.                                    Report No.: SEFD1605172

     3.3. Typical test Setup


                                              10cm




                             EUT



                                                                                   80cm

                      80cm


                                     80cm


                                                                40cm
               LISN                                                                LISN

                                                         40cm




     3.4. Measurement Equipment
                                                                                   Calibration
        Instrument/Ancillary Manufacturer        Model No.         Serial No.                        Valid Date.
                                                                                      Date
           Test Receiver            R&S              ESCI              100565      2016.03.26        2017.03.25
                AMN                 R&S          ESH2-Z5               100182      2015.09.06        2016.09.05
        Two-Line V-Network          R&S           ENV216               100325             /                   /
                 ISN                FCC       FCC-TLISN-T2-02          20379       2016.03.26        2017.03.25
                 ISN                FCC       FCC-TLISN-T4-02          20380       2016.03.26        2017.03.25
                 ISN                FCC       FCC-TLISN-T8-02          20381       2016.03.26        2017.03.25
                 ISN               TESEQ         ISN ST08              30175       2016.03.26        2017.03.25
           Current Probe            R&S              EZ-17             100303      2016.03.26        2017.03.25
      Passive Voltage Probe         R&S          ESH2-Z3               100026      2016.03.26        2017.03.25
            Pulse Limiter           R&S          ESH3-Z2               100529      2016.03.26        2017.03.25
      Temperature/ Humidity
                                   Zhicheng          ZC1-11       CEP-TH-004       2016.03.29        2017.03.28
             Meter
              EZ-EMC                 Fala       Ver CT3A1               N/A           N/A                 N/A




Cerpass Technology Corp.                                                          Issued Date : Aug 01, 2016
Report format Revision 01                                                         Page No.       : 13 of 30


           CERPASS TECHNOLOGY CORP.                                 Report No.: SEFD1605172

     3.5. Test Result and Data
           For this product is supplied by DC source, this test item needn't perform.




Cerpass Technology Corp.                                                          Issued Date : Aug 01, 2016
Report format Revision 01                                                         Page No.    : 14 of 30


           CERPASS TECHNOLOGY CORP.                                Report No.: SEFD1605172


4. Test of Radiated Emission
     4.1. Test Limit
   Below 1GHz (for digital device)

   For unintentional device, according to CISPR PUB.22, for Class B digital devices, the general requirement
   of field strength of radiated emissions from intentional radiators at a distance of 10 meters shall not
   exceed the below table.

                                                                  dBuV/m (At 10m)
             FREQUENCY (MHz)
                                                       Class A                         Class B
                   30 ~ 230                              40                              30
                  230 ~ 1000                             47                              37
   Limit tables for non-digital device:
   Class A Radiated Emission limit at 10m (for others)
          Frequency                  Field Strength Limit                   Field Strength Limit
            (MHZ)                         (uV/m)Q.P.                           (dBuV/m)Q.P.
            30 - 88                           90                                     39
           88 - 216                           150                                   43.5
          216 – 960                           210                                   46.4
          Above 960                           300                                   49.5

   Class B Radiated Emission limit at 3m (for others)
          Frequency                  Field Strength Limit                   Field Strength Limit
            (MHZ)                         (uV/m)Q.P.                           (dBuV/m)Q.P.
            30 - 88                           100                                    40
           88 - 216                           150                                   43.5
          216 – 960                           200                                    46
          Above 960                           500                                    54

   Above 1GHz(for all device)
                                 Class A (dBuV/m) (At 10m)               Class B (dBuV/m) (At 3m)
          Frequency
            (MHZ)
                                 Average              Peak              Average                Peak

          Above 1000                49.5               69.5                54                   74

   NOTE: (1) The lower limit shall apply at the transition frequencies.
         (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).
        (3) The measurement above 1GHz is at close-in distances 3m,and determine the limit L2
            corresponding to the close-in distance d2 by applying the following relation: L2 = L1 (d1/d2),
            where L1 is the specified limit in microvolts per metre (uV/m) at the distance d1 (10m), L2 is
            the new limit for distance d2 (3m).
            So the new Class A limit above 1GHz at 3m is as following table:




Cerpass Technology Corp.                                                          Issued Date : Aug 01, 2016
Report format Revision 01                                                         Page No.    : 15 of 30


            CERPASS TECHNOLOGY CORP.                                Report No.: SEFD1605172

                                                                   Class A (dBuV/m) (At 3m)
                       Frequency
                         (MHZ)
                                                                 Average                       Peak

                       Above 1000                                    60                          80
   According to FCC Part 15.33 (b), for an unintentional radiator, including a digital device, the spectrum
   shall be investigated from the lowest radio frequency signal generated or used in the device, without
   going below the lowest frequency for which a radiated emission limit is specified, up to the frequency
   shown in the following table:
     Highest frequency generated or used in the
                                                             Upper frequency of measurement range
   device or on which the device operates or tunes
                                                                                (MHz)
                              (MHz)
                            Below 1.75                                           30
                             1.75-108                                           1000
                             108-500                                            2000
                            500-1000                                            5000
                                                          5th harmonic of the highest frequency or 40GHz,
                        Above 1000
                                                                          whichever is lower


     4.2. Test Procedures

   Procedure of Preliminary Test

            The equipment was set up as per the test configuration to simulate typical usage per the user’s
             manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is
             used which is placed on the ground plane. When the EUT is a floor standing equipment, it is
             placed on the ground plane which has a 15 cm non-conductive covering to insulate the EUT
             from the ground plane.
            Support equipment, if needed, was placed as per ANSI C63.4.
            All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
            The EUT received AC 120VAC/60Hz power source from the outlet socket under the turntable.
             All support equipment power received from another socket under the turntable.
            The antenna was placed at 3 or 10 meter away from the EUT as stated in ANSI C63.4. The
             antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be
             used.
            The Analyzer / Receiver quickly scanned from 30MHz to 40GHz. The EUT test program was
             started. Emissions were scanned and measured rotating the EUT to 360 degrees and
             positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the
             horizontal polarization, to maximize the emission reading level.


Cerpass Technology Corp.                                                           Issued Date : Aug 01, 2016
Report format Revision 01                                                          Page No.    : 16 of 30


            CERPASS TECHNOLOGY CORP.                                 Report No.: SEFD1605172

            Set the spectrum analyzer/ Receiver in the following setting as:
             Below 1GHz:
             RBW=120KHz / VBW=300KHz / Sweep=AUTO
             Above 1GHz:
             Peak: RBW=1MHz, VBW=3MHz / Sweep=AUTO
             Average: RBW=1MHz / VBW=1Hz / Sweep=AUTO
            The worst configuration of EUT and cable of the above highest emission level were recorded
             for reference of the final test.

   Procedure of Final Test

            EUT and support equipment were set up on the turntable as per the configuration with highest
             emission level in the preliminary test.
            The Analyzer / Receiver scanned from 30MHz to 40GHz. Emissions were scanned and
             measured rotating the EUT to 360 degrees, varying cable placement and positioning the
             antenna 1 or 1 to 4 meters above the ground plane, in both the vertical and the horizontal
             polarization, to maximize the emission reading level.
            Recording at least the six highest emissions. Emission frequency, amplitude, antenna position,
             polarization and turntable position were recorded into a computer in which correction factors
             were used to calculate the emission level and compare reading to the applicable limit. Below
             1GHz the Q.P. reading and above 1GHz the Peak and Average reading are presented.
            The test data of the worst-case condition(s) was recorded.




     4.3. Typical test Setup
            Below 1GHz Test Setup
                                   Antenna


                                                                             Equipment under Test




                                                *      3m

                                                                                                    0.8M
                                                                                     Turn




                                                              Ground Plane
            Receiver




Cerpass Technology Corp.                                                              Issued Date : Aug 01, 2016
Report format Revision 01                                                             Page No.      : 17 of 30


           CERPASS TECHNOLOGY CORP.                         Report No.: SEFD1605172

          Above 1GHz Test Setup




     4.4. Measurement Equipment
                                                                      Calibration
    Instrument/Ancillary    Manufacturer    Model No.    Serial No.                  Valid Date.
                                                                         Date
     EMI Test Receiver          R&S           ESCI        101183      2016.03.26     2017.03.25
         Preamplifier          songyi        EM330        60618       2016.03.26     2017.03.25
         Preamplifier          Agilent        8449B     3008A02342 2016.03.26        2017.03.25
        Bilog Antenna       Sunol Science      JB1      A072414-1     2016.04.16     2017.04.15
      Broad-Band Horn
                            Schwarzbeck     BBHA9120D   9120D-618     2016.04.16     2017.04.15
           Antenna
      Broad-Band Horn
                            Schwarzbeck     BBHA9170     9170-347     2016.04.16     2017.04.15
           Antenna
         Preamplifier       COM-POWER        PA-840       711885      2016.03.26     2017.03.25
     Spectrum Analyzer          R&S           FSP40       100324      2016.03.26     2017.03.25
   Temperature/ Humidity
                              Zhicheng       ZC1-11     CEP-TH-002 2016.03.29        2017.03.28
            Meter
           EZ-EMC               Fala        Ver CT3A1       N/A          N/A            N/A




Cerpass Technology Corp.                                                  Issued Date : Aug 01, 2016
Report format Revision 01                                                 Page No.     : 18 of 30


            CERPASS TECHNOLOGY CORP.                                       Report No.: SEFD1605172

     4.5. Test Result and Data (30MHz~1GHz)
         Test Mode :                Mode 1: Charging Mode(From Computer)
         DC Power :                 DC 3.7V                       Ant. Polarization:   Horizontal
         Temp :                     25   ℃                        Humidity :           48%
         Pressure(mbar) :           1002                          Date :               2016/07/21




   No.    Frequency     Factor           Reading      Level      Limit     Margin      Det.     Height      Azimuth
             (MHz)      (dB/m)           (dBuV)      (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1       30.9699         -2.85            28.90    26.05      40.00      -13.95     peak         100        248
    2      128.9399         -8.93            34.05    25.12      43.50      -18.38     peak         200        136
    3      157.0699         -7.53            34.20    26.67      43.50      -16.83     peak         100        138
    4      323.9100         -6.31            33.55    27.24      46.00      -18.76     peak         100        268
    5      511.1200         -4.63            32.03    27.40      46.00      -18.60     peak         100         60
    6      738.1000         1.62             29.06    30.68      46.00      -15.32     peak         100        241
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                 Issued Date : Aug 01, 2016
Report format Revision 01                                                                Page No.      : 19 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172



   Test Mode :                      Mode 1: Charging Mode(From Computer)
   DC Power :                       DC 3.7V                      Ant. Polarization:   Vertical
   Temp :                           25   ℃                       Humidity :           48%
   Pressure(mbar) :                 1002                         Date :               2016/07/21




   No.   Frequency      Factor           Reading    Level      Limit      Margin      Det.       Height     Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)        (dB)                 (cm)       (deg)
    1       30.9699         -2.85         28.78     25.93      40.00      -14.07      peak         184             0
    2     102.7500      -12.38            34.77     22.39      43.50      -21.11      peak         100         105
    3     157.0699          -7.53         34.34     26.81      43.50      -16.69      peak         200         356
    4     432.5500          -4.61         29.09     24.48      46.00      -21.52      peak         200         38
    5     704.1499          1.18          29.48     30.66      46.00      -15.34      peak         141             0
    6     947.6200          2.53          30.84     33.37      46.00      -12.63      peak         100         209
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.      : 20 of 30


            CERPASS TECHNOLOGY CORP.                                       Report No.: SEFD1605172



         Test Mode :                Mode 2: Normal Communication Mode(By Audio cable)
         DC Power :                 DC 3.7V                       Ant. Polarization:   Horizontal
         Temp :                     25   ℃                        Humidity :           48%
         Pressure(mbar) :           1002                          Date :               2016/07/21




   No.    Frequency     Factor           Reading      Level      Limit     Margin      Det.     Height      Azimuth
             (MHz)      (dB/m)           (dBuV)      (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1       99.8399     -12.83               38.90    26.07      43.50      -17.43     peak         200        129
    2      128.9398         -8.93            34.05    25.12      43.50      -18.38     peak         200        136
    3      157.0699         -7.53            32.20    24.67      43.50      -18.83     peak         100        138
    4      284.1399         -8.84            34.50    25.66      46.00      -20.34     peak         100        215
    5      361.7400         -6.86            32.53    25.67      46.00      -20.33     peak         100        206
    6      715.7898         1.33             29.28    30.61      46.00      -15.39     peak         200        169
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                 Issued Date : Aug 01, 2016
Report format Revision 01                                                                Page No.      : 21 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172



   Test Mode :                      Mode 2: Normal Communication Mode(By Audio cable)
   DC Power :                       DC 3.7V                      Ant. Polarization:   Vertical
   Temp :                           25   ℃                       Humidity :           48%
   Pressure(mbar) :                 1002                         Date :               2016/07/21




   No.   Frequency      Factor           Reading    Level      Limit      Margin      Det.       Height     Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)        (dB)                 (cm)       (deg)
    1     122.1500          -9.61         36.86     27.25      43.50      -16.25      peak         100         200
    2     157.0699          -7.53         35.84     28.31      43.50      -15.19      peak         200         356
    3     176.4698          -7.63         36.71     29.08      43.50      -14.42      peak         100         101
    4     556.7100          -3.42         32.62     29.20      46.00      -16.80      peak         100         319
    5     704.1499          1.18          29.48     30.66      46.00      -15.34      peak         141             0
    6     748.7698          1.42          29.35     30.77      46.00      -15.23      peak         200         33
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.      : 22 of 30


            CERPASS TECHNOLOGY CORP.                                       Report No.: SEFD1605172



         Test Mode :                Mode 3: Wireless Communication Mode(By U+Dongle)
         DC Power :                 DC 3.7V                       Ant. Polarization:   Horizontal
         Temp :                     25   ℃                        Humidity :           48%
         Pressure(mbar) :           1002                          Date :               2016/07/21




   No.    Frequency     Factor           Reading      Level      Limit     Margin      Det.     Height      Azimuth
             (MHz)      (dB/m)           (dBuV)      (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1      128.9398         -8.93            36.05    27.12      43.50      -16.38     peak         200        136
    2      167.7400         -7.55            36.89    29.34      43.50      -14.16     peak         100        209
    3      323.9100         -6.31            33.55    27.24      46.00      -18.76     peak         100        268
    4      421.8799         -3.48            31.86    28.38      46.00      -17.62     peak         100         2
    5      511.1200         -4.63            34.03    29.40      46.00      -16.60     peak         100         60
    6      712.8799         1.29             28.96    30.25      46.00      -15.75     peak         100        241
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                 Issued Date : Aug 01, 2016
Report format Revision 01                                                                Page No.      : 23 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172



   Test Mode :                      Mode 3: Wireless Communication Mode(By U+Dongle)
   DC Power :                       DC 3.7V                      Ant. Polarization:   Vertical
   Temp :                           25   ℃                       Humidity :           48%
   Pressure(mbar) :                 1002                         Date :               2016/07/21




   No.   Frequency      Factor           Reading    Level      Limit      Margin      Det.       Height     Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)        (dB)                 (cm)       (deg)
    1     106.6299      -11.81            37.60     25.79      43.50      -17.71      peak         100         168
    2     157.0699          -7.53         34.34     26.81      43.50      -16.69      peak         200         356
    3     335.5500          -6.50         32.51     26.01      46.00      -19.99      peak         200         336
    4     432.5500          -4.61         31.59     26.98      46.00      -19.02      peak         200         38
    5     511.1200          -4.63         31.65     27.02      46.00      -18.98      peak         200         210
    6     704.1499          1.18          28.48     29.66      46.00      -16.34      peak         141             0
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.      : 24 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172

     4.6. Test Result and Data (1GHz ~ 18GHz)
   Test Mode :                  Mode 1: Charging Mode(From Computer)
   DC Power :                   DC 3.7V                      Ant. Polarization:      Horizontal
   Temp :                       25   ℃                       Humidity :              48%
   Pressure(mbar) :             1002                         Date :                  2016/07/21




   No.   Frequency          Factor   Reading       Level        Limit       Margin     Det.       Height      Azimuth
             (MHz)          (dB/m)       (dBuV)   (dBuV/m)   (dBuV/m)        (dB)                 (cm)          (deg)
    1       1663.000        -14.09       58.12     44.03        74.00       -29.97     peak        100           245
    2       2479.000        -10.04       53.66     43.62        74.00       -30.38     peak        100           328
    3       3210.000        -7.61        52.67     45.06        74.00       -28.94     peak        200           96
    4       3550.000        -6.16        50.64     44.48        74.00       -29.52     peak        100           74
    5       4893.000        -3.83        47.62     43.79        74.00       -30.21     peak        100           105
    6       6916.000        -0.23        46.90     46.67        74.00       -27.33     peak        100            1
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.         : 25 of 30


            CERPASS TECHNOLOGY CORP.                                        Report No.: SEFD1605172



   Test Mode :                      Mode 1: Charging Mode(From Computer)
   DC Power :                       DC 3.7V                    Ant. Polarization:    Vertical
   Temp :                           25   ℃                     Humidity :            48%
   Pressure(mbar) :                 1002                       Date :                2016/07/21




   No.   Frequency      Factor           Reading    Level      Limit        Margin    Det.      Height       Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)       (dB)               (cm)           (deg)
    1     1459.000      -15.21            59.15     43.94      74.00        -30.06   peak         200            85
    2     1816.000      -13.22            57.10     43.88      74.00        -30.12   peak         100           327
    3     2292.000      -10.87            53.68     42.81      74.00        -31.19   peak         100            15
    4     2734.000          -9.27         57.81     48.54      74.00        -25.46   peak         200           224
    5     3346.000          -7.03         54.03     47.00      74.00        -27.00   peak         100            96
    6     4145.000          -4.18         49.20     45.02      74.00        -28.98   peak         100           264
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                 Issued Date : Aug 01, 2016
Report format Revision 01                                                                Page No.       : 26 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172



   Test Mode :                  Mode 2: Normal Communication Mode(By Audio cable)
   DC Power :                   DC 3.7V                      Ant. Polarization:      Horizontal
   Temp :                       25   ℃                       Humidity :              48%
   Pressure(mbar) :             1002                         Date :                  2016/07/21




   No.   Frequency          Factor   Reading       Level        Limit       Margin     Det.       Height      Azimuth
             (MHz)          (dB/m)       (dBuV)   (dBuV/m)   (dBuV/m)        (dB)                 (cm)          (deg)
    1       1663.000        -14.09       58.62     44.53        74.00       -29.47     peak        100            8
    2       2190.000        -11.33       58.04     46.71        74.00       -27.29     peak        100           205
    3       2785.000        -9.12        55.47     46.35        74.00       -27.65     peak        100           324
    4       3210.000        -7.61        52.67     45.06        74.00       -28.94     peak        200           105
    5       3550.000        -6.16        50.64     44.48        74.00       -29.52     peak        100           227
    6       4893.000        -3.83        47.12     43.29        74.00       -30.71     peak        100            4
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.         : 27 of 30


            CERPASS TECHNOLOGY CORP.                                        Report No.: SEFD1605172



   Test Mode :                      Mode 2: Normal Communication Mode(By Audio cable)
   DC Power :                       DC 3.7V                    Ant. Polarization:    Vertical
   Temp :                           25   ℃                     Humidity :            48%
   Pressure(mbar) :                 1002                       Date :                2016/07/21




   No.   Frequency      Factor           Reading    Level      Limit        Margin    Det.      Height       Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)       (dB)               (cm)           (deg)
    1     1459.000      -15.21            61.65     46.44      74.00        -27.56   peak         100           201
    2     1901.000      -12.73            59.76     47.03      74.00        -26.97   peak         100            41
    3     2734.000          -9.27         56.31     47.04      74.00        -26.96   peak         100           336
    4     3125.000          -7.97         54.75     46.78      74.00        -27.22   peak         100            95
    5     3346.000          -7.03         52.53     45.50      74.00        -28.50   peak         100           274
    6     8242.000          1.92          46.19     48.11      74.00        -25.89   peak         100            9
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                 Issued Date : Aug 01, 2016
Report format Revision 01                                                                Page No.       : 28 of 30


            CERPASS TECHNOLOGY CORP.                                      Report No.: SEFD1605172



   Test Mode :                  Mode 3: Wireless Communication Mode(By U+Dongle)
   DC Power :                   DC 3.7V                      Ant. Polarization:      Horizontal
   Temp :                       25   ℃                       Humidity :              48%
   Pressure(mbar) :             1002                         Date :                  2016/07/21




   No.   Frequency          Factor   Reading       Level        Limit       Margin     Det.       Height      Azimuth
             (MHz)          (dB/m)       (dBuV)   (dBuV/m)   (dBuV/m)        (dB)                 (cm)          (deg)
    1       1663.000        -14.09       57.12     43.03        74.00       -30.97     peak        100           328
    2       1986.000        -12.25       56.77     44.52        74.00       -29.48     peak        100           45
    3       2207.000        -11.25       58.60     47.35        74.00       -26.65     peak        100           75
    4       2785.000        -9.12        54.47     45.35        74.00       -28.65     peak        200           93
    5       3499.000        -6.38        53.15     46.77        74.00       -27.23     peak        200           214
    6       5743.000        -2.49        47.18     44.69        74.00       -29.31     peak        100           102
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                                Issued Date : Aug 01, 2016
Report format Revision 01                                                               Page No.         : 29 of 30


            CERPASS TECHNOLOGY CORP.                                         Report No.: SEFD1605172



   Test Mode :                      Mode 3: Wireless Communication Mode(By U+Dongle)
   DC Power :                       DC 3.7V                     Ant. Polarization:    Vertical
   Temp :                           25   ℃                      Humidity :            48%
   Pressure(mbar) :                 1002                        Date :                2016/07/21




   No.    Frequency     Factor           Reading    Level       Limit        Margin    Det.      Height       Azimuth
            (MHz)       (dB/m)           (dBuV)    (dBuV/m)   (dBuV/m)        (dB)               (cm)           (deg)
    1      1459.000     -15.21            59.15     43.94       74.00        -30.06   peak         100           201
    2      1850.000     -13.02            58.64     45.62       74.00        -28.38   peak         200           159
    3      2190.000     -11.33            59.95     48.62       74.00        -25.38   peak         200            35
    4      2734.000         -9.27         55.31     46.04       74.00        -27.96   peak         100            41
    5      3346.000         -7.03         53.53     46.50       74.00        -27.50   peak         100           127
    6      4026.000         -4.22         53.20     48.98       74.00        -25.02   peak         100            8
  Note: Measurement Level = Reading Level + Correct Factor




         Test engineer:




                                                            The end


Cerpass Technology Corp.                                                                  Issued Date : Aug 01, 2016
Report format Revision 01                                                                 Page No.       : 30 of 30



Document Created: 2016-08-31 09:02:31
Document Modified: 2016-08-31 09:02:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC