RF Exposure

FCC ID: SYW-DIMWIFI

RF Exposure Info

Download: PDF
FCCID_4481219

Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ190722552-00

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
             Frequency           Electric Field     Magnetic Field        Power          Averaging
               Range                Strength           Strength          Density           Time
               (MHz)                 (V/m)              (A/m)           (mW/cm2)         (Minutes)
               0.3-1.34               614                   1.63        *(100)                30
               1.34-30               824/f                 2.19/f      *(180/f2)              30
                30-300                27.5                 0.073            0.2               30
               300-1500                   /                  /          f/1500                30
           1500-100,000                   /                  /              1.0               30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                            PG
                                                      S=
                                                           4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                                              Tune-up Conducted     Evaluation        Power
   Frequency              Antenna Gain                                                             MPE Limit
                                                    Power            Distance        Density
     (MHz)                                                                                         (mW/cm2)
                    (dBi)       (numeric)     (dBm)     (mW)          (cm)          (mW/cm2)
   2412-2462         2.5           1.78        17.5         56.23      20              0.02             1

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance



FCC Part 15.247                                                                                    Page 13 of 49



Document Created: 2019-10-17 00:08:26
Document Modified: 2019-10-17 00:08:26