RF Exposure

FCC ID: SYW-A21RGBWAGT2

RF Exposure Info

Download: PDF
FCCID_4415336

Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ190514552-00

FCC §15.247 (i) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 2.1091 systems operating under the provisions of this section
shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the
communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
             Frequency           Electric Field     Magnetic Field        Power           Averaging
               Range                Strength           Strength          Density            Time
               (MHz)                 (V/m)              (A/m)           (mW/cm2)          (Minutes)
               0.3-1.34               614                   1.63        *(100)                  30
                                                                                  2
               1.34-30               824/f                 2.19/f      *(180/f )                30
                30-300                27.5                 0.073            0.2                 30
               300-1500                   /                  /          f/1500                  30
           1500-100,000                   /                  /              1.0                 30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                            PG
                                                      S=
                                                           4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


   Frequency                                  Tune up conducted     Evaluation          Power
                          Antenna Gain                                                               MPE Limit
     Range                                          power            Distance          Density
                                                                                                     (mW/cm2)
     (MHz)          (dBi)       (numeric)     (dBm)      (mW)         (cm)            (mW/cm2)
   2412-2472          2            1.58        14.5         28.18      20              0.0089            1.0

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance




FCC Part 15.247                                                                                      Page 13 of 48



Document Created: 2019-09-02 22:35:23
Document Modified: 2019-09-02 22:35:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC