Test Report

FCC ID: SY4-A02010

Test Report

Download: PDF
FCCID_3224089

                                              FCC PART 15B
                   MEASUREMENT AND TEST REPORT
                                                             For


          Shanghai Huace Navigation Technology LTD.
                                Building C,599 Gaojing Road,Qingpu District Shanghai



                                          FCC ID: SY4-A02010



              Report Type:                                      Product Type:
              Original Report                                  GNSS Receiver



                    Test Engineer:        Phil Zhu

                 Report Number:           RKS161114001-00A

                      Report Date:        2016-11-15
                                          Jesse huang

                     Reviewed By:         EMC Manager

                     Prepared By:         Bay Area Compliance Laboratories Corp. (Kunshan)
                                          No.248 Chenghu Road, Kunshan,Jiangsu province,
                                          China
                                          Tel: +86-0512-86175000
                                          Fax: +86-0512-88934268
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid
digital signature. The digital signature may be available only under the Adobe software above version 7.0.


Bay Area Compliance Laboratories Corp. (Kunshan)                                                                            Report No.: RKS161114001-00A




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF RADIATED TEST SETUP...............................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  CORRECTED FACTOR & MARGIN CALCULATION .........................................................................................................9
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................13
  APPLICABLE STANDARD ............................................................................................................................................13
  MEASUREMENT UNCERTAINTY ..................................................................................................................................13
  EUT SETUP ................................................................................................................................................................13
  EMI TEST RECEIVER SETUP .......................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
  TEST RESULTS SUMMARY ..........................................................................................................................................15
  TEST DATA ................................................................................................................................................................15
PRODUCT SIMILARITY DECLARATION LETTER ..........................................................................................18




FCC Part 15B                                                                                                                                               Page 2 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                             Report No.: RKS161114001-00A


GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

           Manufacturer        Shanghai Huace Navigation Technology LTD.
              Model            P3E
             Product           GNSS Receiver
           Rate Voltage        DC 9-36V,rated power :4.2W

       Operating temperature   -25 °C to +65 °C (-13°F to 149°F)
        Storage temperature    -40 °C to +80°C (-40°F to 176°F)
       Operating Frequency     1575.42MHz
            Dimension          215 mm (L) × 140mm (W) × 68 mm (H)

Note: The product’ s series model number: P3;P3X(X=0-9,A-Z), The difference between them was explained in the
attached declaration letter.


*All measurement and test data in this report was gathered from production sample serial number: 20160918003
(Assigned by BACL, Kunshan). The EUT was received on 2016-09-18.

Objective
This report is prepared on behalf of Shanghai Huace Navigation Technology LTD.in accordance with Part
2-Subpart J, and Part 15-Subparts A and B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15, Class B.
Related Submittal(s)/Grant(s)
N/A.

Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Kunshan). The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




FCC Part 15B                                                                                     Page 3 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                            Report No.: RKS161114001-00A

Test Facility

The test site used by Bay Area Compliance Laboratories Corp. (Kunshan) to collect test data is located on
the No.248 Chenghu Road, Kunshan,Jiangsu province, China

Test site at Bay Area Compliance Laboratories Corp. (Kunshan) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on November 06, 2014. The
facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.4.

The Federal Communications Commission has the reports on file and is listed under FCC Registration
No.:815570. The test site has been approved by the FCC for public use and is listed in the FCC Public
Access Link (PAL) database.




FCC Part 15B                                                                                   Page 4 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                              Report No.: RKS161114001-00A

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).
Test mode 1: GPS mode & Link LAN 100Mbps

EUT Exercise Software
No exercise software was used.

Special Accessories
No special accessory was used.

Equipment Modifications
No modification was made to the EUT tested.


Support Equipment List and Details


      Manufacturer              Description                 Model                Serial Number

          DELL                      PC                      GX620                  D65874152
        MEGURO            GPS Signal Generator          MSG-2050                      N/A
          SHNT                 GNSS Antenna              A220GR                     14040306
       U Flash Disk        Cement Resistance           5ohm/1500W                      NA
           NA                     Mouse                     F8108                      NA


External I/O Cable

                 Cable Description                 Length (m)        From/Port               To

                        RJ45                          1.8               EUT                  NB

                 USB Extension Wire                   1.0               NB                  U Flash

                      USB Cable                       1.0               NB                  Mouse




FCC Part 15B                                                                                       Page 5 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                               Report No.: RKS161114001-00A

Block Diagram of Radiated Test Setup
Test mode 1



     AC Power                GPS Gennarator                  Antenna



                                        Data & Power Cable

                       GNSS Cable                             RJ45 Cable


                  GNSS               EUT                 EUT                 Notebook
                  Antenna                                Adapter




                                                                   U Flash              Mouse
                                                                    Disk


                Non-Conductive Table 80cm
                Above Ground Plane                            1.5m*1.0m*0.8m Table




FCC Part 15B                                                                                    Page 6 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                  Report No.: RKS161114001-00A

SUMMARY OF TEST RESULTS


          FCC Rules                         Description of Test             Results

            §15.107                        Conducted Emissions            Compliance

            §15.109                         Radiated Emissions            Compliance




FCC Part 15B                                                                          Page 7 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                           Report No.: RKS161114001-00A


FCC §15.107 –CONDUCTED EMISSIONS
Applicable Standard

According to FCC§15.107

Measurement Uncertainty

Input quantities to be considered for conducted disturbance measurements maybe receiver reading,
attenuation of the connection between LISN and receiver, LISN voltage division factor, LISN VDF
frequency interpolation and receiver related input quantities, etc.

Based on CISPR 16-4-2:2011+A1-2014, the expended combined standard uncertainty of conducted
disturbance test at Bay Area Compliance Laboratories Corp. (Kunshan) is shown as below. And the
uncertainty will not be taken into consideration for the test data recorded in the report.

                          Port                        Expanded Measurement uncertainty
                       AC Mains                       3.26 dB (k=2, 95% level of confidence)
                         CAT 3                        3.70 dB (k=2, 95% level of confidence)
                         CAT 5                        3.86 dB (k=2, 95% level of confidence)
                         CAT 6                        4.64 dB (k=2, 95% level of confidence)



EUT Setup




FCC Part 15B                                                                                   Page 8 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                  Report No.: RKS161114001-00A

The measurement procedure of EUT setup is according with ANSI C63.4-2014. The related limit was
specified in FCC Part 15.107 Class B.

The EUT was connected to an AC 120V/60 Hz power source.

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                Frequency Range                          IF B/W
                                150 kHz – 30 MHz                          9 kHz

Test Procedure
During the conducted emission test, the EUT was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.


Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
      Manufacturer              Description            Model
                                                                      Number           Date         Due Date
     Rohde & Schwarz         EMI Test Receiver        ESCS30         934115/007      2015-11-11     2016-11-10
     Rohde & Schwarz               LISN              ESH3-Z5         862770/011      2015-11-12     2016-11-11
     Rohde & Schwarz               LISN              ESH3-Z5         892239/018     2016-06-23      2017-06-22
     Rohde & Schwarz          Transient Limiter       ESH3Z2          DE25985       2016-09-16      2017-09-15
     Rohde & Schwarz         CE Test software       EMC 32            V 09.10.0          --              --
                                                  UFB-293B-1-0
      MICRO-COAX                Coaxial line                          97F0173       2016-10-01      2017-10-01
                                                   480-50X50

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Kunshan) attests that all calibrations have
  been performed in accordance to requirements that traceable to National Primary Standards and International
  System of Units (SI).


Corrected Factor & Margin Calculation

The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
     Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
       Margin = Limit – Corrected Amplitude


FCC Part 15B                                                                                          Page 9 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                    Report No.: RKS161114001-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107 Class B,
the worst margin reading as below:
                                 0.74 dB at 0.595000 MHz in the Line conducted mode

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                              Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

            Temperature:               25℃
       Relative Humidity:              51 %
           ATM Pressure:             101.0 kPa

     The testing was performed by Phil Zhu on 2016-10-21.




FCC Part 15B                                                                                             Page 10 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                    Report No.: RKS161114001-00A

Test Model1
      Line


                         120

                         100

                         80
          Level in dBμ




                         60

                         40

                         20

                          0



                          150k    300 400 500    800 1M       2M    3M 4M 5M 6      8 10M      20M   30M
                                                          Frequency in Hz



                                  Corrected Amplitude
         Frequency                                          Limit       Margin                  Corr.
                                 QuasiPeak    Average                                 Line
           (MHz)                                          (dBμV)         (dB)                   (dB)
                                  (dBμV)      (dBμV)
          0.595000                  ---         45.26       46.00           0.74      L1         10.3
          0.595000                 52.25         ---        56.00           3.75      L1         10.3
          0.925000                  ---         28.35       46.00           17.65     L1         10.3
          0.925000                 35.61         ---        56.00           20.39     L1         10.3
          1.310000                  ---         29.02       46.00           16.98     L1         10.3
          1.310000                 35.82         ---        56.00           20.18     L1         10.3
          1.675000                  ---         28.40       46.00           17.60     L1         10.4
          1.675000                 35.30         ---        56.00           20.70     L1         10.4
          2.490000                  ---         27.67       46.00           18.33     L1         10.4
          2.490000                 35.65         ---        56.00           20.35     L1         10.4
          5.120000                  ---         30.50       50.00           19.50     L1         10.5
          5.120000                 36.08         ---        60.00           23.92     L1         10.5




FCC Part 15B                                                                                            Page 11 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                          Report No.: RKS161114001-00A

        Neutral


                           120

                           100

                           80
            Level in dBμ




                           60

                           40

                           20

                            0



                            150k      300 400 500     800 1M       2M    3M 4M 5M 6       8 10M      20M     30M
                                                               Frequency in Hz



                                     Corrected Amplitude
            Frequency                                           Limit            Margin               Corr.
                                   QuasiPeak    Average                                     Line
              (MHz)                                            (dBμV)             (dB)                (dB)
                                    (dBμV)      (dBμV)
             0.170000                39.24           ---        64.96            25.72       N        10.3
             0.170000                 ---           26.42       54.96            28.54       N        10.3
             0.595000                52.01           ---        56.00             3.99       N        10.3
             0.595000                 ---           45.00       46.00             1.00       N        10.3
             0.970000                36.18           ---        56.00            19.82       N        10.3
             0.970000                 ---           29.04       46.00            16.96       N        10.3
             1.705000                35.62           ---        56.00            20.38       N        10.4
             1.705000                 ---           28.44       46.00            17.56       N        10.4
             2.810000                36.32           ---        56.00            19.68       N        10.5
             2.810000                 ---           30.20       46.00            15.80       N        10.5
             5.180000                 ---           29.82       50.00            20.18       N        10.6
             5.180000                35.67           ---        60.00            24.33       N        10.6


Note:
         1) Corrected Amplitude = Reading + Correction Factor
         2) Margin = Limit – Corrected Amplitude




FCC Part 15B                                                                                                  Page 12 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                              Report No.: RKS161114001-00A


FCC §15.109 - RADIATED SPURIOUS EMISSIONS
Applicable Standard
FCC §15.109

Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.
Based on CISPR 16-4-2:2011+A1-2014, the expended combined standard uncertainty of radiation
emissions at Bay Area Compliance Laboratories Corp. (Kunshan) is shown in below table. And the
uncertainty will not be taken into consideration for the test data recorded in the report

           Frequency                           Polarity                    Measurement uncertainty
                                              Horizontal              4.62 dB (k=2, 95% level of confidence)
        30 MHz~200 MHz
                                               Vertical               4.54 dB (k=2, 95% level of confidence)
                                              Horizontal              4.84 dB (k=2, 95% level of confidence)
         200 MHz~1 GHz
                                               Vertical               5.91 dB (k=2, 95% level of confidence)
          1 GHz~6 GHz                     Horizontal/Vertical         4.68 dB (k=2, 95% level of confidence)
          Above 6 GHz                     Horizontal/Vertical         4.92 dB (k=2, 95% level of confidence)


EUT Setup




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.


FCC Part 15B                                                                                      Page 13 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                    Report No.: RKS161114001-00A

EMI Test Receiver Setup
The system was investigated from 30 MHz to 9 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

          Frequency Range             RBW             Video B/W            IF B/W             Detector

         30 MHz – 1000 MHz           100 kHz            300 kHz            120 kHz              QP
               1GHz-9GHz              1MHz               3MHz                   -               PK
               1GHz-9GHz              1MHz                10Hz                  -               AV


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz.

Test Equipment List and Details

                                                                      Serial          Calibration    Calibration
    Manufacturer           Description             Model
                                                                    Number               Date         Due Date
  Sonoma Instrunent          Amplifier              330              171377            2016-09-16    2017-09-15
  Rohde & Schwarz       EMI Test Receiver          ESCI              100195            2015-11-12    2016-11-11
   Sunol Sciences       Broadband Antenna           JB3            A090314-2           2016-01-09    2017-01-08
        ETS                Horn Antenna            3115               6229             2016-01-11    2017-01-10
  Rohde & Schwarz         Signal Analyzer         FSIQ26             100048            2015-11-12    2016-11-11
        Mini               Pre-amplifier        ZVA-183-S+         857001418           2016-09-16    2017-09-15
     champrotek              Chamber             Chamber A          V 09.10.0               -             -
        R&S             Auto test Software        EMC32             V 09.10.0               -             -
                                               UFB-293B-1-04
   MICRO-COAX              Coaxial line                              97F0173           2016-10-01    2017-10-01
                                                 80-50X50

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Kunshan) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15B                                                                                           Page 14 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                    Report No.: RKS161114001-00A

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
         Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin calculation
is as follows:
         Margin = Limit – Corrected Amplitude


Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.109 Class B, with the worst
margin reading of:

                       10.33 dB at 248.913600 MHz in the Horizontal polarization mode

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                              Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

                Temperature:                 27 ℃
          Relative Humidity:                 56 %
               ATM Pressure:              101.0 kPa

      The testing was performed by Phil Zhu on 2016-10-27.




FCC Part 15B                                                                                             Page 15 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                                                Report No.: RKS161114001-00A

Test Model1

30MHz ~ 1GHz



                           80

                           70

                           60
          Level in dBμV/




                           50

                           40

                           30

                           20

                           10

                           0
                           30M               50   60     80 100M            200       300   400   500       800   1G
                                                                    Frequency in Hz

                                 Corrected
  Frequency                                                     Limit      Margin      Height           Azimuth     Corr.
                                Amplitude                                                         Pol
    (MHz)                                         Detector    (dBμV/m)      (dB)        (cm)             (deg)     (dB/m)
                                (dBμV/m)

  40.933000                       28.50           QuasiPeak     40.00       11.50      101.0      V      245.0       -10.8

  47.995150                       29.52           QuasiPeak     40.00       10.48      101.0      V      78.0        -15.2

 232.322150                       33.21           QuasiPeak     46.00       12.79      101.0      H      95.0        -12.2

 248.913600                       35.67           QuasiPeak     46.00       10.33      101.0      H      128.0       -12.0

 423.868000                       29.05           QuasiPeak     46.00       16.95      101.0      V      154.0         -7.8

 846.144550                       33.28           QuasiPeak     46.00       12.72      101.0      V      112.0         -1.3




FCC Part 15B                                                                                                      Page 16 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                         Report No.: RKS161114001-00A

      Above 1GHz


    Frequency     MaxPeak       Average       Limit    Margin   Height           Azimuth    Corr.
                                                                           Pol
      (MHz)      (dBμV/m)     (dBμV/m)      (dBμV/m)    (dB)     (cm)             (deg)    (dB /m)

   1000.090180       ---         30.12         53.90   23.78    149.0      H      130.0      -11.3
   1000.090180      37.80          ---         73.90   36.10    149.0      H      130.0      -11.3
   1809.609219      40.46          ---         73.90   33.44    149.0      V      100.0      -5.9
   1809.609219       ---         22.16         53.90   31.74    149.0      V      100.0      -5.9
   2713.597195      40.20          ---         73.90   33.70    149.0      V      218.0      -1.7
   2713.597195       ---         24.32         53.90   29.58    149.0      V      218.0      -1.7
   3060.811623       ---         25.36         53.90   28.54    149.0      V      120.0       0.3
   3060.811623      39.80          ---         73.90   34.10    149.0      V      120.0       0.3
   5448.006012      44.53          ---         73.90   29.37    149.0      V      244.0       9.3
   5448.006012       ---         30.55         53.90   23.35    149.0      V      244.0       9.3
   6648.406813      49.80          ---         73.90   24.10    149.0      H      300.0      13.3
   6648.406813       ---         36.07         53.90   17.83    149.0      H      300.0      13.3




FCC Part 15B                                                                               Page 17 of 18


Bay Area Compliance Laboratories Corp. (Kunshan)                  Report No.: RKS161114001-00A


PRODUCT SIMILARITY DECLARATION LETTER
Company: Shanghai Huace Navigation Technology LTD.
Add: Building C,599 Gaojing Road,Qingpu District.Shanghai.China
Tel:021-51508100-1241
Fax:021-64851208
                                           DECLARATION
Dear Sir or Madam:
We, Shanghai Huace Navigation Technology LTD. hereby declare that product series of
P3E,P3and P3X (X=0~9,A~Z),They are based on the same of hardware and
software. The differences of them are as follows:
1. The model name
Please contact me if there is need for any additional clarification or information.
Best Regards,

Signature:
Name/Title:Zhangdan / Test engineer
E-mail:dan_zhang@huace.cn
Date: 2016-11-10




                                   ***** END OF REPORT *****