Test Report

FCC ID: SY4-A02003

Test Report

Download: PDF
FCCID_2738937

Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                           Page 1 of 14




                 FCC Part 15B TEST REPORT

                         Product Name : GNSS receiver
                         Model Name        : N72 WXYZ




                                        Prepared for:
                Shanghai Huace Navigation Technology LTD.
           Building C,599 Gaojing Road,Qingpu District,Shanghai
                          TEL: 021-51508100-1242
                            FAX: 021-64851208


                                        Prepared by:
                         Unilab (Shanghai) Co., Ltd.
                    FCC 2.948 register number is 714465
                       IC register number is 11025A-1
         No. 1350, Lianxi Rd. Pudong New District, Shanghai, China
                            TEL: +86-21-50275125
                            FAX: +86-21-50275126




                Report Number       :   UL41320150312CE/FCC003-1
                Date of Report      :   05-11-2015
                Date of Test        :   05-11-2015



Notes:
The test results only relate to these samples which have been tested.
Partly using this report will not be admitted unless been allowed by Unilab.
Unilab is only responsible for the complete report with the reported stamp of Unilab.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                       Page 2 of 14



Applicant:           Shanghai Huace Navigation Technology LTD

                     Building C,599 Gaojing Road,Qingpu District,Shanghai

Manufacturer:        Shanghai Huace Navigation Technology LTD

                     Building C,599 Gaojing Road,Qingpu District,Shanghai

Product Name:        GNSS receiver
Brand Name:


Model Name:          N72 WXYZ


Model Description: See Part1.6
FCC ID:              SY4-A02003

EUT Voltage:         Extreme Low:12V, Nominal:12V, Extreme High:36V
Date of Receipt:     03-12-2015
Test Standard:       FCC CFR Tile 47 Part 15 Subpart B
Test Result:         Pass
Date of Test         05-11-2015



             Prepared by :
                                  (Technical Engineer: Paul Yang)


             Reviewed by :
                                   (Senior Engineer: Forest Cao)


             Approved by :
                                        (Supervisor: Eva Wang)


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                                                        Page 3 of 14



                                          TABLE OF CONTENTS
1.  TECHNIACL SUMMARY ...................................................................................... 4
    1.1    SUMMARY OF STANDARDS AND TEST RESULTS ............................... 4
    1.2    TEST UNCERTAINTY ............................................................................... 4
    1.3    TEST EQUIPMENT LIST ........................................................................... 4
    1.4    SUPPORT EQUIPMENT AND CABLE ...................................................... 4
    1.5    CABLE OF TEST ....................................................................................... 4
    1.6    TEST MODE AND DESCRIPTION ............................................................ 5
    1.7    TEST FACILITY ......................................................................................... 5
    1.8    TEST SETUP CONFIGURATION .............................................................. 5
2.  CONDUCTED DISTURBANCE ............................................................................ 6
    2.1    TEST SETUP ............................................................................................. 6
    2.2    LIMITS ....................................................................................................... 6
    2.3    TEST PROCEDURE .................................................................................. 6
    2.4    TEST RESULT ........................................................................................... 7
3.  RADIATED DISTURBANCE (RE) ........................................................................ 9
    3.1    TEST SETUP ............................................................................................. 9
    3.2    LIMITS ....................................................................................................... 9
    3.3    TEST PROCEDURE ................................................................................ 10
    3.4    TEST RESULT ......................................................................................... 11
APPENDIX 1       PHOTOGRAPHS OF TEST SETUP.............................................. 14
APPENDIX 2       PHOTOGRAPHS OF EUT ............................................................ 14


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                                          Page 4 of 14




1. TECHNIACL SUMMARY
1.1 SUMMARY OF STANDARDS AND TEST RESULTS
The EUT have been tested according to the applicable standards as referenced below:
                             Test Item                             FCC              Result
                  Conducted disturbance                FCC 15.107                      P*
                  Radiated disturbance                 FCC 15.109                      P
                  Note: P means pass, F means failure, N/A means not applicable

1.2 TEST UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an
expanded uncertainty expressed at approximately the 95% confidence level using a
coverage factor of k=2.
                                  Test item                        Value (dB)
                          Conducted disturbance                        3.4
                           Radiated disturbance                        4.2

1.3 TEST EQUIPMENT LIST
       Equipment               Manufacturer            Model          Serial No.   Due Date        Cal interval
         Receiver                  Agilent             N9038A       MY51210142 11/11/2015             1 year
           LISN                      R&S             NNBM 8126F          1035      22/08/2015         1 year
3m Chamber & Accessory
                       ETS-LINDGREN                    FACT-3        CT-0000336    26/11/2017        3 years
      Equipment
   Biconilog Antenna   SCHWARZBECK                   VULB 9160           3316      19/09/2016        2 years
       Horn Antenna          SCHWARZBECK             BBHA9120D           942       19/09/2016        2 years
 Microwave Preamplifier       EM Electronics          EM30180        3008A02425    27/02/2016         1 year

1.4 SUPPORT EQUIPMENT AND CABLE
   Equipment          Manufacturer          Model                    Serial No.                    Due Date
         PC               DELL        VOSTRO 260                      7JXLB3X                         /
      Displayer           DELL             E1910Hc       CN-0CD1MT-64180-OC7-06TS                     /
       Mouse              DELL           MS111-P             CN-0MF3JY-71581-2C7-05GB                 /
      Keyboard            DELL             KB212-B      CN-0Y88XT-65890-22L-01MG-A01                  /


1.5 CABLE OF TEST
 No.     Cable Type       Quantity    Provider Length(m) Specification                      Note
  1        AC Cable           2            Unilab      1.5        Unshielded                None
  2       USB cable           1          Queclink      1.0        Unshielded                None
  3       VGA Cable           1            Unilab      1.5        Unshielded                None


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                                      Page 5 of 14



1.6 TEST MODE AND DESCRIPTION
 Test mode      Data exchange with USB cable,
             The EUT connect to PC with a USB cable, then the command ”AT+EADC=1”
              was sent through the hyperterminal to achieve data exchange between PC
              and EUT.
             Model N72 WXYZ, W is variable, it indicated A-Z or 0-9 or blank,X is
 Description
             variable, it indicated A-Z or 0-9 or blank,Y is variable, it indicated A-Z, 0-9 or
             blank. Z is variable, it indicated A-Z, 0-9 or blank. due to sales purpose in
             different countries or regions. The internal PCB design are no difference,but
             only distinct in colours and model names. The test model name is N72.

1.7 TEST FACILITY
All test facilities used to collect the test data are located at No. 1350, Lianxi Rd. Pudong New
District, Shanghai, China. The site and apparatus are constructed in conformance with the
requirements of ANSI C63.4: 2009, CISPR 16-1-1 and other equivalent standards. The
laboratory is compliance with the requirements of the ISO/IEC/EN17025.

1.8 TEST SETUP CONFIGURATION
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
Notes:
1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during
the test.
2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the
intended use.
3. All the tests were carried out with the EUT in normal operation. Which was shown in this test report is
the worst test mode.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                                     Page 6 of 14




2. CONDUCTED DISTURBANCE
2.1 TEST SETUP
For mains port:




2.2 LIMITS
                                  Limits for Class B digital devices
                                                          Limits
           Frequency range
                                                          dB(μV)
                (MHz)
                                          Quasi-peak                       Average
              0,15 to 0,50                  66 to 56                       56 to 46
                0,50 to 5                      56                             46
                 5 to 30                       60                             50
NOTE: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50 MHz.

2.3 TEST PROCEDURE
For mains port:
a. The EUT and support equipment were placed on a nonconductive table 0.8m above the
horizontal ground reference plane, and 0.4 m from the vertical ground reference plane. The
EUT connected to the main through Line Impedance Stability Network (L.I.S.N) to provide a
50 /50uH coupling impedance for the measuring equipment. The support equipment is
also connected to the main power through a LISN that provides a 50 /50uH coupling
impedance with 50  terminations. Both sides of AC line (Line & Neutral) were checked to
find out the maximum conducted emission.
b. The RBW of the receiver was set at 9 kHz. The frequency range from 150 kHz to 30 MHz
was checked. Run the receiver’s pre-scan to record the maximum disturbance generated
from EUT in all power lines in the full band.
c. For each frequency whose maximum record was higher or close to limit, measure its QP
and AVG values and record.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1             Page 7 of 14



2.4 TEST RESULT
For mains port:

Test mode:   Data exchange by USB cable   LISN:   Positive


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1             Page 8 of 14




Test mode:   Data exchange by USB cable   LISN:    Neutral


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                               Page 9 of 14




3. RADIATED DISTURBANCE (RE)
3.1 TEST SETUP
30MHz ~ 1GHz:




Above 1GHz:




3.2 LIMITS
                                Limits for Class B digital devices
                                                           limits at 3m
              Frequency (MHz)
                                                             dB(μV/m)

                    30-88                                     40.0
                   88-216                                     43.5
                   216-960                                    46.0
                 Above 960                                    54.0
NOTE: 1. The lower limit shall apply at the transition frequency.
        2. The limits shown above are based on measuring equipment employing a CISPR quasi-peak
detector function for frequencies below or equal to 1000MHz.
        3. The limits shown above are based on measuring equipment employing an average detector
function for frequencies above 1000MHz.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                          Page 10 of 14



3.3 TEST PROCEDURE
30MHz ~ 1GHz:
a. The EUT and support equipment were placed on the non-conductive turntable 0.8m
above the horizontal metal ground plane at a chamber. The EUT was set 3 meters away
from the receiving antenna, which was mounted on an antenna tower. Broadband antenna
(Calibrated Bilog Antenna) was used as receiving antenna.
b. The frequency range from 30MHz to 1GHz was checked. The RBW of the receiver was
set at 120kHz. Set the receiver in Peak detector, Max Hold mode. Record the maximum field
strength of all the pre-scan process in the full band when the antenna is varied between 1~4
m in both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
c. For each frequency whose maximum record was higher or close to limit, measure its QP
value: vary the antenna’s height and rotate the turntable from 0 to 360 degrees to find the
height and degree where EUT radiated the maximum emission, then set the test frequency
receiver to QP Detector and record the maximum value.
Above 1GHz:
a. The EUT and support equipment were placed on the non-conductive turntable 0.8m
above the ground at a chamber. The EUT was set 3 meters away from the receiving
antenna, which was mounted on an antenna tower. Horn antenna was used as receiving
antenna.
b. The frequency range above 1GHz was checked. The RBW of the receiver was set at
1MHz. Set the receiver in Peak detector, Max Hold mode. Record the maximum field
strength of all the pre-scan process in the full band when the antenna is 1m and varied in
both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
c. For each frequency whose maximum record was higher or close to limit, measure its
Average value: rotate the turntable from 0 to 360 degrees to find the degree where EUT
radiated the maximum emission, then set the test frequency receiver to EMI Average
Detector and record the maximum value.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                            Page 11 of 14



3.4 TEST RESULT
30MHz ~ 1GHz:

  Test mode:    Data exchange by USB cable   Antenna Polarity:   Horizontal


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                            Page 12 of 14



   Test mode:   Data exchange by USB cable   Antenna Polarity:    Vertical


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                            Page 13 of 14



Above 1GHz:

  Test mode:    Data exchange by USB cable   Antenna Polarity:   Horizontal


Unilab(Shanghai) Co.,Ltd.
Report No. : UL41320150312CE/FCC003-1                                            Page 14 of 14




   Test mode:       Data exchange by USB cable               Antenna Polarity:    Vertical




                APPENDIX 1         PHOTOGRAPHS OF TEST SETUP

Please refer to the file named “N72 WXYZ_Part15B Setup Photos”.


                       APPENDIX 2       PHOTOGRAPHS OF EUT

Please refer to the files named “N72 WXYZ _EUT External Photos” and “N72 WXYZ _EUT
Internal Photos”.

                                 ----End of the report----



Document Created: 2015-08-13 11:45:52
Document Modified: 2015-08-13 11:45:52