User Manual

FCC ID: SWX-UFOLT

Users Manual

Download: PDF
FCCID_3375564

8-Port GPON Optical Line
Terminal with SFP+
Model: UF-OLT


Introduction
Thank you for purchasing the Ubiquiti Networks® U®Fiber OLT.
This Quick Start Guide is designed to guide you through
installation and also includes warranty terms.

Package Contents




                                         U Fiber OLT




 Mounting Brackets           Bracket Screws           Mounting Screws                Cage Nuts
     (Qty. 2)                    (Qty. 8)                (Qty. 4)                     (Qty. 4)




                                                                                8-Port GPON Optical Line
                                                                                Terminal with SFP+
                                                                                Model: UF-OLT




     GPON SFP                  Power Cord                Rubber Feet          Quick Start
    Transceiver                                            (Qty. 4)             Guide
    (UF-GP-B+)

TERMS OF USE: All Ethernet cabling runs must use CAT5 (or above). It is the customer’s
responsibility to follow local country regulations, including operation within legal frequency
channels, output power, indoor cabling requirements, and Dynamic Frequency Selection
(DFS) requirements.


System Requirements
• Linux, Mac OS X, or Microsoft Windows 7/8/10
• Web Browser: Google Chrome (Other browsers may have
  limited functionality)

Installation Requirements
• Phillips screwdriver (for rack- or wall-mounting)
• Standard-sized, 19" wide rack with a minimum of 1U height
  available (for rack-mounting)
• Compatible PON SFP and SFP+ transceivers with appropriate
  fiber optic cabling. For information about compatible fiber
  transceivers, visit: community.ubnt.com/edgemax


Hardware Overview
Front Panel Ports
                 GPON Ports              SFP+         MGMT
                (PON1-PON8)              Ports         Port




                                       Console Port            Reset
                                                              Button

    Interface        Description
   GPON Ports         Gigabit Passive Optical Network ports
 (PON 1-PON 8)        support up to 128 clients on each port.

                      Hot-swappable SFP+ ports support 1G
   SFP+ Ports
                      or 10G connections.

                      10/100/1000 Ethernet port used for
   MGMT Port
                      out‑of‑band management.

                      RJ45 serial console port for Command
                      Line Interface (CLI) management. Use an
                      RJ45‑to-DB9, serial console cable, also
                      known as a rollover cable, to connect the
                      Console port to your computer. (If your
                      computer does not have a DB9 port,
                      then you will also need a DB9 adapter.)
  Console Port        Then configure the following settings
                      as needed:
                      •   Baud rate 57600
                      •   Data bits 8
                      •   Parity NONE
                      •   Stop bits 1
                      •   Flow control NONE


 Interface     Description
               There are two methods to reset the
               U Fiber OLT to factory defaults:
               • Runtime reset (recommended) The
                 U Fiber OLT should be running after
                 bootup is complete. Press and hold
                 the Reset button for about 10 seconds
                 until the MGMT LED starts flashing and
                 then becomes solidly lit. After a few
                 seconds, the LED will turn off, and the
                 U Fiber OLT will automatically reboot.

                       Note: To press the Reset button,
Reset Button           insert a straightened paper
                       clip (or similar object) into the
                       hole shown above. Do not use
                       an object that can break and
                       become lodged in the hole.
               • Power-on reset Disconnect the Power
                 Cord from the U Fiber OLT. Press
                 and hold the Reset button while
                 connecting the Power Cord to the
                 U Fiber OLT. Keep holding the button
                 until the MGMT LED starts flashing
                 and then stops flashing after a few
                 seconds.


Front Panel LEDs
  System                         PON (1-8)    SFP+ (1-2)




                                                        MGMT


    LED       State              Status
              Blue/Flashing      Initializing/Booting Up
  System
              White              Ready for Use

              Off                No Link
 PON 1-8
              White/Flashing     GPON Link/Activity

              Off                No Link

 SFP+ (1-2)   Green/Flashing     1G Link/Activity

              White/Flashing     10G Link/Activity

              Off                No Link

  MGMT        Amber/Flashing     10/100 Link/Activity

              Green/Flashing     1000 Link/Activity




                      *640-00269-04*
                         640-00269-04


Back Panel




                                         AC/DC PSU        PSU 2
         Fans                             Module        Module Bay


Side Panels




                                    Ventilation Holes
                Ventilation Holes




    WARNING: FAILURE TO PROVIDE PROPER VENTILATION
    MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF
    CLEARANCE NEXT TO THE FANS AND VENTILATION
    HOLES FOR ADEQUATE AIRFLOW.


Hardware Installation
The U Fiber OLT can be placed on a horizontal surface,
mounted on a wall, or mounted in a rack.
1. Attach the Mounting Brackets to the U Fiber OLT using the
   eight Bracket Screws.




2. Attach the U Fiber OLT to the rack using the four Mounting
   Screws. (If the rack has square slots, then use the Cage Nuts
   with the Mounting Screws.)


3. Connect the Power Cord to the AC/DC PSU Module.




4. Connect the other end of the Power Cord to a power outlet.


Connecting PON
1. Remove the protective plug covering a PON port.
2. Insert the GPON SFP Transceiver into the PON port.




3. Connect a fiber optic cable to the GPON SFP Transceiver.
   Then connect the other end of the cable to a Passive
   Optical Splitter (POS).




4. Repeat steps 1-3 to connect additional PON ports.
     Note: One GPON SFP transceiver (model UF-GP-B+) is
     included. Use compatible PON SFP transceivers with the
     appropriate fiber optic cabling at each PON port.


Connecting SFP+
1. Remove the protective plug covering an SFP+ port.
2. Insert a compatible SFP transceiver into the SFP+ port.




                                                 M
                                                 D
                                             D
                           M
                           m 2
                            K
                             n CS
                              0
                              0
                                1 /M
                                 3
                                  1 S
                                   xR s
                                     /m pb
                                       n M
                                        0 0
                                         5 0
                                          5 0
                                           1 1
                                            xT




3. Connect the fiber optic cable to the SFP transceiver. Then
   connect the other end of the cable to an SFP device.


Accessing the Configuration Interface
1. Connect an Ethernet cable from your computer to the
   MGMT port on the U Fiber OLT.




2. Configure the Ethernet adapter on your host system with a
   static IP address on the 192.168.1.x subnet.
3. Launch your web browser. Type https://192.168.1.1 in the
   address field. Press enter (PC) or return (Mac).
4. The login screen will appear. Enter ubnt in the Username
   and Password fields. Read the Ubiquiti License Agreement,
   and check the box next to I agree to the terms of this License
   Agreement to accept it. Click Login.




The U Fiber Configuration Interface will appear, allowing you to
customize your settings as needed.


Installing UNMS™
The Ubiquiti Network Management System (UNMS) is a
Linux-based controller software used to centrally manage the
U Fiber OLT and U Fiber Nano G clients.




For the latest UNMS version and installation guide, visit:
www.ubnt.com/software


Specifications
                            U Fiber OLT
Dimensions                                    442.4 x 285.6 x 43.7 mm
                                                (17.42 x 11.24 x 1.72")
Weight
   Without Mount Brackets                            4.400 kg (9.70 lb)
   With Mount Brackets                               4.495 kg (9.91 lb)
Max. Power Consumption              40W (Excluding SFP Transceivers)
Power Method                               110 - 240VAC Modular PSU
Power Supply                     (1) Hot-Swappable AC/DC 100W PSU
                                                         (Included)
Supported Voltage Range                       AC Input: 100 to 240VAC
Button                                                            Reset
Processor                           MIPS 1004Kc 880 MHz Dual-Core
System Memory                             512 MB DDR3, 512 MB NAND
LEDs
   System                                                       Status
   PON Data Ports                                         Link/Activity
   SFP+ Data Ports                                        Link/Activity
   RJ45 (MGMT) Port                                       Link/Activity
Interfaces
    Data Ports                        (8) GPON Ports (2.488 Gbps TX/
                                             1.244 Gbps RX per Port)
                                               (2) 1G/10G SFP+ Ports
    Serial Console Port                         (1) RJ45 Ethernet Port
                                                    (1) RJ45 Serial Port
Certifications                                              CE, FCC, IC
Rackmount                                                           Yes
Operating Temperature                        -10 to 45° C (14 to 113° F)
Operating Humidity                           10 - 90% Noncondensing
GPON SFP OLT Transceiver                    Single Fiber, SM SC, 20 km,
(UF-GP-B+ )                                  1490 nm TX/1310 nm RX,
                                                 ITU-T G984.2 Class B+


Safety Notices
1.   Read, follow, and keep these instructions.
2.   Heed all warnings.
3.   Only use attachments/accessories specified by the manufacturer.
          WARNING: Do not use this product in location that can
          be submerged by water.
          WARNING: Avoid using this product during an electrical
          storm. There may be a remote risk of electric shock from
          lightning.
          WARNING: CLASS 1 LASER PRODUCT - Do not look into
          the ends of the fiber optic cable or SFP modules while
          converters are powered.

Electrical Safety Information
1.   Compliance is required with respect to voltage, frequency, and current
     requirements indicated on the manufacturer’s label. Connection to a
     different power source than those specified may result in improper
     operation, damage to the equipment or pose a fire hazard if the
     limitations are not followed.
2.   There are no operator serviceable parts inside this equipment. Service
     should be provided only by a qualified service technician.
3.   This equipment is provided with a detachable power cord which has
     an integral safety ground wire intended for connection to a grounded
     safety outlet.
     a.    Do not substitute the power cord with one that is not the provided
           approved type. Never use an adapter plug to connect to a 2-wire
           outlet as this will defeat the continuity of the grounding wire.
     b.    The equipment requires the use of the ground wire as a part of the
           safety certification, modification or misuse can provide a shock
           hazard that can result in serious injury or death.
     c.    Contact a qualified electrician or the manufacturer if there
           are questions about the installation prior to connecting the
           equipment.
     d.    Protective earthing is provided by Listed AC adapter. Building
           installation shall provide appropriate short-circuit backup
           protection.
     e.    Protective bonding must be installed in accordance with local
           national wiring rules and regulations.


Limited Warranty
UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) warrants that the
product(s) furnished hereunder (the “Product(s)”) shall be free from defects
in material and workmanship for a period of one (1) year from the date
of shipment by UBIQUITI NETWORKS under normal use and operation.
UBIQUITI NETWORKS’ sole and exclusive obligation and liability under
the foregoing warranty shall be for UBIQUITI NETWORKS, at its discretion,
to repair or replace any Product that fails to conform to the above
warranty during the above warranty period. The expense of removal and
reinstallation of any Product is not included in this warranty. The warranty
period of any repaired or replaced Product shall not extend beyond its
original term.

Warranty Conditions
The above warranty does not apply if the Product:
(I)    has been modified and/or altered, or an addition made thereto,
       except by Ubiquiti Networks, or Ubiquiti Networks’ authorized
       representatives, or as approved by Ubiquiti Networks in writing;
(II)   has been painted, rebranded or physically modified in any way;
(III) has been damaged due to errors or defects in cabling;
(IV) has been subjected to misuse, abuse, negligence, abnormal physical,
       electromagnetic or electrical stress, including lightning strikes, or
       accident;
(V) has been damaged or impaired as a result of using third party
       firmware;
(VI) has no original Ubiquiti MAC label, or is missing any other original
       Ubiquiti label(s); or
(VII) has not been received by Ubiquiti within 30 days of issuance of
       the RMA.
In addition, the above warranty shall apply only if: the product has been
properly installed and used at all times in accordance, and in all material
respects, with the applicable Product documentation; all Ethernet cabling
runs use CAT5 (or above), and for outdoor installations, shielded Ethernet
cabling is used, and for indoor installations, indoor cabling requirements
are followed.

Returns
No Products will be accepted for replacement or repair without obtaining
a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS
during the warranty period, and the Products being received at UBIQUITI
NETWORKS’ facility freight prepaid in accordance with the RMA process of
UBIQUITI NETWORKS. Products returned without an RMA number will not
be processed and will be returned freight collect or subject to disposal.
Information on the RMA process and obtaining an RMA number can be
found at: www.ubnt.com/support/warranty


Disclaimer
EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, UBIQUITI
NETWORKS, ITS AFFILIATES, AND ITS AND THEIR THIRD PARTY DATA, SERVICE,
SOFTWARE AND HARDWARE PROVIDERS HEREBY DISCLAIM AND MAKE NO
OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS, IMPLIED
OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS,
GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY
OF SERVICE OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF
VIRUSES, QUIET ENJOYMENT, FITNESS FOR A PARTICULAR PURPOSE AND
NON-INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE
OF DEALING, USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH
PRODUCTS AND SERVICES. BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI
NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYER’S EQUIPMENT
OR THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES, INCLUDING
THE INTERNET, AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT
TO LIMITATIONS, INTERRUPTIONS, DELAYS, CANCELLATIONS AND OTHER
PROBLEMS INHERENT IN THE USE OF COMMUNICATIONS FACILITIES. UBIQUITI
NETWORKS, ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS
ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS, DELAYS, CANCELLATIONS,
DELIVERY FAILURES, DATA LOSS, CONTENT CORRUPTION, PACKET LOSS, OR
OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING. In addition,
UBIQUITI NETWORKS does not warrant that the operation of the Products
will be error-free or that operation will be uninterrupted. In no event shall
UBIQUITI NETWORKS be responsible for damages or claims of any nature
or description relating to system performance, including coverage, buyer’s
selection of products (including the Products) for buyer’s application and/or
failure of products (including the Products) to meet government or regulatory
requirements.
Limitation of Liability
EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL
UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR
DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES
(INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS), ARISING OUT
OF THE USE, INABILITY TO USE, OR THE RESULTS OF USE OF THE PRODUCT,
WHETHER BASED IN WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY,
AND WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Note
Some countries, states and provinces do not allow exclusions of implied
warranties or conditions, so the above exclusion may not apply to you. You may
have other rights that vary from country to country, state to state, or province
to province. Some countries, states and provinces do not allow the exclusion
or limitation of liability for incidental or consequential damages, so the above
limitation may not apply to you. EXCEPT TO THE EXTENT ALLOWED BY LOCAL
LAW, THESE WARRANTY TERMS DO NOT EXCLUDE, RESTRICT OR MODIFY, AND
ARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICABLE TO
THE LICENSE OF ANY SOFTWARE (EMBEDDED IN THE PRODUCT) TO YOU. The
United Nations Convention on Contracts for the International Sale of Goods
shall not apply to any transactions regarding the sale of the Products.


Compliance
FCC
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1.   This device may not cause harmful interference, and
2.   This device must accept any interference received, including
     interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operations of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
This radio transmitter FCC ID: SWX-UFOLT has been approved by FCC.
Industry Canada
CAN ICES-3(A)/NMB-3(A)
This Class A digital apparatus complies with Canadian CAN ICES-003.
To reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that permitted for successful
communication.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
1.   This device may not cause interference, and
2.   This device must accept any interference, including interference that
     may cause undesired operation of the device.
This radio transmitter (IC: 6545A-UFOLT) has been approved by Industry
Canada.


CAN ICES-3(A)/NMB-3(A)
Cet appareil numérique de la classe A est conforme à la norme NMB-003
du Canada.
Pour réduire le risque d’interférence aux autres utilisateurs, le type
d’antenne et son gain doivent être choisies de façon que la puissance
isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
pour une communication réussie.
Cet appareil est conforme à la norme RSS Industrie Canada exempts de
licence norme(s). Son fonctionnement est soumis aux deux conditions
suivantes:
1.   Cet appareil ne peut pas provoquer d’interférences et
2.   Cet appareil doit accepter toute interférence, y compris les
     interférences qui peuvent causer un mauvais fonctionnement du
     dispositif.
Cet émetteur radio (IC: 6545A-UFOLT) a été approuvée par Industrie
Canada pour l’exploitation avec l’antenne types énumérés ci-dessous avec
le gain maximal admissible et requis l’impédance de l’antenne pour chaque
type d’antenne indiqué. Types d’antenne non inclus dans cette liste, ayant
un gain supérieur au gain maximal indiqué pour ce type, sont strictement
interdits pour une utilisation avec cet appareil.

RF Exposure Warning
The antennas used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be
located or operating in conjunction with any other antenna or transmitter.
Les antennes utilisées pour ce transmetteur doivent être installé en
considérant une distance de séparation de toute personnes d’au moins
20 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre
antenne ou transmetteur.

Australia and New Zealand
         Warning: This is a Class A product. In a domestic environment this
         product may cause radio interference in which case the user may
         be required to take adequate measures.

CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.


RoHS/WEEE Compliance Statement



English
European Directive 2012/19/EU requires that the equipment bearing
this symbol on the product and/or its packaging must not be disposed
of with unsorted municipal waste. The symbol indicates that this
product should be disposed of separately from regular household waste
streams. It is your responsibility to dispose of this and other electric and
electronic equipment via designated collection facilities appointed by the
government or local authorities. Correct disposal and recycling will help
prevent potential negative consequences to the environment and human
health. For more detailed information about the disposal of your old
equipment, please contact your local authorities, waste disposal service, or
the shop where you purchased the product.

Deutsch
Die Europäische Richtlinie 2012/19/EU verlangt, dass technische
Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem
Symbol versehen ist, nicht zusammen mit unsortiertem Gemeindeabfall
entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt
von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es
liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische
und elektronische Geräte über die dafür zuständigen und von der
Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu
entsorgen. Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei,
potentielle negative Folgen für Umwelt und die menschliche Gesundheit
zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer
Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder
städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das
Produkt erworben haben.


Español
La Directiva 2012/19/UE exige que los equipos que lleven este símbolo en
el propio aparato y/o en su embalaje no deben eliminarse junto con otros
residuos urbanos no seleccionados. El símbolo indica que el producto
en cuestión debe separarse de los residuos domésticos convencionales
con vistas a su eliminación. Es responsabilidad suya desechar este y
cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos
de recogida que ponen a su disposición el gobierno y las autoridades
locales. Al desechar y reciclar correctamente estos aparatos estará
contribuyendo a evitar posibles consecuencias negativas para el medio
ambiente y la salud de las personas. Si desea obtener información más
detallada sobre la eliminación segura de su aparato usado, consulte a las
autoridades locales, al servicio de recogida y eliminación de residuos de su
zona o pregunte en la tienda donde adquirió el producto.

Français
La directive européenne 2012/19/UE exige que l’équipement sur lequel
est apposé ce symbole sur le produit et/ou son emballage ne soit pas jeté
avec les autres ordures ménagères. Ce symbole indique que le produit
doit être éliminé dans un circuit distinct de celui pour les déchets des
ménages. Il est de votre responsabilité de jeter ce matériel ainsi que tout
autre matériel électrique ou électronique par les moyens de collecte
indiqués par le gouvernement et les pouvoirs publics des collectivités
territoriales. L’élimination et le recyclage en bonne et due forme ont pour
but de lutter contre l’impact néfaste potentiel de ce type de produits
sur l’environnement et la santé publique. Pour plus d’informations sur le
mode d’élimination de votre ancien équipement, veuillez prendre contact
avec les pouvoirs publics locaux, le service de traitement des déchets, ou
l’endroit où vous avez acheté le produit.

Italiano
La direttiva europea 2012/19/UE richiede che le apparecchiature
contrassegnate con questo simbolo sul prodotto e/o sull’imballaggio non
siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica
che questo prodotto non deve essere smaltito insieme ai normali rifiuti
domestici. È responsabilità del proprietario smaltire sia questi prodotti sia
le altre apparecchiature elettriche ed elettroniche mediante le specifiche
strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il
corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze
potenzialmente negative per l’ambiente e per la salute dell’essere umano.
Per ricevere informazioni più dettagliate circa lo smaltimento delle vecchie
apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti
pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel
quale avete acquistato il prodotto.


Declaration of Conformity
Česky         UBIQUITI NETWORKS tímto prohlašuje, že toto UBIQUITI
[Czech]       NETWORKS zařízení, je ve shodě se základními požadavky a dalšími
              příslušnými ustanoveními směrnice 1999/5/ES.
Dansk         Hermed, UBIQUITI NETWORKS, erklærer at denne UBIQUITI
[Danish]      NETWORKS enhed, er i overensstemmelse med de væsentlige krav
              og øvrige relevante krav i direktiv 1999/5/EF.
Nederlands    Hierbij verklaart UBIQUITI NETWORKS, dat deze UBIQUITI
[Dutch]       NETWORKS apparaat, in overeenstemming is met de essentiële
              eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
English       Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI
              NETWORKS device, is in compliance with the essential requirements
              and other relevant provisions of Directive 1999/5/EC.
Eesti         Käesolevaga UBIQUITI NETWORKS kinnitab, et antud UBIQUITI
[Estonian]    NETWORKS seade, on vastavus olulistele nõuetele ja teistele
              asjakohastele sätetele direktiivi 1999/5/EÜ.
Suomi         Täten UBIQUITI NETWORKS vakuuttaa, että tämä UBIQUITI
[Finnish]     NETWORKS laite, on yhdenmukainen olennaisten vaatimusten ja
              muiden sitä koskevien direktiivin 1999/5/EY.

Français      Par la présente UBIQUITI NETWORKS déclare que l’appareil
[French]      UBIQUITI NETWORKS, est conforme aux exigences essentielles et
              aux autres dispositions pertinentes de la directive 1999/5/CE.
Deutsch       Hiermit erklärt UBIQUITI NETWORKS, dass sich dieses UBIQUITI
[German]      NETWORKS Gerät, in Übereinstimmung mit den grundlegenden
              Anforderungen und den anderen relevanten Vorschriften der
              Richtlinie 1999/5/EG befindet.
Ελληνική      Δια του παρόντος, UBIQUITI NETWORKS, δηλώνει ότι αυτή η
[Greek]       συσκευή UBIQUITI NETWORKS, είναι σε συμμόρφωση με τις
              βασικές απαιτήσεις και τις λοιπές σχετικές διατάξεις της οδηγίας
              1995/5/ΕΚ.
Magyar        Ezennel UBIQUITI NETWORKS kijelenti, hogy ez a UBIQUITI
[Hungarian]   NETWORKS készülék megfelel az alapvető követelményeknek és
              más vonatkozó 1999/5/EK irányelv rendelkezéseit.
Íslenska      Hér, UBIQUITI NETWORKS, því yfir að þetta UBIQUITI NETWORKS
[Icelandic]   tæki er í samræmi við grunnkröfur og önnur viðeigandi ákvæði
              tilskipun 1999/5/EB.
Italiano      Con la presente, UBIQUITI NETWORKS, dichiara che questo
[Italian]     dispositivo UBIQUITI NETWORKS, è conforme ai requisiti essenziali
              ed alle altre disposizioni pertinenti della direttiva 1999/5/CE.
Latviski      Ar šo, UBIQUITI NETWORKS, deklarē, ka UBIQUITI NETWORKS
[Latvian]     ierīce, ir saskaņā ar būtiskajām prasībām un citiem attiecīgiem
              noteikumiem Direktīvā 1999/5/EK.


Lietuviškai    UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS
[Lithuanian]   įrenginys atitinka esminius reikalavimus ir kitas 1999/5/EB
               Direktyvos nuostatas.
Malti          Hawnhekk, UBIQUITI NETWORKS, tiddikjara li dan il-mezz
[Maltese]      UBIQUITI NETWORKS huwa konformi mar-rekwiżiti essenzjali u
               dispożizzjonijiet rilevanti oħrajn ta ‘Direttiva 1999/5/KE.
Norsk          Herved UBIQUITI NETWORKS, erklærer at denne UBIQUITI
[Norwegian]    NETWORKS enheten, er i samsvar med de grunnleggende kravene
               og andre relevante bestemmelser i direktiv 1999/5/EF.
Polski         Niniejszym, Ubiquiti Networks, oświadcza, że ​​urządzenie UBIQUITI
[Polish]       NETWORKS, jest zgodny z zasadniczymi wymaganiami oraz
               pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/WE.
Português      UBIQUITI NETWORKS declara que este dispositivo UBIQUITI
[Portuguese]   NETWORKS, está conforme com os requisitos essenciais e outras
               disposições da Directiva 1999/5/CE.
Română         Prin prezenta, UBIQUITI NETWORKS declară că acest dispozitiv
[Romanian]     UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și
               alte prevederi relevante ale Directivei 1999/5/CE.
Slovensky      Týmto UBIQUITI NETWORKS, prehlasuje, že toto UBIQUITI
[Slovak]       NETWORKS zariadenie, je v súlade so základnými požiadavkami a
               ďalšími relevantnými ustanoveniami smernice 1999/5/ES.
Español        Por medio de la presente UBIQUITI NETWORKS declara que este
[Spanish]      dispositivo UBIQUITI NETWORKS, cumple con los requisitos
               esenciales y cualesquiera otras disposiciones aplicables o exigibles
               de la Directiva 1999/5/CE.
Svenska        Härmed UBIQUITI NETWORKS, intygar att denna UBIQUITI
[Swedish]      NETWORKS enhet är i överensstämmelse med de väsentliga
               egenskapskrav och övriga relevanta bestämmelser som framgår
               av direktiv 1999/5/EG.


Online Resources
Support help.ubnt.com
Community community.ubnt.com
Downloads downloads.ubnt.com


                             www.ubnt.com




©2017 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks,
the Ubiquiti U logo, the Ubiquiti beam logo, U Fiber, and UNMS are
trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United
States and in other countries. All other trademarks are the property of their
respective owners.                                                                AJPH042517



Document Created: 2017-04-27 14:39:57
Document Modified: 2017-04-27 14:39:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC