MPE

FCC ID: SWX-UAP

RF Exposure Info

Download: PDF
FCCID_1390401

       § 15.247(b)     RF Exposure

RF Exposure Requirements:      §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the
                               provisions of this section shall be operated in a manner that ensures that
                               the public is not exposed to radio frequency energy levels in excess of
                               the Commission’s guidelines.

RF Radiation Exposure Limit:   §1.1310: As specified in this section, the Maximum Permissible
                               Exposure (MPE) Limit shall be used to evaluate the environmental
                               impact of human exposure to radiofrequency (RF) radiation as
                               specified in Sec. 1.1307(b), except in the case of portable devices
                               which shall be evaluated according to the provisions of Sec. 2.1093 of
                               this chapter.

               MPE Limit Calculation: EUT’s operating frequencies @ 2412 - 2462 MHz; highest
               conducted power = 29.68dBm (peak) therefore, Limit for Uncontrolled exposure: 1
               mW/cm2 or 10 W/m2

               EUT maximum antenna gain = 4 dBi.

               Equation from page 18 of OET 65, Edition 97-01

                       S = PG / 4R2     or      R = √PG / 4S

               where, S = Power Density (1 mW/cm2)
                      P = Power Input to antenna (928.966mW)
                      G = Antenna Gain (2.51 numeric)

               S = (928.96*2.51/ 4*3.14*20.02) = (2333.46 / 5024) = 0.46 mW/cm2 @ 20cm separation



Document Created: 2010-12-10 09:01:36
Document Modified: 2010-12-10 09:01:36