Part 15.407 UNII 3

FCC ID: SWX-R5M

Test Report

Download: PDF
FCCID_2598967

                                                   Test Report
                                        Prepared for: Ubiquiti Networks, Inc

                                                     Model: RM5

                                               Description: Rocket M5


                                                  FCC ID: SWX-R5M

                                                          To

                                                   FCC Part 15.407

                                             Date of Issue: April 24, 2015



On the behalf of the applicant:           Ubiquiti Networks, Inc
                                          91 E. Tasman Drive
                                          San Jose, CA 95134

Attention of:                             Michael Taylor, Compliance Manager
                                          Ph: (408) 942-3085
                                          E-mail: compliance@ubnt.com


                                                   Prepared By
                                             Compliance Testing, LLC
                                                1724 S. Nevada Way
                                                  Mesa, AZ 85204
                                     (480) 926-3100 phone / (480) 926-3598 fax
                                            www.compliancetesting.com
                                               Project No: p14a0023




                                                                         Alex Macon
                                                                         Project Test Engineer


         This report may not be reproduced, except in full, without written permission from Compliance Testing.
                              All results contained herein relate only to the sample tested.




                                                                          p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                      Page 1 of 22


Test Report Revision History

  Revision      Date             Revised By    Reason for Revision

     1.0        April 17, 2015   Alex Macon    Original Document
                                               Added Band Edge Table to Annex B.
     2.0        April 22, 2015   Alex Macon
                                               Updated all power tables with correct data rates.
     3.0        April 23, 2015   Amanda Reed   Corrected FCC ID on page 7

     4.0        April 24, 2015   Alex Macon    Corrected limits in Annex A tables




                                                    p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                Page 2 of 22


                                 Table of Contents

Description                                                              Page

Standard Test Conditions Engineering Practices                              6
Test Results Summary                                                        9
Peak Output Power                                                         10
Transmitter Power Spectral Density (PSD)                                  12
Undesirable Emissions                                                     14
Undesirable Emissions Radiated                                            15
Occupied Bandwidth                                                        17
Frequency Stability                                                       18
RF Exposure                                                               19
A/C Powerline Conducted Emission                                          21
Test Equipment Utilized                                                   22




                                                     p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                 Page 3 of 22


                                                         ILAC / A2LA


Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard ISO/IEC
17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory
quality management system (refer to the joint ISO-ILAC-IAF Communiqué dated January 2009).

The tests results contained within this test report all fall within our scope of accreditation, unless noted below.

Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation.

Testing Certificate Number: 2152.01




FCC Site Reg. #349717

IC Site Reg. #2044A-2


       Non-accredited tests contained in this report:

       N/A




                                                                               p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                           Page 4 of 22


The applicant has been cautioned as to the following


15.21 - Information to User

The user’s manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

15.27(a) - Special Accessories

Equipment marked to a consumer must be capable of complying with the necessary regulations in the configuration in
which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are
required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment
must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging
the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of
ensuring that the special accessories are provided to the consumer without an additional charge.

Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization
or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in § 2.909 of
this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such
devices shall include appropriate instructions on the first page of text concerned with the installation of the device that
these special accessories must be used with the device. It is the responsibility of the user to use the needed special
accessories supplied with the equipment.




                                                                             p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                         Page 5 of 22


Standard Test Conditions Engineering Practices

Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with C63.10-2013 and unless otherwise indicated in the specific measurement results, the ambient
temperature of the actual EUT was maintained within the range of 10° to 40°C (50° to 104°F) unless the particular
equipment requirements specified testing over a different temperature range. Also, unless otherwise indicated, the
humidity levels were in the range of 10% to 90% relative humidity.

Measurement results, unless otherwise noted, are worst-case measurements.

                                               Environmental Conditions
                               Temperature             Humidity                 Pressure
                                  (ºC)                   (%)                     (mbar)
                                20.4 – 21.5            35.6 – 43.5           972.3 – 976.4



EUT Operation during Tests

The EUT was configured to run in a continuous data stream using ART software through a POE adaptor and Ethernet
connection.

EUT Description
Model: 11N - RM5
Description: Rocket M5
Firmware: N/A
Software: N/A
Serial Number: N/A
Additional Information: The EUT is a 2x2 MIMO 802.11n radio




                                                                             p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                         Page 6 of 22


EUT Specifications

               EUT Specifications                 15.407

               Equipment Code                     NII

               FCC ID                             SWX-R5M

               Model(s)Tested                     RM5

               Model(s) Covered                   RM5

               Maximum Output Power               20.6

               Frequency Ranges covered           5725-5850MHz

               EUT temperature range              -30°C to 75°C

               Bandwidths                         10/20/30/40 MHz
                                                  6, 9, 12, 18, 24, 36, 48, 54, MCS0, MCS1, MCS2,
               Data Rates
                                                  MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9
               Modulations                        BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM

Antenna List

                Model No.           Manufacturer                  Antenna Type          Peak Gain
               AM-5G-16-120            Ubiquiti                      Sector                 16
               AM-5G-17-90             Ubiquiti                      Sector                 17
               AM-M-V5G-Ti             Ubiquiti                      Sector                 17
               AM-5G19-120             Ubiquiti                      Sector                 19
               AM-5G20-90              Ubiquiti                      Sector                 20
               AM5AC21-60              Ubiquiti                      Sector                 21
                AM-V6G-Ti              Ubiquiti                      Sector                 21
               AM-5AC22-45             Ubiquiti                      Sector                 22
                 RD-5G30               Ubiquiti                       Dish                  30
               RD-5G31-AC              Ubiquiti                       Dish                  31
                 RD-5G34               Ubiquiti                       Dish                  34
                AMO-5G13               Ubiquiti                      Omni                   13
                AMO-5G10               Ubiquiti                      Omni                   10




                                                                         p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 7 of 22


15.203: Antenna Requirement:

                                     The antenna is permanently attached to the EUT

                                     The antenna uses a unique coupling

                                 X   The EUT must be professionally installed

                                     The antenna requirement does not apply




           Accessories: None


           Cables: None


           Modifications: None




                                                             p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                         Page 8 of 22


Test Results Summary

                                                                    Pass,
             Specification                 Test Name                                   Comments
                                                                   Fail, N/A
          §15.203                 Antenna Requirements               Pass
          §15.207
                                  Line Conducted Emissions           Pass
          §15.407(b)(6)
          §15.407(a)(3)           Conducted Output Power             Pass

          §15.407(a)(3),(5)       Power Spectral Density             Pass

                                  6dB Occupied Bandwidth
          §15.403(i)
                                                                     Pass
          §15.407(e)
                                  99% Occupied Bandwidth

          §15.407(b)(4)           Undesirable Emissions              Pass
                                  General Field Strength Limits
          §15.205
                                  (Restricted Bands and              Pass
          §15.407(b)(4),(5),(6)
                                  Radiated Emission limits)
          §15.407(g)              Frequency Stability                Pass

          §15.407(f)              RF Exposure                        Pass




          References                       Description

          CFR47, Part 15, Subpart B        Unintentional Radiators

          CFR47, Part 15, Subpart C        Intentional Radiators

          CFR47, Part 15, Subpart E        Unlicensed Nation Information Infrastructure Devices (U-NII)

          ANSI C63.10-2013                 American National standard for testing Unlicensed Wireless Devices
                                           Method and Measurements of Radio-Noise Emissions from low-Voltage
          ANSI C63.4-2014
                                           Electrical and Electronic Equipment in the range 9kHz to 40GHz.
                                           General requirements for the Competence of Testing and Calibrations
          ISO/IEC 17025:2005
                                           Laboratories
          KDB 644545 D03                   Guidance for IEEE 802 11ac New Rules

          KDB 789033 D02                   General U-NII Test Procedures New Rules V01

          KDB 926956 D01                   U-NII Transition Plan




                                                                            p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                        Page 9 of 22


Peak Output Power
Engineer: Alex Macon
Test Date: 4/13/15

                                                      Test Requirements

For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation shall not
exceed 1 W. If transmitting antennas of directional gain greater than 6 dBi are used, the maximum conducted output
power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-
to-point U-NII devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi
without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the use of
point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters transmitting the same
information. The operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for
ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-point operations.

                                                        Test Procedure

The RF power was calculated using the spectrum analyzers’ band power function per Method SA-1 from KDB 789033
D02 General U-NII Test Procedures New Rules v01. Measurements were made at the low, mid and high channels of the
band.

The Spectrum analyzer was set to the following:
   a. RBW = 1 MHz
   b. VBW ≥ 3 MHz
   c. Sweep time = auto
   d. Detector = RMS
   e. 100 traces in power averaging mode

                                                          Test Setup


                            EUT                                                                Spectrum
                                                            Attenuator
                                                                                               Analyzer


        NOTE: For all antenna gains greater than 10dBi the output power must be reduced per the tables in
              Annex A.




                                                                                p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                           Page 10 of 22


Test Results: For a 10dBi antenna

                                                                            Total
                                    Data    J3      J4      J3      J4
        Bandwidth    Frequency                                             Summed    Limit   Margin
                                    Rate   Level   Level   Level   Level
                                                                            Power
           MHz          MHz                dBm     dBm     mW       mW      dBm      dBm      dB
            10          5735         6     14.1    16.4    25.7     43.7    18.4      26      -7.6
            10          5800         6     17.3    17.9    53.7     61.7    20.6      26      -5.4
            10          5840         6     16.6    16.3    45.9     42.7    19.5      26      -6.5
            20          5740         6     12.3    15.6    17.0     36.3    17.3      26      -8.7
            20          5800         6     15.8    17.4    37.8     55.0    19.7      26      -6.3
            20          5835         6     11.9    15.2    15.5     33.1    16.9      26      -9.1
            30          5745         6     11.3    12.6    13.5     18.2    15.0      26     -11.0
            30          5800         6     16.7    16.4    46.8     43.7    19.6      26      -6.4
            30          5830         6     12.4    14.6    17.4     28.8    16.6      26      -9.4
            40          5750         f0     9.1    11.1     8.1     12.9    13.2      26     -12.8
            40          5800         f0    15.3    15.8    33.9     38.0    18.6      26      -7.4
            40          5825         f0    12.3    14.2    17.0     26.3    16.4      26      -9.6




                                                                   p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                              Page 11 of 22


Transmitter Power Spectral Density
Engineer: Alex Macon
Test Date: 4/13/15
                                                  Test Requirements

For the band 5.725-5.85 GHz, the maximum power spectral density shall not exceed 30 dBm in any 500 kHz band. If
transmitting antennas of directional gain greater than 6 dBi are used, the maximum power spectral density shall be
reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII
devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without any
corresponding reduction in power spectral density.

                                                    Test Procedure

The Power Spectral Density was measured using the method per SA-1 from KDB 789033 D02 General U-NII Test
Procedures New Rules v01. Measurements were made at the low, mid and high channels of the band. The maximum
PSD was determine by finding the peak value across the carrier bandwidth.

The Spectrum Analyzer was set to the following:

    a.   RBW = 500 KHz.
    b.   VBW ≥ 1500 MHz
    c.   Span 1.5 * BW
    d.   Sweep time = auto
    e.   Detector = RMS
    f.   100 traces in power averaging mode
                                                       Test Setup


                                                                                          Spectrum
                           EUT                          Attenuator
                                                                                          Analyzer




                                                                           p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                      Page 12 of 22


                               Test Results: For a 10dBi antenna

                                                                   Total
                        Data      J3      J4      J3      J4
Bandwidth   Frequency                                             Summed    Limit/500KHz   Margin
                        Rate     Level   Level   Level   Level
                                                                    SD
  MHz         MHz                dBm     dBm      W       W         dBm         dBm          dB
   10         5735       6        5.9     7.5     3.9     5.6        9.8         26         -16.2
   10         5800       6        6.1     6.8     4.1     4.8        9.5         26         -16.5
   10         5840       6        5.4     5.6     3.5     3.6        8.5         26         -17.5
   20         5740       6        0.4     0.8     1.1     1.2        3.6         26         -22.4
   20         5800       6        2.8     3.1     1.9     2.0        6.0         26         -20.0
   20         5835       6        -0.1    1.7     1.0     1.5        3.9         26         -22.1
   30         5745       6        -4.1   -2.1     0.4     0.6        0.0         26         -26.0
   30         5800       6        1.3     2.1     1.3     1.6        4.7         26         -21.3
   30         5830       6        -2.7   -0.5     0.5     0.9        1.5         26         -24.5
   40         5750       f0       -3.9   -4.4     0.4     0.4       -1.1         26         -27.1
   40         5800       f0       1.2     0.3     1.3     1.1        3.8         26         -22.2
   40         5825       f0       0.1    -1.8     1.0     0.7        2.3         26         -23.7




                                                                p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                           Page 13 of 22


Undesirable Emissions Conducted
Engineer: Alex Macon
Test Date: 4/16/15

                                                  Test Requirements

                               Unwanted Emissions that fall Outside Restricted Bands

For transmitters operating in the 5.725-5.85 GHz band: All emissions within the frequency range from the band edge to 10
MHz above or below the band edge shall not exceed an e.i.r.p. of −17 dBm/MHz; for frequencies 10 MHz or greater
above or below the band edge, emissions shall not exceed an e.i.r.p. of −27 dBm/MHz. The emission measurements shall
be performed using a minimum resolution bandwidth of 1 MHz. A lower resolution bandwidth may be employed near the
band edge, when necessary, provided the measured energy is integrated to show the total power over 1 MHz
The provisions of §15.205 apply to intentional radiators operating under this section.
Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in §15.209.

                            For Conducted Unwanted Emissions in the Restricted Bands

For conducted measurements above 1000 MHz, EIRP was determined and then the field strength computed by the
following:
E[dBμV/m] = EIRP[dBm] - 20 log(d[meters]) + 104.77, where E = field strength and d = 3m
E[dBμV/m] = EIRP[dBm] + 95.2, for d = 3 meters.

                                                    Test Procedure

Per KDB 789033 D02 General U-NII Test Procedures New Rules v01 conducted RF port measurements were made in
lieu of radiated. In addition, Cabinet Emissions measurements were performed in a semi-anechoic chamber with the
antenna port terminated by a matching load. See additional section for Radiated Emissions.

The following criteria were addressed:

The Spectrum Analyzer was set to the following for emissions > 1000MHz:
   a. RBW = 1 MHz
   b. VBW ≥ 3 MHz
   c. Detector = Peak.
   d. Sweep time = auto.
   e. Trace mode = max hold.
      1. Note: For emissions where the peak exceeded that of the average 15.209 emission limit the following was
          performed.
   f. RBW = 1 MHz
   g. VBW ≤ RBW/100 (i.e., 10 kHz) but not less than 10 Hz.

For emissions below 1000MHz the Spectrum Analyzer settings were as follows:
    a. RBW = 100 kHz
    b. VBW ≥ 300 kHz
    c. Detector = Peak.
    d. Sweep time = auto.
    e. Trace mode = max hold.

                                                      Test Setup


                           EUT                          Attenuator                      Spectrum
                                                                                        Analyzer


Test Results:           See Annex B: Undesirable Emissions Conducted

                                                                          p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 14 of 22


Undesirable Emissions Radiated
Engineer: Alex Macon
Test Date: 4/17/15

                                                   Test Requirements

The provision of §15.209 were applied. In addition the requirements of §15.205 were also applied.

FCC Part 15 Subpart C Paragraph 15.209(a) Limits

                             Frequency                          Frequency                     Frequency
                               (MHz)                        (microvolts/meter)                  (meter)
                             0.009-0.490                        2400/F(kHz)                         300

                             0.490-1.705                       24000/F(kHz)                         30

                               1.705-30                               30                            30

                                30-88                                 100                           3

                               88-216                                 150                           3

                               216-960                                200                           3

                              Above 960                               500                           3

Remarks: E field strength (dBμV/m) = 20 log E field strength (uV/m)

                                                    Test Procedure

The EUT was setup in accordance with ANSI C63.10. 2013 and tested per KDB 789033. The antenna was replaced with
non-radiating matched load. The EUT is placed on non-conductive platform at a height of 0.8 meters above the ground
plane of the semi-anechoic chambers. The EUT was rotated 360 degrees and the receive antenna raised and lowered to
                                                  th
find the maximum emissions from 30MHz to the 10 harmonic of the fundamental. The EUT was set to the maximum
power level allowed and the low, mid, and high channels were investigated for emissions.

The Spectrum Analyzer was set to the following for emissions > 1000MHz:

    a. (RBW = 1 MHz
    b. VBW ≥ 3 MHz
    c. Detector = Peak.
    d. Sweep time = auto.
    e. Trace mode = max hold.
       1. Note: For emissions where the peak exceeded that of the average 15.209 emission limit the following was
           performed.
    f. RBW = 1 MHz
    g. VBW ≤ RBW/100 (i.e., 10 kHz) but not less than 10Hz

For emissions below 1000MHz the Spectrum Analyzer settings were as follows:

    a.   RBW = 100 kHz
    b.   VBW ≥ 300 kHz
    c.   Detector = Peak.
    d.   Sweep time = auto.
    e.   Trace mode = max hold.
         1. Note: A quasi peak detector was used for emissions where the peak exceeded that of the average 15.209
             emission limits

                                                                            p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                       Page 15 of 22


                                            Test Setup below 1000MHz


                            EUT                    Antenna with              Spectrum
                                                     Preamp                  Analyzer




                                            Test Setup above 1000MHz

                                                      Band
         EUT with                 Antenna                                 Amplifier        Spectrum
                                                      Reject
        matching load                                                                      Analyzer
                                                      Filter




Test Results:           See Annex C: Undesirable Emission Radiated




                                                                       p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                  Page 16 of 22


Occupied Bandwidth
Engineer: Alex Macon
Test Date: 4/13/15
                                                   Test Requirement

Within the 5.725-5.85 GHz band, the minimum 6 dB bandwidth of U-NII devices shall be at least 500 kHz. For purposes
of this subpart the emission bandwidth shall be determined by measuring the width of the signal between two points, one
below the carrier center frequency and one above the carrier center frequency, that are 6 dB down relative to the
maximum level of the modulated carrier. Determination of the emissions bandwidth is based on the use of measurement
instrumentation employing a peak detector function with an instrument resolution bandwidth approximately equal to 1.0
percent of the emission bandwidth of the device under measurement

                                                    Test Procedure

The Spectrum analyzer was set to the following parameters
   a. RBW = 100 kHz.
   b. VBW ≥ 300 kHz
   c. Detector = Peak.
   d. Trace mode = max hold.



                                                      Test Setup


                                             EUT                     Spectrum
                                                                     Analyzer




Test Results:           See Annex D: Occupied Bandwidth




                                                                          p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 17 of 22


Frequency Stability
Engineer: Alex Macon
Test Date: 4/16/15

                                                   Test Requirement

Manufacturers of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within
the band of operation under all conditions of normal operation as specified in the user’s manual.

                                                     Test Procedure

    a. The EUT was placed into a temperature chamber and the temperature ranges were set to the manufacturers’
       specifications.
    b. The RF output of the EUT was connected to a spectrum analyzer
    c. The lowest and highest channels of the band were set to transmit
    d. The carrier plots were measured to insure that the 6dB band width remained within the band over the prescribed
       temperature extremes.



                                                       Test Setup



                          Temperature Chamber

                                                                      Spectrum
                                   EUT                                Analyzer




Test Results:           See Annex E: Frequency Stability




                                                                            p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                       Page 18 of 22


RF Exposure
Engineer: Alex Macon
Test Date: 4/17/15

                                                     Requirements

U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and
§2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general
population/uncontrolled” environment. Applications for equipment authorization of devices operating under this section
must contain a statement confirming compliance with these requirements for both fundamental emissions and unwanted
emissions. In addition, systems operating under the provisions of this section shall be operated in a manner that insures
that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines.

                                                    Exposure Limits

At operating frequencies less than or equal to 6 GHz, the limits for maximum permissible exposure (MPE) shall be used to
evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Section 1.1307(b),
except for portable devices as defined in §2.1093 as these evaluations shall be performed according to the SAR
provisions in §2.1093 of this chapter.

MPE Limit Calculations
                        2
Exposure Limit 1mW/cm

Source Based Time Averaged Power Calculation

Average Power Calculations

Average Power = Peak Power * duty-cycle%


          Tuned Frequency            Conducted Peak Output Power            Duty Cycle         Average Power
               (MHz)                            (mW)                            %                  (mW)
                 5800                              115                          100                   115




                                                                            p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                       Page 19 of 22


MPE Evaluation

This is a fixed/mobile device used in uncontrolled /general population exposure environment.


Limits Uncontrolled Exposure       0.3-1.234 MHz                  Limit [mW/cm²] = 100
47 CFR 1.1310                      1.34-30 MHz                    Limit [mW/cm²] = (180/f²)
Table 1, (B)                       30-300 MHz                     Limit [mW/cm²] = 0.2
                                   300-1500 MHz                   Limit [mW/cm²] = f/1500
                                   1500-100,000 MHz               Limit [mW/cm²] = 1.0




Test Data

Test Frequency, MHz                 5800
Power, Conducted, mW (P)            115
Antenna Gain Isotropic              10
Antenna Gain Numeric (G)            10
Antenna Type                        Omni
Distance (R)                        20 cm

                      𝑃∗𝐺
                 𝑆=
                      4𝜋𝑟 2
                          2                                                                      2
Power Density (S) mw/cm                       Power mW (P)       Numeric Gain (G)     Distance (r ) cm
                                                        115                    10                    20

Power Density (S) =                  0.457
Limit =(from above table) =             1.0


Note: Due to out of band emission limitations the highest EIRP occurs with the 10dBi Omni antenna. Therefore
the power density cannot exceed 0.457mW/cm2




                                                                           p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                      Page 20 of 22


A/C Powerline Conducted Emission
Engineer: Mark Sechrist
Test Date: 11/3/14

                                                    Test Procedure

The EUT power cable was connected to a LISN and the monitored output of the LISN was connected to a transient limiter,
which then connected directly to a spectrum analyzer. The conducted emissions from 150 kHz to 30 MHz were measured
and compared to the specification limits.

                                                      Test Setup



                   EUT                                               Transient              Spectrum
                                             LISN
                Power Cable                                           Limiter               Analyzer




Test Results:          See Annex F: A/C Powerline Conducted Emission




                                                                          p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 21 of 22


 Test Equipment Utilized
                                                                                                  Last Cal        Cal Due
      Description           Manufacturer               Model #                 CT Asset #
                                                                                                   Date            Date
Temperature Chamber        Tenney            Tenney Jr                            i00027            NCR            NCR

EMI Receiver               HP                8546A                                i00033           2/26/15        2/26/16

Preamplifier               HP                8447D                                i00055            NCR            NCR

Horn Antenna               EMCO              3116                                 i00085            NCR            NCR

Horn Antenna, Amplified    ARA               DRG-118/A                            i00271            5/8/14         5/8/16
*Horn Antenna,
                           ARA               MWH-1826/B                           i00273            4/9/12       4/9/2015
Amplified
Humidity / Temp Meter      Newport           IBTHX-W-5                            i00282            4/1/15         4/1/16

Spectrum Analyzer          Agilent           E4407B                               i00331           6/13/14        6/13/15

Data Logger                Fluke             Hydra Data Bucket                    i00343           3/24/15        3/24/16

Bi-Log Antenna             Schaffner         CBL 6111D                            i00349           10/8/13        10/8/15

EMI Analyzer               Agilent           E7405A                               i00379            2/5/15         2/5/16
                           Pacific           Mixer Mdl: MD1A
Standard Gain Horn Kit     Millimeter        60 – 90 GHz Horn Mdl: EM             i00394            NCR            NCR
                           Products          90 – 140 GHz Horn Mdl: FM
3 Meter Semi-Anechoic                        3 Meter Semi-Anechoic
                           Panashield                                             i00428          11/26/13       11/26/15
Chamber                                      Chamber
Spectrum Analyzer          Agilent           E4446A                         S/N:MY46180386        10/26/14       10/26/16

Spectrum Analyzer          Agilent           E4448A                         S/N:US42510268        10/23/13       10/23/15

Spectrum Analyzer          Agilent           E4407B                         S/N:SG44210864          1/8/15         1/8/16

Spectrum Analyzer          Agilent           E4448A                         S/N:MY46180566         3/20/15        12/1/16
 *Equipment is under a 30 day calibration extension and Lab Manager’s discretion


 In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the described
 equipment. Prior to testing these components were tested to verify proper operation.



 END OF TEST REPORT




                                                                             p14a0023_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                        Page 22 of 22



Document Created: 2015-04-24 16:25:01
Document Modified: 2015-04-24 16:25:01

© 2024 FCC.report