Test Report RFExp

FCC ID: SWX-R2ACN

RF Exposure Info

Download: PDF
FCCID_3530058

        RF Exposure Evaluation Report                                          Report No. : FA581010-04




                RF Exposure Evaluation Report

                        APPLICANT            : Ubiquiti Networks, Inc.

                        EQUIPMENT            : rocket PRISM AC

                        BRAND NAME           : UBIQUITI

                        MODEL NAME           : R2AC

                        FCC ID               : SWX-R2ACN

                        STANDARD             : 47 CFR Part 2.1091


     We, SPORTON INTERNATIONAL INC., would like to declare that the device has been
     evaluated in accordance with 47 CFR Part 2.1091, and pass the limit. Without written
     approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced
     except in full.




         Reviewed by: Eric Huang / Manager




         Approved by: Jones Tsai / Manager



                             SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.                                          Page Number        : 1 of 7
TEL : 886-3-327-3456                                                Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                                Report Version     : Rev. 01
FCC ID : SWX-R2ACN


            RF Exposure Evaluation Report                                                                                    Report No. : FA581010-04

                                                        Table of Contents
1. ADMINISTRATION DATA ........................................................................................................................... 4
     1.1.     Testing Laboratory ............................................................................................................................. 4
2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 5
3. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 5
4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 6
5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 7
     5.1.     Standalone Power Density Calculation ............................................................................................. 7
     5.2.     Collocated Power Density Calculation ............................................................................................... 7




SPORTON INTERNATIONAL INC.                                                                                    Page Number        : 2 of 7
TEL : 886-3-327-3456                                                                                          Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                                                                          Report Version     : Rev. 01
FCC ID : SWX-R2ACN


        RF Exposure Evaluation Report                                        Report No. : FA581010-04
                                         Revision History
  REPORT NO.         VERSION                        DESCRIPTION                    ISSUED DATE

   FA581010-04       Rev. 01   Initial issue of report                              Aug. 17, 2017




SPORTON INTERNATIONAL INC.                                        Page Number        : 3 of 7
TEL : 886-3-327-3456                                              Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                              Report Version     : Rev. 01
FCC ID : SWX-R2ACN


          RF Exposure Evaluation Report                                           Report No. : FA581010-04
1. Administration Data

1.1. Testing Laboratory
Testing Laboratory
Test Site                    SPORTON INTERNATIONAL INC.
                             No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan
                             City, Taiwan (R.O.C.)
Test Site Location
                             TEL: +886-3-327-3456
                             FAX: +886-3-328-4978


                                                 Applicant
Company Name                 Ubiquiti Networks, Inc.
Address                      685 Third Avenue, 27th Floor New York, New York 10017 USA


                                               Manufacturer
Company Name                 Ubiquiti Networks, Inc.
Address                      685 Third Avenue, 27th Floor New York, New York 10017 USA




SPORTON INTERNATIONAL INC.                                             Page Number        : 4 of 7
TEL : 886-3-327-3456                                                   Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                                   Report Version     : Rev. 01
FCC ID : SWX-R2ACN


         RF Exposure Evaluation Report                                                      Report No. : FA581010-04
2. Description of Equipment Under Test (EUT)
                                         Product Feature & Specification
EUT Type                   rocket PRISM AC
Brand Name                 UBIQUITI
Model Name                 R2AC
FCC ID                        SWX-R2ACN
Wireless Technology and WLAN 2.4GHz Band: 2412 MHz ~ 2462 MHz
Frequency Range               WLAN 5.8GHz Band: 5745 MHz ~ 5825 MHz
Mode                          802.11a/n/ac HT20/VHT10/VHT20/VHT40
                              WLAN 2.4GHz : 10 dBi / 24 dBi
Antenna Gain
                              WLAN 5G Hz : -6 dBi
EUT Stage                     Identical Prototype
Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual
for more detailed description.




3. Maximum RF average output power among production units

General note :
There are two kinds of 2.4GHz WLAN output Power mode on this device :
      (1) When equipped with 10 dBi antenna, the 2.4GHz WLAN maximum output power as follows :
                                  Mode                          Maximum Average Power (dBm)
                              2.4GHz WLAN                                     24.5


      (2) When equipped with 24 dBi antenna, the 2.4GHz WLAN maximum output power as follows :
                                  Mode                          Maximum Average Power (dBm)
                              2.4GHz WLAN                                     11.5




                                  Mode                          Maximum Average Power (dBm)
                              5GHz WLAN                                       24.5




SPORTON INTERNATIONAL INC.                                                       Page Number        : 5 of 7
TEL : 886-3-327-3456                                                             Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                                             Report Version     : Rev. 01
FCC ID : SWX-R2ACN


         RF Exposure Evaluation Report                                                        Report No. : FA581010-04
4. RF Exposure Limit Introduction
According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of

human exposure to radio frequency (RF) radiation as specified in §1.1310.




    The MPE was calculated at 24 cm to show compliance with the power density limit.
    The following formula was used to calculate the Power Density:


                                                           𝐏𝐆
                                                    𝐒=
                                                          𝟒𝛑𝐑𝟐
    Where:
    S = Power Density
    P = Output Power at Antenna Terminals
    G = Gain of Transmit Antenna (linear gain)
    R = Distance from Transmitting Antenna




SPORTON INTERNATIONAL INC.                                                        Page Number        : 6 of 7
TEL : 886-3-327-3456                                                              Report Issued Date : Aug. 17, 2017
FAX : 886-3-328-4978                                                              Report Version     : Rev. 01
FCC ID : SWX-R2ACN


seorron cas. _RF Exposure Evaluation Report                                                         Report No. : FA581010—04
  5. Radio Frequency Radiation Exposure Evaluation

  5.1. Standalone Power Density Calculation
                                                                                           Power
                                   Antenna Maximum Maximum Maximum |Average                                        Power
                       F'?,?nīŦ'fz’;cy Gain    Power       EIRP       EIRP      EirP       P°pSIY * ;mv'\','/:‘l:,\z) Li
                                     (dBi)    (dBm)      (dBm)       (W)       itorte                              / Limit
    2.4GHz WLAN           2412.0     10.0      24.5      34.500     2818     |2818.383|     0.390        1.000
    2.4GHz WLAN           2412.0     24.0      11.5      35.500     3.548    |3548.134]     0.490        1.000      0.490_
     5GHz WLAN            5745.0     —6.0      24.5      18.500     0071      70.795        0.010        1.000      0.010
  Note: For conservativeness, the lowest frequency of each band is used to determine the MPE limit of that band




  5.2. Collocated Power Density Calculation
                                                                                         PCPc uiL
         Maximum 2.4GHz WLAN                          5GHz WLAN
          Power Density / Limit                   Power Density / Limit
                                                                                                  of
                                                                                       24GHz WLAN + 5GHz WLAN
                  0.490                                   0.010                                 0.500
  Note:
  1. 2.4GHz WLAN and 5GHz WLAN can transmit simultaneously.
  2.X (Power Density / Limit): This is a summation of [{(power density for each transmitter/antenna included in the
     simultaneous transmission)/ (corresponding MPE limit)], for 2.4GHz WLAN + 5GHz WLAN.
  3. Considering the 2.4GHz WLAN module collocation with the 5GHz WLAN of the EIRP performance listed in the table
     above, the aggregated (power density /limit) is smaller than 1, and MPE of 2 collocated transmitters is compliant




  Conclusion:

  According to 47 CFR §2.1091, the RF exposure analysis concludes that the RF Exposure is FCC compliant.




  SPORTON INTERNATIONAL INC.                                                          Page Number        : 7 of 7
  TEL : 886—3—327—3456                                                                Report Issued Date : Aug. 17, 2017
  FAX : 886—3—328—4978                                                                Report Version     : Rev. 01
  FCC ID : SWX—R2ACN



Document Created: 2017-08-21 14:54:30
Document Modified: 2017-08-21 14:54:30

Š 2024 FCC.report