RF Exposure

FCC ID: SWX-NBE2M13

RF Exposure Info

Download: PDF
FCCID_2704670

        RF Exposure Evaluation Report                                       Report No. : FA542937-01




                RF Exposure Evaluation Report

                         APPLICANT           : Ubiquiti Network, Inc

                         EQUIPMENT           : Access Point

                         BRAND NAME          : UBIQUITI

                         MODEL NAME          : NBE-M2-13

                         FCC ID              : SWX-NBE2M13

                         STANDARD            : 47 CFR Part 2.1091


     We, SPORTON INTERNATIONAL INC., would like to declare that the device has been
     evaluated in accordance with 47 CFR Part 2.1091 and pass the limit. Without written
     approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced
     except in full.




     Reviewed by: Eric Huang / Deputy Manager




         Approved by: Jones Tsai / Manager



                             SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.                                       Page Number        : 1 of 5
TEL : 886-3-327-3456                                             Report Issued Date : Aug. 03, 2015
FAX : 886-3-328-4978                                             Report Version     : Rev. 01
FCC ID : SWX-NBE2M13


            RF Exposure Evaluation Report                                                                                    Report No. : FA542937-01

                                                        Table of Contents
1. ADMINISTRATION DATA ........................................................................................................................... 3
     1.1.     Testing Laboratory ............................................................................................................................. 3
2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 3
3. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 3
4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 4
5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 5
     5.1.     Standalone Power Density Calculation ............................................................................................. 5




                                                               Revision History
   REPORT NO.                VERSION                                         DESCRIPTION                                              ISSUED DATE

    FA542937-01                Rev. 01           Initial issue of report                                                              Aug. 03, 2015




SPORTON INTERNATIONAL INC.                                                                                    Page Number        : 2 of 5
TEL : 886-3-327-3456                                                                                          Report Issued Date : Aug. 03, 2015
FAX : 886-3-328-4978                                                                                          Report Version     : Rev. 01
FCC ID : SWX-NBE2M13


            RF Exposure Evaluation Report                                                      Report No. : FA542937-01
1. Administration Data

1.1. Testing Laboratory
                                                    Testing Laboratory
Test Site                         SPORTON INTERNATIONAL INC.
                                  No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City,
                                  Taiwan (R.O.C.)
Test Site Location
                                  TEL: +886-3-327-3456
                                  FAX: +886-3-328-4978

                                                         Applicant
Company Name                     Ubiquiti Network, Inc
Address                          12F, No.105, Song Ren Rd.,SinYi District, Taipei 110,Taiwan

                                                      Manufacturer
Company Name                     Ubiquiti Network, Inc
Address                          12F, No.105, Song Ren Rd.,SinYi District, Taipei 110,Taiwan



2. Description of Equipment Under Test (EUT)
                                             Product Feature & Specification
EUT Type                      Access Point
Brand Name                    UBIQUITI
Model Name                    NBE-M2-13
FCC ID                  SWX-NBE2M13
Wireless Technology and
                        WLAN 2.4GHz Band: 2412 MHz ~ 2462 MHz
Frequency Range
Mode                    802.11g/n (HT5/HT8/HT10/HT20/HT30/HT40)
Antenna Type                  Disc Antenna
EUT Stage                     Production Unit



3. Maximum RF average output power among production units
                                                            IEEE 802.11 Average Power (dBm)
            Band / Mode
                                         5M / 10M             11g 8M              11g 20M                11g 30M
                      Low                 16.50                13.50               13.50                   6.00
     11g             Middle               16.00                12.50               16.00                   4.00
                      High                15.50                 9.00               11.50                   5.00


                                                             IEEE 802.11 Average Power (dBm)
            Band / Mode
                                    HT5 / HT10             HT8            HT20            HT30               HT40
                      Low             17.00               13.50           13.50           4.00               10.50
     11n             Middle           16.00               12.50           16.00           4.00               15.00
                      High            15.50               11.00           11.50           4.00                8.50




SPORTON INTERNATIONAL INC.                                                         Page Number        : 3 of 5
TEL : 886-3-327-3456                                                               Report Issued Date : Aug. 03, 2015
FAX : 886-3-328-4978                                                               Report Version     : Rev. 01
FCC ID : SWX-NBE2M13


         RF Exposure Evaluation Report                                                        Report No. : FA542937-01
4. RF Exposure Limit Introduction
According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of

human exposure to radio frequency (RF) radiation as specified in §1.1310.




    The MPE was calculated at 20 cm to show compliance with the power density limit.
    The following formula was used to calculate the Power Density:


                                                           𝐏𝐆
                                                    𝐒=
                                                          𝟒𝛑𝐑𝟐
    Where:
    S = Power Density
    P = Output Power at Antenna Terminals
    G = Gain of Transmit Antenna (linear gain)
    R = Distance from Transmitting Antenna




SPORTON INTERNATIONAL INC.                                                        Page Number        : 4 of 5
TEL : 886-3-327-3456                                                              Report Issued Date : Aug. 03, 2015
FAX : 886-3-328-4978                                                              Report Version     : Rev. 01
FCC ID : SWX-NBE2M13


         RF Exposure Evaluation Report                                                      Report No. : FA542937-01
5. Radio Frequency Radiation Exposure Evaluation

5.1. Standalone Power Density Calculation

                                                                                                Power
                                    Antenna Maximum Maximum Maximum
                        Frequency                                              Average EIRP Density at          Limit
        Band                          Gain       Power      EIRP       EIRP
                          (MHz)                                                     (mW)        20cm        (mW/cm^2)
                                      (dBi)      (dBm)     (dBm)        (W)
                                                                                              (mW/cm^2)
    2.4GHz WLAN          2412.0      13.00        17.00    30.000     1.000       1000.000      0.199          1.000
Note: For conservativeness, the lowest uplink frequency of each band is used to determine the MPE limit of that band




Conclusion:

According to 47 CFR §2.1091, the RF exposure analysis concludes that the RF Exposure is FCC compliant.




SPORTON INTERNATIONAL INC.                                                       Page Number        : 5 of 5
TEL : 886-3-327-3456                                                             Report Issued Date : Aug. 03, 2015
FAX : 886-3-328-4978                                                             Report Version     : Rev. 01
FCC ID : SWX-NBE2M13



Document Created: 2015-08-03 16:27:36
Document Modified: 2015-08-03 16:27:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC