RF Exposure Report

FCC ID: SWX-M5LD

RF Exposure Info

Download: PDF
FCCID_2340846

                                                                                        Report No.: 1460318R-RFUSP42V00




                   RF Exposure Evaluation declaration



                                    Product Name Acess Point
                                    Model No.             NanoStationLoco M5
                                    FCC ID                SWX-M5LD




                       Applicant Ubiquiti Networks, Inc.
                       Address 12F, No. 105, Song Ren Rd., Sin Yi District,
                                       Taipei 110, Taiwan




                             Date of Receipt                  June 10, 2014
                             Date of Declaration              July 03, 2014
                             Report No.                       1460318R-RFUSP42V00


The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the calibration of the
equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.



                                                          Page: 1 of 3


                                                                            Report No.: 1460318R-RFUSP42V00


1.      RF Exposure Evaluation

1.1.    Limits

        According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
        Frequency Range       Electric Field       Magnetic Field      Power Density        Average Time
                                                                                 2
        (MHz)                 Strength (V/m)       Strength (A/m)      (mW/cm )             (Minutes)
                                    (A) Limits for Occupational/ Control Exposures
               300-1500                  --                  --               F/300                  6
           1500-100,000                  --                  --                  5                   6
                              (B) Limits for General Population/ Uncontrolled Exposures
               300-1500                  --                  --               F/1500                 6
           1500-100,000                  --                  --                  1                   30
        F= Frequency in MHz


       Friis Formula
       Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power
       input to the antenna, through the calculation, we will know the distance r where the MPE limit is
       reached.



1.2.    Test Procedure

         Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
         highest channel individually.
         The temperature and related humidity: 18℃and 78% RH.




                                                 Page: 2 of 3


                                                                          Report No.: 1460318R-RFUSP42V00




1.3.      Test Result of RF Exposure Evaluation

          Product        :        Acess Point
          Test Item      :        RF Exposure Evaluation
          Test Site      :        No.3 OATS



Output Power Into Antenna & RF Exposure Evaluation Distance:
  Peak Power        Antenna Gain        Antenna Gain
                                                                 R (cm)
       (dBm)             (dBi)             (linear)
       18.61                 16             39.81                 20.0



 Output Power to Antenna (mW)             Power Density (mW/cm2)

               72.6106                                0.575083
Power density is lower than the limit (1 mW/cm2).