Hi Dusmantha,

Please see response below and revised Report, Manual, Industry Canada Package and Form 731
attached.

FCC:

  1. The EUT appears to be an 802.11 b/g/n device. It does not appear that the b mode was tested per
      the test report. Please clarify why this mode was not tested.
    EUT operates in only 802.11n mode, the report is correct, please see revised Form 731.
  2. The peak power spectral density limit stated in table 29 (page 107 of121) is wrong. It should be
      adjusted to account for the 24 dBi antenna.
   Please see revised report.
  3. The user manual should include a statement that installation should only be for point-to-point.
   Please see revised manual

IC:
      1.   The SA settings for the 6dB and 99% Occupied bandwidth are incorrect. The 6 dB bandwidth needs to be
           measured with a RBW that is close to 1% of the emissions bandwidth. The 99% bandwidth needs to be
           measured with a RBW that is close to 1% of the selected span without being below 1%.
      Please see revised report.
      2.    Please clarify how the receiver spurs measurements were performed (i.e. conducted or radiated)? It appears
           to have been performed radiated. Were the antenna correction factors and cable loss taken into
           consideration? The limits stated in the standard are in terms of field strength at 3m. However, the SA units
           are in terms of dBm. Please clarify how the determination was made that the emissions seen pass the field
           strength limits. There is also what appears to be a limit line on the plots. Please clarify what this line is.
      Please see revised report.
      3.    The RF evaluation in Annex A of the Technical Brief Cover Sheet should state General Public Use. The
           standard used for evaluation is also incorrect. The RF value should also state 1 mW/cm2.
      Please see revised Annex A.