FCC_Part 1.1310_Rev 3.0.pdf

FCC ID: SWX-BDBAC

RF Exposure Info

Download: PDF
FCCID_4452935

                                                   Test Report
                                       Prepared for: Ubiquiti Networks, Inc

                                              Model: B-DB-AC, Bullet

                                   Description: Dual Band Networking Device

                                                Serial Number: N/A

                                               FCC ID: SWX-BDBAC

                                                         To

                                                 FCC Part 1.1310


                                        Date of Issue: September 10, 2018



On the behalf of the applicant:                  Ubiquiti Networks, Inc
                                                 2580 Orchard Parkway
                                                 San Jose, CA 95131

Attention of:                                    Mark Feil
                                                 Ph: (408)942-3085
                                                 Email: mark.feil@ubnt.com




                                                  Prepared By
                                            Compliance Testing, LLC
                                               1724 S. Nevada Way
                                                 Mesa, AZ 85204
                                    (480) 926-3100 phone / (480) 926-3598 fax
                                           www.compliancetesting.com
                                              Project No: p1790008




                                                                      Poona Saber
                                                                      Project Test Engineer



        This report may not be reproduced, except in full, without written permission from Compliance Testing
                             All results contained herein relate only to the sample tested



                                                                                 p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                                       Page 1 of 6


                                Test Report Revision History

Revision   Date                 Revised By           Reason for Revision

    1.0    January 23, 2018     Poona Saber          Original Document

    2.0    January 31, 2018     Poona Saber          Added a note on page 3
                                                     Changed the maximum power and minimum
    3.0    September 10, 2018   Poona Saber          safe distance based on new power
                                                     measurements




                                                           p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                 Page 2 of 6


                                                 ILAC / A2LA
Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard
ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer joint ISO-ILAC-IAF Communiqué dated
January 2009)

The tests results contained within this test report all fall within our scope of accreditation, unless below

Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation.

Testing Certificate Number: 2152.01




FCC Site Reg. #349717

IC Site Reg. #2044A-2


 Non-accredited tests contained in this report:

 N/A




EUT Description
Model: B-DB-AC, Bullet
Description: Dual Band Networking Device
Firmware: N/A
Software: N/A
Serial Number: N/A
Additional Information: The Bullet AC (Model: B-DB-AC) is a dual band networking device that is
powered over ethernet (passive POE, 24V) and provides an N-type antenna connection. It features dual-
band AC mode operation in 5GHz and 2.4GHz bands, and a dedicated 2.4 GHz WiFi management radio
for convenient device setup.

EUT Operation during Tests
Radio testing has been done conducted and radiated with controlling the device for continuous
modulation transmission on low, middle and high channels with client’s provided commands through
telnet.

Note: Power is brought down one by one for other antennas mathematically so the highest EIRP for 4dBi
antenna would be the same for other antennas as well.




                                                                       p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                             Page 3 of 6


       Source Based Time Averaged Power Calculation


       Average Power calculations

       Average Power = Peak Power * duty-cycle%



       Point to multipoint application

                   Conducted Peak Output      Maximum
Tuned Frequency                                           Duty Cycle              Average Power
                          Power               Tolerance
     (MHz)                                                   (%)                      (mW)
                          (dBm)                 (dB)
     2437                    17.48                2 dB       100                      88.71




       Point to Point application

                   Conducted Peak Output      Maximum
Tuned Frequency                                           Duty Cycle              Average Power
                          Power               Tolerance
     (MHz)                                                   (%)                      (mW)
                          (dBm)                 (dB)
     5735                    23.1                 2 dB       100                      323.59




                                                          p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                Page 4 of 6


MPE Evaluation for Point to Multipoint Application

This is a portable device used in Uncontrolled Exposure environment.

 Limits Uncontrolled Exposure      0.3-1.234 MHz:                Limit [mW/cm²] = 100
 47 CFR 1.1310                     1.34-30 MHz:                  Limit [mW/cm²] = (180/f²)
 Table 1, (B)                      30-300 MHz:                   Limit [mW/cm²] = 0.2
                                   300-1500 MHz:                 Limit [mW/cm²] = f/1500
                                   1500-100,000 MHz              Limit [mW/cm²] = 1.0

Test Data

 Test Frequency, MHz                 2437
 Power, Conducted, mW (P)            88.71
 Antenna Gain Isotropic              13 dBi
 Antenna Gain Numeric (G)            19.95
 Antenna Type                        Omni
 Distance (R)                        20 cm

                     𝑃∗𝐺
                   𝑆=
                     4𝜋𝑟 2
 Power Density (S) mw/cm 2


 Power Density (S) =0.35
 Limit = (from above table) = 1




MPE Evaluation for Point to Point Application

Test Data

 Test Frequency, MHz                 5735
 Power, Conducted, mW (P)            323.59
 Antenna Gain Isotropic              34 dBi
 Antenna Gain Numeric (G)            2511.8
 Antenna Type                        Dish
 Distance (R)                        20 cm

                     𝑃∗𝐺
                   𝑆=
                     4𝜋𝑟 2
 Power Density (S) mw/cm 2


 Power Density (S) =161.7
 Limit = (from above table) = 1




                                                                  p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                        Page 5 of 6


Minimum Safe Distance Evaluation


Since the power density is over the limit the minimum safe distance evaluation is done per below to find
the minimum installation distance for power density being below the limit.

Test Data

 Test Frequency, MHz                  5735
 Power, Conducted, mW (P)             323.59
 Antenna Gain Isotropic               34 dBi
 Antenna Gain Numeric (G)             2511.8
 Antenna Type                         Dish
 Limit (L)                            20 cm

 R=√(PG/4πL)
 Distance (R) cm                               Power mW (P)      Numeric Gain (G)    Limit (L)
 254.38                                        323.59            2511.8              1


The minimum safe distance for point to point application is 254.38 centimeters.




                                                                    p1790008_FCC_Part 1.1310_Rev 3.0
                                                                                          Page 6 of 6



Document Created: 2019-09-21 00:31:30
Document Modified: 2019-09-21 00:31:30

© 2024 FCC.report