Test Report JBP

FCC ID: SWX-ACBLOCO

Test Report

Download: PDF
FCCID_3659134

           FCC Test Report                                                     Report No. : FC741927-02




                             FCC Test Report

                APPLICANT                 :   Ubiquiti Networks, Inc.
                EQUIPMENT                 :   airCube loco
                BRAND NAME                :   UBIQUITI
                MODEL NAME                :   ACB-LOCO
                FCC ID                    : SWX-ACBLOCO
                STANDARD                  : FCC 47 CFR FCC Part 15 Subpart B
                CLASSIFICATION            : Certification

     The product was received on Oct. 06, 2017 and testing was completed on Oct. 12, 2017. We,
     SPORTON INTERNATIONAL INC., would like to declare that the tested sample has been
     evaluated in accordance with the test procedures given in ANSI C63.4-2014 and has been in
     compliance with the applicable technical standards.
     The test results in this report apply exclusively to the tested model / sample. Without written
     approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except
     in full.




      Reviewed by: Louis Wu / Manager




      Approved by: Jones Tsai / Manager


                             SPORTON INTERNATIONAL INC.
No. 52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Tao Yuan City, Taiwan, R.O.C.
SPORTON INTERNATIONAL INC.                                              Page Number          : 1 of 18
TEL : 886-3-327-3456                                                    Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                    Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                 Report Template No.: BU5-FD15B Version 2.0


               FCC Test Report                                                                                              Report No. : FC741927-02




                                                    TABLE OF CONTENTS

REVISION HISTORY.......................................................................................................................................... 3

SUMMARY OF TEST RESULT ......................................................................................................................... 4

1. GENERAL DESCRIPTION .......................................................................................................................... 5
      1.1.     Applicant ............................................................................................................................................ 5
      1.2.     Manufacturer ..................................................................................................................................... 5
      1.3.     Product Feature of Equipment Under Test ....................................................................................... 5
      1.4.     Modification of EUT ........................................................................................................................... 5
      1.5.     Test Location ..................................................................................................................................... 5
      1.6.     Applicable Standards ........................................................................................................................ 6

2. TEST CONFIGURATION OF EQUIPMENT UNDER TEST ........................................................................ 7
      2.1.     Test Mode ......................................................................................................................................... 7
      2.2.     Connection Diagram of Test System ................................................................................................ 7
      2.3.     Support Unit used in test configuration and system .......................................................................... 8
      2.4.     EUT Operation Test Setup ................................................................................................................ 8

3. TEST RESULT ............................................................................................................................................. 9
      3.1.     Test of AC Conducted Emission Measurement ................................................................................ 9
      3.2.     Test of Radiated Emission Measurement ....................................................................................... 13

4. LIST OF MEASURING EQUIPMENT ........................................................................................................ 17

5. UNCERTAINTY OF EVALUATION ........................................................................................................... 18

APPENDIX A. SETUP PHOTOGRAPHS




SPORTON INTERNATIONAL INC.                                                                                      Page Number          : 2 of 18
TEL : 886-3-327-3456                                                                                            Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                                                            Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                                                         Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report                                                   Report No. : FC741927-02




                                 REVISION HISTORY

  REPORT NO.       VERSION                         DESCRIPTION                         ISSUED DATE

  FC741927-02       Rev. 01   Initial issue of report                                  Nov. 22, 2017




SPORTON INTERNATIONAL INC.                                          Page Number          : 3 of 18
TEL : 886-3-327-3456                                                Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                             Report Template No.: BU5-FD15B Version 2.0


           FCC Test Report                                                       Report No. : FC741927-02




                             SUMMARY OF TEST RESULT

  Report
             FCC Rule             Description            Limit          Result               Remark
 Section

                                                                                           Under limit
   3.1        15.107         AC Conducted Emission   < 15.107 limits     PASS
                                                                                      8.90 dB at 0.518 MHz

                                                                                           Under limit
   3.2        15.109           Radiated Emission     < 15.109 limits     PASS
                                                                                     7.21 dB at 30.000 MHz




SPORTON INTERNATIONAL INC.                                                Page Number          : 4 of 18
TEL : 886-3-327-3456                                                      Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                      Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                   Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report                                                         Report No. : FC741927-02



1. General Description

1.1. Applicant
     Ubiquiti Networks, Inc.
     685 Third Avenue, 27th Floor New York, New York 10017 USA


1.2. Manufacturer
     Ubiquiti Networks, Inc.
     685 Third Avenue, 27th Floor New York, New York 10017 USA


1.3. Product Feature of Equipment Under Test
     Wi-Fi 2.4GHz 802.11b/g/n
                               Product Specification subjective to this standard
      Antenna Type                         WLAN: Internal Antenna



1.4. Modification of EUT
     No modifications are made to the EUT during all test items.


1.5. Test Location
     Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code : 1190) and the
     FCC designation No. TW1093 under the FCC 2.948(e) by Mutual Recognition Agreement (MRA) in
     FCC Test.
      Test Site                  SPORTON INTERNATIONAL INC.
                                                  st
                                 No. 52, Hwa Ya 1 Rd., Hwa Ya Technology Park,
                                 Kwei-Shan District, Tao Yuan City, Taiwan, R.O.C.
      Test Site Location
                                 TEL: +886-3-327-3456
                                 FAX: +886-3-328-4978
                                                            Sporton Site No.
      Test Site No.
                                              CO05-HY                                03CH06-HY




SPORTON INTERNATIONAL INC.                                                Page Number          : 5 of 18
TEL : 886-3-327-3456                                                      Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                      Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                   Report Template No.: BU5-FD15B Version 2.0


          FCC Test Report                                                       Report No. : FC741927-02


1.6. Applicable Standards
     According to the specifications of the manufacturer, the EUT must comply with the requirements of the
     following standards:
          FCC 47 CFR FCC Part 15 Subpart B
          ANSI C63.4-2014


     Remark: All test items were verified and recorded according to the standards and without any deviation
              during the test.




SPORTON INTERNATIONAL INC.                                               Page Number          : 6 of 18
TEL : 886-3-327-3456                                                     Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                     Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                  Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report                                                                         Report No. : FC741927-02



2. Test Configuration of Equipment Under Test

2.1. Test Mode
     The EUT has been associated with peripherals pursuant to ANSI C63.4-2014 and configuration
     operated in a manner tended to maximize its emission characteristics in a typical application.
     Frequency range investigated: conduction emission (150 kHz to 30 MHz), radiation emission (30MHz
     to the 5th harmonic of the highest fundamental frequency or to 40 GHz, whichever is lower).


         Test Items                                                  Function Type

        AC Conducted
                           Mode 1 : WLAN Idle + WAN Link + LAN Link + Adapter
          Emission

          Radiated
                           Mode 1 : WLAN Idle + WAN Link + LAN Link + Adapter
          Emissions



2.2. Connection Diagram of Test System


              System                                                                                     BT
                                  AP router              Notebook            GPS Station
              Simulator                                                                               Earphone



               Power
                                                           EUT                                        Notebook
               Source




               Cradle              Earphone                iPod                WLAN AP                 Monitor




                              This example is connection diagram of EUT test configurations.

               . For detail, please refer to test mode configuration and setup photographs for each test item.




SPORTON INTERNATIONAL INC.                                                              Page Number          : 7 of 18
TEL : 886-3-327-3456                                                                    Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                                    Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                                 Report Template No.: BU5-FD15B Version 2.0


            FCC Test Report                                                  Report No. : FC741927-02


2.3. Support Unit used in test configuration and system
Item Equipment     Trade Name Model Name        FCC ID          Data Cable        Power Cord
1.   LCD MONITOR Dell          P2715Qt          FCC DoC          Shielded, 1.6m Unshielded, 1.8 m
2.   iPod          Apple       A1285            FCC DoC         Shielded, 1.0 m N/A
                                                                                  AC I/P:
                                                FCC DoC/
                                                                                  Unshielded, 1.2 m
3.   Notebook      DELL        Latitude E6320   Contains FCC ID: N/A
                                                                                  DC O/P:
                                                QDS-BRCM1054
                                                                                  Shielded, 1.8 m
                                                                                  AC I/P:
                                                FCC DoC/
                                                                                  Unshielded, 1.2 m
4.   Notebook      DELL        Latitude E3340   Contains FCC ID: N/A
                                                                                  DC O/P:
                                                PD97260NGU
                                                                                  Shielded, 1.8 m
5.   Adapter       HUAWEI      HW-059200UHQ     N/A                    N/A               N/A
6.   HUB           D-Link      DES-1005A        FCC DoC         N/A               Unshielded, 1.4m
7.   WLAN AP       ASUS        RT-AC66U         MSQ-RTAC66U     N/A               Unshielded,1.8m
8.   Smart phone   Apple       A1529            BCG-E2694A      N/A               N/A




2.4. EUT Operation Test Setup
     At the same time, the EUT was attached to the Smart phone or WLAN AP, and EUT links with Notebook
     and execute ping via RJ-45.




SPORTON INTERNATIONAL INC.                                            Page Number          : 8 of 18
TEL : 886-3-327-3456                                                  Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                  Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                               Report Template No.: BU5-FD15B Version 2.0


            FCC Test Report                                                        Report No. : FC741927-02



3. Test Result

3.1. Test of AC Conducted Emission Measurement
3.1.1 Limits of AC Conducted Emission
       For equipment that is designed to be connected to the public utility (AC) power line, the radio
       frequency voltage that is conducted back onto the AC power line on any frequency or frequencies
       within the band 150 kHz to 30 MHz shall not exceed the limits in the following table.

         Frequency of emission                                Conducted limit (dBuV)
                  (MHz)                         Quasi-peak                              Average

                 0.15-0.5                         66 to 56*                             56 to 46*

                   0.5-5                             56                                     46
                   5-30                              60                                     50


       *Decreases with the logarithm of the frequency.



3.1.2 Measuring Instruments
       The measuring equipment is listed in the section 4 of this test report.



3.1.3 Test Procedure
       1.     The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept at least
              80 centimeters from any other grounded conducting surface.
       2.     Connect EUT to the power mains through a line impedance stabilization network (LISN).
       3.     All the support units are connecting to the other LISN.
       4.     The LISN provides 50 ohm coupling impedance for the measuring instrument.
       5.     The FCC states that a 50 ohm, 50 microhenry LISN should be used.
       6.     Both sides of AC line were checked for maximum conducted interference.
       7.     The frequency range from 150 kHz to 30 MHz was searched.
       8.     Set the test-receiver system to Peak Detect Function and specified bandwidth (IF Bandwidth =
              9kHz) with Maximum Hold Mode. Then measurement is also conducted by Average Detector
              and Quasi-Peak Detector Function respectively.




SPORTON INTERNATIONAL INC.                                                  Page Number          : 9 of 18
TEL : 886-3-327-3456                                                        Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                        Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                     Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report               Report No. : FC741927-02


3.1.4 Test Setup




SPORTON INTERNATIONAL INC.      Page Number          : 10 of 18
TEL : 886-3-327-3456            Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978            Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO         Report Template No.: BU5-FD15B Version 2.0


 seosrovcas. FCC TeSt Report                                                                                           Report No. : FC741927—02


3.1.5 Test Result of AC Conducted Emission
                                                                                                    Temperature :                      26~27°C
         Test Engineer :           |Blue Lan                                                             —       —~
                                                                                                    Relative Humidity :                |46~47%
         Test Voltage :            |120Vac / 60Hz                                                    Phase :                           Line

                                      w00


                                      so


                                      EJ


                                      To

                                      ao                                                           CISPR22—GP Limit at Main Ports

                                  3 }
                                  1 m                Aw.
                                                                                                           ;
                                                                                                          $22—Ave Limit atMain Ports

                                  4 afh
                                  %




                                      20


                                       10




                                       150%           300 400 500      #00 1M       2M    3M   4M 8M 6         8 10M     20M   30M

                                                                                Frequency in Hz


                 Final Result : Quasi—Peak
                       Frequency        Quasi—Peak            Filter     Line    Corr.    Margin         Limit
                         (MHz)              (dBuV)                                (dB)      (dB)     (dBpV)
                       0.150000               43.9             Off        L1      19.6      22.1         66.0
                       0.470000               46.9             Off        L1      19.6       9.6         56.5
                       0.510000               45.8             Off        L1      19.6      10.2         56.0
                       0.622000               40.0             Off        L1      19.6      16.0         56.0
                       0.734000               36.7             Off        L1      19.6      19.3         56.0
                       0.982000               41.3             Off        L1      19.6      14.7         56.0
                       1.374000               35.4             Off        L1      19.6      20.6         56.0
                       1.606000               31.1             Off        L1      19.6      24.9         56.0


                 Final Result : Average
                       Frequency            Average           Filter     Line    Cort.    Margin         Limit
                         (MHz)              (dBuV)                                (dB)      (dB)     (dBpV)
                       0.150000               30.6             Off        L1      19.6      25.4         56.0
                       0.470000               38.4             Off        L1      19.6      13.1         46.5
                       0.510000               35.1             Off        L1      19.6      10.9         46.0
                       0.622000               290.2            Off        L1      19.6      16.8         46.0
                       0.734000               27.0             Off        L1      19.6      19.0         46.0
                       0.982000               34.2             Off        L1      19.6      11.8         46.0
                       1.374000               26.1             Off        L1      19.6      19.9         46.0
                       1.606000               22.6             Off        L1      19.6      23.4         46.0




SPORTON INTERNATIONAL INC.                                                                                      Page Number            : 11 of 18
TEL : 886—3—327—3456                                                                                            Report Issued Date : Nov. 22, 2017
FAX : 886—3—328—4978                                                                                         Report Version      : Rev. 01
FCC ID : SWX—ACBLOCO                                                                                     Report Template No.: BUS—FD15B Version 2.0


 seosrovcas. FCC TeSt Report                                                                                           Report No. : FC741927—02



                                                                                                    Temperature :                    26~27°C
         Test Engineer :           |Blue Lan
                                                                                                    Relative Humidity :              (46~47%
         Test Voltage :            |120Vac / 60Hz                                                   Phase :                          Neutral

                                    100


                                    90


                                    B0


                                    To


                                  L DWM
                                  $ o          *                                                  (°
                                  bal          0
                                    sp
                                               *
                                    2


                                     10




                                     150k          500 400 500      800 th       2M    ho      4M 5M 6     8     10M     20M   30M

                                                                             Frequency in Hz


                 Final Result : Quasi—Peak
                       Frequency      Quasi—Peak             .         .      Cort.    Margin          Limit
                                                           Filter     Line
                         (MHz)            (dBuV)                               (dB)      (dB)       (dBuV)
                       0.150000             48.0            Off         N      19.5      18.0            66.0
                       0.270000             38.3            Off         N      19.5      22.8            61.1
                       0.470000             41.5            Off         N      19.5      15.0            56.5
                       0.518000             44.1            Off         N      19.5      11.9            56.0
                       0.622000             36.6            Off         N      19.5      19.4            56.0
                       0.982000             35.8            Off         N      19.6      20.2            56.0
                       1.462000             30.2            Off         N      19.6      25.8            56.0
                       1.702000             30.4            Off         N      19.6      25.6            56.0


                 Final Result : Average
                       Frequency          Average          Filter     Line    Cort.    Margin          Limit
                         (MHz)            (dBuV)                              (dB)       (dB)       (dBuV)
                       0.150000             30.0            Off         N      19.5      26.0            56.0
                       0.270000             24.7            Off         N      19.5      26.4            51.1
                       0.470000             27.7            Off         N      19.5      18.8            46.5
                       0.518000             37.1            Off         N      19.5       8.9            46.0
                       0.622000             25.3            Off         N      19.5      20.7            46.0
                       0.982000             25.9            Off         N      19.6      20.1            46.0
                       1.462000             22.3            Off         N      19.6      23.7            46.0
                       1.702000             22.3            Off         N      19.6      23.7            46.0




SPORTON INTERNATIONAL INC.                                                                                      Page Number          : 12 of 18
TEL : 886—3—327—3456                                                                                            Report Issued Date : Nov. 22, 2017
FAX : 886—3—328—4978                                                                                       Report Version      : Rev. 01
FCC ID : SWX—ACBLOCO                                                                                   Report Template No.: BUS—FD15B Version 2.0


            FCC Test Report                                                        Report No. : FC741927-02


3.2. Test of Radiated Emission Measurement
3.2.1. Limit of Radiated Emission
       The emissions from an unintentional radiator shall not exceed the field strength levels specified in the
       following table:
                   Frequency                          Field Strength             Measurement Distance
                     (MHz)                        (microvolts/meter)                      (meters)
                     30 – 88                               100                                3

                    88 – 216                               150                                3

                    216 - 960                              200                                3

                   Above 960                               500                                3



3.2.2. Measuring Instruments
       The measuring equipment is listed in the section 4 of this test report.

3.2.3. Test Procedures
       1.     The EUT was placed on a turntable with 0.8 meter above ground.
       2.     The EUT was set 3 meters from the interference receiving antenna, which was mounted on the
              top of a variable height antenna tower.
       3.     The table was rotated 360 degrees to determine the position of the highest radiation.
       4.     The antenna is a Bi-Log antenna and its height is adjusted between one to four meters above
              ground to find the maximum value of the field strength for both horizontal polarization and
              vertical polarization of the antenna.
       5.     For each suspected emission, the EUT was arranged to its worst case and then tune the
              antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the
              maximum reading.
       6.     Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum
              Hold Mode (RBW=120kHz/VBW=300kHz for frequency below 1GHz; RBW=1MHz VBW=3MHz
              (Peak), RBW=1MHz/VBW=10Hz (Average) for frequency above 1GHz).
       7.     If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, peak
              values of EUT will be reported. Otherwise, the emission will be repeated by using the
              quasi-peak method and reported.
       8.     Emission level (dBµV/m) = 20 log Emission level (µV/m)
       9.     Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level




SPORTON INTERNATIONAL INC.                                                  Page Number          : 13 of 18
TEL : 886-3-327-3456                                                        Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                                        Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                                     Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report                                     Report No. : FC741927-02


3.2.4. Test Setup of Radiated Emission
       For radiated emissions from 30MHz to 1GHz




       For radiated emissions above 1GHz




SPORTON INTERNATIONAL INC.                            Page Number          : 14 of 18
TEL : 886-3-327-3456                                  Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                  Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                               Report Template No.: BU5-FD15B Version 2.0


 seosrovcas. FCC TeSt Report                                                                                                    Report No. : FC741927—02


3.2.5. Test Result of Radiated Emission

                       .                                                            Temperature :                         23~250
         Test Engineer :                |Donny Tang
                                                                                    Relative Humidity :                   |50~52%
         Test Distance :                |3m                                         Polarization :                        Horizontal

                             g7L|!‘ve| (dBuVim)                                                                                           Date: 2017—10—12



                            84.9

                                                                                                                                            FCC class.8
                            724
                                                                                                                                                    —6dB

                            60.6
                                                                                                                                     FCC CLAKSB (AVG)
                                                                                                                                      1h2        :608
                            a8.5                                                               3                      o
                                                               4           8
                            36.4;‘ 33


                            24.3


                            121



                                   30                   2624.                  5218.                     7812.                   10406.              13000
                                                                                       Frequency (MHz)
                           Site                      : 03CHO6—HY
                           Condition                 : FCC CLASS—B 3m.91200_1156_170915 HORIZONTAL
                           Project                   :741927—02
                           Power                     : 120Vac/60Hz
                           Memo                      : Mode 1
                                                                    Over   Limit     ReadAntenna          Cable Preamp           A/Pos     T/Pos
                                              Freq    Level        Limit     Line   Level Factor           Loss Factor                              Remark

                                              MHz dBuV/m             dB dBuV/m         dBuV     dB/m             dB        dB        cm       deg

                             1            30.00       21.84     —18.16     40.00    27.48     24.30         1.99      31.84        ———        ———   Peak
                             2           105.60       29.54     —13.96     43.50    42.72     16.61         2.02      31.81        ———        ———   Peak
                             3           246.00       31.30     —14.70     46.00    42.76     18.11         2.19      31.76        ———        ———   Peak
                             4           564.60       31.87     —14.13     46.00    34.61     26.10         3.16      32.00        ———        ———   Peak
                             5           742.40       34.41     —11.59     46.00    34.80     28.26          3.41     32.06        100        159   Peak
                             6           874.70        34.36    —11.64     46.00    33.42     29.25          3.35     31.66        ———        ———   Peak
                             7          2992.00       36.64     —37.36     74.00    61.33     28.69         7.91      61.29        ———        ———   Peak
                             8          4440.00       39.36     —34.64     74.00    59.66     30.43         9.79      60.52        ———        ———   Peak
                             9          6782.00       43.25     —30.75     74.00    55.12     34.91        12.51      59.29        ———        ———   Peak
                            10          8968.00       44.30     —29.70     74.00    59.97     36.91        14.79      58.37        ———        ———   Peak
                            11          10918.00      48.50     —25.50     74.00    49.50     40.02        16.19      57.21        100        150   Peak
                            12          11154.00      47.78     —26.22     74.00    48.33     39.89        16.41      56.85        ———        ———   Peak




SPORTON INTERNATIONAL INC.                                                                                            Page Number               : 15 of 18
TEL : 886—3—327—3456                                                                                                  Report Issued Date : Nov. 22, 2017
FAX : 886—3—328—4978                                                                                                 Report Version      : Rev. 01
FCC ID : SWX—ACBLOCO                                                                                             Report Template No.: BUS—FD15B Version 2.0


 seosrovcas. FCC TeSt Report                                                                                                      Report No. : FC741927—02



                       .                                                             Temperature :                          23~250
         Test Engineer :                |Donny Tang                                       —       —
                                                                                     Relative Humidity :                    |50~52%
         Test Distance :                |3m                                          Polarization :                         Vertical

                             u7 Level (dBuVim)                                                                                               Date: 2017—10—12


                            s4.9
                                                                                                                                               rct class.8
                            724
                                                                                                                                                       —6d8

                            60.6
                                                                                                                                        FCC CLAKSB (AVG)
                                                                                                                                            1142          :608
                            48.5                                7                                 3                    10
                                                                            8
                            mg          15¢


                            24.3


                            121


                                   30                   2624.                   5218.                     7812.                    10406.                 13000
                                                                                        Frequency (MHz)
                           Site                      : 03CHO6—HY
                           Condition                 : FCC CLASS—B 3m 91200_1156_170915 VERTICAL
                           Project                   :741927—02
                           Power                     : 120Vac/60Hz
                           Memo                      : Mode 1
                                                                     Over   Limit     ReadAntenna          Cable Preamp            A/Pos      T/Pos
                                              Freq     Level        Limit     Line   Level Factor           Loss Factor                                  Remark

                                              MHz dBuV/m              dB dBuV/m         dBuV     dB/m             dB         dB         cm         deg

                             1            30.00       32.79      —7.21      40.00    38.43     24.30         1.99       31.84          100         121   Peak
                             2            35.40       30.39      —9.61      40.00    39.16     21.15         1.92       31.84          ———         ———   Peak
                             3           157.71       32.22     —11.28      43.50    45.48     16.49         2.13       31.79          ———         ———   Peak
                             4           620.60       35.02     —10.98      46.00    37.46     26.44          3.18      32.06          ———         ———   Peak
                             5           742.40       34.34     —11.66      46.00    34.73     28.26          3.41      32.06          ———         ———   Peak
                             6           931.40       33.31     —12.69      46.00    30.90     30.51         3.18       31.28          ———         ———   Peak
                             7          3000.00       43.50     —30.50      74.00    68.15     28.74         7.91       61.30          ———         ———   Peak
                             8          4386.00       39.21     —34.79      74.00    59.74     30.38         9.73       60.64          ———         ———   Peak
                             9          6980.00       43.55     —30.45      74.00    54.58     35.45        12.73       59.21          ———         ———   Peak
                            10          8770.00       44.66     —29.34      74.00    S1.18     36.78        14.83       58.13          ———         ———   Peak
                            11          10956.00      48.49     —25.51      74.00    49.29     40.09        16.21       57.10          100         151   Peak
                            12          11276.00      47.44     —26.56      74.00    47.93     39.70        16.53       56.72          ———         ———   Peak




SPORTON INTERNATIONAL INC.                                                                                              Page Number                 : 16 of 18
TEL : 886—3—327—3456                                                                                                    Report Issued Date : Nov. 22, 2017
FAX : 886—3—328—4978                                                                                                  Report Version      : Rev. 01
FCC ID : SWX—ACBLOCO                                                                                              Report Template No.: BUS—FD15B Version 2.0


                FCC Test Report                                                                       Report No. : FC741927-02



   4. List of Measuring Equipment
                                                                              Calibration
 Instrument     Manufacturer    Model No.     Serial No.   Characteristics                      Test Date       Due Date         Remark
                                                                                 Date
 AC Power                                                                                                                      Conduction
                  ChainTek     APC-1000W         N/A            N/A              N/A           Oct. 12, 2017       N/A
  Source                                                                                                                       (CO05-HY)
  EMI Test        Rohde &                                                                                                      Conduction
                                 ESCI 7        100724       9kHz~7GHz        Sep. 20, 2017     Oct. 12, 2017   Sep. 19, 2018
  Receiver        Schwarz                                                                                                      (CO05-HY)
                  Rohde &                                                                                                      Conduction
    LISN                         ENV216        100080       9kHz~30MHz       Nov. 29, 2016     Oct. 12, 2017   Nov. 28, 2017
                  Schwarz                                                                                                      (CO05-HY)
                  Rohde &                                                                                                      Conduction
    LISN                         ENV216        100081       9kHz~30MHz       Dec. 06, 2016     Oct. 12, 2017   Dec. 05, 2017
                  Schwarz                                                                                                      (CO05-HY)
                               CBL6111C&N- 2725&AT-N06                                                                           Radiation
Bilog Antenna    Schaffner                             30MHz~1GHz            Oct. 15, 2016     Oct. 12, 2017   Oct. 14, 2017
                                   6-06        01                                                                              (03CH06-HY)
  EMI Test        Rohde &                                                                                                        Radiation
                                 ESU26         100472      20Hz~26.5GHz Dec. 29, 2016          Oct. 12, 2017   Dec. 28, 2017
  Receiver        Schwarz                                                                                                      (03CH06-HY)
                SCHWARZBE                                                                                                        Radiation
Horn Antenna              BBHA 9120 D        9120D-1156    1GHz~18GHz        Aug. 08, 2017     Oct. 12, 2017   Aug. 07, 2018
                   CK                                                                                                          (03CH06-HY)
                                                                                                                                 Radiation
Preamplifier     SONOMA           310N         186713       9kHz~1GHz        Apr. 25, 2017     Oct. 12, 2017   Apr. 24, 2018
                                                                                                                               (03CH06-HY)
                               AMF-7D-0010                                                                                       Radiation
Preamplifier      MITEQ                       1850117      1GHz ~ 18GHz May 22, 2017           Oct. 12, 2017   May. 21, 2018
                               1800-30-10P                                                                                     (03CH06-HY)
                                             MF78020821                                                                          Radiation
Antenna Mast        MF           MF-7802                       1m~4m             N/A           Oct. 12, 2017       N/A
                                                 2                                                                             (03CH06-HY)
                                                                                                                                 Radiation
 Turn Table       INN-CO         DS2000      420/650/00     0-360 degree         N/A           Oct. 12, 2017       N/A
                                                                                                                               (03CH06-HY)




   SPORTON INTERNATIONAL INC.                                                                  Page Number          : 17 of 18
   TEL : 886-3-327-3456                                                                        Report Issued Date : Nov. 22, 2017
   FAX : 886-3-328-4978                                                                        Report Version       : Rev. 01
   FCC ID : SWX-ACBLOCO                                                                     Report Template No.: BU5-FD15B Version 2.0


         FCC Test Report                                                Report No. : FC741927-02



5. Uncertainty of Evaluation
     Uncertainty of Conducted Emission Measurement (150 kHz ~ 30 MHz)
       Measuring Uncertainty for a Level of Confidence
                                                                         2.7
                    of 95% (U = 2Uc(y))


     Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)
       Measuring Uncertainty for a Level of Confidence
                                                                         3.9
                    of 95% (U = 2Uc(y))


     Uncertainty of Radiated Emission Measurement (1000 MHz ~ 18000 MHz)
       Measuring Uncertainty for a Level of Confidence
                                                                         4.7
                    of 95% (U = 2Uc(y))




SPORTON INTERNATIONAL INC.                                      Page Number          : 18 of 18
TEL : 886-3-327-3456                                            Report Issued Date : Nov. 22, 2017
FAX : 886-3-328-4978                                            Report Version       : Rev. 01
FCC ID : SWX-ACBLOCO                                         Report Template No.: BU5-FD15B Version 2.0



Document Created: 2017-11-24 13:53:57
Document Modified: 2017-11-24 13:53:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC