                           EMC TEST REPORT


                           Applicant            RAE Systems, Inc

                           FCC ID               SU3RMBLED

                           Product              RMBLED

                           Brand                Honeywell

                           Model                RMBLED

                           Report No.           R1908A0477-E1

                           Issue Date           September 9, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
Code CFR47 Part15B (2018)/ ANSI C63.4 (2014). The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.




              Performed by: Wei Liu/ Manager           Approved by: Guangchang Fan/ Director




               TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


               EMC Test Report                                                                           Report No.: R1908A0477-E1



                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 4
 1.1    Notes of the Test Report ......................................................................................................... 4
 1.2    Test facility .............................................................................................................................. 4
 1.3    Testing Location ...................................................................................................................... 5
2 General Description of Equipment under Test ................................................................................ 6
 2.1    Client Information .................................................................................................................... 6
 2.2    General information ................................................................................................................. 6
 2.3    Applied Standards ................................................................................................................... 7
 2.4    Test Mode................................................................................................................................ 8
3 Test Case Results .......................................................................................................................... 9
 3.1    Radiated Emission .................................................................................................................. 9
 3.2    Conducted Emission ............................................................................................................. 14
4 Main Test Instrument .................................................................................................................... 18




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 2 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              EMC Test Report                                                            Report No.: R1908A0477-E1




                                  Summary of measurement results
   Number              Test Case                        Clause in FCC Rules                              Conclusion
          1            Radiated Emission                FCC Part15.109, ANSI C63.4-2014                       PASS
          2            Conducted Emission               FCC Part15.107, ANSI C63.4-2014                       PASS
                                  Test Date: August 27,2019 ~ August 30,2019




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 3 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above.


1.2 Test facility

FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 4 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 5 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1




2 General Description of Equipment under Test

2.1 Client Information

   Applicant                             RAE Systems, Inc
   Applicant address                     1349 Moffett Park Drive, Sunnyvale, CA94089, USA Sunnyvale
   Manufacturer                          RAE Systems, Inc
   Manufacturer address                  1349 Moffett Park Drive, Sunnyvale, CA94089, USA Sunnyvale



2.2 General information

                                                    EUT Description
Device Type:                  Module
Model:                        RMBLED
IMEI:                         /
HW Version:                   Rev A
SW Version:                       V2.0
Antenna Type:                 Internal Antenna
                                         Band                        Tx (MHz)                          Rx (MHz)
Frequency:
                              Bluetooth:                           2402 ~ 2480                       2402 ~ 2480
Modulation:                   Bluetooth v5.0 LE: GFSK
                                                Auxiliary test equipment
                              PC Manufacturer: Dell
PC
                              Model: E5430 (SN : R98M9 A02)
Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 6 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1


2.3 Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:

Test standards
FCC Code CFR47 Part15B (2018)
ANSI C63.4 (2014)




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 7 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1


2.4 Test Mode

     Test Mode
     Mode 1                      EUT with PC power supply + EUT +Idle




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 8 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1




3 Test Case Results

3.1 Radiated Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C~26°C                     45%~50%                               102.5kPa



Methods of Measurement

The EUT is placed on a non-metallic table 0.8m above the horizontal metal reference ground plane.
The distance between EUT and receive antenna should be 3 meters. During the test, the EUT was
operating in its typical mode. The test method is according to ANSI C63.4-2014. Sweep the whole
frequency band through the range from 30MHz to the 5th harmonic of the carrier. During the test, the
height of receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed
under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated signal level.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing. During the test, the EUT is worked at maximum output power.
Set the spectrum analyzer in the following:
Below 1GHz:
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz:
(a) PEAK: RBW=1MHz / VBW=3MHz/ Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=3MHz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the
worst case was recorded.

During the test, EUT is connected to a laptop via a USB cable in the case of Transfer Data mode. The
EUT is used as the peripheral equipment of the PC. The data is transferred from EUT to PC.

During the test, EUT is connected to a laptop via a USB cable in the case of power supply.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 9 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1

Test Setup



Below 1GHz




     Above 1GHz




Note: Area side:2.4mX3.6m

Antenna Tower meets ANSI C63.4 requirements for measurements above 1 GHz by keeping the
antenna aimed at the EUT during the antenna’s ascent/ descent along the antenna mast.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 10 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1
Limits

                  Frequency                               Field Strength
                                                                                                   Detector
                    (MHz)                                   (dBμV/m)
                     30 -88                                     40.0                              Quasi-peak
                    88-216                                      43.5                              Quasi-peak
                   216 – 960                                    46.0                              Quasi-peak
                   960-1000                                     54.0                              Quasi-peak
     1000-5th harmonic of the highest                             54                                Average
   frequency or 40GHz,which is lower                              74                                  Peak



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.


                              Frequency                                           Uncertainty
                         30MHz~200MHz                                               4.02 dB
                        200MHz~1000MHz                                              3.28 dB
                           1GHz~18GHz                                               3.70 dB
                         18GHz~26.5GHz                                              5.78 dB
                         26.5GHz~40GHz                                              5.82 dB




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 11 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                          EMC Test Report                                                             Report No.: R1908A0477-E1
Test Results

Sweep the whole frequency band through the range from 30MHz to the 5th harmonic of the carrier,
the Emissions in the frequency band 18GHz- 26.5GHz is more than 20dB below the limit are not
reported.

The following graphs display the maximum values of horizontal and vertical by software.
For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.

                          100

                          90

                          80

                          70

                          60
                                                                                                               FCC RE QP
         Level in dBμV/




                          50

                          40

                          30

                          20

                           10

                           0
                           30M            50   60      80   100M            200         300     400   500        800   1G

                                                                   Frequency in Hz


                                                    Radiated Emission from 30MHz to 1GHz
Frequency                       Quasi-Peak Height              Azimuth                         Correct        Margin   Limit
                                                  Polarization
  (MHz)                          (dBuV/m)   (cm)                (deg)                         Factor (dB)      (dB)  (dBuV/m)
41.816847                          21.3             100.0          V          138.0              -4.4           18.7        40.0
47.583244                          21.0             100.0          V          334.0              -4.7           19.0        40.0
53.105853                          18.1             100.0          V              0.0            -6.6           21.9        40.0
100.193240                         21.4             125.0          V          283.0              -10.2          22.1        43.5
184.249425                         25.4             100.0          V          327.0              -13.0          18.1        43.5
379.984250                         18.8             125.0          V          282.0              -5.6           27.2        46.0
Remark: 1. Correction Factor = Antenna factor+ Insertion loss(cable loss+amplifier gain)
        2. Margin = Limit – Quasi-Peak




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 12 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                                 Report No.: R1908A0477-E1




                              120

                              110

                              100

                              90

                              80
                                                                                                   FCC RE PK(Class B)
             Level in dBμV/




                              70

                              60
                                                                                                   FCC RE AV(Class B)
                              50

                              40

                              30

                              20

                               10
                                1G              2G       3G           4G    5G      6    8       10G                18G
                                                                  Frequency in Hz


                                              Radiated Emission from 1GHz to 18GHz
                                                                                        Correct
                                       Peak   Height              Azimuth                              Margin   Limit
    Frequency                                        Polarization                       Factor
                                     (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
      (MHz)                                                                              (dB)
   1535.500000                         33.5    100.0          V             106.0        -15.8          40.5            74.0
   2398.250000                         36.7    100.0          V             358.0        -11.6          37.3            74.0
   4098.250000                         40.0    200.0          V             203.0        -5.4           34.0            74.0
   6042.625000                         42.4    100.0          H             133.0        -1.8           31.6            74.0
   8896.500000                         44.2    200.0          H              68.0         1.3           29.8            74.0
  11055.500000                         45.5    200.0          V             113.0         3.4           28.5            74.0


                                                                                        Correct
    Frequency                         Average Height              Azimuth                              Margin   Limit
                                                     Polarization                       Factor
      (MHz)                          (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
                                                                                         (dB)
   1599.250000                         23.1    100.0          V             241.0        -15.4          30.9            54.0
   2547.000000                         26.1    200.0          H             339.0        -11.1          27.9            54.0
   4125.875000                         30.0    100.0          H             239.0        -5.3           24.0            54.0
   6848.000000                         32.2    200.0          V               1.0        -1.0           21.8            54.0
   8541.625000                         33.7    200.0          V              75.0         1.0           20.3            54.0
  11049.125000                         34.5    200.0          H             173.0         3.3           19.5            54.0




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 13 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              EMC Test Report                                                            Report No.: R1908A0477-E1




3.2 Conducted Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C ~26°C                    50%~55%                               102.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.4-2014. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz. The
measurement result should include both L line and N line.

During the test, EUT is connected to a laptop via a USB cable in the case of Transfer Data mode. The
EUT is used as the peripheral equipment of the PC. The data is transferred from EUT to PC.

During the test, EUT is connected to a laptop via a USB cable in the case of power supply.


Test Setup




Note: Power Supply is AC Power source and it is used to change the voltage 120V/60Hz.

Limits

           Frequency                                            Conducted Limits(dBμV)
             (MHz)                              Quasi-peak                                      Average
                                                            *                                            *
            0.15 - 0.5                           66 to 56                                      56 to 46
              0.5 - 5                                56                                            46
              5 - 30                                 60                                            50
   *:
        Decreases with the logarithm of the frequency.

TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 14 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1
Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96. U= 2.57 dB.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 15 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1
Test Results

Following plots, Blue trace uses the peak detection; Green trace uses the average detection.




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.15            54.89              ---        66.00       11.11      1000.0          9.000          L1      ON       19.06
    0.15               ---           33.94        55.88       21.94      1000.0          9.000          L1      ON       19.05
    0.62               ---           25.33        46.00       20.67      1000.0          9.000          L1      ON       19.27
    0.62            29.32              ---        56.00       26.68      1000.0          9.000          L1      ON       19.27
    0.89               ---           20.16        46.00       25.84      1000.0          9.000          L1      ON       19.24
    1.20            24.82              ---        56.00       31.18      1000.0          9.000          L1      ON       19.23
    2.99            35.83              ---        56.00       20.17      1000.0          9.000          L1      ON       19.11
    2.99               ---           24.13        46.00       21.87      1000.0          9.000          L1      ON       19.11
    5.39            27.93              ---        60.00       32.08      1000.0          9.000          L1      ON       19.10
    5.87               ---           20.92        50.00       29.08      1000.0          9.000          L1      ON       19.10
   12.45            26.28              ---        60.00       33.72      1000.0          9.000          L1      ON       19.44
   12.74               ---           20.50        50.00       29.50      1000.0          9.000          L1      ON       19.48
Remark: Correct factor=cable loss + LISN factor
                                           L line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 16 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.15            53.76              ---        66.00       12.24      1000.0          9.000          N       ON       19.08
    0.17               ---           33.01        54.84       21.83      1000.0          9.000          N       ON       19.16
    0.62               ---           24.58        46.00       21.42      1000.0          9.000          N       ON       19.27
    0.63            28.34              ---        56.00       27.66      1000.0          9.000          N       ON       19.27
    0.95               ---           19.13        46.00       26.87      1000.0          9.000          N       ON       19.24
    1.20            24.34              ---        56.00       31.66      1000.0          9.000          N       ON       19.23
    2.99               ---           23.90        46.00       22.10      1000.0          9.000          N       ON       19.11
    2.99            35.84              ---        56.00       20.16      1000.0          9.000          N       ON       19.11
    5.87               ---           19.55        50.00       30.45      1000.0          9.000          N       ON       19.10
   12.13            25.32              ---        60.00       34.68      1000.0          9.000          N       ON       19.39
   13.01               ---           20.20        50.00       29.80      1000.0          9.000          N       ON       19.48
   13.14            26.26              ---        60.00       33.74      1000.0          9.000          N       ON       19.47
Remark: Correct factor=cable loss + LISN factor
                                           N line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 17 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                             Report No.: R1908A0477-E1




4 Main Test Instrument

                                                                            Serial        Calibration        Expiration
         Name                  Manufacturer                Type
                                                                           Number            Date              Time
       Spectrum                                                           15195-01-
                                    R&S                   FSV40                            2019-05-19        2020-05-18
       Analyzer                                                              00
       EMI Test
                                    R&S                    ESCI             100948        2019-05-19        2020-05-18
       Receiver
    Trilog Antenna          SCHWARZBECK                VULB 9163          9163-201         2017-11-18        2019-11-17
    Horn Antenna                    R&S                   HF907             100126        2018-07-07         2020-07-06
    Standard Gain
                               ETS-Lindgren              3160-09          00102643         2018-06-20        2020-06-19
        Horn
       EMI Test
                                    R&S                    ESR              101667        2019-05-19         2020-05-18
       Receiver
          LISN                      R&S                  ENV216             101171        2016-12-16        2019-12-15
     Bore Sight
                                    ETS                   2171B           00058752               /                 /
    Antenna mast
    Test software                 EMC32                    R&S               9.26.0              /                 /




                                             *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 18 of 18
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-09-24 23:20:17
Document Modified: 2019-09-24 23:20:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC