                                                                  Low Frequency Monitor ITK-340
                                                                 •        900 MHz and Wi-Fi enabled
                                                                 •        Quick installation with convenient wall mounting bracket
                                                                 •        Can be configured and monitored by central server for
                                                                          superior control
                                                                 •        Battery-operated for plug-an-play installation – no wiring
                                                                          necessary
                                                                 •        2+ years battery life in egress detection mode (less than 1
                                                                          second update speed)
                                                                 •        10+ years battery life in location presence mode (1 minute
                                                                          updates)


                                                                  The Low Frequency (LF) Monitor is a signaling unit used with LF-
         ITK-340 Low Frequency Monitor
                                                                  enabled tags to segment zones or designate egress points. The LF
                                                                  Monitors create a detection “sphere”. When a tag enters the LF
                                                                  Monitor sphere, the tag’s LF sensor is triggered and the tag
                                                                  immediately reports this event to the CenTrak Location Engine.

                                                                  The LF Monitors are typically used to segment zones/areas and for
                                                                  egress detection. The LF Monitors may be strategically placed on the
                                                                  floor to define zonal areas. When a tag passes the LF Monitor, the
                                                                  system knows it passed from one zone to another zone. In the same
                                                                  manner, the LF Monitors may be placed in elevator banks and
                                                                  stairwells to determine if a tag passed from one floor to another. An
                                                                  additional use for the LF Monitors involves attaching the devices
                                                                  under beds and/or chairs to enable bed-/chair-level location accuracy.

                                                                  The battery operation and the extremely simple mounting mechanism,
                                                                  allow for the quick and low cost installation.
           ITA-790 Low Frequency
           Monitor Mounting Bracket




       CenTrak, Inc.
       5 Caufield Place, Suite 102
       Newtown, PA 18940
       t: 215-860-2928
       e: sales@centrak.com
       www.centrak.com



© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 7/12


                                                               Low Frequency Monitor ITK-340
                                                               Technical Specifications
                                                               Operation
                                                               FCC Operating Frequency Range                                           2.4 - 2.5 GHz
                                                                                                                                       902-928 MHz
                                                                                                                                       125 KHz

                                                               Reach
                                                               Low range                                                               Up to 4 ft. (battery operated)

                                                               Medium range                                                            Up to 8 ft. (battery operated)

                                                               Long range                                                              Up to 15 ft. (power adapter)


                                                               Enclosure
                                                               Length                                                                  7.38 in (186 mm)
         ITK-340 Low Frequency Monitor                         Width                                                                   4.75 in (120 mm)

                                                               Height                                                                  1.9 in (49 mm)

                                                               Weight                                                                  11.87 oz (.34 kg) without batteries

                                                               Mounting                                                                Wall mounting bracket

                                                               Monitor Mounting Plate                                                  ITA-790

                                                               Environmental
                                                               Operating Temperature                                                   0 C to +50 C

                                                               Storage temperature                                                     -20 C to +70 C

                                                               Operating Humidity                                                      10-90%, non-condensing


                                                               Power
           ITA-790 Low Frequency
           Monitor Mounting Bracket                            Battery type                                                            Pre-installed Lithium D Cell (4)




       CenTrak, Inc.
       5 Caufield Place, Suite 102
       Newtown, PA 18940
       t: 215-860-2928
       e: sales@centrak.com                                    This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful
       www.centrak.com                                         interference, and 2) this device must accept any interference received, including interference that may cases undesired operation. Modifying or
                                                               tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to
                                                               use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532

                                                               L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif
                                                               doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.




© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 7/12



Document Created: 2012-09-04 11:38:23
Document Modified: 2012-09-04 11:38:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC