User Manual

FCC ID: ST2-2X75Y

Users Manual

Download: PDF
FCCID_1580049

                                                                 CenTrak Alert Tag IT‐753*
                                                                 •      Audible Sound Alert Capability
                                                                 •      LED Flash Alert Capability
                                                                 •      Staff Duress Call
                                                                 •      Designed for use with the CenTrak Hand Hygiene
                                                                        Compliance System
                                                                 •      Attaches to a standard hospital issued ID Badge
                                                                 •      CenTrak Hybrid RTLS Technology for room and bed‐level
                                                                        accuracy


                                                                 The Alert Tag (IT‐753) has the capability of alerting with audible sound. The
           IT‐753 CenTrak Alert Tag                              Alert Tag is available with a staff badge holder and comes standard with 1
                                                                 programmable button.

                                                                 This tag was developed to work along with the Hygiene Monitor as part of the
                                                                 CenTrak Hand Hygiene Compliance System, but can also be used for solutions
                                                                 such as staff locating, staff duress call and workflow optimization. When used
                                                                 for hand hygiene compliance, it works as a proactive reminder to caregivers of
                                                                 non‐compliance events; the system automatically captures a specific
                                                                 caregiver’s badge ID and entry to and exit from patient care areas along with
                                                                 hand hygiene events. The Hygiene Monitor communicates each event to the
                                                                 network and records each caregiver’s compliance performance. All of the
                                                                 recorded data is stored on CenTrak’s local or hosted server and can be
                                                                 accessed by compliance management and reporting solutions. The battery
                                                                 powered Hygiene Monitors can be mounted to any dispenser, canister, pump,
                                                                 or sink to track their usage.
       IT‐753 CenTrak Alert Tag shown
       with attachment accessories                               About CenTrak Hybrid RTLS Technology™
                                                                 The CenTrak core RTLS differs from legacy in its combined use of a patented
                                                                 second‐generation infrared (Gen2IR™) and active RFID technology. Battery‐
                                                                 powered Monitors transmit a unique room number using Gen2IR which is
                                                                 received by any tag in that room. The tag communicates the room number and
                                                                 its own unique ID via RF to the CenTrak Location Server using a hospital’s
                                                                 existing wired or WiFi network, where it can be accessed in real‐time by
                                                                 hospital personnel and integrated with third party solution providers.

                                                                 Similar to light, Gen2IR will not pass through walls and does not suffer from
                                                                 traditional infrared lin‐of‐sight limitations. Therefore, when a tag reads a room
                                                                 number, there are no errors. This is certainty‐based RTLS. Unlike estimation‐
                                                                 based information, certainty based location data can be used by hospitals to
                                                                 make important improvements to process flow and automate decision making.
       CenTrak, Inc.                                             Most healthcare workflow improvements can only be realized when the
       5 Caufield Place, Suite 102                               location data is certainty‐based.
       Newtown, PA 18940
                                                                 *IT‐753 is for use with the CenTrak 2.0 system. Order IT‐751 for use with the 1.0
       t: 215‐860‐2928                                           system.
       e: sales@centrak.com
       www.centrak.com



© CenTrak 2011. All Rights Reserved. Proprietary and Confidential. 10/24/11


                                                              CenTrak Staff Badge IT‐743*
                                                              Technical Specifications
                                                                 Operation
                                                                 FCC Operating Frequency Range                         902‐928 MHz (Model #IT‐753)*

                                                                 CE Operating Frequency Range                          868‐870 MHz (Model #ITEU‐753)*

                                                                 Group code & tag ID codes                             2M codes

                                                                 Outdoor transmission range                            > 300 feet

                                                                 Average transmission power                            2 uW (average)

                                                                 Smart tag features                                    1 button, LED, low battery

                                                                 Motion Sensor                                         YES
           IT‐753 CenTrak Alert Tag
                                                                 Attachment Options
                                                                 Clip‐on back attachment                               Clip attaches to lanyard or clothing (pocket,
                                                                                                                       shirt, jacket)

                                                                 Tag Dimensions
                                                                 Case width                                            1.5 in (38.48 mm)

                                                                 Case height                                           1.98 in (50.36 mm)

                                                                 Case width                                            0.6 in (15 mm)

                                                                 Case weight                                           (with battery) 1.1 oz (34.02 g)

                                                                 Construction                                          Heat reflective poly carbonate


                                                                 Environmental
                                                                 Operating Temperature                                 0 C to +70 C

                                                                 Storage temperature                                   ‐25 C to +80 C

                                                                 Sealing                                               Splash resistant

                                                                 Power
                                                                 Battery type                                          Lithium CR2340

                                                                 Smart tag feature                                     Low battery indication


                                                              Note: Must use CenTrak Disinfection procedure. Other methods may void product warranty.
       CenTrak, Inc.                                          *IT‐753 is for use with the CenTrak 2.0 system. Order IT‐751 for use with the 1.0 system.
       5 Caufield Place, Suite 102
       Newtown, PA 18940                                      This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The
                                                              device may not cause harmful interference, and 2) this device must accept any interference received, including
       t: 215‐860‐2928                                        interference that may cases undesired operation. Modifying or tampering with the tranceiver’s or receiver’s internal
                                                              components can cause a malfunction, invalidate the warranty, and will voide FCC authorization to use these products.
       e: sales@centrak.com                                   This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964.
       www.centrak.com                                        L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de
                                                              brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce
                                                              brouillage est susceptible de compromettre le fonctionnement du dispositif.




© CenTrak 2011. All Rights Reserved. Proprietary and Confidential. 10/24/11



Document Created: 2011-11-09 22:09:58
Document Modified: 2011-11-09 22:09:58

© 2024 FCC.report