Test report Bluetooth - HR1956-2 plots

FCC ID: SSVNAEPI02

Test Report

Download: PDF
FCCID_4191800

                                  Annex 1: Measurement diagrams to
                                   PARTIAL T E S T R E P O R T
                                       No.: 18-1-0210201T03a
                                                             According to:

                                                          FCC Regulations
                                                 Part 15.205, Part 15.209, Part 15.247

                                                        ISED-Regulations
                                                 RSS-Gen, Issue 5, RSS-247, Issue 2




                                                                 for

                                                    Miele & Cie. KG


                                         Wireless Food Probe System
                                              (Host: HR1956-2)


                                         Contains FCC ID: SSVNAEPI02
                                         Contains ISED: 5669B-NAEPI02
                                             Laboratory Accreditation and Listings




                                                    Accredited EMC-Test Laboratory




                                       accredited according to DIN EN ISO/IEC 17025

                                                        CETECOM GmbH
                                Laboratory Radio Communications & Electromagnetic Compatibility
                                            Im Teelbruch 116 • 45219 Essen • Germany
                                   Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                     E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 21
The test results relate only to the individual items that have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Annex 1 to Test Report 18-1-0210201T03a, Page 2 of 21


TABLE OF CONTENTS:
1. CONDUCTED EMISSIONS ON AC-POWER LINES ............................................................................................................................ 3
2. CONDUCTED MEASUREMENTS ........................................................................................................................................................... 4
   2.1. Conducted Power .................................................................................................................................................................................... 4
   2.2. Time of Channel Occupancy................................................................................................................................................................... 7
3. RADIATED FIELD STRENGTH MEASUREMENTS.......................................................................................................................... 13
   3.1. Radiated Field Strength Emissions - 9kHz to 30MHz........................................................................................................................... 13
   3.2. Radiated Field Strength Emissions - 30MHz to 1GHz .......................................................................................................................... 14
   3.3. Radiated Field Strength Emissions - 1GHz to 18GHz .......................................................................................................................... 15
   3.4. Radiated Field Strength Emissions - 18GHz to 26.5GHz ..................................................................................................................... 17
   3.5. Radiated Band-Edge Measurements ..................................................................................................................................................... 18




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 3 of 21


1. Conducted emissions on AC-Power lines
                                1.01
Common Information
  Test Description:                                Conducted Voltage Measurement Class B
  Test Site & Location:                            Conducted Emission, CETECOM GmbH Düsseldorf
  Test Software:                                   R&S EMC32 v9.15
  Test Specification:                              FCC 15.207 , RSS 247
  Operating Mode:                                  Oven heating up
  Measured on line:                                120V AC N/L1
  Diagram details:                                 Shows the peak values as a sum of measured ports in maxhold mode
  Environmental Conditions:                        Temperature: 20.5°C; Pressure: 997hPa; Huminity: 45%
  Operator:                                        MAh

EUT Information
  Manufacturer:                                    Miele &Cie KG
  EUT Model:                                       HR1956-2
  HW:                                              Pre Production B0 Series
  SW;                                              Pre Production B0 Series
  Serial Nr.:                                      153703216
         Level in dBµV




     Frequency           QuasiPeak     Average        Limit     Margin        Meas.    Bandwidth      Line      PE    Corr.
       (MHz)              (dBµV)       (dBµV)        (dBµV)      (dB)         Time       (kHz)                        (dB)
                                                                              (ms)
          1.002000            40.84          ---        56.00      15.16      1000.0         9.000   L1       GND       0.2
          1.248000            42.01          ---        56.00      13.99      1000.0         9.000   N        GND       0.2
         11.826000               ---      16.88         50.00      33.12      1000.0         9.000   N        GND       0.7
         11.826000            29.66          ---        60.00      30.34      1000.0         9.000   N        GND       0.7
         15.687000            47.90          ---        60.00      12.10      1000.0         9.000   L1       GND       0.9
         15.687000               ---      37.80         50.00      12.20      1000.0         9.000   L1       GND       0.9




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 4 of 21


2. Conducted Measurements
2.1. Conducted Power

Peak output power (Sweep) (2401,62 MHz; 20,000 dBm; 133 kHz; Test Mode)

Test according to FCC title 47 part 15 §15.247(b), ANSI C63.10


Measurement uncertainty calculated in accordance with ETSI TR 100 028-1.
Expanded Combined Uncertainty of absolute Level Measurement (K=2) < 1 dB


Result
     DUT Frequency         Peak Power      Limit Max     Result
        (MHz)                (dBm)           (dBm)
          2401.620000              20.8           21.0   PASS
         Level in dBm




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 5 of 21

Peak output power (Sweep) (2441,38 MHz; 20,000 dBm; 133 kHz; Test Mode)

Test according to FCC title 47 part 15 §15.247(b), ANSI C63.10


Measurement uncertainty calculated in accordance with ETSI TR 100 028-1.
Expanded Combined Uncertainty of absolute Level Measurement (K=2) < 1 dB


Result
     DUT Frequency         Peak Power      Limit Max     Result
        (MHz)                (dBm)           (dBm)
          2441.380000              20.0           21.0   PASS
         Level in dBm




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 6 of 21



Peak output power (Sweep) (2481,28 MHz; 20,000 dBm; 133 kHz; Test Mode)

Test according to FCC title 47 part 15 §15.247(b)and ANSI C63.10


Measurement uncertainty calculated in accordance with ETSI TR 100 028-1.
Expanded Combined Uncertainty of absolute Level Measurement (K=2) < 1 dB

Result
     DUT Frequency         Peak Power     Limit Max      Result
        (MHz)                (dBm)          (dBm)
          2481.280000               2.2          21.0   PASS
         Level in dBm




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 7 of 21

2.2. Time of Channel Occupancy
2.2.1. Low Channel




                                             DWelltime_low Channel




                                       DWelltime_low Channel_300ms Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 8 of 21




                                        DWelltime_low_Channel_1s_Sweep




                                        DWelltime_low_Channel_24s_Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 9 of 21

2.2.2. Mid Channel




                                             DWelltime_mid Channel




                                       DWelltime_midChannel_300ms_Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 10 of 21




                                        DWelltime_mid_Channel_1s_Sweep




                                       DWelltime_mid_Channel_24s_Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 11 of 21

2.2.3. High Channel




                                            DWelltime_high Channel




                                      DWelltime_high Channel_300ms_Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 12 of 21




                                        DWelltime_highChannel_1s_Sweep




                                        DWelltime_highChannel_24s_Sweep




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 13 of 21


3. Radiated Field Strength Measurements
3.1. Radiated Field Strength Emissions - 9kHz to 30MHz

                                                      2.01
Common Information
 Test description:                     Magnetic Field Strength Measurement related to 30/300 m distance
 Test site and distance:               Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
 Test Location                         Cetecom GmbH Düsseldorf
 Version of Testsoftware:              EMC32 V9.25.0
 Rec. antenna (pre-scan):              height 1.00 m, parallel and 90° to EUT polarisation
 Test specification:                   FCC 15.205 § 15.209; RSS-Gen: Issue 5
 Operator:                             MAh
 Operating conditions:                 Oven heating up, TX-on, Ch low
 Power during tests:                   120V AC

EUT Information
  Manufacturer:                          Miele & Cie KG
  EUT Model:                             HR1956-2
  HW:                                    Pre Production B0 Series
  SW;                                    Pre Production B0 Series
  Serial Nr.:                            153703216
          Level in dBµV/m




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 14 of 21

3.2. Radiated Field Strength Emissions - 30MHz to 1GHz

                                                             3.01
Common Information
  Test description:                             Electric Field Strength Measurement
  Test site and distance:                       Ref.-Nr. 441 Semi Anechoic Chamber 2 (SAC5) with 3m measurement distance
  Test location:                                CETECOM GmbH Düsseldorf
  Version of Testsoftware:                      EMC32 V9.25.0
  Test specification:                           FCC15.109, class B; RSS-Gen.: Issue 5
  Measured sides of EUT:                        front, right, rear, left
  Environmental Conditions:                     Temperature: 20.5°C; Pressure: 997hPa; Huminity: 45%
  Operator:                                     MAh
  Operating conditions:                         Oven heating up, TX-on, Ch low,
  Power during tests:                           120V AC

EUT Information
  Manufacturer:                                 Miele & Cie KG
  EUT Model:                                    HR1956-2
  HW:                                           Pre Production B0 Series
  SW;                                           Pre Production B0 Series
  Serial Nr.:                                   153703216
         Level in dBµV/m




Final_Result
   Frequency               QuasiPeak        Limit      Margin       Bandwidth        Height       Pol   Azimuth    Corr.
     (MHz)                 (dBµV/m)       (dBµV/m)      (dB)          (kHz)           (cm)               (deg)     (dB)

     96.348000                    29.23        43.50      14.27            120.000    100.0   V             80.0     11.3
    129.992000                    33.80        43.50       9.70            120.000    104.0   V             23.0     11.5
    149.992000                    34.55        43.50       8.95            120.000    100.0   V            272.0     10.0
    444.000000                    24.05        46.00      21.95            120.000    113.0   V            355.0     16.3




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 15 of 21

3.3. Radiated Field Strength Emissions - 1GHz to 18GHz

                                                     4.01a
Common Information
  Test description:                      Electric Field Strength Measurement
  Test site and distance:                Ref.-Nr. 441 Semi Anechoic Chamber 2 (SAC5) with 3m measurement distance
  Test location:                         CETECOM GmbH Düsseldorf
  Version of Testsoftware:               EMC32 V9.25.0
  Test specification:                    FCC15.209 / RSS-Gen Issue 5
  Measured sides of EUT:                 front, right, rear, left Height 100-250
  Used filter:                           none up to 3GHz / High Pass from 3GHz
  Environmental Conditions:              Temperature: 20.5°C; Pressure: 997hPa; Huminity: 45%
  Operator:                              MAh
  Operating conditions:                  Oven heating up, TX-on, Ch low,
  Power during tests:                    120V AC

EUT Information
  Manufacturer:                          Miele & Cie KG
  EUT Model:                             HR1956-2
  HW:                                    Pre Production B0 Series
  SW;                                    Pre Production B0 Series
  Serial Nr.:                            153703216
         Level in dBµV/m




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 16 of 21



                                                                    4.01b
Common Information
  Test description:                                     Electric Field Strength Measurement
  Test site and distance:                               Ref.-Nr. 441 Semi Anechoic Chamber 2 (SAC5) with 3m measurement distance
  Test location:                                        CETECOM GmbH Düsseldorf
  Version of Testsoftware:                              EMC32 V9.25.0
  Test specification:                                   FCC15.209 / RSS-Gen Issue 5
  Measured sides of EUT:                                front, right, rear, left
  Used filter:                                          none up to 3GHz / High Pass from 3GHz
  Environmental Conditions:                             Temperature: 20.5°C; Pressure: 997hPa; Huminity: 45%
  Operator:                                             MAh
  Operating conditions:                                 Oven heating up, TX-on, Ch low,
  Power during tests:                                   120V AC

EUT Information
  Manufacturer:                                         Miele & Cie KG
  EUT Model:                                            HR1956-2
  HW:                                                   Pre Production B0 Series
  SW;                                                   Pre Production B0 Series
  Serial Nr.:                                           153703216
         Level in dBµV/m




Final_Result
    Frequency                  MaxPeak             Limit       Margin    Meas. Time           Bandwidth    Azimuth    Corr.
      (MHz)                    (dBµV/m)          (dBµV/m)       (dB)       (ms)                 (kHz)       (deg)     (dB)

      4803.233333                      53.70         74.00        20,3             100.0        1000.000      -35.0    -15.5
      7204.855000                      48.00         74.00       26,00             100.0        1000.000      110.0    -10.9
     14409.695000                      51.91         74.00       22,09             100.0        1000.000        0.0      3.9


Final_Result Average
   Frequency               MaxPeak         DC          Avg          Limit          Margin
     (MHz)                 (dBµV/m)       (dB)      (dBµV/m)      (dBµV/m)          (dB)

     4803.233                  55.51      28,76         24,94            54,00        29,06
     7204.855                  54.33      28,76         19,24            54,00        34,76
    14409.695                  61.60      28,76         23,15            54,00        30,85




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 17 of 21

3.4. Radiated Field Strength Emissions - 18GHz to 26.5GHz

                                                   4.01c




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 18 of 21

3.5. Radiated Band-Edge Measurements
3.5.1. Low Channel 2402.5 MHz (2.4 GHz ISM: left band edge)

                                                     9.01a
Common Information
  Test description:             Band-Edge Electric Field Strength Measurement related to 3m distance
  Test site and distance:       Ref.-Nr. 441x Semi Anechoic Chamber (SAC5) with 3m measurement distance
  Test Location:                CETECOM GmbH Düsseldorf
  Version of Testsoftware:      EMC32 V10.0.0
  Test specification:           FCC15.209 / RSS-Gen Issue 5
  Distance correction:          none
  Operating Mode:               Channel low, Non Hopping Mode on
  Used filter:                  none
  Power during test:            120V AC 60 Hz
  Measured side(s):             front, right, rear, left
  Operator:                     MAh
         Level in dBµV/m




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 19 of 21



                                                     9.02a
Common Information
  Test description:             Band-Edge Electric Field Strength Measurement related to 3m distance
  Test site and distance:       Ref.-Nr. 441x Semi Anechoic Chamber (SAC5) with 3m measurement distance
  Test Location:                CETECOM GmbH Düsseldorf
  Version of Testsoftware:      EMC32 V10.0.0
  Test specification:           FCC15.209 / RSS-Gen Issue 5
  Distance correction:          none
  Operating Mode:               Channel low, Hopping Mode on
  Used filter:                  none
  Power during test:            120V AC 60 Hz
  Measured side(s):             front, right, rear, left
  Operator:                     MAh




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 20 of 21

3.5.2. High Channel 2471.5 MHz ( 2.4 GHz ISM: right band edge)

                                                     9.01b
Common Information
  Test description:             Band-Edge Electric Field Strength Measurement related to 3m distance
  Test site and distance:       Ref.-Nr. 441x Semi Anechoic Chamber (SAC5) with 3m measurement distance
  Test Location:                CETECOM GmbH Düsseldorf
  Version of Testsoftware:      EMC32 V10.0.0
  Test specification:           FCC15.209 / RSS-Gen Issue 5
  Distance correction:          none
  Operating Mode:               Channel high, non Hopping Mode on,
  Used filter:                  none
  Power during test:            120V AC 60 Hz
  Measured side(s):             front, right, rear, left
  Operator:                     MAh
         Level in dBµV/m




CETECOM_TR18-1-0210201T03a-A1


Annex 1 to Test Report 18-1-0210201T03a, Page 21 of 21



                                                     9.02b
Common Information
  Test description:             Band-Edge Electric Field Strength Measurement related to 3m distance
  Test site and distance:       Ref.-Nr. 441x Semi Anechoic Chamber (SAC5) with 3m measurement distance
  Test Location:                CETECOM GmbH Düsseldorf
  Version of Testsoftware:      EMC32 V10.0.0
  Test specification:           FCC15.209 / RSS-Gen Issue 5
  Distance correction:          none
  Operating Mode:               Channel high, Hopping Mode on,
  Used filter:                  none
  Power during test:            120V AC 60 Hz
  Measured side(s):             front, right, rear, left
  Operator:                     MAh
         Level in dBµV/m




CETECOM_TR18-1-0210201T03a-A1



Document Created: 2019-02-08 15:33:43
Document Modified: 2019-02-08 15:33:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC