Test Report

FCC ID: SS3-WM334R1801

Test Report

Download: PDF
FCCID_3810594

                                               FCC PART 15 B
                                                TEST REPORT
                                                                For

                        SZ DJI TECHNOLOGY CO., LTD
 14th floor, West Wing, Skyworth Semiconductor Design Building NO.18 Gaoxin South 4th Ave,
                                       Nanshan, Shenzhen, Guangdong, China



                                         FCC ID: SS3-WM334R1801


             Report Type:                                          Product Name:

            Original Report                                        P hantom 4 RT K

             Report Number:                 RDG180118003-00A

             Report Date:                   2018-03-07

                                             Jerry Zhang
             Reviewed By:
                                             EMC Manager

                                            Bay Area Compliance Laboratories Corp. (Dongguan)
                                            No.69 Pulongcun, Puxinhu Industry Area,
                                            Tangxia, Dongguan, Guangdong, China
             Test Laboratory:               Tel: +86-769-86858888
                                            Fax: +86-769-86858891
                                            www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used
in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).
This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an
asterisk “*”


 Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG180118003-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................5
  TEST EQUIPMENT LIST .................................................................................................................................................6
  ENVIRONMENTAL CONDITIONS ....................................................................................................................................6
SUMARY OF TEST RESULTS ...................................................................................................................................7
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ..............................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9




FCC Part15B                                                                                                                                               Page 2 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG180118003-00A


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)

                       EUT Name:      Phantom 4 RTK
                       EUT Model:     WM334R
               Rated Input Voltage:   DC15.2V from adapter
                             Model:   PH4C100
      Adapter
                             Input:   AC100-240V 1.4A
    Information
                            Output:   DC17.5V
  The Highest Operating Frequency:    5846.5 MHz
               External Dimension:    29cm(L)*29cm(W)*21cm(H)
                    Serial Number:    180118003
               EUT Received Date:     18.01.18


Objective

This test report is prepared on behalf of SZ DJI TECHNOLOGY CO., LTD In accordance with Part 2,
Subpart J, and Part 15-Subparts A and B of the Federal Communications Commission’s rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class A.


Related Submittal(s)/Grant(s)

FCC Part 15C DTS and Part 15E NII submissions with FCC ID: SS3-WM334R1801.
Part of system submissions with FCC ID: SS3-GL300N1801.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).




FCC Part15B                                                                                Page 3 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG180118003-00A

Measurement Uncertainty

                Parameter                              Measurement Uncertainty
                                           30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
       Unwanted Emissions, radiated         200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
                                                 1G~6GHz: 4.45 dB, 6G~26.5GHz: 5.23 dB
                Temperature                                        ±1℃
                 Humidity                                           ±5%
   AC Power Lines Conducted Emission                    3.12 dB (150 kHz to 30 MHz)



Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




FCC Part15B                                                                                   Page 4 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG180118003-00A


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in typical use condition:

Mode: Operating
In this mode, the device controlled by remoter and the video transmitted from the EUT to the remoter.


EUT Exercise Software

No software was used during test.


Equipment Modifications

No modification was made to the EUT tested.

Configuration of Test Setup
Operating mode:




FCC Part15B                                                                                  Page 5 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A

Test Equipment List

                                                                               Calibration     Calibration
Manufacturer       Description                Model          Serial Number
                                                                                  Date          Due Date
     R&S             L.I.S.N                 ESH2-Z5           892107/021       2017-09-25     2018-09-25
                    EMI Test
     R&S                                       ESCI              100035          2017-8-4        2018-8-4
                    Receiver
Sunol Sciences      Antenna                    JB3             A060611-3        2017-7-21       2019-7-21
     HP            Amplifier                  8447F           2443A01912        2017-9-5        2018-9-5
    N/A           Coaxial Cable             C-NJNJ-50          C-0400-02        2017-9-5         2018-9-5
    N/A           Coaxial Cable             C-NJNJ-50          C-0075-02        2017-9-5         2018-9-5
    N/A           Coaxial Cable             C-NJNJ-50          C-2200-01        2017-9-5         2018-9-5
                    Spectrum
     R&S                                      FSEM             831259/019       2017-7-18       2018-7-18
                    Analyzer
   TDK RF         Horn Antenna              HRN-0118             130 084         2016-1-5        2019-1-4
     N/A          Coaxial Cable            C-2.4J2.4J-50        C-0700-01       2017-6-27       2018-6-27
    Mini          Pre-amplifier            ZVA-183-S+          5969001149       2017-9-5         2018-9-5
  Ducommun                                                     1007726-02
                  Horn Antenna            ARH-4223-02                           2017-6-16       2020-6-15
 Technolagies                                                     1304
  Ducommun                                                     1007726-01
                  Horn Antenna            ARH-2823-02                           2016-11-18      2019-11-18
 Technolagies                                                     1302
   Quinstar         Amplifier           QLW-18405536-JO       15964001001       2017-6-27       2018-6-27
                    Spectrum
     R&S                                      FSP 38             100478         2017-12-08      2018-12-8
                    Analyzer
                  Bandrejector
Chengdu OuLi                                5725-5850             005            2017-9-5        2018-9-5
                      Filter
     arad         Test Software              EZ-EMC             V1.1.4.2           N/A             N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
have been performed, traceable to National Primary Standards and International System of Units (SI).


Environmental Conditions

              Temperature:              24~ 27oC
       Relative Humidity:                30~65 %
          ATM Pressure:                100~101 kPa
                                  Vern Shen, Blake Yang,
                    Tester:
                                         Alex You
                 Test Date:        2018.1.26-2018.2.25




FCC Part15B                                                                                    Page 6 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)      Report No.: RDG180118003-00A


SUMARY OF TEST RESULTS
  FCC Part 15B
        Clause                    Description of Test     Test Result
     FCC§15.107                   Conducted emissions   Not Applicable
       §15.109                     Radiated emissions    Compliance


Not Applicable: the device was powered by battery.




FCC Part15B                                                              Page 7 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG180118003-00A


FCC §15.109 - RADIATED SPURIOUS EMISSIONS

EUT Setup

Below 1GHz:




Above 1GHz:




The radiated emission Below 1GHz tests were performed in the 10 meters chamber test site, above 1GHz
tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI
C63.4-2014. The specification used was the FCC Part 15.109 Class A limits.




FCC Part15B                                                                             Page 8 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG180118003-00A

EMI Test Receiver Setup

The system was investigated from 30 MHz to 40 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:


               Frequency Range            RBW          Video B/W        IF B/W       Measurement
              30 MHz – 1000 MHz          120 kHz        300 kHz         120 kHz           QP
                                          1 MHz          3 MHz             /             Peak
                 Above 1 GHz
                                          1 MHz          10 Hz             /             AVG



Test Procedure

During the radiated emissions, the adapter of laptop was connected to the first AC floor outlet and the other
support equipments were connected to the second AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection mode
above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

                                  Margin = Limit – Corrected Amplitude




FCC Part15B                                                                                     Page 9 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A


Test Data

Please refer to following table and plots:


Condition:           FCC Class B 3M Radiation                    Polarization:         Horizontal
EUT:                 Phantom 4 RTK                               Power:                DC 15.2V
Model:               WM334R                                      Distance:             3m
Test Mode:           Operating
Note:




 No.     Frequency       Reading        Detector     Corrected       Result         Limit       Margin
           (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)       (dB)
  1
          30.9700         25.55              QP        0.35          25.90          40.00           14.10
  2
          56.1900         42.26              QP       -12.46         29.80          40.00           10.20
  3
          176.4700        40.33              QP        -7.73         32.60          43.50           10.90
  4
          217.2100        48.31              QP        -7.01         41.30          46.00           4.70
  5
          303.5400        42.03              QP        -4.43         37.60          46.00           8.40
  6
          347.1900        40.44          peak          -3.24         37.20          46.00           8.80




FCC Part15B                                                                                  Page 10 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Class B 3M Radiation                    Polarization:         Vertical
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit         Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)         (dB)
  1
         55.2200         38.72          QP           -12.42         26.30          40.00         13.70
  2
         216.2400        40.97          QP            -7.07         33.90          46.00         12.10
  3
         242.4300        38.87          QP            -6.27         32.60          46.00         13.40
  4
         288.0200        40.22          QP            -3.92         36.30          46.00          9.70
  5
         340.4000        40.02          QP            -3.52         36.50          46.00          9.50
  6
         600.3600        33.50          QP            0.20          33.70          46.00         12.30




FCC Part15B                                                                                 Page 11 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Horizontal
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected        Result        Limit           Margin
          (MHz)         (dBμV)                       (dB/m)        (dBμV/m)      (dBμV/m)           (dB)

  1      1067.500        57.84         peak          -10.44         47.40          74.00           26.60
  2      1067.500        47.36         AVG           -10.44         36.92          54.00           17.08
  3      1549.000        62.57         peak           -8.92         53.65          74.00           20.35
  4      1549.000        52.34         AVG            -8.92         43.42          54.00           10.58
  5      2543.500        57.93         peak           -6.05         51.88          74.00           22.12
  6      2543.500        47.54         AVG            -6.05         41.49          54.00           12.51




FCC Part15B                                                                                 Page 12 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Vertical
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit         Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)         (dB)

  1      1432.000        58.44         peak           -9.40         49.04          74.00         24.96
  2      1432.000        47.53         AVG            -9.40         38.13          54.00         15.87
  3      1760.500        61.46         peak           -8.05         53.41          74.00         20.59
  4      1760.500        50.28         AVG            -8.05         42.23          54.00         11.77
  5      1922.500        62.82         peak           -7.46         55.36          74.00         18.64
  6      1922.500        51.64         AVG            -7.46         44.18          54.00          9.82




FCC Part15B                                                                                 Page 13 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Horizontal
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit       Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)       (dB)

  1     14000.000        46.75         peak           9.34          56.09          74.00           17.91
  2     14000.000        35.42         AVG            9.34          44.76          54.00           9.24
  3     14568.000        47.09         peak          10.25          57.34          74.00           16.66
  4     14568.000        36.24         AVG           10.25          46.49          54.00           7.51
  5     17968.000        43.39         peak          16.92          60.31          74.00           13.69
  6     17968.000        32.64         AVG           16.92          49.56          54.00           4.44




FCC Part15B                                                                                 Page 14 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Vertical
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit         Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)         (dB)

  1     14424.000        45.74         peak          10.16          55.90          74.00         18.10
  2     14424.000        35.26         AVG           10.16          45.42          54.00          8.58
  3     14944.000        45.90         peak           9.94          55.84          74.00         18.16
  4     14944.000        35.18         AVG            9.94          45.12          54.00          8.88
  5     17872.000        43.58         peak          16.22          59.80          74.00         14.20
  6     17872.000        33.24         AVG           16.22          49.46          54.00          4.54




FCC Part15B                                                                                 Page 15 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Horizontal
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit       Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)       (dB)

  1     22577.250        56.54         peak           0.00          56.54          74.00           17.46
  2     22577.250        45.62         AVG            0.00          45.62          54.00           8.38
  3     24587.500        56.79         peak           0.00          56.79          74.00           17.21
  4     24587.500        45.68         AVG            0.00          45.68          54.00           8.32
  5     25832.750        58.71         peak           0.00          58.71          74.00           15.29
  6     25832.750        47.45         AVG            0.00          47.45          54.00           6.55




FCC Part15B                                                                                 Page 16 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Vertical
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit         Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)         (dB)

  1     22636.750        57.02         peak           0.00          57.02          74.00         16.98
  2     22636.750        46.31         AVG            0.00          46.31          54.00          7.69
  3     24608.750        58.45         peak           0.00          58.45          74.00         15.55
  4     24608.750        47.68         AVG            0.00          47.68          54.00          6.32
  5     25922.000        59.18         peak           0.00          59.18          74.00         14.82
  6     25922.000        48.36         AVG            0.00          48.36          54.00          5.64




FCC Part15B                                                                                 Page 17 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG180118003-00A


Condition:          FCC Part 15 Class B                         Polarization:          Horizontal
EUT:                Phantom 4 RTK                               Power:                 DC 15.2V
Model:              WM334R                                      Distance:              3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected        Result         Limit           Margin
          (MHz)         (dBμV)                       (dB/m)        (dBμV/m)       (dBμV/m)           (dB)
  1
        38137.000        59.93         peak           0.00           59.93          74.00           14.07
  2
        38137.000        48.65         AVG            0.00           48.65          54.00            5.35




FCC Part15B                                                                                  Page 18 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180118003-00A




Condition:          FCC Part 15 Class B                         Polarization:         Vertical
EUT:                Phantom 4 RTK                               Power:                DC 15.2V
Model:              WM334R                                      Distance:             3m
Test Mode:          Operating
Note:




 No.    Frequency       Reading       Detector      Corrected       Result         Limit         Margin
          (MHz)         (dBμV)                       (dB/m)       (dBμV/m)       (dBμV/m)         (dB)
  1
        38137.000        60.98         peak           0.00          60.98          74.00         13.02
  2
        38137.000        48.63         AVG            0.00          48.63          54.00          5.37



                                   ****END OF REPORT****