FCC ID: SS3-RMTX11510

RF Exposure Info

Download: PDF
FCCID_2819079



                                                                                                           REPORT No.:SZ15090040S05



                                                                DIRECTORY

 TEST REPORT DECLARATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙3


 1. TECHNICAL INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4


 1.1. IDENTIFICATION OF APPLICANT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4
 1.2. IDENTIFICATION OF MANUFACTURER ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4
 1.3. EQUIPMENT UNDER TEST (EUT) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4
 1.3.1. PHOTOGRAPHS OF THE EUT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.3.2. IDENTIFICATION OF ALL USED EUT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6
 1.4. APPLIED REFERENCE DOCUMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6


 2.DEVICE CATEGORY AND RF EXPOSURE LIMIT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7


 3.MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8


 4. RF EXPOSURE EVALUATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8


 ANNEX A GENERAL INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9



                                                                   Change History
  Issue                Date                                                           Reason for change
    1.0           2015-11-06                                                                First edition




MORLAB GROUP
                                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                                           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                                  Page 2 0f 9




                                                                                            REPORT No.:SZ15090040S05



 1. TECHNICAL INFORMATION
 Note: the following data is based on the information by the applicant.

 1.1. Identification of Applicant
 Company Name:               SZ DJI TECHNOLOGY CO., LTD
 Address:                    14th floor, West Wing, Skyworth Semiconductor Design Building
                             NO.18 Gaoxin South 4th Ave, Nanshan District, Shenzhen, China

 1.2. Identification of Manufacturer
 Company Name:               SZ DJI TECHNOLOGY CO., LTD
 Address:                    14th floor, West Wing, Skyworth Semiconductor Design Building
                             NO.18 Gaoxin South 4th Ave, Nanshan District, Shenzhen, China

 1.3. Equipment Under Test (EUT)
 Model Name:                 RM-TX1
 Trade Name:                 DJI
 Brand Name:                 DJI
 Hardware Version:           V1.0
 Software Version:           V1.0
 Frequency Bands:            Tx:2145-2473MHz;
 Modulation Mode:            2.4GHz: GFSK;
 Antenna type:               Fixed Internal Antenna
 Development Stage:          Identical prototype




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                   Page 4 0f 9


                                                                                         REPORT No.:SZ15090040S05



 1.3.1. Photographs of the EUT


 1.   EUT front view




 2.   EUT rear view




MORLAB GROUP
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                Page 5 0f 9


                                                                                            REPORT No.:SZ15090040S05



 1.3.2. Identification of all used EUT

 The EUT identity consists of numerical and letter characters, the letter character indicates the test
 sample, and the following two numerical characters indicate the software version of the test
 sample.


               EUT
                            Hardware Version                                         Software Version
             Identity
                   1#                   V1.0                                                 V1.0


 1.4. Applied Reference Documents
 Leading reference documents for testing:
 No.    Identity                            Document Title
 1      47 CFR§2.1093                       Radiofrequency Radiation Exposure Evaluation: portable
                                            devices
 2      KDB 447498 D01v05r02                General RF Exposure Guidance




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                   Page 6 0f 9


                                                                                             REPORT No.:SZ15090040S05



 2. DEVICE CATEGORY AND RF EXPOSURE LIMIT

 Per user manual, this device is a control remote. Based on 47CFR 2.1093, this device belongs to
 portable device category with General Population/Uncontrolled exposure.
 Portable Devices:
 47CFR 2.1093(b)
 For purposes of this section, a portable device is defined as a transmitting device designed to be
 used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the
 user.

 GENERAL POPULATION / UNCONTROLLED EXPOSURE
 47CFR 2.1093(d) (2)
 Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body
 and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a
 tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the
 spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a
 tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the
 general public may be exposed, or when persons that are exposed as a consequence of their
 employment may not be fully aware of the potential for exposure or do not exercise control over
 their exposure. Warning labels placed on consumer devices such as cellular telephones will not be
 sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled
 exposure in paragraph (d)(1) of this section.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                    Page 7 0f 9


                                                                                            REPORT No.:SZ15090040S05



 3. MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER
 1. 2.4GHz Average output power


                                                                                          Output
                                                           Frequency                    Power(dBm)
                       Band            Channel
                                                             (MHz)
                                                                                            GFSK
                                             1                  2145                        6.89
                      2.4GHz                15                  2443                        6.56
                                            30                  2473                        4.35



 4. RF EXPOSURE EVALUATION
 The device only incorporates a Bluetooth transmitter, so standalone SAR evaluation is required for
 Bluetooth and simultaneous SAR is not required.

 Standalone transmission SAR evaluation

 According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation
 Distances ≤ 50 mm are determined by:
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] ≤ 3.0
 The maximum tune-up limit power is 5.01mW @ 2.402GHz
 This device is a control remote,use 10mm as the most conservative minimum test separation
 distance,
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] =0.78 ≤ 3.0

 So SAR evaluation is not required for this device.




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                   Page 8 0f 9


                                                                                          REPORT No.:SZ15090040S05




 ANNEX A GENERAL INFORMATION

 1. Identification of the Responsible Testing Laboratory
  Company Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                               Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China
  Responsible Test Lab Manager:             Mr. Su Feng
  Telephone:                                +86 755 36698555
  Facsimile:                                +86 755 36698525


 2. Identification of the Responsible Testing Location
  Name:                                     Shenzhen Morlab Communications Technology Co., Ltd.
                                            Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China



                                    ***** END OF REPORT *****




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 9 0f 9