Test Report

FCC ID: SS3-RMS11902

Test Report

Download: PDF
FCCID_4313666

                                              FCC PART 15 B
                                               TEST REPORT
                                                              For

                       SZ DJI TECHNOLOGY CO., LTD
 14th floor, West Wing, Skyworth Semiconductor Design Building NO.18 Gaoxin South 4th Ave,
                                      Nanshan, Shenzhen, Guangdong, China



                                           FCC ID: SS3-RMS11902


            Report Type:                                         Product Type:

            Original Report                                      RoboMaster S1

            Report Number:                 RDG190215001-00A

            Report Date:                   2019-03-06

                                           Jerry Zhang
            Reviewed By:
                                           EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
            Test Laboratory:               Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used
by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This
report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


 Bay Area Compliance Laboratories Corp. (Dongguan)                                                                        Report No.: RDG190215001-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ..............................................................................................7
  EUT SETUP ..................................................................................................................................................................7
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  TEST PROCEDURE ........................................................................................................................................................8
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST DATA ..................................................................................................................................................................9




                                                                                                                                                            Page 2 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190215001-00A


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)

                           EUT Name:     RoboMaster S1
                          EUT Model:     RMS1
         Highest Operating Frequency:    5825MHz
                  Rated Input Voltage:   DC 10.8V from battery
                  External Dimension:    320mm(L)* 240mm(W)* 270mm(H)
                       Serial Number:    190215001
                  EUT Received Date:     2019-02-08


Objective

This test report is prepared on behalf of SZ DJI TECHNOLOGY CO., LTD in accordance with Part 2, Subpart
J, and Part 15-Subparts A and B of the Federal Communications Commission’s rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class B.


Related Submittal(s)/Grant(s)

FCC Part 15C DTS submissions with FCC ID: SS3-RMS11902.
FCC Part 15E NII submissions with FCC ID: SS3-RMS11902.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).




                                                                                            Page 3 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190215001-00A


Measurement Uncertainty


                Parameter                                Measurement Uncertainty
                                       30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
       Unwanted Emissions, radiated
                                          6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
                Temperature                                        ±1℃
               Humidity                                            ±5%
   AC Power Lines Conducted Emission                    3.12 dB (150 kHz to 30 MHz)



Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                            Page 4 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190215001-00A


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing inOperating mode, in this mode, the EUT was controlled by remote
controller: C4, shooting Video, trasmitting the video data to C4 and recording the data to the SD card.


EUT Exercise Software

The software “DJI RoboMaster.app” installed in the phone was used during test.


Equipment Modifications

No modification was made to the EUT tested.


Local Support Equipment List and Details

        Manufacturer             Description            Model                    Serial Number
                              Remote Controller
             DJI                                       GD0MA                           /
                                    C4
           APPLE                    Phone            MGAA2CG/A              FK1R96UYG5QT



Configuration of Test Setup




                                                                                                 Page 5 of 17


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG190215001-00A


SUMMARY OF TEST RESULTS

          FCC Rules                         Description of Test              Results

            §15.107                         Conducted Emissions           Not Aplicable*

            §15.109                          Radiated Emissions            Compliance

Note:
Not Aplicable*: The EUT was powered by battery.




                                                                                       Page 6 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190215001-00A


FCC §15.109 - RADIATED SPURIOUS EMISSIONS

EUT Setup

Below 1GHz:




Above 1GHz:




The radiated emission below 1GHz tests were performed in the 3 meters chamber test site A, above 1GHz
tests were performed in the 3 meters chamber test site B, 1GHz-26.5GHz were performed at the 3 m distance
and 26.5-40 GHz was performed at 1 m distance, using the setup accordance with the ANSI C63.4-2014.
The specification used was with the FCC Part 15 B Class B limits.




                                                                                             Page 7 of 17


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190215001-00A

EMI Test Receiver Setup
The system was investigated from 30 MHz to 40 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

              Frequency Range             RBW          Video B/W        IF B/W      Measurement
            30 MHz – 1000 MHz           120 kHz         300 kHz         120 kHz          QP
                                         1 MHz           3 MHz             /            Peak
                Above 1 GHz                             Reduced
                                         1 MHz            video            /            AVG
                                                       bandwidth

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.

Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection mode
above 1 GHz.

According to C63.4, the above 1G test result shall be extrapolated to the specified distance using an
extrapolation factor of 20dB/decade from 3m to 1 m
Distance extrapolation factor =20 log (specific distance [3m]/test distance [1m]) dB= 9.54 dB


Corrected Amplitude & Margin Calculation

The basic equation is as follows:

Result = Meter Reading+ Corrected

Note:
Corrected = Antenna Factor + Cable Loss - Amplifier Gain
or
Corrected = Antenna Factor + Cable Loss + Distance extrapolation factor - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
                                          Margin = Limit – Result




                                                                                                Page 8 of 17


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190215001-00A

Test Equipment List and Details

                                                                       Serial      Calibration    Calibration
    Manufacturer          Description                Model
                                                                     Number           Date         Due Date
         R&S           EMI Test Receiver               ESCI           100224       2018-12-10     2019-12-10
        Farad            Test Software               EZ-EMC          V1.1.4.2         N/A            N/A
    Sunol Sciences          Antenna                    JB3          A060611-1      2017-11-10     2020-11-10
       Unknown           Coaxial Cable              C-NJNJ-50       C-0400-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable              C-NJNJ-50       C-0075-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable              C-NJNJ-50       C-1400-01      2018-05-06     2019-05-06
          HP               Amplifier                  8447D        2727A05902      2018-09-05     2019-09-05
        Agilent        Spectrum Analyzer             E4440A        SG43360054      2019-01-04     2020-01-04
         R&S           Spectrum Analyzer              FSP 38          100478       2018-12-10     2019-12-10
    ETS-Lindgren         Horn Antenna                  3115         000 527 35     2018-10-12     2021-10-12
      Ducommun                                                     1007726-01
                         Horn Antenna          ARH-4223-02                          2016-11-18    2019-11-18
     Technolagies                                                      1304
      Ducommun                                                     1007726-01
                         Horn Antenna          ARH-2823-02                          2016-11-18    2019-11-18
     Technolagies                                                      1302
       Unknown           Coaxial Cable          C-SJSJ-50           C-0800-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable         C-2.4J2.4J-50        C-0700-02      2018-06-27     2019-06-27
                                             AFS42-00101800-2
        MITEQ              Amplifier                                 2001271       2018-09-05     2019-09-05
                                                  5-S-42
       Quinstar            Amplifier         QLW-18405536-JO       15964001001     2018-06-27     2019-06-27

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

    Environmental Conditions


             Temperature:                 23.5 C
         Relative Humidity:                60 %
            ATM Pressure:                100.5 kPa

     * The testing was performed by Kami Zhou & Tyler Pan on 2019-02-28.

     Test Result: Compliance




                                                                                                    Page 9 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

Test Mode: Operating

1) Below 1GHz:

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    30.9700         27.83          peak             0.91     28.74          40.00        11.26
    131.8500        40.15           QP              -4.89    35.26          43.50        8.24
    184.2300        42.60           QP              -7.38    35.22          43.50        8.28
    353.0100        39.50          peak             -2.93    36.57          46.00        9.43
    395.6900        38.26          peak             -2.07    36.19          46.00        9.81
    660.5000        35.35          peak             2.15     37.50          46.00        8.50




                                                                                        Page 10 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    30.9700         27.66          peak             0.91     28.57          40.00        11.43
    98.8700         41.80          peak             -9.20    32.60          43.50        10.90
    131.8500        36.94          peak             -4.89    32.05          43.50        11.45
    173.5600        38.47          peak             -6.85    31.62          43.50        11.88
    393.7500        37.31          peak             -2.14    35.17          46.00        10.83
    498.5100        36.12          peak             -0.31    35.81          46.00        10.19




                                                                                        Page 11 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

2) Above 1GHz:

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    8956.000        45.55          peak             6.18     51.73          74.00        22.27
    8956.000        32.72          AVG              6.18     38.90          54.00        15.10
   14209.000        49.53          peak             9.74     59.27          74.00        14.73
   14209.000        36.27          AVG              9.74     46.01          54.00         7.99
   18000.000        43.63          peak             17.15    60.78          74.00        13.22
   18000.000        30.57          AVG              17.15    47.72          54.00         6.28




                                                                                        Page 12 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    14447.000       49.65          peak             10.21    59.86          74.00        14.14
    14447.000       36.58          AVG              10.21    46.79          54.00         7.21
    17617.500       46.45          peak             14.39    60.84          74.00        13.16
    17617.500       33.42          AVG              14.39    47.81          54.00         6.19
    18000.000       44.43          peak             17.15    61.58          74.00        12.42
    18000.000       30.75          AVG              17.15    47.90          54.00         6.10




                                                                                        Page 13 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   26500.000        38.77          peak             21.84    60.61          74.00        13.39
   26500.000        25.14          AVG              21.84    46.98          54.00         7.02




                                                                                        Page 14 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    26448.898       39.57          peak             21.61    61.18          74.00        12.82
    26448.898       26.12          AVG              21.61    47.73          54.00         6.27




                                                                                        Page 15 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   40000.000        42.77          peak             15.97    58.74          74.00        15.26
   40000.000        30.41          AVG              15.97    46.38          54.00         7.62




                                                                                        Page 16 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190215001-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    39379.000       42.83          peak             16.02    58.85          74.00        15.15
    39379.000       30.15          AVG              16.02    46.17          54.00         7.83

                                   ****END OF REPORT****