Test Report

FCC ID: SS3-PS512M21610

Test Report

Download: PDF
FCCID_3205400

                                         FCC PART 15 B
                                          TEST REPORT
                                                         For

                      SZ DJI TECHNOLOGY CO., LTD
 14th floor, West Wing, Skyworth Semiconductor Design Building NO.18 Gaoxin South 4th Ave,
                           Nanshan, Shenzhen, Guangdong, China


                                  FCC ID: SS3-PS512M21610


           Repo rt Typ e:                            Pro duct Na me:
           Orig inal Repor t                         DJI CINESSD STATION




                  Test Engineer:        Kevin Hu


                Report Number:         RDG161009004


                    Report Date:       2016-11-11

                                        Henry Ding
                                        EMC Leader
                   Reviewed By:

                                       Bay Area Compliance Laboratories Corp. (Chengdu)
               Test Laboratory:
                                        5040, HuiLongWan Plaza, No. 1, ShaWan Road,
                                        JinNiu District, ChengDu, China
                                        Tel: 028-65523123, Fax: 028-65525125
                                        www.baclcorp.com



Note: This test report was prepared for the customer shown above and for the device described herein. It may not be
      duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Chengdu).
      Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
      offenders may be prosecuted to the fullest extent of the law. This report was valid only with a valid digital
      signature.


 Bay Area Compliance Laboratories Corp. (Chengdu)




                                                       TABLE OF CONTENTS

GENERAL INFORMATION ........................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................................3
 OBJECTIVE ..................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................3
 TEST METHODOLOGY .................................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ...........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................5
  EUT EXERCISE SOFTWARE ........................................................................................................................................5
  EQUIPMENT MODIFICATIONS ......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ......................................................................................................5
  SUPPORT CABLE LIST AND DETAILS...........................................................................................................................5
  CONFIGURATION OF TEST SETUP...............................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.107 - CONDUCTED EMISSIONS ..............................................................................................................8
  MEASUREMENT UNCERTAINTY ...................................................................................................................................8
  EUT SETUP .................................................................................................................................................................8
  EMI TEST RECEIVER SETUP ......................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................9
  TEST PROCEDURE ......................................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ..........................................................................................13
  MEASUREMENT UNCERTAINTY .................................................................................................................................13
  EUT SETUP ...............................................................................................................................................................13
  EMI TEST RECEIVER SETUP ....................................................................................................................................14
  TEST PROCEDURE ....................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .......................................................................................................................15
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
  TEST DATA ................................................................................................................................................................15




Report No.: RDG161009004                                                                                                                            Page 2 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)
The SZ DJI TECHNOLOGY CO., LTD ’s product, model number: PS512M2 (FCC ID:
SS3-PS512M21610) (the "EUT") in this report was a DJI CINESSD, which was measured
approximately: 10.4 cm (L) × 2.6 cm (W) × 0.6 cm (H), rated input voltage: DC 3.3V from DJI
CINESSD STATION. The highest operating frequency is 600MHz.

 *All measurement and test data in this report was gathered from final production sample, serial number:
 161009004 (assigned by the BACL, Chengdu). It may have deviation from any other sample. The EUT
 supplied by the applicant was received on 2016-10-08, and EUT conformed to test requirement.


Objective

This test report is prepared on behalf of SZ DJI TECHNOLOGY CO., LTD in accordance with Part
2, Subpart J, and Part 15-Subparts A and B of the Federal Communications Commission’s rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class
B.


Related Submittal(s)/Grant(s)

Submitted with the Part of a system with FCC ID: SS3-PR05GU31610.




Report No.: RDG161009004                                                                Page 3 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American
National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz.

The uncertainty of any RF tests which use conducted method measurement is ±3.17 dB, the
uncertainty of any radiation on emissions measurement is:

30M~200MHz: ±4.7 dB;
200M~1GHz: ±6.0 dB;
1G-6GHz: ±5.13dB;
6G~25GHz: ±5.47dB;

And the uncertainty will not be taken into consideration for all test data recorded in the report.


Test Facility

The test site used by BACL to collect test data is located in the 5040, HuiLongWan Plaza, No. 1,
ShaWan Road, JinNiu District, ChengDu, China

Test site at BACL has been fully described in reports submitted to the Federal Communication
Commission (FCC). The details of these reports have been found to be in compliance with the
requirements of Section 2.948 of the FCC Rules on April 24, 2015. The facility also complies with
the radiated and AC line conducted test site criteria set forth in ANSI C63.4-2014.

The Federal Communications Commission has the reports on file and is listed under FCC
Registration No.: 560332. The test site has been approved by the FCC for public use and is listed
in the FCC Public Access Link (PAL) database.




Report No.: RDG161009004                                                               Page 4 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software

The software “Burn In” was used during test.


Equipment Modifications

No modification was made to the EUT tested.


Local Support Equipment List and Details

      Manufacturer               Description           Model                Serial Number
         IBM                          PC                8176                   99Y7315
         DELL                       Display           E157FPC                 060229-11
        ANTER                       Modem             EGW802                0508350054-1B
        Lenovo                     Keyboard          KB-US19EB           IMHYX011071016460
        Lenovo                      Mouse            MO-5013U             IMJS011041409259
          DJI               DJI CINESSD STATION       PR05GU3                    N/A


Support Cable List and Details

                       Shielding                   Length
 Cable Description                  Ferrite Core                   From Port              To
                         Type                       (m)
    Serial Cable           yes           No           1.6       Serial Port of PC      Modem
    Mouse Cable            yes           No           1.4      Parallel Port of PC      Mouse
  Keyboard Cable           yes           No           1.3       USB Port of PC        Keyboard
   D-SUB Cable             yes           yes          1.8      D-SUB Port of PC         Display
                                                                                     DJI CINESSD
     USB Cable             yes           No           0.5       USB Port of PC
                                                                                       STATION




Report No.: RDG161009004                                                             Page 5 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Configuration of Test Setup




Report No.: RDG161009004                           Page 6 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)


SUMMARY OF TEST RESULTS


        FCC Rules                     Description of Test    Results

          §15.107                    Conducted Emissions    Compliance

          §15.109                     Radiated Emissions    Compliance




Report No.: RDG161009004                                         Page 7 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)


FCC§15.107 - CONDUCTED EMISSIONS

Measurement Uncertainty

All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are Receiver, cable loss, and LISN.

Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds
the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2:2011, measurement uncertainty of conducted disturbance at mains port using
AMN at Bay Area Compliance Laboratories Corp. (Chengdu) is ±3.17 dB (150 kHz to 30 MHz).

                                      Table 1 – Values of Ucispr

                              Measurement                                          Ucispr
Conducted disturbance at mains port using AMN (150 kHz to 30 MHz)                  3.4 dB



EUT Setup




Report No.: RDG161009004                                                               Page 8 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The
specification used was with the FCC Part 15 B Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in
the middle.

The DJI CINESSD STATION from PC was connected to a 120V/60Hz AC power source.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                             Frequency Range                      IF B/W
                             150 kHz – 30 MHz                      9 kHz



Test Equipment List and Details

                                                            Serial         Calibration   Calibration
     Manufacturer         Description        Model
                                                           Number             Date        Due Date
                           EMI Test
   Rohde & Schwarz                          ESCS 30      836858/0016       2015-12-02    2016-12-01
                           Receiver
   Rohde & Schwarz         L.I.S.N.         ENV216       3560.6550.06      2015-12-02    2016-12-01

   Rohde & Schwarz     PULSE LIMITER        ESH3Z2       357.8810.52       2015-10-31    2016-10-30
         N/A           Conducted Cable       NO.5            N/A           2015-11-10    2016-11-09

* Statement of Traceability: BACL (Chengdu) attested that all calibrations have been performed, traceable
to National Primary Standards and International System of Units (SI).


Test Procedure

During the conducted emission test, the adapter of laptop was connected to the outlet of the first
LISN and the other support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation

The basic equation is as follows:

VC = VR + AC + VDF


Report No.: RDG161009004                                                                 Page 9 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Herein,
VC: corrected voltage amplitude

VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the maximum
limit. The equation for margin calculation is as follows:

       Margin = Limit – Corrected Amplitude


Test Data

    Environmental Conditions

            Temperature:           30.1 °C
       Relative Humidity:           48 %
          ATM Pressure:           101.2 kPa

     The testing was performed by Kevin Hu on 2016-10-28.




Report No.: RDG161009004                                                        Page 10 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Mode: Read

AC120V, 60Hz, Line:


                       100


                       80
       Level in dB 礦




                                                                                             Quasi-Peak Limit
                       60
                                                                                               Average Limit

                       40


                       20


                        0
                        150k      300 400500     800 1M        2M    3M 4M 5M 6      8 10M        20M    30M
                                                           Frequency in Hz




    Frequency                  QuasiPeak       Bandwidth             Corr.   Margin      Limit
                                                             Line                                    Comment
       (MHz)                    (dBμV)           (kHz)               (dB)     (dB)      (dBμV)
     0.158948                     58.2           9.000        L1     18.8      7.3        65.5      Compliance
     1.153547                     44.7           9.000        L1     20.0     11.3        56.0      Compliance
     1.300465                     46.9           9.000        L1     20.0      9.1        56.0      Compliance
     1.348086                    48.4            9.000        L1      20.0     7.6       56.0       Compliance
     1.372546                    44.3            9.000        L1      20.0    11.7       56.0       Compliance
     1.419967                    43.0            9.000        L1      20.0    13.0       56.0       Compliance

    Frequency                   Average        Bandwidth             Corr.   Margin      Limit
                                                             Line                                    Comment
       (MHz)                    (dBμV)           (kHz)               (dB)     (dB)      (dBμV)
     0.157368                     49.5           9.000        L1     18.8      6.1        55.6      Compliance
     0.632195                     40.3           9.000        L1     20.0      5.7        46.0      Compliance
     0.711290                     39.1           9.000        L1     19.9      6.9        46.0      Compliance
     1.106148                     39.5           9.000        L1     19.9      6.5        46.0      Compliance
     1.264592                     39.9           9.000        L1     20.0      6.1        46.0      Compliance
     1.737473                     35.5           9.000        L1     20.0     10.5        46.0      Compliance




Report No.: RDG161009004                                                                             Page 11 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

AC120V, 60Hz, Neutral:


                       100


                       80
       Level in dB 礦




                                                                                             Quasi-Peak Limit
                       60
                                                                                               Average Limit

                       40


                       20


                        0
                        150k      300 400500     800 1M        2M    3M 4M 5M 6      8 10M        20M    30M
                                                           Frequency in Hz




    Frequency                  QuasiPeak       Bandwidth             Corr.   Margin      Limit
                                                             Line                                    Comment
       (MHz)                    (dBμV)           (kHz)               (dB)     (dB)      (dBμV)
     0.158314                     60.9           9.000        N      18.8      4.7        65.6      Compliance
     0.236555                     52.9           9.000        N      19.1      9.3        62.2      Compliance
     0.316047                     46.5           9.000        N      19.6     13.3        59.8      Compliance
     1.153547                     43.2           9.000        N      20.0     12.8        56.0      Compliance
     1.345395                     47.0           9.000        N      20.0      9.0        56.0      Compliance
     1.417133                    45.4            9.000        N       20.0    10.6       56.0       Compliance

    Frequency                   Average        Bandwidth             Corr.   Margin      Limit
                                                             Line                                    Comment
       (MHz)                    (dBμV)           (kHz)               (dB)     (dB)      (dBμV)
     0.156741                     50.6           9.000        N      18.8      5.0        55.6      Compliance
     0.236555                     44.6           9.000        N      19.1      7.6        52.2      Compliance
     0.551882                     38.8           9.000        N      19.9      7.2        46.0      Compliance
     0.630933                     39.1           9.000        N      19.9      6.9        46.0      Compliance
     0.708453                     39.7           9.000        N      19.9      6.3        46.0      Compliance
     1.179180                     38.2           9.000        N      20.0      7.8        46.0      Compliance




Report No.: RDG161009004                                                                             Page 12 of 17


 Bay Area Compliance Laboratories Corp. (Chengdu)


FCC §15.109 - RADIATED SPURIOUS EMISSIONS

Measurement Uncertainty

Compliance or non- compliance with a disturbance limit shall be determined in the following
manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance
limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab −
Ucispr), exceeds the disturbance limit.

Based on CISPR 16-4-2-2011, measurement uncertainty of radiated emission at a distance of 3m
at Bay Area Compliance Laboratories Corp. (Chengdu) is:
30M~200MHz: ±4.7 dB ;
200M~1GHz: ±6.0 dB ;
1G-6GHz: ±5.13dB;
6G~25GHz: ±5.47 dB;

                                         Table 1 – Values of Ucispr

                                       Measurement                                             Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC)   (30 MHz to 1000 MHz)   6.3 dB
Radiated disturbance (electric field strength in a FAR)                 (1 GHz to 6 GHz)       5.2 dB
Radiated disturbance (electric field strength in a FAR)                 (6 GHz to 18 GHz)      5.5 dB


EUT Setup

Below 1GHz:




Report No.: RDG161009004                                                                  Page 13 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Above 1GHz:




The radiated emission tests were performed at the 3 meters distance in chamber, using the setup
accordance with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.


EMI Test Receiver Setup

The system was investigated from 30 MHz to 5 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:


            Frequency Range            RBW         Video B/W      IF B/W       Detector
           30 MHz – 1000 MHz         120 kHz        300 kHz       120 kHz         QP
                                      1 MHz         3 MHz            /           Peak
               Above 1 GHz
                                      1 MHz          10 Hz           /           AVG



Test Procedure
During the radiated emissions, the adapter of laptop was connected to the first AC floor outlet and
the other support equipments were connected to the second AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
with all installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average
detection mode above 1 GHz.




Report No.: RDG161009004                                                             Page 14 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Equipment List and Details

                                                                 Serial      Calibration Calibration
    Manufacturer         Description                Model
                                                                Number          Date      Due Date
       Agilent              Amplifier               8447D     2944A10442     2015-12-02 2016-12-01
      Rohde &
                      EMI Test Receiver              ESCI       100028       2015-12-02 2016-12-01
      Schwarz
   Sunol Sciences     Broadband Antenna              JB3        A101808      2016-04-10 2019-04-09
      Rohde &
                      Spectrum Analyzer             FSEM30      100018       2015-12-02 2016-12-01
      Schwarz
      EM TEST            Horn Antenna                3115       003-6076     2015-12-02 2016-12-01
     Ducommun                                                 1007726-0113
                         Horn Antenna         ARH-4223-02                    2014-06-16 2017-06-15
    Technologies                                                  024
     Mini-circuits        Amplifier              ZVA-213-S+    771001215     2016-05-20 2017-05-19
                        Semi-Anechoic
        EMCT                                         966          N/A        2015-04-24 2018-04-23
                          Chamber
                          RF Cable
         N/A                                         NO.1         N/A        2015-11-10    2016-11-09
                        (below 1GHz)
                          RF Cable
         N/A                                         NO.4         N/A        2015-11-10    2016-11-09
                        (below 1GHz)
                          RF Cable
         N/A                                         NO.2         N/A        2015-11-10    2016-11-09
                        (above 1GHz)

* Statement of Traceability: BACL (Chengdu) attested that all calibrations have been performed, traceable
to National Primary Standards and International System of Units (SI).

Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting
the Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Loss + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation
is as follows:

        Margin = Limit – Corrected Amplitude

Test Data

     Environmental Conditions


            Temperature:                 32 °C
       Relative Humidity:                 52 %
          ATM Pressure:                 101.5 kPa

    * The testing was performed by Kevin Hu on 2016-11-09.

    Test Result: Compliance
Report No.: RDG161009004                                                                  Page 15 of 17


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Mode: Read

1) Below 1GHz:


                        80

                        70

                        60
       Level in dBμV/




                        50

                        40

                        30

                        20

                        10

                        0
                        30M           50   60      80    100M            200       300    400    500          800    1G
                                                                Frequency in Hz




Frequency                    QuasiPeak          Height                   Azimuth         Corr.     Margin             Limit
                                                          Polarization
  (MHz)                      (dBμV/m)            (cm)                     (deg)          (dB)       (dB)            (dBμV/m)

 36.426250                     28.5             100.0           V          302.0         -10.0         11.5           40.0
421.395000                     32.7             100.0           H          289.0         -10.1         13.3           46.0
433.398750                     36.2             100.0           H          161.0         -10.0         9.8            46.0
438.733750                     33.2             100.0           H          127.0         -10.0         12.8           46.0
599.996250                     33.1             100.0           V          250.0         -7.5          12.9           46.0
720.033750                     33.4             200.0           H          228.0         -5.5          12.6           46.0




Report No.: RDG161009004                                                                                      Page 16 of 17


  Bay Area Compliance Laboratories Corp. (Chengdu)

 2) 1GHz-5GHz:

Frequency       Receiver          Rx Antenna         Cable    Amplifier   Corrected
                                                                                       Limit     Margin
            Reading              Polar Factor          loss    Gain       Amplitude
  (MHz)              Detector                         (dB)      (dB)      (dBμV/m)
            (dBμV)               (H/V)   (dB)                                         (dBμV/m)    (dB)
 1200.4      45.63       PK        H     23.32       2.26      26.62        44.59      74.00      29.41
 1200.4      33.12       AV        H     23.32       2.26      26.62        32.08      54.00      21.92
 1270.54     44.56       PK        H     23.50       2.35      26.55        43.86      74.00      30.14
 1270.54      32.1       AV        H     23.50       2.35      26.55        31.40      54.00      22.60
 2062.12     42.41       PK        H     24.69       3.04      26.83        43.31      74.00      30.69
 2062.12     29.87       AV        H     24.69       3.04      26.83        30.77      54.00      23.23
 1591.18     46.49       PK        V     24.25       2.74      26.42        47.06      74.00      26.94
 1591.18     33.68       AV        V     24.25       2.74      26.42        34.25      54.00      19.75
 1801.6      50.33       PK        V     24.58       2.90      26.63        51.18      74.00      22.82
 1801.6      37.64       AV        V     24.58       2.90      26.63        38.49      54.00      15.51
 2082.16     48.78       PK        V     24.62       3.04      26.83        49.61      74.00      24.39
 2082.16     36.24       AV        V     24.62       3.04      26.83        37.07      54.00      16.93



                                  ***** END OF REPORT *****




 Report No.: RDG161009004                                                               Page 17 of 17



Document Created: 2016-11-17 19:31:46
Document Modified: 2016-11-17 19:31:46

© 2024 FCC.report