Test Report

FCC ID: SS3-MT1SS51905

Test Report

Download: PDF
FCCID_4470111

                                FCC PART 15B
                      ICES-003, ISSUE 6, JANUARY 2016

                                               TEST REPORT
                                                              For

                       SZ DJI TECHNOLOGY CO., LTD
 14th floor, West Wing, Skyworth Semiconductor Design Building NO.18 Gaoxin South 4th Ave,
                                      Nanshan, Shenzhen, Guangdong, China


                                        FCC ID: SS3-MT1SS51905
                                            Model: MT1SS5


            Report Type:                                         Product Type:

            Original Report                                      Mavic Mini

            Report Number:                 RDG190526002-00A

            Report Date:                   2019-06-21

                                           Jerry Zhang
            Reviewed By:
                                           EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
            Test Laboratory:               Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used
by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This
report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


 Bay Area Compliance Laboratories Corp. (Dongguan)                                                                        Report No.: RDG190526002-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.107& ICES-003 §6.1 - CONDUCTED EMISSIONS ...................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109&ICES-003§6.2 - RADIATED SPURIOUS EMISSIONS..................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................19
  TEST DATA ................................................................................................................................................................19




                                                                                                                                                            Page 2 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190526002-00A


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)

                        EUT Name:          Mavic Mini
                        EUT Model:         MT1SS5
                Rated Input Voltage:       DC7.2V from Battery
                       Model Name:         QC18-US
      Adapter
                              Input:       100-240V~ 50/60Hz ,0.5A
    Information
                             Output:       5V 3A/9V 2A/12V 1.5A
       Highest Operation Frequency:        5825 MHz
                External Dimension:        289.1mm(L)*244.5 mm(W)* 54.9mm(H)
                     Serial Number:        190526002
                 EUT Received Date:        2019-05-29

  Note: Both the adapter and battery have two manufacturers; Battery #1 was used in test.



Objective

This report is prepared on behalf of SZ DJI TECHNOLOGY CO., LTD in accordance with Part 2, Subpart J,
and Part 15-Subparts A and B of the Federal Communications Commission’s rules. And ICES-003, Issue 6,
January 2016 Information Technology Equipment (Including Digital Apparatus) — Limits and Methods of
Measurement.

The objective is to determine the compliance of EUT with: FCC Part 15B Class B and ICES-003, Issue 6,
January 2016, Class B.


Related Submittal(s)/Grant(s)

FCC Part 15E NII submissions with FCC ID: SS3-MT1SS51905.
Part of system submissions with FCC ID: SS3-MR1SS51905.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).




                                                                                                  Page 3 of 33


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190526002-00A


Measurement Uncertainty


                Parameter                                   Measurement Uncertainty
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
       Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
                Temperature                                            ±1℃
               Humidity                                                ±5%
   AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)



Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the
No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. : CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio
equipment requirements, the CAB identifier: CN0022.




                                                                                                  Page 4 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190526002-00A


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in downloading or Charging mode.


EUT Exercise Software

The software “Winthrax.exe” was used during test.


Equipment Modifications

No modification was made to the EUT tested.


Local Support Equipment List and Details

        Manufacturer           Description               Model                    Serial Number
           DELL                     Laptop               PP11L                   QDS-BRCM1017
             HP                     Printer              C3941A                    JPTVOB2337
           DELL                    Keyboard               L100             CNORH656658907BL05DC
            SAST                   Modem                AEM-2100                        293
          Kingston                 SD Card                 4G                              /



Support Cable List and Details

                          Shielding                     Length
    Cable Description                    Ferrite Core                   From Port                 To
                            Type                         (m)
       Serial Cable          yes              No          1.2      Serial Port of Laptop       Modem
      Parallel Cable         yes              No          1.2      Parallel Port of Laptop      Printer

     Keyboard Cable          yes              No          1.8       USB Port of Laptop         Keyboard

        USB Cable            Yes              No          0.5        USB Port of EUT            Laptop




                                                                                                  Page 5 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190526002-00A



Configuration of Test Setup
Test mode: Downloading




                                                                      1.0 Meter
Test Mode: Charging




                                                                         Page 6 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: RDG190526002-00A


SUMMARY OF TEST RESULTS

         FCC Rules                        Description of Test              Results

        FCC §15.107                                                      Compliance
                                          Conducted Emissions
        ICES-003 §6.1
        FCC §15.109                                                      Compliance
                                           Radiated Emissions
        ICES-003 §6.2




                                                                                     Page 7 of 33


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190526002-00A


FCC§15.107& ICES-003 §6.1 - CONDUCTED EMISSIONS
EUT Setup




The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used was
with the FCC Part 15 B Class B and ICES-003 Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.

The adapter was connected to the Main LISN with 120V/60Hz AC power source.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                       IF B/W
                              150 kHz – 30 MHz                       9 kHz




                                                                                                Page 8 of 33


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190526002-00A

Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
      Manufacturer              Description          Model
                                                                    Number           Date         Due Date
           R&S              EMI Test Receiver         ESCI           101121        2019-03-23     2020-03-23
         Unknown               Coaxial Cable       C-NJNJ-50       C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32       Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216         101614        2018-12-10      2019-12-10
           R&S                    L.I.S.N           ESH2-Z5       892107/021      2018-09-19      2019-09-19

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed traceable to National Primary Standards and International System of Units (SI).


Test Procedure

During the conducted emission test, the adapter of laptop was connected to the outlet of the first LISN and
the other support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude

VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                    Margin = Limit – Corrected Amplitude




                                                                                                    Page 9 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG190526002-00A

Test Results Summary

According to the recorded data in following table, the EUT complied with the FCC Part 15 B & ICES-003
Class B.


Test Data

    Environmental Conditions

             Temperature:            24.1 C
        Relative Humidity:            41 %
            ATM Pressure:           99.9 kPa

     The testing was performed by Lily Xie on 2019-06-10.




                                                                                         Page 10 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A

Test Mode: Downloading

AC120V, 60Hz, Line:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.150000                    48.6              9.000         L1      11.2        17.4      66.0          Compliance
      0.156097                    45.1              9.000         L1      11.1        20.6      65.7          Compliance
      0.190505                    57.4              9.000         L1      10.7         6.6      64.0          Compliance
      0.193566                    58.2              9.000         L1      10.7         5.7      63.9          Compliance
      0.209621                    55.7              9.000         L1      10.6         7.5      63.2          Compliance
      0.212988                    52.0              9.000         L1      10.5        11.1      63.1          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.190505                    32.1              9.000         L1      10.7        21.9      54.0          Compliance
      0.193566                    44.2              9.000         L1      10.7         9.7      53.9          Compliance
      0.207957                    39.1              9.000         L1      10.6        14.2      53.3          Compliance
      0.212988                    28.0              9.000         L1      10.5        25.1      53.1          Compliance
      0.257874                    24.7              9.000         L1      10.3        26.8      51.5          Compliance
      4.193667                    27.2              9.000         L1       9.8        18.8      46.0          Compliance




                                                                                                                 Page 11 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A

AC120V, 60Hz, Neutral:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.187494                    55.1              9.000         N       10.7         9.0      64.1          Compliance
      0.190505                    59.3              9.000         N       10.7         4.7      64.0          Compliance
      0.193566                    60.3              9.000         N       10.7         3.6      63.9          Compliance
      0.209621                    57.6              9.000         N       10.5         5.6      63.2          Compliance
      0.214692                    50.4              9.000         N       10.5        12.6      63.0          Compliance
      0.255827                    49.1              9.000         N       10.3        12.5      61.6          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.187494                    29.9              9.000         N       10.7        24.2      54.1          Compliance
      0.193566                    41.4              9.000         N       10.7        12.5      53.9          Compliance
      0.198249                    39.2              9.000         N       10.6        14.5      53.7          Compliance
      0.211298                    30.4              9.000         N       10.5        22.8      53.2          Compliance
      0.262017                    32.2              9.000         N       10.3        19.2      51.4          Compliance
      4.399032                    29.6              9.000         N        9.8        16.4      46.0          Compliance




                                                                                                                 Page 12 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A


Test Mode: Charging(Aohai Adapter)

AC120V, 60Hz, Line:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.164053                    57.9              9.000         L1      11.0         7.4      65.3          Compliance
      0.256712                    51.1              9.000         L1      10.3        10.4      61.5          Compliance
      0.515160                    40.3              9.000         L1       9.9        15.7      56.0          Compliance
      0.774673                    31.4              9.000         L1       9.8        24.6      56.0          Compliance
      1.286792                    30.4              9.000         L1       9.8        25.6      56.0          Compliance
      3.621856                    26.4              9.000         L1       9.8        29.6      56.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.169024                    32.7              9.000         L1      10.9        22.3      55.0          Compliance
      0.422196                    24.5              9.000         L1       9.9        22.9      47.4          Compliance
      0.510059                    29.5              9.000         L1       9.9        16.5      46.0          Compliance
      1.236582                    24.6              9.000         L1       9.8        21.4      46.0          Compliance
      1.261437                    24.8              9.000         L1       9.8        21.2      46.0          Compliance
      3.621856                    16.3              9.000         L1       9.8        29.7      46.0          Compliance




                                                                                                                 Page 13 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A

AC120V, 60Hz, Neutral:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.159228                    57.7              9.000         N       11.0         7.8      65.5          Compliance
      0.259279                    50.3              9.000         N       10.3        11.2      61.5          Compliance
      0.452652                    39.5              9.000         N        9.9        17.3      56.8          Compliance
      0.737074                    30.7              9.000         N        9.8        25.3      56.0          Compliance
      1.286792                    30.4              9.000         N        9.8        25.6      56.0          Compliance
      3.621856                    27.2              9.000         N        9.8        28.8      56.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.169024                    33.2              9.000         N       10.9        21.8      55.0          Compliance
      0.422196                    24.9              9.000         N        9.9        22.5      47.4          Compliance
      0.515160                    30.6              9.000         N        9.9        15.4      46.0          Compliance
      1.236582                    25.2              9.000         N        9.8        20.8      46.0          Compliance
      1.261437                    25.4              9.000         N        9.8        20.6      46.0          Compliance
      3.621856                    17.0              9.000         N        9.8        29.0      46.0          Compliance




                                                                                                                 Page 14 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A


Test Mode: Charging(BYDAdapter)

AC120V, 60Hz, Line:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.151500                    53.5              9.000         L1      11.2        12.4      65.9          Compliance
      0.259279                    42.2              9.000         L1      10.3        19.3      61.5          Compliance
      0.475741                    32.2              9.000         L1       9.9        24.2      56.4          Compliance
      0.751890                    26.6              9.000         L1       9.8        29.4      56.0          Compliance
      1.786955                    29.0              9.000         L1       9.7        27.0      56.0          Compliance
      2.137462                    28.9              9.000         L1       9.7        27.1      56.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.150000                    31.7              9.000         L1      11.2        24.3      56.0          Compliance
      0.422196                    20.5              9.000         L1       9.9        26.9      47.4          Compliance
      0.546852                    21.4              9.000         L1       9.9        24.6      46.0          Compliance
      1.236582                    21.4              9.000         L1       9.8        24.6      46.0          Compliance
      1.261437                    21.4              9.000         L1       9.8        24.6      46.0          Compliance
      2.137462                    18.7              9.000         L1       9.7        27.3      46.0          Compliance




                                                                                                                 Page 15 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG190526002-00A

AC120V, 60Hz, Neutral:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.156091                    53.8              9.000         N       11.1        11.9      65.7          Compliance
      0.259279                    46.5              9.000         N       10.3        14.9      61.4          Compliance
      0.434989                    37.6              9.000         N        9.9        19.6      57.2          Compliance
      0.782419                    27.0              9.000         N        9.8        29.0      56.0          Compliance
      3.621856                    24.8              9.000         N        9.8        31.2      56.0          Compliance
     10.093288                    31.5              9.000         N        9.8        28.5      60.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.150000                    32.8              9.000         N       11.2        23.2      56.0          Compliance
      0.418016                    22.3              9.000         N        9.9        25.2      47.5          Compliance
      0.546852                    25.8              9.000         N        9.8        20.2      46.0          Compliance
      1.236582                    21.6              9.000         N        9.8        24.4      46.0          Compliance
      1.261437                    21.4              9.000         N        9.8        24.6      46.0          Compliance
      3.621856                    18.8              9.000         N        9.8        27.2      46.0          Compliance




                                                                                                                 Page 16 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190526002-00A


FCC §15.109&ICES-003§6.2 - RADIATED SPURIOUS EMISSIONS

EUT Setup

Below 1GHz:




Above 1GHz:




The radiated emission below 1GHz tests were performed in the 10 meters chamber test site, above 1GHz
tests were performed in the 3 meters chamber test site B, 1GHz-26.5GHz were performed at the 3 m distance
and 26.5-30 GHz was performed at 1 m distance, using the setup accordance with the ANSI C63.4-2014.
The specification used was with the FCC Part 15.109 and ICES-003 Class B limits.




                                                                                            Page 17 of 33


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190526002-00A

EMI Test Receiver Setup

The system was investigated from 30 MHz to 30 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

              Frequency Range             RBW          Video B/W        IF B/W      Measurement
             30 MHz – 1000 MHz           120 kHz        300 kHz         120 kHz           QP
                                          1 MHz          3 MHz             /             Peak
                Above 1 GHz                             Reduced
                                          1 MHz                            /             AVG
                                                         VBW

If the maximized peak measured value complies with under the limit more than 6dB, then it is unnecessary to
perform an QP/Average measurement.


Test Procedure

During the radiated emissions, the adapter of laptop was connected to the first AC floor outlet and the other
support equipments were connected to the second AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection mode
above 1 GHz.




                                                                                                Page 18 of 33


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190526002-00A

Test Equipment List and Details

                                                                       Serial      Calibration    Calibration
    Manufacturer          Description              Model
                                                                     Number           Date         Due Date
         R&S           EMI Test Receiver            ESCI              100224       2018-12-10     2019-12-10
        Farad            Test Software            EZ-EMC             V1.1.4.2         N/A            N/A
    Sunol Sciences          Antenna                  JB3            A060611-3      2017-07-21     2019-07-21
       Unknown           Coaxial Cable           C-NJNJ-50          C-1000-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0400-02      2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0530-01      2018-09-24     2019-09-24
       Sonoma              Amplifier                310N              185914       2018-10-13     2019-10-13
        Agilent        Spectrum Analyzer          E4440A           SG43360054      2019-01-04     2020-01-04
         R&S           Spectrum Analyzer           FSP 38             100478       2018-12-10     2019-12-10
    ETS-Lindgren         Horn Antenna               3115            000 527 35     2018-10-12     2021-10-12
      Ducommun                                                     1007726-01
                         Horn Antenna          ARH-4223-02                          2016-11-18    2019-11-18
     Technolagies                                                      1304
      Ducommun                                                     1007726-01
                         Horn Antenna          ARH-2823-02                          2016-11-18    2019-11-18
     Technolagies                                                      1302
       Unknown           Coaxial Cable          C-SJSJ-50           C-0800-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable         C-2.4J2.4J-50        C-0700-02      2018-06-27     2019-06-27
                                             AFS42-00101800-2
        MITEQ              Amplifier                                 2001271       2018-09-05     2019-09-05
                                                  5-S-42
       Quinstar            Amplifier         QLW-18405536-JO       15964001001     2018-06-27     2019-06-27

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).



Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

                                   Margin = Limit – Corrected Amplitude

Test Data

    Environmental Conditions


             Temperature:              20.7~21.8 C
         Relative Humidity:              34~47 %
            ATM Pressure:              99.7~99.8 kPa

     * The testing was performed by Vito Chen & Neil Liao on 2019-06-10~2019-06-11.
     Test Result: Compliance

                                                                                                   Page 19 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Test Mode: Downloading

1) Below 1GHz:

    Horizontal




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    81.4100         47.55          peak             -19.43    28.12          40.00        11.88
    238.5500        50.80          peak             -13.58    37.22          46.00         8.78
    312.2700        47.99          peak             -10.44    37.55          46.00         8.45
    368.5300        46.85           QP               -8.85    38.00          46.00         8.00
    549.9200        35.31          peak              -4.18    31.13          46.00        14.87
    780.7800        40.77           QP               -0.87    39.90          46.00         6.10




                                                                                         Page 20 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    36.7900         35.88          peak             -11.29    24.59          40.00        15.41
    162.8900        39.59          peak             -12.88    26.71          43.50        16.79
    238.5500        43.73          peak             -13.58    30.15          46.00        15.85
    368.5300        46.95           QP               -8.85    38.10          46.00         7.90
    600.3600        38.59          peak              -3.35    35.24          46.00        10.76
    780.7800        36.71          peak              -0.87    35.84          46.00        10.16




                                                                                         Page 21 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

2) Above 1GHz:

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   1397.500         58.61          peak             -9.54    49.07          74.00        24.93
   1397.500         45.30          AVG              -9.54    35.76          54.00        18.24
   1800.000         60.19          peak             -7.77    52.42          74.00        21.58
   1800.000         37.46          AVG              -7.77    29.69          54.00        24.31
   3187.500         50.66          peak             -4.23    46.43          74.00        27.57
   3187.500         37.16          AVG              -4.23    32.93          54.00        21.07




                                                                                        Page 22 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    1195.000        60.77          peak             -9.98    50.79          74.00        23.21
    1195.000        47.13          AVG              -9.98    37.15          54.00        16.85
    2000.000        62.20          peak             -7.18    55.02          74.00        18.98
    2000.000        50.00          AVG              -7.18    42.82          54.00        11.18
    3195.000        55.47          peak             -4.22    51.25          74.00        22.75
    3195.000        43.21          AVG              -4.22    38.99          54.00        15.01




                                                                                        Page 23 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   18000.000        43.74          peak             17.15    60.89          74.00        13.11
   18000.000        30.12          AVG              17.15    47.27          54.00        6.73




                                                                                        Page 24 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    18000.000       44.27          peak             17.15    61.42          74.00        12.58
    18000.000       31.05          AVG              17.15    48.20          54.00         5.80




                                                                                        Page 25 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   26431.864        40.43          peak             21.54    61.97          74.00        12.03
   26431.864        27.54          AVG              21.54    49.08          54.00         4.92




                                                                                        Page 26 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    26380.762       41.51          peak             21.32    62.83          74.00        11.17
    26380.762       28.34          AVG              21.32    49.66          54.00         4.34




                                                                                        Page 27 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   26962.926        45.27          peak             2.54     47.81          74.00        26.19
   26962.926        33.77          AVG              2.54     36.31          54.00        17.69




                                                                                        Page 28 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    28982.966       46.42          peak             2.91     49.33          74.00        24.67
    28982.966       33.74          AVG              2.91     36.65          54.00        17.35




                                                                                        Page 29 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Test Mode: Charging(Aohai Adapter)

3) Below 1GHz:

    Horizontal




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    34.8500         31.96          peak             -10.33    21.63          40.00        18.37
    93.0500         38.51          peak             -18.48    20.03          43.50        23.47
    177.4400        42.89          peak             -13.28    29.61          43.50        13.89
    299.6600        39.42          peak             -10.83    28.59          46.00        17.41
    396.6600        37.87          peak              -8.24    29.63          46.00        16.37
    906.8800        26.11          peak              1.20     27.31          46.00        18.69




                                                                                         Page 30 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    33.8800         41.77          peak              -9.83    31.94          40.00         8.06
    68.8000         45.15          peak             -20.06    25.09          40.00        14.91
    143.4900        39.57          peak             -12.72    26.85          43.50        16.65
    285.1100        33.95          peak             -11.62    22.33          46.00        23.67
    528.5800        35.14          peak              -5.10    30.04          46.00        15.96
    660.5000        30.91          peak              -2.45    28.46          46.00        17.54




                                                                                         Page 31 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Test Mode: Charging(BYD Adapter)

4) Below 1GHz:

    Horizontal




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    30.9700         29.29          peak              -8.40    20.89          40.00        19.11
    141.5500        47.51           QP              -12.71    34.80          43.50         8.70
    299.6600        39.50          peak             -10.83    28.67          46.00        17.33
    396.6600        39.19          peak              -8.24    30.95          46.00        15.05
    660.5000        29.43          peak              -2.45    26.98          46.00        19.02
    979.6300        25.18          peak              2.35     27.53          54.00        26.47




                                                                                         Page 32 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190526002-00A

Vertical




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    42.6100         39.64          peak             -14.73    24.91          40.00        15.09
    133.7900        48.91          peak             -13.13    35.78          43.50         7.72
    328.7600        32.68          peak             -10.06    22.62          46.00        23.38
    527.6100        34.06          peak              -5.13    28.93          46.00        17.07
    660.5000        33.03          peak              -2.45    30.58          46.00        15.42
    925.3100        25.95          peak              1.45     27.40          46.00        18.60




                                   ****END OF REPORT****




                                                                                         Page 33 of 33



Document Created: 2019-10-08 04:39:58
Document Modified: 2019-10-08 04:39:58

© 2024 FCC.report