RF Exposure

FCC ID: SS3-MT1SS51905

RF Exposure Info

Download: PDF
FCCID_4470102

Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG190526002-00B

FCC §15.407 (f) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.407(f)and subpart §1.1310, systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                          (B) Limits for General Population/Uncontrolled Exposure
Frequency Range         Electric Field       Magnetic Field        Power Density           Averaging Time
     (MHz)             Strength (V/m)        Strength (A/m)           (mW/cm2)               (minutes)
    0.3–1.34                 614                   1.63                 *(100)                   30
    1.34–30                 824/f                 2.19/f               *(180/f²)                 30
    30–300                  27.5                  0.073                   0.2                    30
   300–1500                   /                      /                  f/1500                   30
 1500–100,000                 /                      /                    1.0                    30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculation formula:

Prediction of power density at the distance of the applicable MPE limit
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                               Conducted
                                              output power     Evaluation      Power       MPE
          Frequency      Antenna Gain
                                            including Tune-     Distance      Density      Limit
            (MHz)
                                              up Tolerance        (cm)       (mW/cm2)    (mW/cm2)
                       (dBi)   (numeric)    (dBm) (mW)
          5745-5825      4        2.51        24       251        20.00           0.13      1.0

Note 1: the Max. Target Power including Tolerance was declared by manufacturer.

Result: Compliance, The device meets MPE requirement for Devices Used by the General Public
(Uncontrolled Environment) at distance ≥20 cm.




                                                                                                  Page 11 of 57



Document Created: 2019-10-08 04:40:19
Document Modified: 2019-10-08 04:40:19

© 2024 FCC.report