Test Report

FCC ID: SS3-201309001

Test Report

Download: PDF
FCCID_2112313

                                                        Report No.: $Z13080123E02
                                                                                                            \‘“‘Ill.,’lll


                                                                                                         /4
                                     FCC TEST REP
                                                                            Issued to

                                                  SZ DJI TECHNOLOGY CO., LTD.

                                                                              For

                                                           2.4G Bluetooth Datalink


                                        Model Name:               LK24—BT
                                        Trade Name:                DJI
                                        Brand Name:               DJI
                                         FCC ID:                  $$3—201309001
                                         Standard:                47 CFR Part 15 Subpart B
                                        Test date:                September 16, 2013 — September 30, 2013
                                         Issue date:              November 1, 2013




                                                                       €,                      2
  Tested by _YiG# KFrr‘l,                                          4                    ,            S    Review by             lh/afi
               Xiao Xiong                                                                                                  Huang Pulong
            (Test Engineer)                                                                                                (EMC Manager)
  Date 2a15 .|| . |                                                                                                            oBB.1[. [


                                                                                                                               B           t
                                                                                                                           OBluetoot                 CC
   IEEE 1725            OTA                                                                                                     BQTF              Reg. No:
                                                                                                                                                  695796


The report refers onlyto the sample tested anddoes not apply to the bult. This report is isuedin confidence to the client andit will be strietly reatedas such by
the Shenthon MORLAB Communication TechnologyCo—. Lid. It may not be reproduced rather in ts entietyor in part and it maynot be usedfor adverting. The
elientto whom the report is issued may, hawever, showor send it or a certified capy there of prepared bythe Shenzhen MORLABTelecommunication Ca., Lid to
his customer Supplieror others persons directly concerned. Shenzhen MORLAB Telecommunication Co., Ltd will not, without the consent of the client enter io
n discussion ofcommespondence with anythind party concerning the contents ofthe report. In the event ofthe improperuse ofthe report, Shenzhen MORLAB
Telecommunication Co., Lid reserves the rights to withdrav it and to adopt enother remedies which maybe appropriate

Shenzhen MORLAB Communication Technology Co., Ltd
FL—3, Building A. F i Scie rk, No 8 LongChang Road, Block BaoAn Distriet,


                                                                                                            Report No.: SZ13080123E02


                                                     TABLE OF CONTENTS
1.       GENERAL INFORMATION ....................................................................................................3

1.1      EUT Description .........................................................................................................................3
1.2      Test Standards and Results ........................................................................................................4
1.3      Facilities and Accreditations ......................................................................................................5
1.3.1       Facilities ....................................................................................................................................5
1.3.2       Test Environment Conditions ....................................................................................................5
1.3.3       Measurement Uncertainty .........................................................................................................5

2.       TEST CONDITIONS SETTING...............................................................................................6

2.1      Test Mode ....................................................................................................................................6
2.2      Test Setup and Equipments List ................................................................................................7
2.2.1       Conducted Emission..................................................................................................................7
2.2.2       Radiated Emission .....................................................................................................................8

3.       47 CFR PART 15B REQUIREMENTS .................................................................................. 11

3.1      Conducted Emission ................................................................................................................. 11
3.1.1       Requirement ............................................................................................................................ 11
3.1.2       Test Description ...................................................................................................................... 11
3.1.3       Test Result ............................................................................................................................... 11
3.2      Radiated Emission ....................................................................................................................13
3.2.1       Requirement ............................................................................................................................13
3.2.2       Test Description ......................................................................................................................13
3.2.3       Frequency range of measurement ...........................................................................................13
3.2.4       Test Result ...............................................................................................................................14

** END OF REPORT ** ......................................................................................................................16


                                                                 Change History
        Issue                Date                                                          Reason for change
         1.0            November 1, 2013                                                     First edition




                                                                                                                                      Page 2 of 16


                                                                               Report No.: SZ13080123E02



1.         GENERAL INFORMATION

1.1        EUT Description
 EUT Type ..........................     2.4G Bluetooth Datalink
 Serial No. ..........................   (n.a., marked #1 by test site)
 Hardware Version .............          V1
 Software Version ...............        1.0
 Applicant...........................    SZ DJI TECHNOLOGY CO., LTD.
                                         Room 613、614, 6/F, HKUST SZ IER Bldg, No.9 Yuexing 1st Rd
                                         Hi-Tech Park(South), Nanshan District, Shenzhen, Guangdong, China
 Manufacturer.....................       SZ DJI TECHNOLOGY CO., LTD.
                                         6F, HKUST SZ IER Bldg. No.9 Yuexing 1st Rd. Hi-Tech Park(South),
                                         Nanshan Dist. Shenzhen, Guangdong, China
 Modulation Type ...............         GFSK
 Working Voltage ...............         12V
 Working Current ...............         0.2A
 Speed of the processor ...              100MHz
Note:
1. The EUT is a 2.4G Bluetooth Datalink, it consists of the Air end and the Ground end, which
   provides reliable and stable remote wireless transmissions for Ground Station based application.
   The Ground end has a USB port for charging and updating software when connected with the PC.
2. Please refer to ANNEX A for the photographs of the EUT. For a more detailed description, please
   refer to Specification or User’s Manual supplied by the applicant and/or manufacturer.




                                                                                              Page 3 of 16


                                                                       Report No.: SZ13080123E02


1.2       Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

        No.    Identity                             Document Title
        1      47 CFR Part 15(10-1-12 Edition)      Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

        No.   Section      Description                                               Result
        1     15.107       Conducted Emission                                        PASS
        2     15.109       Radiated Emission                                         PASS

NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2009.




                                                                                           Page 4 of 16


                                                                        Report No.: SZ13080123E02


1.3      Facilities and Accreditations

1.3.1    Facilities

Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory is a testing organization
accredited by China National Accreditation Service for Conformity Assessment (CNAS) according to
ISO/IEC 17025. The accreditation certificate number is L3572.

All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang
Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R.
China 518101. The test site is constructed in conformance with the requirements of ANSI C63.4-2009 and
CISPR Publication 22:2010; the FCC registration number is 695796.

1.3.2    Test Environment Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                        15 - 35
 Relative Humidity (%):                   30 - 60
 Atmospheric Pressure (kPa):              86 -106

1.3.3    Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission:       ±1.8dB
 Uncertainty of Radiated Emission:        ±3.1dB




                                                                                         Page 5 of 16


                                                                    Report No.: SZ13080123E02



2.     TEST CONDITIONS SETTING

2.1    Test Mode
         The EUT configuration of the emission tests is EUT + PC.
          During the measurement, the Ground end was connected with a PC through the USB port,
      it powered by the PC and worked as unintentional equipments.




                                                                                  Page 6 of 16


                                                                     Report No.: SZ13080123E02


2.2       Test Setup and Equipments List

2.2.1     Conducted Emission

A. Test Setup:



        < 40cm >                < 80cm >




                   EUT

                                                               Pulse Limiter
        < 80cm >                                    LISN
                                                                            Receiver




The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains
through a LISN which provides 50Ω/50µH of coupling impedance for the measuring instrument. A
Pulse Limiter is used to protect the measuring instrument. The factors of the whole test system are
calibrated to correct the reading.

B. Equipments List:

     Description        Manufacturer      Model           Serial No.      Cal. Date     Due. Date
    EMC Analyzer          Agilent        E7405A         US44210471       12/05/2013     11/05/2014
       Receiver            Narda        PMM 9010        595WX11007       12/11/2012     11/11/2013
        LISN            Schwarzbeck     NSLK 8127          812744        12/05/2013     11/05/2014
 Pulse Limiter (20dB)   Schwarzbeck       VTSD              9391            (n.a.)         (n.a.)
                                         9561-D
  System Simulator         Agilent       E5515C         GB43130131       12/05/2013     11/05/2014
        PC                 Lenovo      ThinkPadT61       ZZF3077            (n.a.)         (n.a.)




                                                                                       Page 7 of 16


                                                   Report No.: SZ13080123E02


2.2.2   Radiated Emission

A. Test Setup:

    1) For radiated emissions from 9kHz to 30MHz




    2) For radiated emissions from 30MHz to1GHz




                                                                 Page 8 of 16


                                                                       Report No.: SZ13080123E02

    3) For radiated emissions above 1GHz




The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the
site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating Turn
Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height antenna
master tower.

For the test Antenna:

1) In the frequency range of 9KHz to 30MHz, magnetic field is measured with Loop Test Antenna.

    The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
    the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
    rotates about its vertical axis for maximum response at each azimuth about the EUT.

2) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
   Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
   varied from 1m to 4m above the ground to determine the maximum value of the field strength.
   The emission levels at both horizontal and vertical polarizations should be tested.

B. Equipments List:

     Description         Manufacturer       Model          Serial No.      Cal. Date    Due. Date
   EMC Analyzer            Agilent         E7405A         US44210471      12/05/2013    11/05/2014
   Semi-Anechoic          Albatross       9m*6m*6m           (n.a.)       12/05/2012    11/05/2014
      Chamber
Test Antenna - Bi-Log    Schwarzbeck      VULB 9163         9163-274      12/05/2012    11/05/2014



                                                                                       Page 9 of 16


                                                               Report No.: SZ13080123E02


    Description       Manufacturer    Model       Serial No.       Cal. Date     Due. Date
Test Antenna - Horn   Schwarzbeck BBHA 9120D     9120D-963        12/05/2012     11/05/2014
Test Antenna -Loop    Schwarzbeck FMZB 1519       1519-022        12/05/2012     11/05/2014
        PC              Lenovo     ThinkPadT61    ZZF3077            (n.a.)         (n.a.)




                                                                               Page 10 of 16


                                                                      Report No.: SZ13080123E02



3.       47 CFR PART 15B REQUIREMENTS

3.1      Conducted Emission

3.1.1    Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

                                                    Conducted Limit (dBµV)
 Frequency range (MHz)
                                       Quasi-peak                            Average
        0.15 - 0.50                     66 to 56                             56 to 46
         0.50 - 5                          56                                   46
          5 - 30                           60                                   50

NOTE:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2    Test Description

See section 2.2.1 of this report.

3.1.3    Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and
N phase lines of the power mains connected to the EUT are performed. All test modes are considered,
refer to recorded points and plots below.

3.1.3.1 Test Mode

A. Test Plot and Suspicious Points:




                                                                                     Page 11 of 16


                                        Report No.: SZ13080123E02




                    (Plot A: L Phase)




                    (Plot B: N Phase)

Test Result: PASS


                                                     Page 12 of 16


                                                                     Report No.: SZ13080123E02


3.2       Radiated Emission

3.2.1     Requirement

According to FCC section 15.109(a)(e), the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

        Frequency          Field Strength        Field Strength Limitation at 3m Measurement Dist
      range (MHz)         µV/m            Dist           (uV/m)                  (dBuV/m)
      0.009 - 0.490    2400/F(KHz)       300m    10000* 2400/F(KHz) 20log 2400/F(KHz) + 80
      0.490 - 1.705    2400/F(KHz)        30m     100* 2400/F(KHz)        20log 2400/F(KHz) + 40
      1.705 - 30.00         30            30m            100*30                 20log 30 + 40
       30.0 - 88.0         100             3m              100                    20log 100
       88.0 - 216.0        150             3m              150                    20log 150
      216.0 - 960.0        200             3m              200                    20log 200
      Above 960.0          500             3m              500                    20log 500

Note: The limits of frequency below 30MHz is quoted from FCC section 15.209.

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this part,
including emission measurements below 1000MHz, there also is a limit on the radio frequency
emissions, as measured using instrumentation with a peak detector function, corresponding to 20dB
above the maximum permitted average limit for the frequency being investigated unless a different
peak emission limit is otherwise specified in the rules.

Note:
1) The tighter limit shall apply at the boundary between two frequency range.
2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using
    the formula of Ld1 = Ld2 * (d2/d1)2.
    Example:
    F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
    Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m

3.2.2     Test Description

See section 2.2.2 of this report.

3.2.3     Frequency range of measurement

Highest frequency generated or used in the device is the highest speed of the processor, lowest


                                                                                    Page 13 of 16


                                                                                                                   Report No.: SZ13080123E02

frequency generated or used in the device is the lowest frequency of the oscillator. According to
15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the following table:

                                                                                                             Frequency range of radiated
        Frequency                Frequency generated or used in the device
                                                                                                              measurement in the report
          Highest                                            100MHz                                                    1GHz

3.2.4        Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to
perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of spurious emissions which are attenuated more than 20 dB below the permissible
value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test
condition was recorded in this test report.

B. Test Plots and Suspicious Points:

    NOTE: The emissions are too small to be measured and are at least 6 dB below the limit, So all
    the data of marked are pass.

        150DBuV
            No Frequency       PeakAp     QP-Limit       AV-Limit     Quasi-P    Avera-P       Result
              1     84 K   49.38 DBuV       109.11             --           --         --          --
              2
        130DBuV
                 23.87 M   42.63 DBuV        69.50             --           --         --          --



        110DBuV




        90DBuV



        70DBuV


                                               1
        50DBuV
                                                                                                                                               2



        30DBuV



        10DBuV



        -10DBuV




      -30DBuV
     9K10K         20K     30K   40K 50K60K70K80K
                                                90K
                                                  100K         200K     300K 400K500K600K
                                                                                        700K
                                                                                           800K
                                                                                             900K
                                                                                               1M       2M    3M    4M 5M 6M 7M8M9M10M      20M 30M



                                                                      (Plot A: 9K – 30M)


                                                                                                                                         Page 14 of 16


                                                         Report No.: SZ13080123E02




                (Plot B: 30MHz – 1GHz, Test Antenna Vertical)

NO.     Fre.    Pk     QP     AV     Limit   Limit- Limit-      Antenna    Verdict
       (MHz)                         -PK      QP     AV
 1    170.299   N.A   30.35   N.A    N.A      43.5   N.A        Vertical     Pass
 2    201.746   N.A   28.94   N.A    N.A      43.5   N.A        Vertical     Pass
 3    342.045   N.A   30.80   N.A    N.A      46.0   N.A        Vertical     Pass
 4    455.736   N.A   39.78   N.A    N.A      46.0   N.A        Vertical     Pass
 5    508.953   N.A   36.37   N.A    N.A      46.0   N.A        Vertical     Pass
 6    755.686   N.A   36.29   N.A    N.A      46.0   N.A        Vertical     Pass




                                                                           Page 15 of 16


                                                                Report No.: SZ13080123E02




                      (Plot C: 30MHz – 1GHz, Test Antenna Horizontal)

     NO.      Fre.    Pk     QP      AV    Limit- Limit- Limit-     Antenna      Verdict
             (MHz)                          PK     QP     AV
      1     148.529   N.A   34.18    N.A    N.A    43.5   N.A      Horizontal      Pass
      2     179.975   N.A   36.57    N.A    N.A    43.5   N.A      Horizontal      Pass
      3     293.666   N.A   34.24    N.A    N.A    46.0   N.A      Horizontal      Pass
      4     610.549   N.A   37.74    N.A    N.A    46.0   N.A      Horizontal      Pass
      5     755.686   N.A   38.81    N.A    N.A    46.0   N.A      Horizontal      Pass
      6     970.973   N.A   39.87    N.A    N.A    54.0   N.A      Horizontal      Pass


Test Result: Pass

                                    ** END OF REPORT **




                                                                                Page 16 of 16