Application Frequency Range | Final Action Date Granted |
---|
IPT04GfARiVtKq6rJGt0VA== - |
2019-08-13 APPROVED |
Ka8UVQHHXZh/qfGjeISjqA== 2402.0-2480.0 |
2019-08-13 APPROVED |
Ka8UVQHHXZh/qfGjeISjqA== 2412.0-2462.0 |
2019-08-13 APPROVED |
dwC8ZK9QyK6NWZRgmr2TZA== 2402.0-2480.0 |
2019-08-13 APPROVED |
7KTifbIZuAhaShupjit8RA== 13.56-13.56 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 782.0-782.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 825.5-847.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 826.5-846.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 829.0-844.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1712.5-1752.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1712.5-1777.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1715.0-1750.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1715.0-1775.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1720.0-1745.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1720.0-1770.0 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1852.5-1907.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1857.5-1902.5 |
2019-08-13 APPROVED |
f6e+5FSFJBg6JFgzafatzw== 1860.0-1900.0 |
2019-08-13 APPROVED |
bIJDOgbkqatd1sIBGUUD8A== 5180.0-5240.0 |
2019-08-13 APPROVED |
bIJDOgbkqatd1sIBGUUD8A== 5745.0-5825.0 |
2019-08-13 APPROVED |
Application Details:
Equipment | LTE Digital Mobile Phone |
FRN | 0022602015 |
Grantee Code | SRQ |
Product Code | -Z6530V |
Applicant Business | ZTE Corporation |
Business Address | ZTE Plaza, Keji Road South , Shenzhen,N/A China |
TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
TCB Email | [email protected] |
Applicant | Yu Gong – Certification Manager |
Applicant Phone | |
Applicant Fax | +86-21-50801070 |
Applicant Email | [email protected] |
Applicant MailStop | |
Test Firm | Sporton International (Kunshan) Inc. |
Test Firm Contact | Michael Lin |
Test Firm Phone | |
Test Firm Fax | |
Test Firm Email | [email protected] |
Certified By | Michael Lin – Vice President |
Comment [bIJDOgbkqatd1sIBGUUD8A==]: Output power listed is conducted. This device is approved for use in the handset described in this filing. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1 cm separation between the device including its antenna and the body of user. End-users must be informed of the body-worn accessory operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 1.19 W/kg, 0.48 W/kg, 0.66 W/kg, and 1.46 W/kg, respectively.
HAC Rating: M4 T4 2011.
Comment [dwC8ZK9QyK6NWZRgmr2TZA==]: Output power listed is conducted. This device is approved for use in the handset described in this filing. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1 cm separation between the device including its antenna and the body of user. End-users must be informed of the body-worn accessory operating requirements for satisfying RF exposure compliance. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are < 0.10 W/kg and 1.46 W/kg, respectively.
Comment [f6e+5FSFJBg6JFgzafatzw==]: Output power listed is ERP for Part 22 and Part 27 for frequencies below 1 GHz, EIRP for Part 24 and Part 27 for frequencies above 1 GHz.
SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.30 W/kg, 0.64 W/kg, 0.66 W/kg, and 1.46 W/kg, respectively.
This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.
HAC Rating: M4 T4 2011.
Comment [Ka8UVQHHXZh/qfGjeISjqA==]: Output power listed is conducted. This device is approved for use in the handset described in this filing. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1 cm separation between the device including its antenna and the body of user. End-users must be informed of the body-worn accessory operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.27 W/kg, 0.12 W/kg, 0.12 W/kg, and 0.77 W/kg, respectively.
HAC Rating: M4 T4 2011.