RF Exposure

FCC ID: SQ9XKT1291

RF Exposure Info

Download: PDF
FCCID_2031145

                         INTERTEK TESTING SERVICES

For Standalone SAR test exclusion consideration, when the corresponding SAR Exclusion
Threshold requirement in KDB 447498 is satisfied, standalone SAR evaluation for general
population exposure conditions, by measurement or numerical simulation is not required.

Description the tested model: XKT1291

 EUT Description                   :   2.4GHz Transceiver
 Model                             :   XKT1291
 Operating Configuration(s)        :   Table-top
 Operating mode (s)                :   Data Transmission
 Device Category                   :   Portable Device
 Tx Frequency                      :   2422 – 2460 MHz
 Production tolerance              :   -6 dBm (Minimum) to 0 dBm (Maximum)
 Antenna gain                      :   0 dBi = 1.00 (num gain)
 Maximum source-based time-
                                   :   12.00% = (0.96/8 x100%)
 averaging duty factor
 Minimum separation distance       :   5 mm
                                       FCC KDB 447498 D01
 Applicable FCC KDB                :
                                       FCC KDB 865664 D02

From above data, the source-based time-averaging output power is as follow:

             The Maximum Conducted Power           = 0 dBm
                                                   = 1.0 mW

         The Maximum conducted Power source-based time-averaging output power

                                                   = (1.0 * 0.1200) mW
                                                   = 0.120 mW
In the frequency range of 100MHz to 6GHz and test separation distance ≤ 50mm, the SAR
Exclusion Threshold will be determined as follow,

         The SAR exclusion threshold       = 3.0  TD  / F (GHz )
                                           = 9.56 mW

         where TD = 5 mm and F(GHz) = 2.46 GHz


Conclusion

Since the calculated conducted source-based time-averaged output power is 0.120 mW,
which is less than the SAR Exclusion Threshold at 5mm test separation distance 9.56 mW
for general population and uncontrolled exposure, standalone SAR evaluation for general
population exposure conditions, by measurement or numerical simulation is not required.


 FCC ID: SQ9XKT1291
                                                                      RF exposure - 1 of 1



Document Created: 2013-07-31 10:41:14
Document Modified: 2013-07-31 10:41:14

© 2024 FCC.report